CS Paper Radar

SCOUT: Risk-Guided Foundation-Model Escalation for Robust Tissue Detection in Whole-Slide Images

Cristian Tommasino, Antonio M. Rinaldi

cs.CV ·submitted 2026-11-18 13:00 UTC · v1
benchmarkcode/data

Abstract

Reliable tissue detection is essential for whole-slide image analysis, yet high average segmentation accuracy can conceal failures involving pale tissue, small fragments, and heterogeneous staining. Pathology foundation models offer transferable representations, but exhaustive inference is computationally demanding and may introduce false-positive tissue predictions. We propose SCOUT (Selective Correction of Uncertain Tissue), a risk-guided cascade that selectively refines an initial thumbnail-based tissue mask. A lightweight audit network estimates the spatial distribution of segmentation errors and prioritizes candidate regions for processing by a frozen pathology foundation model. An asymmetric consensus rule integrates the resulting predictions with the initial mask to recover missed tissue while limiting false positives. A calibrated slide-level review score additionally controls the marginal rate of unflagged case-group failures under the calibration assumptions. Evaluation on a public multi-source, multi-stain benchmark shows that SCOUT reduces the proportion of case groups requiring mask correction from 38.1% for the best released detector to 18.6%, with particularly pronounced improvements in immunohistochemistry. Source-held-out experiments demonstrate better generalization than a segmentation network trained on the same annotations, while selective inference achieves an observed failure rate no higher than processing all candidate regions. Downstream, lymph-node classification with SCOUT masks is non-inferior to that obtained with two of the three released detectors evaluated. A variant built on an openly licensed foundation model is publicly released as an installable Python package with trained weights. These results support risk-guided foundation-model inference as an effective approach to tissue detection across heterogeneous histopathology data.

Closest papers

Nearest neighbours by meaning across the whole index.

MUFASA: An Information Utility-Aware Preprocessing Framework for Reliable Model Reasoning in Computational Pathology

cs.CE ·2026-08-31 ·Rathinaraja Jeyaraj, Barathi Subramanian, Songmi Noh, Mitchell N. Peterson, Terry Guo +5 more
similarity 0.72
Abstract · 28 pages, 10 figures, 7 tables

Reliable computational pathology depends on preprocessing methods that identify informative tissue regions while excluding artifacts and low-utility regions from whole-slide images (WSI). However, existing preprocessing pipelines often retain such regions or discard diagnostically relevant tissue, thereby limiting downstream model performance, reliability, and robustness across heterogeneous cohorts. Here, we systematically evaluate how these regions affect downstream AI model performance across multiple clinically relevant applications and introduce MUFASA, a generalizable, information utility-aware preprocessing framework for H&E-stained WSI that excludes artifacts and low-utility regions while preserving biologically meaningful tissue. MUFASA integrates slide-level artifact masking, stain-aware tile filtering, reconstruction-based utility stratification of tiles, and targeted recovery of tissue tiles that are over-filtered by earlier phases. Across tumor diagnosis, tumor subtyping, biomarker status prediction, and survival prognostication tasks in diverse cancer cohorts, MUFASA consistently improves downstream model performance relative to widely used preprocessing baselines. These gains are accompanied by reduced artifact-associated attribution in model heatmaps, indicating improved alignment between retained tissue and model attention. Our findings establish WSI preprocessing as a critical determinant of downstream model performance and validity, revealing that even accurate predictions can conceal important failure modes stemming from anatomically implausible reasoning driven by retained artifact-containing and low information-utility tiles.

0.21

Reliable Benchmarking of Artifact Detection in Computational Pathology: A Reproducibility and Uncertainty Analysis

cs.CV cs.AI ·2026-08-31 ·Konstantinos Moutselos, Ilias Maglogiannis
similarity 0.70
Abstract · 5 figures

Background and Objective: Quality control is a prerequisite for whole-slide image analysis, yet the benchmarks on which quality-control methods are compared share four properties that make their reported differences hard to interpret: few independent slides, annotation concentrated in a minority of them, pooled ratio metrics with no closed-form standard error, and a single inherited train/test partition. We propose a reliability protocol for such benchmarks. Methods: The protocol quantifies four sources of variability - test-set sampling, training stochasticity, partition composition, and undocumented preprocessing - a claim is reportable only if it survives all four; three of the four cost minutes of compute. We apply it to an independent reconstruction of a published diffusion-based artifact detector, evaluated on the original 24-slide partition and against a supervised baseline. Results: The method's central mechanism reproduces: the auxiliary contrastive term improves pooled F1 from 0.673 to 0.688 and replicates under a second seed (+0.0156, p = 0.031; +0.0190, p = 0.005), although it acts on pen marking rather than the artifact types cited to motivate it. Its comparative claims do not: differences between design variants, and against the supervised baseline, fall inside the uncertainty of the evaluation. Four of 24 slides carry 70% of scored annotated pixels, giving an effective sample size of 6.2, and the inherited partition sits at the 7th percentile. An unreported tissue-restriction step excludes 41.4% of out-of-focus annotation against 2.6% of air bubble; such a gate is confounded with blur by construction. Conclusions: Small-cohort benchmarks support far weaker conclusions than current reporting implies. The four checks are cheap enough to accompany any evaluation on such a resource and separate reproducible effects from differences the evaluation cannot resolve.

