CS Paper Radar

Robot-Induced Bias in Movement Smoothness Metrics for Rehabilitation: Quantification and Correction in Simulation

David Regev, Alex Scherbakov, Eran Beeri Bamani

cs.RO q-bio.QM ·submitted 2026-11-11 17:24 UTC · v1
benchmark

Abstract

Robot mechanics can bias kinematic measures of recovery and limit comparisons across rehabilitation devices. We developed a closed-loop human-robot simulation calibrated to published healthy and stroke group kinematics. Paired runs held motor-control parameters and movement plans fixed to quantify bias in seven metrics relative to a low-impedance reference, normalized using external repeatability benchmarks. Within a subset informed by published device specifications, median log dimensionless jerk (LDLJ) bias was 0.93 and 1.79 benchmark units for stroke and healthy profiles, respectively. Sobol analysis identified Coulomb friction and apparent mass as leading contributors; LDLJ bias persisted across 11 robustness variants. LDLJ bias increased as simulated movements became less fragmented. If recovery similarly reduces fragmentation, this effect could partly mask improvement in measured smoothness. Correction combining identified robot dynamics and observed metrics with gradient-boosted trees reduced median normalized absolute error from 0.77 to 0.10 for LDLJ and from 0.24 to 0.08 for spectral arc length (SPARC) in the device-informed subset of a random 20% hold-out. Median smoothness residuals remained at or below 0.15 benchmark units across four separately held-out parameter regions. Under an alternative controller, LDLJ error decreased from 1.60 to 0.17 without retraining, although transfer varied across metrics. These simulation results support mechanical characterization and movement-dependent correction toward more comparable robotic assessments, motivating validation in patients.

Comment
7 pages, 4 figures, 2 tables. Submitted to the 2027 IEEE International Conference on Rehabilitation Robotics (ICORR)

Closest papers

Nearest neighbours by meaning across the whole index.

Does Haptic Connection to a Healthy Partner Improve Motor Learning in Chronic Stroke? A Pilot Study of Robot-Based Dyadic Training

cs.RO cs.HC ·2026-11-09 ·Erica L. Waters, Natalia Stroutinsky-Sobotka, Reem M. Azar, Frances S. Shofer, Pamela Z. Cacchione +2 more
similarity 0.65
Abstract

Purpose: Robot-based haptic dyads, where two users exchange forces through robots, have been proposed for robot-assisted neurorehabilitation. This intervention could increase motor learning by promoting motor variability, providing an implicit communication channel, and facilitating social interaction. Despite the potential benefits, few studies have investigated robot-based haptic dyads for neurological populations, and none have included a comprehensive clinical assessment. Design/Methodology/Approach: We present a pilot study investigation of individuals with chronic stroke learning a complex tracking task in solo and dyad conditions. Prior to training, participants completed a battery of cognitive, motor, and sensory assessments. We assessed changes in key kinematic outcomes including tracking error, distance traveled, mean absolute power, and sample entropy. We also performed a correlation analysis of clinical scores with baseline tracking errors. Findings: Baseline tracking error was strongly correlated (r > 0.6) with lower cognitive scores and higher motor scores. Only the solo group demonstrated lower tracking error at assessment (Δ = -5.33, 95%CI [-10.25, -0.40], p = 0.027), but this result was tempered by the removal of an outlier participant. Neither group demonstrated clear retention. The dyad group showed significantly elevated performance, effort, and movement complexity during training. Research Limitations/Implications: The selected task was too difficult to reveal learning for either group, which may be related to its high cognitive demand. Sample size and stroke heterogeneity were also limitation. Originality/Value: Dyadic training increased movement complexity and effort, which are associated with better motor learning. Clinical characteristics such as lesion location, cognition, sensation, and chronicity may influence potential benefits of dyadic training.

