CS Paper Radar

Daily listing

2026-10-14 · q-bio.NC

4 papers first submitted this day (UTC) in q-bio.NC — q-bio.NC. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

AI & Machine Learning 2

How Long Is the Coast of a Neuron? Resolution-Dependent Interaction Order and Computational Capacity

cs.NE q-bio.NCcond-mat.dis-nncond-mat.stat-mech+1 ·2026-10-14 ·Nima Dehghani
unusual
Abstract

Mandlebrot's coastline paradox reframes measurement as a joint property of an object and its ruler. Here we ask how observational resolution shapes the apparent structure of neural computation. We introduce a scale-indexed decomposition that separates the predictive information captured by direct dependencies from the residual outside that model family. Exact constructions show that projection can convert higher-order dependence into pairwise structure. Projection can increase the direct fraction of surviving information even as total predictive information decreases. A schematic branch-to-soma cascade grounds these effects in local coincidence detection, saturating integration and somatic mixing. Resolving organized nonlinear subunits improves approximation and raises effective representational rank. In a nested hierarchy, these gains occur without increasing information about the target. This distinction separates information availability from access by a restricted readout. A point-neuron or direct population model therefore establishes an effective description at a specified scale. It does not uniquely identify the finer computation that generated the observed relation. Which resolution is adequate depends on the observable and perturbation of interest.

0.41

Semantic Alignment of EEG and Text: A Contrastive Learning Framework for Decoding Imagined Speech

cs.LG q-bio.NC ·2026-10-14 ·Shahryar G. Namdari, Francesco Iacomi, Riccardo Barbieri, Luca Mainardi
Abstract

Imagined speech decoding from EEG offers a promising route toward naturalistic brain-computer interfaces. Traditional closed-set classifiers treat semantic categories as independent labels and do not explicitly exploit relationships among linguistic intents, limiting output flexibility. We adapt a multimodal contrastive learning framework to imagined speech, aligning EEG trials with language representations in the embedding space of a frozen pretrained text encoder. An EEG encoder is trained with a composite objective combining semantically reweighted EEG-sentence alignment and text-prototype-based class discrimination, encouraging semantic structure while preserving separability among 39 intent categories. We evaluate the approach on the Chisco imagined speech dataset across five subjects, reporting Top-k accuracy, macro-F1, and balanced pairwise matching accuracy (2v2). We also investigate maximum EEG-text cosine similarity (MaxCosine) as an intrinsic indicator of decoding reliability and probe semantic structure beyond category labels using five evaluation-time semantic axes and a qualitative Semantic Gallery Probe (SGP) with previously unseen candidate sentences. The contrastive framework achieved decoding performance comparable to a task-optimized closed-set classifier while mapping EEG into a frozen language embedding space. MaxCosine identified subsets of held-out trials with higher Top-1 and Top-5 accuracy across subjects. Evaluation-time semantic axes showed mean agreement above the 50% chance reference across all five dimensions, and the SGP qualitatively illustrated direct comparison with unseen candidate sentences. Together, these findings suggest that EEG-language alignment can retain comparable fixed-intent decoding while supporting similarity-based retrieval, intrinsic reliability ranking, and evaluation of broader semantic structure.

0.09

Robotics, Control & Signals 2

How large an effect would we have seen? Positive controls, detection floors and dataset pitfalls in scalp-EEG speech decoding

eess.SP q-bio.NCq-bio.QM ·2026-10-14 ·Blessing Isoyiza Adeika, Onyema Osuagwu
Abstract · 22 pages, 4 figures, 8 tables plus supplementary tables. To be submitted to Journal of Neural Engineering

Objective. Studies that decode imagined speech from scalp electroencephalography (EEG) commonly validate their pipelines with a positive control, usually overt speech, and report null results without stating what effect size the pipeline could have detected. Approach. Using ds003626 ("Thinking out loud"), KaraOne and Track 3 of the 2020 International Brain-Computer Interface Competition, we audited decoding of overt speech, articulator preparation and imagined speech with artifact-channel subsets, band-limited decoding and trial selection, under a protocol that enforces split integrity by assertion. We injected class-dependent effects of known amplitude into the real recordings to measure the detection floor of five decoder families, and we checked the ds003626 labels against the dataset's acquisition protocol. Main results. On ds003626, two lip electrodes decoded overt speech at 0.7430 and the eight external channels at 0.7068, against 0.4231 for the 128-channel scalp montage, and no decodable signal survived in the 8-30 Hz band. On the other two corpora, within-subject accuracy rose monotonically with frequency into the range dominated by muscle activity. Band-power logistic regression detected an injected 8-30 Hz desynchronization of 0.54 uV under a criterion fixed in advance, whereas a compact convolutional network (EEGNet) detected nothing within subject up to 4.31 uV. In ds003626, the condition codes are the reverse of the intuitive reading, the class encoding changed between public releases, and condition is a deterministic function of time within each session. Significance. In these corpora the overt-speech positive control is dominated by myogenic signal and cannot validate a decoding pipeline. We recommend that speech-decoding studies report band-limited and artifact-channel accuracy, the direction of accuracy across frequency, and a measured detection floor.

0.38

Cross-subject decoding of imagined speech from scalp EEG: a leakage-controlled evaluation on three public corpora

eess.SP cs.LGq-bio.NC ·2026-10-14 ·Blessing Isoyiza Adeika, Onyema Osuagwu
Abstract · 23 pages, 5 figures, 10 tables plus supplementary tables. To be submitted to Journal of Neural Engineering

Objective. A decoder of imagined speech that works for a new user without calibration would make a non-invasive speech interface practical. We tested whether imagined-speech content recorded with scalp electroencephalography (EEG) transfers across people, and examined why accuracy within a single person remains low. Approach. We analyzed three public corpora, ds003626, KaraOne and Track 3 of the 2020 International Brain-Computer Interface Competition, under a protocol that enforces split integrity by assertion and reports exact binomial thresholds, group tests and bootstrap confidence intervals. We trained decoders on each participant and tested them on every other, compared representational geometry across participants without a classifier, applied subject-level alignment, and tested five explanations for the within-subject ceiling. Main results. Across 482 ordered pairs of participants, no pair survived correction for multiple comparisons; mean pair-transfer accuracy lay within 0.006 of chance on every corpus, while every within-subject reference lay above it. Imagery against pre-stimulus rest generalized at about 0.61 after artifact and elapsed-time controls, but its decoder labelled the interval preceding imagery as imagery as often as imagery itself, so the contrast reflects a post-stimulus state, not imagery. Within subject, only the competition corpus decoded above threshold for every participant (0.3147; chance 0.200); syllable count explained little of this, but its frequency profile failed an artifact audit. Significance. In these corpora, imagined-speech content did not transfer between people through any representation we examined. Trial count per class was the only variable that ordered the corpora, which favors larger single-condition datasets over further model development.

0.33