CS Paper Radar

Region-aware error triage for medical image segmentation with groupwise conformal risk control

Nishi Kanta Paul, Md Shihabul Islam Shovo, Hoileong Lee

cs.CV ·submitted 2026-11-06 04:15 UTC · v1

Abstract

Segmentation masks are increasingly reviewed rather than redrawn, which requires knowing where a mask is likely wrong. Learned error maps rank pixels by risk, but the number of pixels to warn is chosen ad hoc, and calibrating one warning threshold over all error pixels may leave errors far from the predicted contour under-flagged. We propose RACE-Triage, a post-hoc error triage framework that leaves the segmentation mask unchanged. A risk network is trained on out-of-fold predictions from backbone-independent inputs. The predicted contour partitions each image into a boundary band and a non-boundary region, and conformal risk control is applied separately in each region to bound the expected fraction of missed errors among cases with errors there. On ISIC 2018 dermoscopy and BUSI breast ultrasound (where patient identifiers are unavailable, so independence across images is assumed), pooled control met its overall target but missed on average 31.8% and 36.4% of non-boundary errors. Regional control reduced these fractions to 19.3% and 20.9% and raised the recall of size-filtered false-negative components from 0.722 to 0.818 and from 0.611 to 0.763. The mean warned area grew by 1.6 and 4.9 percentage points, and its 95th percentile reached 23.5% and 38.5%. The effect held across three seeds and a second backbone, and area-matched heuristics did not reproduce it. On the external PH$^2$ set, frozen thresholds exceeded both targets, whereas recalibration with 100 local images brought the mean over repeated splits below them. Regional calibration improves non-boundary error coverage at a measured increase in warned area.

Comment
22 pages, 7 figures, 12 tables. Submitted to Biomedical Signal Processing and Control (BSPC)

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Accuracy: Uncertainty-Guided Boundary Refinement for Reliable Biomedical Image Segmentation

cs.CV cs.LG ·2026-09-11 ·Anima Kujur
similarity 0.68
Abstract

Accurate biomedical image segmentation requires not only high global overlap but also reliable delineation of clinically meaningful boundaries. In blood-smear microscopy, cytoplasm and nucleus contours provide the structural basis for downstream morphology analysis; however, deep segmentation models may remain uncertain or overconfident near ambiguous boundary regions even when achieving strong Dice scores. This work proposes a Reliability-Aware Boundary Refinement Network (RABR-Net), a two-stage framework for trustworthy image segmentation. A strong UNet++ EfficientNet-B4 base segmenter first produces initial class probabilities and logits. Predictive entropy, test-time augmentation variance, margin uncertainty, probability gradients, and soft boundary cues are then combined into a boundary-aware reliability representation. This representation guides a gated residual refiner that selectively corrects uncertain boundary pixels while preserving confident regions of the base prediction. The framework is evaluated using overlap accuracy, class-wise Dice, Boundary Dice, HD95/ASSD, calibration, risk--coverage analysis, robustness under image perturbations, qualitative correction maps, and paired statistical testing. On the held-out test set, the proposed method improves Dice from 0.9602 to 0.9614, Boundary Dice from 0.3448 to 0.3611, and HD95 from 3.0354 to 2.8274 compared with the cached base prediction. Statistical analysis confirms significant improvements in Dice, Boundary Dice, and HD95. Qualitative results show that the learned gate concentrates around uncertain cytoplasm and nucleus boundaries, and correction maps confirm localized boundary refinement. Although calibration does not automatically improve after refinement, the proposed framework provides an interpretable and reliability-focused strategy for boundary-sensitive biomedical image segmentation.

0.22

A Decision-Aware Evaluation Protocol for Uncertainty in Medical Image Segmentation

