CS Paper Radar

Daily listing

2026-11-19 · q-bio.QM

3 papers first submitted this day (UTC) in q-bio.QM — q-bio.QM. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

AI & Machine Learning 1

Beyond Final Answers: Interpretable Tumor Immune Microenvironment Reasoning from H&E and mIF

cs.AI q-bio.QM ·2026-11-19 ·Yixuan Duan, Kexin Geng, Hanwen Xu, Wei Qiu
Abstract · 23 pages, 12 figures, 13 tables

Readouts of the tumor immune microenvironment (TIME), such as CD8+ T-cell density, intra-epithelial infiltration and the Ki67 index, combine tissue architecture from H&E with cell phenotypes from multiplex immunofluorescence (mIF). Multimodal large language models (MLLMs) could automate these readouts with an explanation, but two gaps remain. Pathology MLLMs read H&E alone, while these readouts need the cell phenotypes that mIF measures. And their reasoning has no step-level truth to be checked against, so R1-style reinforcement learning rewards only the final answer and leaves the reasoning unverified. Same-section H&E and mIF provide what both gaps lack: mIF measures every cell without manual annotation, which gives cell-level ground truth for each step that clinical guidelines prescribe, from delineating a tissue compartment to counting and normalizing the marker-positive cells within it. We therefore present HERMES (H&E-mIF Reasoning with Multimodal Evidence Supervision), an R1-style MLLM that reasons jointly over paired H&E and mIF in guideline steps and is trained with a process reward that checks every stated quantity against this truth. Across four field-level TIME tasks in colorectal cancer, HERMES (4B) reaches an average accuracy of 84.5%, compared with 74.7% for the strongest of twelve proprietary, general, medical and pathology MLLMs, and a higher share of its intermediate quantities is correct than for the strongest open-weight baseline. Without the process reward, reinforcement learning barely improves on supervised fine-tuning (80.0% vs. 78.8%) and fewer stated quantities are correct; editing a decisive stated quantity changes the answer as implied in all 885 test questions. Without retraining, it keeps the highest average accuracy on an external cohort imaged with CODEX (76.4% vs. 67.3%) and on head and neck cancer, a cancer type absent from training (76.7% vs. 72.5%).

0.30

Language, Vision & Media 2

When Foundation Models Disagree: Representational Heterogeneity for Calibrated Uncertainty in Whole-Slide Image Classification

cs.CV q-bio.QM ·2026-11-19 ·Yekai Shen, Yuqian Wang, Zishun Liao, Rongsheng Wang, Wenting Chen +2 more
published
Abstract · accepted by IEEE BIBM 2026

Pathology foundation models supply strong representations for whole-slide image classification, yet the confidence attached to their predictions remains hard to trust. Prevailing uncertainty estimators act within a single feature space and thereby overlook the uncertainty that the choice of foundation-model representation itself induces. This work introduces CALIFUSE, a calibration-oriented framework that fuses several pathology foundation models for the specific purpose of uncertainty estimation. Departing from accuracy-driven fusion, CALIFUSE reads representational heterogeneity across encoders as an explicit confidence cue. Slide-level decision consensus is coupled with chunk-level evidence agreement quantified through Jensen-Shannon divergence, so that both prediction stability and fine-grained evidence consistency inform the estimate. Foundation-model encoders stay frozen. A task-specific nnMIL classifier is still trained for each FM; CALIFUSE then estimates confidence at inference without training an extra fusion module. Evaluated on seven WSI classification tasks under several foundation-model combinations, the framework sharpens calibration, misclassification detection, and selective prediction relative to both the strongest single-encoder baseline and naive ensemble averaging, all while preserving competitive balanced accuracy.

0.36

MambaSplit: Severity-Robust and Inference-Efficient Semantic Unmixing of Fluorescence Microscopy Image Data

eess.IV cs.CVq-bio.QM ·2026-11-19 ·Aman Kukde, Ruggiero Santeramo, Federico Carrara, Ashesh Ashesh, Igor Zubarev +1 more
Abstract · 28 pages, 15 figures, 23 tables; main paper (8 pages) followed by supplementary material

The number of structures fluorescence microscopy can image in one sample is limited by how few fluorophores can be separated without significant spectral overlap. Semantic unmixing circumvents this limit by imaging two structures in one fluorescent channel and computationally separating the superimposed image into one image per structure. Because pixels rarely identify their structure, unmixing requires both local and long-range spatial context. The relative brightness of the two structures is unknown and can be very uneven, so predictions must remain accurate across mixing severities, from balanced mixtures to ones where a structure is barely visible. Existing methods either process small image patches or add context through auxiliary pathways that slow inference on large images. We present MambaSplit, a hierarchical state-space encoder with a convolutional decoder that captures context across large tiles in linear time and predicts both channels in one deterministic pass. MambaSplit trains either on computationally summed channel images with random mixing ratios, where a lightweight head estimates the unknown ratio and conditions the decoder on it, or on experimentally acquired superpositions. Across five datasets and nine mixing ratios, MambaSplit achieves the highest RI-PSNR, by up to 3.0 dB, in 11 of 15 dataset-severity combinations and ties in one more, while running 5.9x faster than the strongest baseline. On acquired superpositions, fine-tuning a model pretrained on summed inputs matches or exceeds all baselines. Ablations show that accuracy and robustness come mainly from the training recipe: large tiles, mixing ratios sampled across their full range (up to 11 dB over fixed-ratio training), and independently drawn channel crops (3.9 dB on BioSR). The state-space backbone makes large tiles affordable, enabling high-content screening and event-driven smart microscopy.

0.27