CS Paper Radar

Beyond Accuracy: Uncertainty-Guided Boundary Refinement for Reliable Biomedical Image Segmentation

Anima Kujur

cs.CV cs.LG ·submitted 2026-09-11 14:21 UTC · v1

Abstract

Accurate biomedical image segmentation requires not only high global overlap but also reliable delineation of clinically meaningful boundaries. In blood-smear microscopy, cytoplasm and nucleus contours provide the structural basis for downstream morphology analysis; however, deep segmentation models may remain uncertain or overconfident near ambiguous boundary regions even when achieving strong Dice scores. This work proposes a Reliability-Aware Boundary Refinement Network (RABR-Net), a two-stage framework for trustworthy image segmentation. A strong UNet++ EfficientNet-B4 base segmenter first produces initial class probabilities and logits. Predictive entropy, test-time augmentation variance, margin uncertainty, probability gradients, and soft boundary cues are then combined into a boundary-aware reliability representation. This representation guides a gated residual refiner that selectively corrects uncertain boundary pixels while preserving confident regions of the base prediction. The framework is evaluated using overlap accuracy, class-wise Dice, Boundary Dice, HD95/ASSD, calibration, risk--coverage analysis, robustness under image perturbations, qualitative correction maps, and paired statistical testing. On the held-out test set, the proposed method improves Dice from 0.9602 to 0.9614, Boundary Dice from 0.3448 to 0.3611, and HD95 from 3.0354 to 2.8274 compared with the cached base prediction. Statistical analysis confirms significant improvements in Dice, Boundary Dice, and HD95. Qualitative results show that the learned gate concentrates around uncertain cytoplasm and nucleus boundaries, and correction maps confirm localized boundary refinement. Although calibration does not automatically improve after refinement, the proposed framework provides an interpretable and reliability-focused strategy for boundary-sensitive biomedical image segmentation.

Closest papers

Nearest neighbours by meaning across the whole index.

EA-LiteUNet: An Edge-Adaptive and Resource-Efficient U-Net for Boundary-Sensitive Dermoscopic Image Segmentation

cs.CV cs.AI ·2026-08-16 ·Wang Jiangtao, Nur Intan Raihana Ruhaiyem, Fu Panpan, Yang Yu, Huang Yan
similarity 0.69
Abstract · 29 Pages,13 figures, 8 tables

Accurate boundary delineation remains a persistent challenge in dermoscopic image segmentation because of blurred lesion margins, heterogeneous textures, and complex background artifacts. From a signal-processing perspective, lesion boundaries represent high-frequency components that are highly susceptible to aliasing, noise amplification, and information loss. Consequently, repeated downsampling and feature transformations in conventional convolutional architectures often lead to severely degraded boundary representations. To address these limitations, we propose EA-LiteUNet, an edge-adaptive and computationally efficient U-Net variant specifically designed for boundary-sensitive medical image segmentation. The architecture integrates three core mechanisms: (1) boundary-aware representation learning to suppress aliasing and preserve high-frequency structural details; (2) attention-guided feature modulation to selectively enhance boundary-relevant responses across multi-scale features; and (3) a resource-adaptive inference strategy to dynamically balance segmentation accuracy and computational efficiency. Extensive evaluations across three public dermoscopic datasets demonstrate that EA-LiteUNet consistently achieves superior boundary precision. Specifically, on the ISIC 2018 dataset, the method significantly reduces the 95% Hausdorff Distance (HD95) to 12.89 pixels while maintaining a robust Dice score of 92.08%. Notably, this strong performance is achieved with an ultralightweight configuration of merely 0.29M parameters and 1.17 GFLOPs. Ablation studies further validate the complementary effects of these components, confirming their contribution to enhanced boundary fidelity and stable optimization.

0.10

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation

cs.CV ·2026-10-01 ·Samuel Hart, Ahmad Yahya, Ahmed Karam Eldaly
theory similarity 0.69
Abstract · 12 pages

While state-of-the-art automated models for medical image segmentation achieve high mean performance, they frequently suffer from localized, catastrophic failures that preclude safe clinical deployment, particularly in neuro-oncology. Interactive segmentation frameworks mitigate this by incorporating human oversight, but traditionally impose prohibitive cognitive and temporal workloads by requiring clinicians to manually search for errors. In this project, we present an efficient, Hybrid Structural-Aleatoric Human-in-the-Loop framework for glioma segmentation that bridges the gap between automated baseline performance and surgical-grade precision, achieving sub-2.0 mm HD95 on curated benchmarks while providing safety-net routing for structural failures across real-world clinical data. By extracting voxel-wise Test-Time Augmentation (TTA) uncertainty and applying hierarchical topological filtering, our method proactively isolates high-risk structural anomalies. We comprehensively evaluated our approach on a challenging out-of-distribution clinical stress-test cohort (N = 362). Operating under a simulated Human Oracle, the framework improved the Whole Tumor (WT) Dice score from 0.891 to 0.914 and reduced the 95th percentile Hausdorff Distance (HD95) from 5.82 mm to 4.76 mm. Critically for surgical safety, the system rescued severe boundary failures in the Tumor Core, reducing mean HD95 from 17.96 mm to 14.83 mm (improving absolute TC Dice to 0.356). These spatial rescues were achieved while demanding a median interactive workload of just 11.3% of the target volume. Acknowledging this as a simulated upper bound lacking real-world cognitive friction, the framework nevertheless demonstrates a highly Pareto-efficient pathway for safely deploying clinical AI.