cs.CV ·2026-10-15 ·Saket Maganti, Shreyank N Gowda
similarity 0.68
Abstract

Medical segmentation uncertainty is often evaluated with calibration error or pixel-level error-detection scores, but these metrics do not show whether uncertainty improves downstream review decisions. We propose a decision-aware evaluation protocol that separates uncertainty estimation from deferral policy and evaluates their combination under fixed review budgets: which pixels, regions, or images should be accepted, and which should be reviewed. The protocol reports fixed-budget error reduction, risk-coverage behaviour, region-level review proxies, structural failure modes, probability-derived baselines, and sensitivity to review assumptions. We instantiate it across retinal vessel, skin lesion, and polyp segmentation with multiple backbones and uncertainty estimators. Under matched inference budgets and canonical multi-layer MC Dropout, test-time augmentation (TTA) gives a stronger error-detection signal across matched MC--TTA comparisons, including architecture and dropout-placement checks. However, estimator rankings are not universal. For example, probability-derived scores remain competitive, deep ensembles can outperform TTA, learned deferral helps mainly when the base estimator is weak, and rankings can change with review unit, uncertainty target, correction assumptions, and cost model. Structural and second-observer analyses further show that boundary and thin-structure failures are partly tied to annotation ambiguity. These findings support evaluating uncertainty as an estimator-policy-review configuration, not as a standalone score map. Code: https://anonymous.4open.science/r/Uncertainity-in-Medical-Image-Segmentation/README.md

0.34

Beyond Uncertainty: Generalizable Failure Monitoring for Surgical Segmentation under Acquisition Degradation

cs.CV ·2026-08-17 ·Hieu D. Pham, Dang P. M. Cao, Thanh Trung Huynh
published similarity 0.67
Abstract · Accepted at MICCAI'2026 @UNSURE Workshop

Surgical segmentation networks can fail silently under acquisition degradation: predicted masks may be wrong even when model confidence remains high. Existing deployment-time monitors rely primarily on uncertainty estimates and can therefore miss confident failures. We present TCSR-Monitor (Temporal Conformal Surgical Risk Monitor), a post-hoc failure-monitoring framework that combines confidence with observable shape, temporal-consistency, and image-quality cues. TCSR-Monitor wraps a frozen segmentation model, requires no model internals, and operates without ground truth at deployment. We also introduce a validation protocol to assess whether alarms remain credible under distribution shift. On EndoVis 2017, leave-one-corruption-out evaluation shows that TCSR-Monitor generalizes to unseen acquisition degradations and substantially outperforms confidence-based baselines. A circularity control confirms that it predicts segmentation failure rather than simply detecting corrupted images. Mondrian conformal calibration balances miss-rates across degradation severities, but a single global threshold still produces false alarms on up to 40% of correctly segmented frames at moderate corruption. Zero-shot transfer to SAM2 demonstrates feature portability, although entropy outperforms the transferred monitor at both evaluated thresholds. Overall, reliable monitoring under acquisition degradation benefits from complementary observable signals beyond confidence alone, but substantial false-alarm and transfer limitations remain.

0.34

ReCIRC: Rectified Conformal Risk Control

cs.LG stat.ML ·2026-09-29 ·Bruno Marcondes e Resende, Helton Graziadei, Thiago Rodrigo Ramos, Rafael Izbicki
similarity 0.66
Abstract · 69 pages, 11 figures

Many applications of black-box predictive models require controlling task-relevant error rates, such as missed lesion pixels in segmentation or missed labels in multilabel classification. Conformal risk control (CRC; Angelopoulos et al., arXiv:2208.02814) gives distribution-free guarantees for such losses, but it calibrates a single threshold shared by all inputs. Because conditional risk varies with the input, this marginal guarantee often overprotects easy cases and underprotects hard ones. We propose ReCIRC (Rectified Conformal Risk Control), which inverts each input's estimated local risk curve to reparameterize the calibrated threshold as a risk budget $a$ representing a common target conditional risk, and then applies CRC unchanged to the resulting family. ReCIRC retains CRC's finite-sample marginal guarantee regardless of the accuracy of the estimated curves, while accurate curves yield approximate conditional risk control and, under additional conditions, asymptotically exact conditional risk control; they also support a risk-calibration diagnostic. Across three synthetic and five real-data settings spanning segmentation, multilabel and multiclass classification, and regression, ReCIRC attained the lowest average worst-group risk and mean positive group excess in every setting, while maintaining marginal risk close to the target, whereas changes in prediction size were application-dependent.

0.54

Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

cs.CV ·2026-09-16 ·Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar +2 more
code/data similarity 0.66
Abstract · The PDF includes the Supplementary Information. Code is available at https://github.com/AlfredQin/sonobase

Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code at https://github.com/AlfredQin/sonobase.

