CS Paper Radar

When Foundation Models Disagree: Representational Heterogeneity for Calibrated Uncertainty in Whole-Slide Image Classification

Yekai Shen, Yuqian Wang, Zishun Liao, Rongsheng Wang, Wenting Chen, S. Kevin Zhou, Qingsong Yao

cs.CV q-bio.QM ·submitted 2026-11-19 14:15 UTC · v1
published

Abstract

Pathology foundation models supply strong representations for whole-slide image classification, yet the confidence attached to their predictions remains hard to trust. Prevailing uncertainty estimators act within a single feature space and thereby overlook the uncertainty that the choice of foundation-model representation itself induces. This work introduces CALIFUSE, a calibration-oriented framework that fuses several pathology foundation models for the specific purpose of uncertainty estimation. Departing from accuracy-driven fusion, CALIFUSE reads representational heterogeneity across encoders as an explicit confidence cue. Slide-level decision consensus is coupled with chunk-level evidence agreement quantified through Jensen-Shannon divergence, so that both prediction stability and fine-grained evidence consistency inform the estimate. Foundation-model encoders stay frozen. A task-specific nnMIL classifier is still trained for each FM; CALIFUSE then estimates confidence at inference without training an extra fusion module. Evaluated on seven WSI classification tasks under several foundation-model combinations, the framework sharpens calibration, misclassification detection, and selective prediction relative to both the strongest single-encoder baseline and naive ensemble averaging, all while preserving competitive balanced accuracy.

Comment
accepted by IEEE BIBM 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Do Center Biases Propagate? Robustness of Pathology Foundation Models in Whole-Slide Image Classification

cs.CV cs.AI ·2026-09-23 ·Ilán Carretero, Pablo Meseguer, Rocío del Amor, Valery Naranjo
benchmark similarity 0.71
Abstract · Submitted to CASEIB'26

Pathology foundation models (PFMs) have transformed computational pathology through powerful representation learning from histopathological images. PFMs provide rich, discriminative representations for whole slide image (WSI) analysis, enabling tasks such as slide-level classification under multiple instance learning (MIL). However, these representations may also encode non-biological signals associated with acquisition centers, potentially introducing spurious shortcuts into downstream predictions. In this work, we evaluate center-associated robustness in WSI classification using a controlled training setting with increasing class-center correlations quantified by Cramér's V. We benchmark six PFMs across four datasets and two MIL aggregators, while evaluating ComBat as a robustification strategy. We further introduce the Area Under the Cramér's V Curve (AUCC) to jointly capture absolute classification performance and its degradation as spurious correlation increases. Results show that center-related information encoded by PFMs propagates to WSI-level predictions, with robustness depending on both the PFM representation and MIL aggregation strategy. Additionally, ComBat harmonization does not provide consistent robustness gains across datasets.

0.28

SCOUT: Risk-Guided Foundation-Model Escalation for Robust Tissue Detection in Whole-Slide Images

cs.CV ·2026-11-18 ·Cristian Tommasino, Antonio M. Rinaldi
benchmarkcode/data similarity 0.68
Abstract

Reliable tissue detection is essential for whole-slide image analysis, yet high average segmentation accuracy can conceal failures involving pale tissue, small fragments, and heterogeneous staining. Pathology foundation models offer transferable representations, but exhaustive inference is computationally demanding and may introduce false-positive tissue predictions. We propose SCOUT (Selective Correction of Uncertain Tissue), a risk-guided cascade that selectively refines an initial thumbnail-based tissue mask. A lightweight audit network estimates the spatial distribution of segmentation errors and prioritizes candidate regions for processing by a frozen pathology foundation model. An asymmetric consensus rule integrates the resulting predictions with the initial mask to recover missed tissue while limiting false positives. A calibrated slide-level review score additionally controls the marginal rate of unflagged case-group failures under the calibration assumptions. Evaluation on a public multi-source, multi-stain benchmark shows that SCOUT reduces the proportion of case groups requiring mask correction from 38.1% for the best released detector to 18.6%, with particularly pronounced improvements in immunohistochemistry. Source-held-out experiments demonstrate better generalization than a segmentation network trained on the same annotations, while selective inference achieves an observed failure rate no higher than processing all candidate regions. Downstream, lymph-node classification with SCOUT masks is non-inferior to that obtained with two of the three released detectors evaluated. A variant built on an openly licensed foundation model is publicly released as an installable Python package with trained weights. These results support risk-guided foundation-model inference as an effective approach to tissue detection across heterogeneous histopathology data.

