CS Paper Radar

Daily listing

2026-10-24 · eess.IV

3 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 3

Semantic-Guided Frequency Modulation for Learned Image Compression

eess.IV cs.CV ·2026-10-24 ·Gangyi Tian, Wen Ji, Alireza Furutanpey, Mingxuan Li
Abstract

High-frequency attenuation can reduce the rate of learned image codecs but also remove object boundaries and fine detail. We propose Semantic-Guided Adaptive Latent-Frequency Modulation (SG-AFM), which uses a semantic structural prior to guide attenuation of encoder latents. SG-AFM applies a Haar wavelet transform and combines a fixed semantic-frequency multiplier with a bounded learned correction to modulate high-frequency subbands. The semantic prior is computed only at the encoder. No semantic map is transmitted, and no decoder modules are added. Across six datasets, SG-AFM reduces PSNR-based BD-rate relative to TCM by an average of 13.17%. It achieves the best BD-rate among the compared methods on ExDark, NightCity, and OnePlus, with a mean reduction of 16.80%. An ablation on OnePlus demonstrates the benefit of spatially aligned semantic guidance, and visual comparisons illustrate improved reconstruction of local structures.

0.34

Cross-View and Cross-Time Tracking of Crack Evolution in Concrete

eess.IV cs.CV ·2026-10-24 ·Pengru Deng, Jiapeng Yao, Su Wang, Xuhui He, Zhao Wang +3 more
Abstract · 50 pages. Author manuscript

Crack propagation provides richer information than static crack observations for evaluating structural conditions of concrete infrastructure and planning maintenance strategies. Unlike static crack detection, which can now be largely automated using computer vision, vision-based crack tracking is a coupled cross-view and cross-time problem: the same physical crack must retain its identity as camera viewpoints change, while newly developed growth must be distinguished from existing crack segments in a unified reference view. Existing segmentation and 3D reconstruction methods can recover crack masks or scene geometry, but they do not preserve crack identity across views or quantify temporal extension. To address this gap, this study formulates crack growth monitoring as a cross-view and cross-time crack-instance tracking task and proposes a geometry-assisted, morphology-aware framework. The framework first uses image-based geometric registration to align observations from different viewpoints into a shared structural reference, then applies morphology-aware instantiation to assign physically interpretable crack identities, and finally performs temporal mapping in the unified view to distinguish newly developed growth from existing crack segments. To enable evaluation, a temporally annotated dataset was established and used, covering three representative cracking scenarios: single dominant crack propagation, mixed-mode branching, and multiple-crack interaction, with pixel-level masks and cross-time instance labels. Experimental results show that the proposed framework can establish loose cross-view identity correspondence under changing viewpoints, while strict spatial overlap and growth localization remain limited by early micro-crack segmentability and projection drift, highlighting directions for future crack-monitoring research.

0.25

Complex Domain Inverse Problem Formulation for 4D Flow MRI Super-Resolution

eess.IV ·2026-10-24 ·Aurélien de Turenne, Denis Kouamé
Abstract · 5 pages

Four-dimensional flow magnetic resonance imaging measures blood velocity fields in three dimensions throughout the cardiac cycle and is increasingly used to assess hemodynamics. However, these measurements are limited by low signal-to-noise ratios and limited spatial resolution, which can compromise their accuracy and reliability. To address these limitations, we investigate the feasibility of spatial resolution enhancement through a complex-domain inverse problem formulation inspired by MRI acquisition principles. Three inversion methods are evaluated: a closed-form approach (FSR), a Plug-and-Play alternating direction method of multipliers (PnP-ADMM), and a pretrained network that takes the forward operator as input (RAM). On simulated data, all three methods outperform 4DFlowNet at x2 and x4 super-resolution factors. On aortic phantom data at x2 super-resolution, PnP-ADMM and RAM achieve lower root-mean-square error than 4DFlowNet in almost all cases. These results highlight the potential of the proposed formulation and support further development and validation.

0.25