0.36

Evolving Error States: Failure-Aware Progressive Repair for Ultrasound Lesion Segmentation

cs.CV ·2026-09-16 ·Ziliang Wang, XuJiang Tang, Lu Yuting, Weixin Xu, Yongqiang Zhao +2 more
similarity 0.65
Abstract

Reliability under sparse and heterogeneous failures remains a fundamental challenge for medical image segmentation. High average accuracy can conceal a small set of structurally distinct and clinically consequential errors. Existing post-hoc correction methods alleviate this problem, but typically estimate false-positive and false-negative corrections from the same fixed prediction. This ignores the dynamic evolution of error states and limits the correction of complex cases. Inspired by iterative error feedback in structured prediction, we propose Failure-Aware Progressive Repair (FAPR). FAPR represents the current segmentation mask as a dynamic failure state and models each repair operation as a state-transition operator. Each accepted correction forms a new prediction state for subsequent error diagnosis and repair, enabling later operations to adapt to preceding changes. Conditional routing selectively activates necessary state transitions, while failure replay exposes the model to rare error states. By keeping the base segmentor frozen, FAPR preserves its established segmentation capability while improving difficult cases. Across three public ultrasound lesion segmentation benchmarks, FAPR improves mean DSC by 1.52%. On the very-hard subsets of BUSI and TN3K, the average gain reaches 13.77%.

0.30

Thyroid Nodule Segmentation in Ultrasound Images with Conformal Uncertainty Estimation

cs.CV stat.AP ·2026-10-09 ·Francesco Teodori, Pierpaolo Brutti, Umberto Ferraro Petrillo
publishedbenchmark similarity 0.65
Abstract · Presented at the CIBB 2026 conference

Thyroid nodules affect a large proportion of the general population. Although most are benign, a non-negligible fraction is malignant. Ultrasound imaging is the primary diagnostic modality, and accurate nodule segmentation is a prerequisite for CAD systems to classify malignancy and assess metastatic risk.\\ In this work, we propose a thyroid nodule segmentation framework that integrates a DeepLabV3+, channel-attention modules and post-hoc conformal prediction, providing both accurate mask and pixel-level uncertainty estimates. We address thyroid ultrasound nodule segmentation as the first stage of a pipeline that also includes malignancy classification and metastatic risk prediction. We adopt DeepLabV3+, whose Atrous Spatial Pyramid Pooling (ASPP) captures multi-scale context, with an EfficientNet-B5 backbone for its accuracy-efficiency trade-off. Additionally, we test three channel-attention modules: Squeeze-and-Excitation, CBAM and Grouped Channel Attention (GCA), paired with two loss formulations (Dice-BCE and Boundary).\\ Since binary masks do not indicate prediction confidence, we wrap the trained model with a split conformal prediction layer that produces pixel-level uncertainty maps with statistical coverage guarantees.\\ We evaluate all configurations on the TN3K public benchmark using a fixed split and directly compare them with state-of-the-art methods. The plain backbone already improves upon previously reported results, with CBAM + Dice-BCE emerging as the best overall configuration.

0.17

Uncertainty of Vision Medical Foundation Models

cs.LG ·2026-08-31 ·Haoxu Huang, Narges Razavian
similarity 0.64
Abstract

Accurate uncertainty estimation is essential for machine learning systems de- ployed in high-stakes domains such as medicine. Traditional approaches primarily rely on probability outputs from trained models (point predictions), which provide no formal guarantees on prediction coverage and often require additional calibra- tion techniques to improve reliability. In contrast, conformal prediction (region prediction) offers a principled alternative by generating prediction sets with finite- sample validity guarantees, ensuring that the ground truth is contained within the set at a specified confidence level. In this study, we explore the impact of pre-training approach, dataset scale and domain on both point and region-level uncertainty quantification, by studying domain-specific vision medical foundation models vs. general domain vision foundation models. We conduct a comprehensive evaluation across foundation models trained on retinal, histopathological, and Chest X-Rays data, applying various calibration techniques. Our results demonstrate that (1) pre-training on higher-quality domain-specific datasets along with self-supervised learning leads to better-calibrated point predictions than general domain pre-training, (2) stan- dard re-calibration methods alone cannot fully mitigate uncertainty discrepancies across models trained on different data sources, (3) domain-specific foundation model can lead to more efficient conformal prediction. These findings highlight the importance of careful model selection and the inte- gration of both point and region prediction to enhance the reliability and trust- worthiness of medical AI systems. Our work underscores the need for a holistic approach to uncertainty quantification in recent development of medical vision foundation model, ensuring robust and interpretable AI-driven decision-making.

0.06