0.28

Role-Guided MOE for Encoder-Level Pathology Representation Learning in WSI Classification

cs.CV ·2026-09-28 ·Xinyu Ma, Xing Yang, Hongtao Jin, Guoquan Zhang, Shijie Zhang +2 more
similarity 0.68
Abstract

Whole slide image classification is a fundamental task in computational pathology, where patch representation quality directly affects downstream aggregation and slide-level discriminability. Pathology foundation models are widely adopted as frozen feature extractors for WSI classification; however, their fixed encoders may produce representations insufficiently adapted to target-specific tissue patterns and discriminative cues. Fine-tuning can improve target adaptation, but introduces a trade-off between pathology-specific representation capacity and adaptation efficiency, particularly in data-scarce settings. To address this, we propose a pathology role-guided mixture-of-experts feed-forward network (MoE-FFN) framework for efficient encoder-level representation learning. We design a two-stage training paradigm to establish and adapt pathology-aware expert specialization. In source-domain expert initialization, pathology-specific priors are distilled from a frozen Virchow2 teacher into a lightweight DINOv2-small student, while role prototypes serve as weak pathological anchors to encourage distinct expert functions. MoE-FFN blocks are introduced into selected high-level transformer layers to provide transformation diversity for heterogeneous pathological patterns. In target-domain adaptation, the initialized experts are refined through asymmetric prototype-guided optimization, enhancing task-relevant positive evidence and separating confusable hard negatives. The resulting encoder extracts offline patch representations that can be directly integrated with standard MIL aggregators. Experiments on the public BRACS dataset and a private PAROTID WSI dataset across five representative backbones demonstrate consistent improvements over the strongest baseline.

0.12

HERO: Histology Encoder for Robust Representation in Oncology

cs.CV ·2026-09-28 ·Zhi Li, Eghbal Amidi, Yating Cheng, Tyson Dawson, Gorkem Can Ates +9 more
benchmarkcode/data similarity 0.66
Abstract · 22 pages, 4 figures, 13 tables; author information updated; scientific content unchanged

Foundation models trained on large pathology image corpora now provide strong, transferable representations for computational pathology. Over the past few years a series of such models has been released, each trained on more slides than the last; on standard classification and segmentation benchmarks, the leading models are now separated by small margins. In clinical use, however, the foundation model is applied to images from hospitals, scanners, and staining protocols outside its training data. Encoders generally embed these acquisition factors alongside biological information, which may introduce downstream errors and hinder safe clinical adoption. A pathology foundation model should therefore be robust to acquisition shift without giving up representation quality, yet robustness is seldom the axis along which models are compared. In this report, we introduce HERO (Histology Encoder for Robust Representation in Oncology), a ViT-G/14 pathology foundation model trained with the DINO and iBOT objectives and refined with high-resolution Gram anchoring on a morphology-balanced corpus of 500 million tiles from approximately 575,000 clinical whole-slide images. Across the evaluated public benchmarks, HERO shows the strongest robustness to center, scanner, and stain variation among the compared state-of-the-art foundation models, performs comparably on tile-level classification, segmentation, and gene-expression prediction, ranks first on average across 39 evaluated slide-level clinical tasks, and, under an equal-weighted framework-level analysis, has the best average rank across the six benchmark frameworks.

0.22

Morphology signal in whole slide image foundation models can automatically triage slides

cs.CV cs.LG ·2026-09-02 ·Ayushi Sinha, Shashank Yadav, Benjamin Holmes, Pravat Das, Aaron W. Bogan +7 more
benchmark similarity 0.66
Abstract · 12 pages, 3 figures, 4 tables

Patient exams in the cancer diagnosis and staging process typically generate several whole slide images (WSIs). One of the initial steps in training models on WSI data is identifying one or a few slides containing tumor or other diagnostic biomarkers necessary for downstream prediction tasks such as estimating recurrence risk or progression-free survival. This step requires tedious manual curation by experienced pathologists. Many published datasets make the artificial assumption of 1 slide per patient. Alternatively, all slides per patient may be used for model training, which may dilute the signal from the few slides containing tumor or other relevant information. In this paper, we present a pipeline to overcome these challenges using publicly available WSI foundation models (FMs). Our evaluations show that ranking WSIs based on predictions from zero-shot classification using WSI FMs accurately identifies slides with the most tumor, indicating that WSI FMs contain sufficient morphology signal to automatically triage slides. We also present a formulation for ranked evaluation to benchmark FM performance in slide triage. We show, on multiple datasets, that tumor slides are identified in the top-2 ranked slides for patients with up to 43 slides.

0.14

Multi-scale Fusion of Fast Vision Mamba and Foundation Model Features for Patch-Level Gleason Grading in Computational Pathology

cs.CV ·2026-10-19 ·Zihe Zhang, Weimiao Yu, Piumi Don Simonge
published similarity 0.66
Abstract · 13 pages, 4 figures and 4 tables (including supplementary), Accepted to COMPAYL workshop MICCAI 2026, Comments are welcome!