0.21

Transformer-Based Trajectory Prescription for sEMG-Optimizing Robot-Mediated Rehabilitation

cs.RO cs.HCcs.LG ·2026-11-05 ·Gabriel Parra, Kimia Khoshnami, Daniel S. Brown, Laura A. Hallock
publishedcode/data similarity 0.64
Abstract · Accepted for presentation and publication in the 2026 Conference on Robot Learning (CoRL). PMLR, 2026

Robot-mediated rehabilitation has the potential to deliver high-intensity, individualized therapy, but existing systems (which have not consistently improved outcomes) typically prescribe kinematic trajectories rather than explicitly targeting the neuromotor activations thought to support recovery. To address this gap, and ultimately enable activation-optimizing rehabilitation robot behavior, we present a personalizable transformer-based model mapping individuals' muscle activations (as measured via surface electromyography) to prescribed contact force trajectories when interacting with an end-effector rehabilitation robot. The model uses a transformer encoder-decoder leveraging rotary positional embeddings (RoPE) to generate a latent representation of trajectory-relevant and user-specific neuromotor factors, and augments trajectory prediction with flow matching to produce a distribution over plausible prescriptions biased toward the training distribution. Using data from 16 healthy participants completing 15 isometric trajectory tracking tasks, we evaluate generalization across held-out tasks and users, as well as the feasibility of user-specific fine-tuning within a therapy-session timescale. The model achieves mean trajectory prediction errors of <8% on held out tasks and users, with effectively instantaneous deterministic inference and sub-second sampling of trajectory distributions. An initial test using the model during live rehabilitation tasks demonstrates that, on average, participants reach the target neuromotor activations with just 15% error accumulated throughout the task. These results provide a proof of concept for data-driven, activation-targeted trajectory prescription in robot-mediated rehabilitation and establish a foundation for future validation in clinical populations. Data and code have been open-sourced as part of the OpenRobotRehab project on SimTK.

0.34

Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury

cs.CV ·2026-10-04 ·Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland +1 more
datasetcode/data similarity 0.60
Abstract

Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements (r = 0.68-0.90, p < 0.001, and RMSE = 4.18-6.49 degrees), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates (r = 0.85-0.87, p < 0.001, and RMSE = 2.13-2.19 Newton per kg). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury. Github: https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset

0.30

Beyond Cross-Modal Reconstruction: Participant-Level Evaluation of sEMG-Kinematic Coupling in Post-Stroke Gait

cs.LG ·2026-11-18 ·Rafsan Jany, Md Rafid Islam, Mohammad Fahim Islam, Hafiz Abdur Rahman
similarity 0.57
Abstract

Accurate cross-modal reconstruction is often treated as evidence of physiological coupling, although it may simply reflect temporal patterns shared across participants. We tested whether frozen bidirectional models captured subject-specific neuromuscular coupling between electromyographic activity and gait kinematics in 82 held-out able-bodied and 43 post-stroke participants. Complete source-modality removal and cross-participant source substitution, along with a cycle-position-age-sex template baseline, were applied. Learned bilateral asymmetry was also compared with transparent waveform and derivative asymmetry for predicting Performance-Oriented Mobility Assessment (POMA) scores in the case of repeated nested cross-validation. Complete source removal increased reconstruction RMSE by 6.90% for electromyography-to-kinematics and 11.38% in the reverse direction. In contrast, cross-participant substitution increased RMSE by only 1.68% and 1.67%, respectively, while the template reduced RMSE by 2.89% and 0.55%. For POMA prediction, walking speed, age, and sex achieved an MAE of 3.693, compared with 4.229 and 4.427 after adding absolute and signed learned asymmetry, respectively. In all of the 20 repeated evaluations, all asymmetry representations performed worse than the covariate baseline. No localized learned feature remained significant after covariate adjustment and false-discovery-rate correction. The model mainly relied on shared gait-phase patterns, with no clear subject-specific coupling or added clinical value. Participant-level controls are therefore needed before reconstruction accuracy is treated as evidence of individualized physiology.