0.55

Region-aware error triage for medical image segmentation with groupwise conformal risk control

cs.CV ·2026-11-06 ·Nishi Kanta Paul, Md Shihabul Islam Shovo, Hoileong Lee
similarity 0.68
Abstract · 22 pages, 7 figures, 12 tables. Submitted to Biomedical Signal Processing and Control (BSPC)

Segmentation masks are increasingly reviewed rather than redrawn, which requires knowing where a mask is likely wrong. Learned error maps rank pixels by risk, but the number of pixels to warn is chosen ad hoc, and calibrating one warning threshold over all error pixels may leave errors far from the predicted contour under-flagged. We propose RACE-Triage, a post-hoc error triage framework that leaves the segmentation mask unchanged. A risk network is trained on out-of-fold predictions from backbone-independent inputs. The predicted contour partitions each image into a boundary band and a non-boundary region, and conformal risk control is applied separately in each region to bound the expected fraction of missed errors among cases with errors there. On ISIC 2018 dermoscopy and BUSI breast ultrasound (where patient identifiers are unavailable, so independence across images is assumed), pooled control met its overall target but missed on average 31.8% and 36.4% of non-boundary errors. Regional control reduced these fractions to 19.3% and 20.9% and raised the recall of size-filtered false-negative components from 0.722 to 0.818 and from 0.611 to 0.763. The mean warned area grew by 1.6 and 4.9 percentage points, and its 95th percentile reached 23.5% and 38.5%. The effect held across three seeds and a second backbone, and area-matched heuristics did not reproduce it. On the external PH$^2$ set, frozen thresholds exceeded both targets, whereas recalibration with 100 local images brought the mean over repeated splits below them. Regional calibration improves non-boundary error coverage at a measured increase in warned area.

0.30

A Decision-Aware Evaluation Protocol for Uncertainty in Medical Image Segmentation

cs.CV ·2026-10-15 ·Saket Maganti, Shreyank N Gowda
similarity 0.67
Abstract

Medical segmentation uncertainty is often evaluated with calibration error or pixel-level error-detection scores, but these metrics do not show whether uncertainty improves downstream review decisions. We propose a decision-aware evaluation protocol that separates uncertainty estimation from deferral policy and evaluates their combination under fixed review budgets: which pixels, regions, or images should be accepted, and which should be reviewed. The protocol reports fixed-budget error reduction, risk-coverage behaviour, region-level review proxies, structural failure modes, probability-derived baselines, and sensitivity to review assumptions. We instantiate it across retinal vessel, skin lesion, and polyp segmentation with multiple backbones and uncertainty estimators. Under matched inference budgets and canonical multi-layer MC Dropout, test-time augmentation (TTA) gives a stronger error-detection signal across matched MC--TTA comparisons, including architecture and dropout-placement checks. However, estimator rankings are not universal. For example, probability-derived scores remain competitive, deep ensembles can outperform TTA, learned deferral helps mainly when the base estimator is weak, and rankings can change with review unit, uncertainty target, correction assumptions, and cost model. Structural and second-observer analyses further show that boundary and thin-structure failures are partly tied to annotation ambiguity. These findings support evaluating uncertainty as an estimator-policy-review configuration, not as a standalone score map. Code: https://anonymous.4open.science/r/Uncertainity-in-Medical-Image-Segmentation/README.md

0.34

HERO: Histology Encoder for Robust Representation in Oncology

cs.CV ·2026-09-28 ·Zhi Li, Eghbal Amidi, Yating Cheng, Tyson Dawson, Gorkem Can Ates +9 more
benchmarkcode/data similarity 0.67
Abstract · 22 pages, 4 figures, 13 tables; author information updated; scientific content unchanged

Foundation models trained on large pathology image corpora now provide strong, transferable representations for computational pathology. Over the past few years a series of such models has been released, each trained on more slides than the last; on standard classification and segmentation benchmarks, the leading models are now separated by small margins. In clinical use, however, the foundation model is applied to images from hospitals, scanners, and staining protocols outside its training data. Encoders generally embed these acquisition factors alongside biological information, which may introduce downstream errors and hinder safe clinical adoption. A pathology foundation model should therefore be robust to acquisition shift without giving up representation quality, yet robustness is seldom the axis along which models are compared. In this report, we introduce HERO (Histology Encoder for Robust Representation in Oncology), a ViT-G/14 pathology foundation model trained with the DINO and iBOT objectives and refined with high-resolution Gram anchoring on a morphology-balanced corpus of 500 million tiles from approximately 575,000 clinical whole-slide images. Across the evaluated public benchmarks, HERO shows the strongest robustness to center, scanner, and stain variation among the compared state-of-the-art foundation models, performs comparably on tile-level classification, segmentation, and gene-expression prediction, ranks first on average across 39 evaluated slide-level clinical tasks, and, under an equal-weighted framework-level analysis, has the best average rank across the six benchmark frameworks.