Automated Gleason grading of prostate whole slide images (WSIs) enables faster and more consistent cancer risk stratification. However, it remains a challenging task due to the subtle morphological differences between grades, the severe class imbalance arising from rare patterns, and the diagnostic features that span multiple spatial scales. Pathology foundation models (FMs) extract strong patch representations but often operate at a single-scale, which limits spatial context and disproportionately affects classes that depend on broader context. The challenge of fusing multiple scales and complementary models, with minimal data and computational resources, remains unresolved. We propose a multi-scale classifier built on state-space models. Our method combines two complementary feature sources: a frozen foundation model, and a lightweight FastVim, pre-trained on ImageNet and distilled from the foundation model, that reads the raw image crops. At each scale, a Mamba model encodes the features from both sources with linear-time spatial context, and a jointly trained head fuses the encoded representations into one prediction. On the PANDA dataset, our method reaches macro F1 of 0.894 and Gleason 5 F1 of 0.802 under 5-fold cross-validation, a 12% and 21% relative improvement over the best single-scale model. A controlled study over 5 foundation models, 5 base classifiers and 3 scales confirms that the gain holds across encoders, with larger improvements observed at smaller scales.

0.30

Uncertainty of Vision Medical Foundation Models

cs.LG ·2026-08-31 ·Haoxu Huang, Narges Razavian
similarity 0.66
Abstract

Accurate uncertainty estimation is essential for machine learning systems de- ployed in high-stakes domains such as medicine. Traditional approaches primarily rely on probability outputs from trained models (point predictions), which provide no formal guarantees on prediction coverage and often require additional calibra- tion techniques to improve reliability. In contrast, conformal prediction (region prediction) offers a principled alternative by generating prediction sets with finite- sample validity guarantees, ensuring that the ground truth is contained within the set at a specified confidence level. In this study, we explore the impact of pre-training approach, dataset scale and domain on both point and region-level uncertainty quantification, by studying domain-specific vision medical foundation models vs. general domain vision foundation models. We conduct a comprehensive evaluation across foundation models trained on retinal, histopathological, and Chest X-Rays data, applying various calibration techniques. Our results demonstrate that (1) pre-training on higher-quality domain-specific datasets along with self-supervised learning leads to better-calibrated point predictions than general domain pre-training, (2) stan- dard re-calibration methods alone cannot fully mitigate uncertainty discrepancies across models trained on different data sources, (3) domain-specific foundation model can lead to more efficient conformal prediction. These findings highlight the importance of careful model selection and the inte- gration of both point and region prediction to enhance the reliability and trust- worthiness of medical AI systems. Our work underscores the need for a holistic approach to uncertainty quantification in recent development of medical vision foundation model, ensuring robust and interpretable AI-driven decision-making.

0.06

Reliability analysis for BraTS-GoAT segmentation: a controlled robustness study of deep-ensemble uncertainty

cs.CV ·2026-08-13 ·Riya Deepak Shet, Chenxi Liang, Le Zhang
publishedbenchmarkcode/data similarity 0.65
Abstract · 12 pages, 4 figures, 2 tables. Conditionally accepted at MICCAI 2026 BraTS-GoAT challenge workshop. Code: https://github.com/riyashet-hds/br…

Deep networks segment brain tumours accurately in-distribution, but can fail silently when the input differs from their training data. That risk is central to clinical deployment and is the premise of the BraTS-GoAT generalizability task. We ask not only how well a model segments, but whether its uncertainty knows when it is wrong. On BraTS-GoAT (Task 3) we train a 5-fold cross-validated nnU-Net baseline (one held-out prediction per case) and a 3-seed deep ensemble. Both are evaluated for calibration and error detection on a per-region relevant mask, aggregated per case. In-distribution the 3-seed ensemble improves modestly over the already strong single model on the same held-out split, with the clearest gain in calibration. The separation appears under shift. In a controlled robustness study using graded synthetic corruptions as a proxy for acquisition shift, the single model's confidence stays flat while its accuracy and calibration degrade. Inter-member disagreement instead rises steeply, about a quarter to a third above the clean condition, several times the single model's response. On the official validation leaderboard the 5-fold ensemble of those folds attains whole-tumour Dice 0.87. The generalization gap is concentrated on the harder regions, with a characteristic failure of missing small, satellite lesions on unseen cohorts. In the synthetic study, disagreement among the 3-seed members is a more sensitive case-level indicator of acquisition shift than single-model confidence. Its per-voxel error localisation weakens as severity grows. The contribution is a rigorous, honest reliability comparison rather than a claim that any one uncertainty method dominates.

0.44