2026-11-13 · physics.med-ph

2 papers first submitted this day (UTC) in physics.med-ph — physics.med-ph. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 1

Reproduction of Simulated Acoustics Scenes Using Acoustics Room Transformer for speech intelligibility tests in Clinics

eess.AS physics.med-ph ·2026-11-13 ·Ali Fallah, Kirsten C Wagener, Pascal Pflueger, Steven van de Par
Abstract · This paper is submitted to Acta Acustica and is currently under review

An Acoustic Room Transformation (ART) method is proposed for clinical applications to render simulated acoustic environments using six loudspeakers in a reverberant room. In typical clinical settings, testing rooms are not acoustically treated and only a limited number of loudspeakers are available. The ART approach enables control of the playback-room reverberation, allowing speech intelligibility tests to be performed under realistic and perceptually compensated conditions. The method focuses on the two most common Speech Reception Threshold (SRT) configurations: S0N90 and S0N90. One front and one side loudspeaker reproduce the direct sound components, while the remaining four loudspeakers (two in front and two behind the listener) generate the reverberant sound field. The direct sound is optimized in terms of energy, and the reverberant field is adjusted based on both energy and interaural coherence. An additional direct-sound gain is applied to match the clarity index (C50) of the reproduced signals to that of the reference target. Results from speech intelligibility tests demonstrate that, with ART processing, the reproduced scenarios achieve SRT values very close to those of the reference signal in both S0N0 and S0N90 conditions and therefore allow for comparable speech test results independent of the particular test room acoustics.

0.26

People & Society 1

Certificate-Based Verification of Pulsed Field Ablation Models

cs.CE math.NAphysics.med-ph ·2026-11-13 ·Konstantinos Dovelos
theoryunusual
Abstract · 18 pages, 5 figures, 7 tables

Computational models of pulsed field ablation predict the lesion as the tissue where the electric field exceeds a lethal threshold. Their numerical error is rarely bounded, and automated pipelines increasingly run them without an expert checking each result. To verify each run, we separate the question "was the stated model solved correctly?" from the solver that answers it. An untrusted solver returns with its answer a certificate, consisting of a potential with the correct electrode and ground values and an exactly charge-conserving current. A small independent checker verifies the certificate against a written specification of the physics. Using the Prager-Synge hypercircle theorem evaluated in ball arithmetic, it turns the certificate into guaranteed two-sided bounds on the impedance and on the root-mean-square field of every tile of a lesion map, also over a range of blood/tissue conductivity ratios. A vectorized version of the checker takes about a tenth of the solve time. For a focal electrode in contact, the tile-resolved depth at 1000 V and 700 V/cm is proven to lie in 3.50-3.75 mm for every ratio from 1.7 to 3.75. For a bipolar catheter, certified depths overlap published in-vivo depths. Where they differ from a published reference model, the certificates prove that the difference is not numerical error in our computation. We compare the certificate with a grid convergence study on the same solver. On graded grids the study is sharper for local fields but remains an estimate. On uniform grids it fails to converge at the electrode edge, where the certificate still gives a valid bracket. Solvers that deliberately solve equations other than the specified ones pass the grid convergence study, but the certificates refute their claims or leave them unsupported.

0.42