0.15

Region-aware error triage for medical image segmentation with groupwise conformal risk control

cs.CV ·2026-11-06 ·Nishi Kanta Paul, Md Shihabul Islam Shovo, Hoileong Lee
similarity 0.68
Abstract · 22 pages, 7 figures, 12 tables. Submitted to Biomedical Signal Processing and Control (BSPC)

Segmentation masks are increasingly reviewed rather than redrawn, which requires knowing where a mask is likely wrong. Learned error maps rank pixels by risk, but the number of pixels to warn is chosen ad hoc, and calibrating one warning threshold over all error pixels may leave errors far from the predicted contour under-flagged. We propose RACE-Triage, a post-hoc error triage framework that leaves the segmentation mask unchanged. A risk network is trained on out-of-fold predictions from backbone-independent inputs. The predicted contour partitions each image into a boundary band and a non-boundary region, and conformal risk control is applied separately in each region to bound the expected fraction of missed errors among cases with errors there. On ISIC 2018 dermoscopy and BUSI breast ultrasound (where patient identifiers are unavailable, so independence across images is assumed), pooled control met its overall target but missed on average 31.8% and 36.4% of non-boundary errors. Regional control reduced these fractions to 19.3% and 20.9% and raised the recall of size-filtered false-negative components from 0.722 to 0.818 and from 0.611 to 0.763. The mean warned area grew by 1.6 and 4.9 percentage points, and its 95th percentile reached 23.5% and 38.5%. The effect held across three seeds and a second backbone, and area-matched heuristics did not reproduce it. On the external PH$^2$ set, frozen thresholds exceeded both targets, whereas recalibration with 100 local images brought the mean over repeated splits below them. Regional calibration improves non-boundary error coverage at a measured increase in warned area.

0.30

Beyond Boundary Noise: Aggregated Aleatoric Uncertainty Fails to Capture Presence Ambiguity in 3D Lung Nodule Segmentation

cs.CV cs.LG ·2026-08-14 ·Simon Baur, Arne Schernich, Ekin Böke, Wojciech Samek, Jackie Ma
similarity 0.68
Abstract

Uncertainty estimation is critical for the safe clinical deployment of deep learning in medical image segmentation, with aleatoric uncertainty theoretically designed to capture irreducible data ambiguity. However, whether entropy-based measures reflect clinically meaningful ambiguity, i.e. case-level disagreement about whether a pathology is present at all, remains poorly understood. Contrary to most prior work, which focused on pixel-wise boundary disagreement, we systematically evaluate how well aleatoric uncertainty captures presence ambiguity. Our evaluation spans 3D lung nodule segmentation across four architectures with Monte Carlo dropout and deep ensembles, on LIDC-IDRI and an external validation cohort (LNDb). We find that entropy-based uncertainty maps align with boundary noise and minor drawing variation but carry insufficient discriminative signal for presence ambiguity. In contrast, a lightweight supervised ambiguity head trained on frozen segmentation features substantially outperforms all entropy-aggregation-based baselines across architectures, metrics, and both cohorts, and matches or exceeds methods that explicitly model ambiguity under disagreement supervision (Probabilistic U-Net, Annotator-Confusion 3D-UNet). A qualitative feature-space analysis shows that presence ambiguity is already encoded in the frozen encoder features of pixel-wise-trained networks, only to be discarded by the segmentation output and its entropy aggregation. Our findings expose a fundamental mismatch between the theoretical promise of aleatoric uncertainty and its practical behavior, and suggest that practitioners should not rely on entropy-based uncertainty as a proxy for clinical ambiguity in safety-critical applications.

0.34

Uni-Light: An Ultra-Lightweight Framework via Uncertainty-Aware Knowledge Distillation for Brain Tumour Segmentation

cs.CV ·2026-09-06 ·Libing Kuang, Soren Salehi, Ziling Wu, Ahmad P. Tafti, Armaghan Moemeni
similarity 0.68
Abstract

Accurate 3D brain tumour segmentation from multi-modal Magnetic Resonance Imaging (MRI) is essential for clinical diagnosis and treatment planning. Existing brain tumour segmentation methods often suffer from heavy computational demands, while current lightweight architectures frequently lack the capacity to maintain segmentation fidelity in complex tumour regions. To address these issues, we propose a novel ultra-lightweight framework (Uni-Light) that achieves high-fidelity segmentation with substantially reduced computational overhead. It combines multi-scale convolutions with an uncertainty-aware knowledge distillation scheme that directs the student model toward hard-to-classify regions, complemented by a Signed Distance Field boundary loss for geometric constraints. Experimental results on BraTS2023-GLI and MSD-BTS datasets demonstrate that Uni-Light reduces parameters by 97.56%, floating-point operations (FLOPs) by 73.03%, and inference memory footprint by 81.58%, while surpassing the state-of-the-art model by an average of 1.47% in Dice score, offering a highly competitive trade-off between segmentation accuracy and computational efficiency in resource-constrained clinical settings. This work also advances data engineering for medical imaging by demonstrating that teacher model uncertainty can be exploited as a data-driven supervisory signal, re-prioritising the training data distribution without requiring additional annotation.