0.22

Whole-Slide Image Analysis under Realistic Few-Shot Annotation Protocols

cs.CV cs.AI ·2026-08-31 ·Tiffanie Godelaine, Maxime Zanella, Karim El Khoury, Benoit Macq, Christophe De Vleeschouwer
similarity 0.67
Abstract · Preprint under review

Automating the analysis of whole-slide images has high clinical value, since characterizing cancers requires examining them in detail. Such analysis increasingly relies on vision-language models that provide patch-level zero-shot predictions. However, these predictions remain noisy and must be refined with a few annotations. A promising paradigm for this refinement is few-shot transduction. Rather than treating each patch independently, these methods leverage the relations between patches, together with a few annotations, to refine all predictions jointly. However, current transductive methods are evaluated under conditions that overlook key properties of whole-slide images: (i) datasets consist of independent patches extracted from multiple slides, ignoring the complex tissue organization; (ii) datasets are mostly balanced, whereas a single whole-slide image exhibits severe class imbalance, with several classes absent; and (iii) annotations are sampled at random, without reflecting how a pathologist annotates a limited number of regions. To align the transduction paradigm to realistic whole-slide settings, we introduce the following contributions. First, we propose SlideCRF, which adapts conditional random fields for whole-slide images by combining spatial and biological cues while accounting for classes that may be absent from a given slide. Second, we provide a set of realistic annotation protocols, based on spatially localized clicks and scribbles, modeling different pathologist interactions, such as the iterative correction of model errors. Across four datasets, we show that SlideCRF outperforms current transductive methods in macro F1, improving over the zero-shot predictions by +24.2% and +37.5% with one and 16 clicks per present class, respectively.

0.49

One-Slide Calibration of Pathology Foundation Models

cs.CV cs.AI ·2026-10-06 ·Ming Ren Hou, Tianyi Huang
published similarity 0.66
Abstract · Accepted at the NeurIPS 2026 Workshop AI at Scale for Clinical Impact (ASCI): Cancer Pathology Foundation Models

Scanner variation changes how pathology foundation models represent the same tissue. We introduce SlideRuler, which uses other regions within a slide as internal controls to predict a query region's scanner-induced shift. A transfer map learned from paired rescans enables calibration from a single scan at inference while keeping the foundation model fixed. Across two encoders and five SCORPION scanners, learned transfer reduces mean target-to-source embedding distance by 16.3-38.5% relative to raw embeddings. Replacing controls with unrelated same-scanner regions reveals a positive same-slide contribution in all four evaluation settings, including scanner holdout. A source-anchored variant reduces source-feature displacement by 47.7-83.6% relative to learned transfer while retaining most of its alignment gain. By drawing calibration information from the slide itself, SlideRuler offers a path toward more consistent use of frozen pathology models across imaging systems.

0.22

Reliability analysis for BraTS-GoAT segmentation: a controlled robustness study of deep-ensemble uncertainty

cs.CV ·2026-08-13 ·Riya Deepak Shet, Chenxi Liang, Le Zhang
publishedbenchmarkcode/data similarity 0.65
Abstract · 12 pages, 4 figures, 2 tables. Conditionally accepted at MICCAI 2026 BraTS-GoAT challenge workshop. Code: https://github.com/riyashet-hds/br…

Deep networks segment brain tumours accurately in-distribution, but can fail silently when the input differs from their training data. That risk is central to clinical deployment and is the premise of the BraTS-GoAT generalizability task. We ask not only how well a model segments, but whether its uncertainty knows when it is wrong. On BraTS-GoAT (Task 3) we train a 5-fold cross-validated nnU-Net baseline (one held-out prediction per case) and a 3-seed deep ensemble. Both are evaluated for calibration and error detection on a per-region relevant mask, aggregated per case. In-distribution the 3-seed ensemble improves modestly over the already strong single model on the same held-out split, with the clearest gain in calibration. The separation appears under shift. In a controlled robustness study using graded synthetic corruptions as a proxy for acquisition shift, the single model's confidence stays flat while its accuracy and calibration degrade. Inter-member disagreement instead rises steeply, about a quarter to a third above the clean condition, several times the single model's response. On the official validation leaderboard the 5-fold ensemble of those folds attains whole-tumour Dice 0.87. The generalization gap is concentrated on the harder regions, with a characteristic failure of missing small, satellite lesions on unseen cohorts. In the synthetic study, disagreement among the 3-seed members is a more sensitive case-level indicator of acquisition shift than single-model confidence. Its per-voxel error localisation weakens as severity grows. The contribution is a rigorous, honest reliability comparison rather than a claim that any one uncertainty method dominates.

0.44