CS Paper Radar

Daily listing

2026-11-11 · q-bio.QM

3 papers first submitted this day (UTC) in q-bio.QM — q-bio.QM. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

AI & Machine Learning 2

Subject-Held-Out Evaluation of Deep Ground Reaction Force Estimators Across Two Laboratories: Leakage and Cross-Laboratory Transfer

cs.LG eess.SPq-bio.QM ·2026-11-11 ·Hernan David Santos, Yinong Chen, Yu Ding, Xudong Zhang, Jian Tao
code/data
Abstract · 15 pages (9 main + 6 supplementary), 5 figures. Submitted to IEEE Journal of Biomedical and Health Informatics. Code and run outputs: https:…

Deep networks that estimate ground reaction forces and centers of pressure from motion-capture markers are validated within one laboratory, in a seldom-stated coordinate frame, and sometimes with trial-level splits that put the same person in the training and the test set. We measured what each practice costs, and whether such models transfer between laboratories. Three sequence models (convolutional, convolutional-recurrent, and convolutional-transformer) were evaluated on two independent datasets, locomotion (6 subjects) and occupational patient handling (10 subjects), under one pipeline, one tuning procedure, three seeds, and four protocols: trial-level split, leave-one-subject-out, pooled two-laboratory training with matched held-out subjects, and cross-laboratory transfer. At a fixed configuration, trial-level splits overstated the subject-held-out coefficient of determination by +0.040 to +0.194; on occupational data the overstatement exceeded every difference between architectures. With subjects held out, the three models reached values between 0.583 and 0.804; the leader differed between datasets, and gaps lay within subject-to-subject variability. Pooling the laboratories changed neither dataset on matched subjects. Transfer between laboratories was below chance in both directions, including the vertical force, which no in-plane rotation can affect. Leaving force targets in the plate frame while inputs were heading-aligned cost 0.57 of locomotion anteroposterior-force explained variance, enough to make that force look hardest; a Newton's-law correlation detected the mismatch before training. Split protocol and target frame changed reported accuracy more than architecture did. Learned force estimators should be validated with subjects held out, checked for frame consistency before training, and tested across laboratories before deployment claims are made.

0.37

PDO Drug Screening Data for Evaluating and Training AI Drug Response Prediction Models

cs.AI q-bio.QM ·2026-11-11 ·Y. Zhu, K. Marlor, V. Lavelle, T. S. Brettin, M. Sacco +4 more
code/data
Abstract

Anti-cancer drug response prediction (DRP) is critically important for precision oncology and therapeutic development. Currently, most DRP models are developed using drug screening data from immortalized cancer cell lines, which can differ substantially from patient tumors at the genomic and molecular levels, even though patient tumor response is the ultimate prediction target. To help bridge this gap and bring DRP models closer to their intended clinical application, we conducted four drug screening studies using patient-derived organoids (PDOs), which more faithfully recapitulate patient tumors than immortalized cell lines. These studies generated data for improving and evaluating DRP models, including multi-omics profiles of PDO lines, drug feature data, and treatment response measurements. Using these data, we retrained and evaluated multiple publicly available DRP models under three model-building scenarios: training models using cell line data only, training models using combined cell line and PDO data, and pretraining models on cell line data followed by fine-tuning on PDO data. We then evaluated and compared model prediction performance on PDOs across these analysis scenarios. In addition, we also assessed the consistency of drug screening viability data generated by different laboratories using different assay technologies and/or experimental protocols.

0.36

Robotics, Control & Signals 1

Robot-Induced Bias in Movement Smoothness Metrics for Rehabilitation: Quantification and Correction in Simulation

cs.RO q-bio.QM ·2026-11-11 ·David Regev, Alex Scherbakov, Eran Beeri Bamani
benchmark
Abstract · 7 pages, 4 figures, 2 tables. Submitted to the 2027 IEEE International Conference on Rehabilitation Robotics (ICORR)

Robot mechanics can bias kinematic measures of recovery and limit comparisons across rehabilitation devices. We developed a closed-loop human-robot simulation calibrated to published healthy and stroke group kinematics. Paired runs held motor-control parameters and movement plans fixed to quantify bias in seven metrics relative to a low-impedance reference, normalized using external repeatability benchmarks. Within a subset informed by published device specifications, median log dimensionless jerk (LDLJ) bias was 0.93 and 1.79 benchmark units for stroke and healthy profiles, respectively. Sobol analysis identified Coulomb friction and apparent mass as leading contributors; LDLJ bias persisted across 11 robustness variants. LDLJ bias increased as simulated movements became less fragmented. If recovery similarly reduces fragmentation, this effect could partly mask improvement in measured smoothness. Correction combining identified robot dynamics and observed metrics with gradient-boosted trees reduced median normalized absolute error from 0.77 to 0.10 for LDLJ and from 0.24 to 0.08 for spectral arc length (SPARC) in the device-informed subset of a random 20% hold-out. Median smoothness residuals remained at or below 0.15 benchmark units across four separately held-out parameter regions. Under an alternative controller, LDLJ error decreased from 1.60 to 0.17 without retraining, although transfer varied across metrics. These simulation results support mechanical characterization and movement-dependent correction toward more comparable robotic assessments, motivating validation in patients.

0.26