0.24

Segmentation Confidence for Arbitrary CNNs

cs.CV ·2026-10-27 ·Baris Oguz, Xing Yao, Claudia Tawil, Alison Pouch, Brett Byram +3 more
published similarity 0.67
Abstract · 5 pages, 6 figures, published in ISBI 2026

Convolutional neural networks (CNN) are widely used for medical image segmentation. However, they lack an inherent measure of confidence. Existing methods for estimating prediction uncertainty often require a custom network architecture and/or dedicated training setups and need to be trained from scratch. In addition, the deduction of a single confidence score per input from the uncertainty maps is not always straightforward. In this study, we explore voxel-based uncertainty estimation methods that can be added to existing segmentation pipelines without training from scratch. We also propose a novel method to estimate a single confidence score from the uncertainty maps. Our evaluations on different ROIs and modalities suggest that our confidence score can predict segmentation performance in unseen data.

0.25

Peripheral prototypical contrastive loss for supervised medical image segmentation

cs.CV physics.med-ph ·2026-11-01 ·Takuro Shimaya, Ryosaku Shino, Masahiro Saiko
published similarity 0.67
Abstract · 5pages, accepted to ISBI2026

Robust segmentation of biomedical images remains challenging primarily due to ill-defined object boundaries. Although several loss functions have recently been proposed to enhance object boundary recognition, concerns remain about the susceptibility to unstable annotations resulting from boundary ambiguities. Here, we introduce the Peripheral Prototypical Contrastive (PPC) loss, which leverages prototypical contrastive learning to improve boundary recognition and enable stable training even under noisy annotation conditions. The PPC loss utilizes prototype features obtained from local regions near object boundaries, focusing specifically on ambiguous areas that have been challenging for existing approaches. Extensive experiments across multiple datasets demonstrated that the PPC loss consistently improve segmentation performance even under conditions with noisy labels. A newly proposed strategy, which adaptively determines the local region for prototype calculation, enhanced robustness and outperformed existing methods. Our findings indicate the potential of the PPC loss in facilitating scalable and reliable medical image segmentation, including the development of foundation models with imperfect annotations.

0.33

BGD-SF PolySegNet: boundary-guided dynamic selective fusion network for robust polyp segmentation in colonoscopy images

cs.CV ·2026-11-02 ·Nishi Kanta Paul, Shamia Maherin, Morsheda Akter, Moinul Hossain, Md Kishor Morol
benchmark similarity 0.67
Abstract · 26 pages, 9 figures, 8 tables, Submitted to PLOS ONE

Effective polyp segmentation in colonoscopy images is crucial for early detection of colorectal cancer, a leading cause of cancer-related death worldwide. While current deep learning models perform well on traditional Dice benchmarks, border segmentation remains difficult. Most methods use boundary information only as an additional loss signal during training, which prevents the network from explicitly learning border-guided feature selection or mask refinement. This paper introduces BGD-SF PolySegNet, a boundary-guided encoder-decoder architecture that controls three phases of the segmentation pipeline: dynamic multi-scale context aggregation, selective skip-feature fusion, and final mask refinement. The architecture comprises a pretrained EfficientNet-B4 backbone and three proposed modules: Boundary-Guided Dynamic Cascaded Multi-Scale Context Aggregation (BGD-CMSCA), Boundary-Guided Selective Attention Fusion (BG-SAGF), and a Multi-Level Boundary Guidance Head (MBGH). The model is trained on 3,535 annotated images from Kvasir-SEG, BKAI-IGH NeoPolyp-Small, and PolypGen, and evaluated on four held-out benchmark datasets. On the internal test set, BGD-SF achieves a Dice of 0.887, IoU of 0.839, mask-derived Boundary F1 of 0.531, HD95 of 30.32, and ASSD of 18.10, improving Boundary F1, HD95, and ASSD by 15.7%, 27.5%, and 34.6% over the strongest CNN baselines. External validation on CVC-ClinicDB, CVC-ColonDB, ETIS-Larib, and CVC-300 yielded Dice scores of 0.891, 0.776, 0.863, and 0.885, respectively. The model runs at 35 FPS with 22.51M parameters. Wilcoxon signed-rank tests confirm statistically significant mask-derived Boundary F1 improvements over six of seven ablation variants (p < 0.001; small-to-moderate effect sizes, r = 0.215-0.434), demonstrating that integrating boundary guidance as an active architectural component measurably advances polyp boundary delineation.

0.32