0.20

Beyond Kinematics: Benchmarking Simulation Fidelity for Muscle-Driven Imitation Learning

cs.LG cs.RO ·2026-09-18 ·Ayah G. Ahmad, Claire E. Borden, Maegan Tucker
hot direction similarity 0.57
Abstract · 8 pages, 5 figures, 2 tables, submitted to ICRA 2027

In this work, we conduct a systematic comparison of two state-of-the-art motion-imitation reinforcement learning (MIRL) pipelines, one built on SCONE/HyFyDy and one built on MuJoCo/MyoSim. HyFyDy emphasizes physiological realism through detailed musculotendon modeling, while MuJoCo prioritizes computational efficiency and scalable policy learning. While recent work has demonstrated that both pipelines reproduce human kinematics with high fidelity, it remains unclear if they accurately capture the underlying neuromuscular behavior that produced the movement. This limitation is particularly important for robotic assistive-device design and control, where outcome measures such as muscle activation patterns and metabolic cost are often used as optimization targets. To conduct a systematic comparison, our work compares both pipelines using a common set of human motion-capture and electromyography (EMG) measurements. The results find that while both pipelines produce similar kinematics with relative accuracy, the muscle activations from HyFyDy are more aligned with the experimental EMG, as supported by the average pooled (RMSE, r) values for muscle activations from HyFyDy and MuJoCo: (0.164, 0.4) and (0.344, 0.11), respectively. While we conclude that the more advanced physiological realism of HyFyDy currently makes it more suitable for musculoskeletal modeling, both require further development to bring physiological realism to GPU-parallelizable simulation environments and advance robotic assistive device design.

0.35

Generative Action-Chunk Sampling for Adaptive Stiffness Control in Physical Human-Robot Collaboration

cs.RO cs.AIcs.LG ·2026-08-26 ·Aoi Otake, Ferdinand Hartmann, Ko Igari, Shingo Murata
similarity 0.57
Abstract · Preprint version

Physical human-robot collaboration requires a robot to provide assistance when human intention is clear while remaining compliant when several future motions are plausible. We present an adaptive stiffness framework based on generative action-chunk sampling. Conditioned on an RGB image and external joint-torque estimates, the policy samples multiple latent variables from an observation-conditioned prior and decodes them into future action chunks. Variation among the sampled action chunks is used to continuously adapt joint stiffness and damping. Greater variation makes the robot more compliant to facilitate human guidance, whereas lower variation provides firmer assistance. In a real-world collaborative transport task with four possible directions, the proposed method achieved an average success rate of 0.95, compared with 0.83 for a fixed-stiffness ablation and 0.69 for a deterministic baseline. Near direction determination, variation among the sampled action chunks increased, and the controller reduced stiffness accordingly. These results suggest that variation among actions sampled by a generative policy can serve as an online control signal for balancing assistance and compliance in physical human-robot interaction.

0.11

Whole-Body Motion Guided Reference Generation for Uncertainty-Aware Compliant Assistance

cs.RO ·2026-10-22 ·Muyuan Ma, Long Cheng, Lijun Han, Haotian Zhai, Xinpan Meng +3 more
similarity 0.57
Abstract · Withdrawal requested because not all co-authors had consented to the submission of this manuscript to arXiv

Exoskeletons have shown great potential for augmenting human physical capabilities, yet generating reliable assistance remains challenging because human motion patterns and interaction requirements vary substantially in practice. To address this problem, a dual-loop assistance strategy is proposed to couple multimodal exoskeleton trajectory generation with variable admittance control, where trajectory variance links the outer-loop generator and the inner-loop controller. The generator synthesizes future exoskeleton trajectories through denoising, primarily using whole-body human motion and exoskeleton proprioception, with task descriptions as auxiliary semantic cues. To reduce cross-modal representation mismatch, a three-stage training pipeline is introduced to progressively optimize the human motion encoder, the exoskeleton proprioception encoder, and the trajectory generator. In the inner loop, multiple future trajectories are sampled from the generator to estimate the trajectory mean and variance. The mean is used as the control reference, while the variance provides an uncertainty measure for prediction reliability. This measure is further incorporated into a stiffness regulation law, enabling compliant assistance with input-to-state stability under bounded lumped interaction input. Experimental results demonstrate that the proposed method significantly reduces muscle activation levels compared with standard baselines, while also decreasing users' metabolic energy expenditure relative to the unassisted condition.

0.21

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.56
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.47