CS Paper Radar

BGD-SF PolySegNet: boundary-guided dynamic selective fusion network for robust polyp segmentation in colonoscopy images

Nishi Kanta Paul, Shamia Maherin, Morsheda Akter, Moinul Hossain, Md Kishor Morol

cs.CV ·submitted 2026-11-02 06:26 UTC · v1
benchmark

Abstract

Effective polyp segmentation in colonoscopy images is crucial for early detection of colorectal cancer, a leading cause of cancer-related death worldwide. While current deep learning models perform well on traditional Dice benchmarks, border segmentation remains difficult. Most methods use boundary information only as an additional loss signal during training, which prevents the network from explicitly learning border-guided feature selection or mask refinement. This paper introduces BGD-SF PolySegNet, a boundary-guided encoder-decoder architecture that controls three phases of the segmentation pipeline: dynamic multi-scale context aggregation, selective skip-feature fusion, and final mask refinement. The architecture comprises a pretrained EfficientNet-B4 backbone and three proposed modules: Boundary-Guided Dynamic Cascaded Multi-Scale Context Aggregation (BGD-CMSCA), Boundary-Guided Selective Attention Fusion (BG-SAGF), and a Multi-Level Boundary Guidance Head (MBGH). The model is trained on 3,535 annotated images from Kvasir-SEG, BKAI-IGH NeoPolyp-Small, and PolypGen, and evaluated on four held-out benchmark datasets. On the internal test set, BGD-SF achieves a Dice of 0.887, IoU of 0.839, mask-derived Boundary F1 of 0.531, HD95 of 30.32, and ASSD of 18.10, improving Boundary F1, HD95, and ASSD by 15.7%, 27.5%, and 34.6% over the strongest CNN baselines. External validation on CVC-ClinicDB, CVC-ColonDB, ETIS-Larib, and CVC-300 yielded Dice scores of 0.891, 0.776, 0.863, and 0.885, respectively. The model runs at 35 FPS with 22.51M parameters. Wilcoxon signed-rank tests confirm statistically significant mask-derived Boundary F1 improvements over six of seven ablation variants (p < 0.001; small-to-moderate effect sizes, r = 0.215-0.434), demonstrating that integrating boundary guidance as an active architectural component measurably advances polyp boundary delineation.

Comment
26 pages, 9 figures, 8 tables, Submitted to PLOS ONE

Closest papers

Nearest neighbours by meaning across the whole index.

Polyp-VSSD: A Pre-trained Transformer with Local-Global Joint VSSD Decoding for Polyp Segmentation

cs.CV ·2026-10-23 ·Xiaobo Zhu, Shiwei Wu, Yu An, Yuechen Tao, He Sun +2 more
similarity 0.69
Abstract

Early detection of colorectal polyps is essential for preventing colorectal cancer, making accurate polyp segmentation a key component in computer-aided diagnosis systems. However, existing endoscopic segmentation methods often exhibit limited representational capacity and insufficient integration of global and local contextual information. To address these limitations, we propose Polyp-VSSD, a novel local-global joint decoding framework built upon a pre-trained Transformer backbone for high-precision polyp segmentation. Polyp-VSSD leverages the strong feature expressiveness of large-scale visual pre-training and unifies global semantic modeling with local fine-grained reconstruction to enhance segmentation fidelity. Extensive experiments on multiple public endoscopic datasets demonstrate that our approach significantly outperforms state-of-the-art methods in both Dice and IoU. On the EndoScene dataset, Polyp-VSSD achieves mIoU and mDice scores of 0.903 and 0.946, respectively, highlighting its robustness and strong generalization capability. This work presents an effective and scalable solution for intelligent endoscopic image analysis.

0.25

CSG-Mamba: A Convolutional Scoring Gating Vision State Space Network for Endoscopic Polyp Segmentation

cs.CV ·2026-08-14 ·Yuliang Wang, Jiaqi Wu, Jiaye Song, Shuxia Ren
published similarity 0.69
Abstract · 14 pages, 6 figures, and 5 tables. Accepted by ICONIP 2026

Accurate polyp segmentation is critical for computer-aided colonoscopy, yet endoscopic images often contain low-contrast boundaries, mucosal texture interference, specular highlights, and device-dependent appearance shifts. Vision State Space Models (SSMs) provide efficient long-range modeling with linear complexity, but existing Vision Mamba segmentation models typically convert 2D features into 1D scanning sequences, which may weaken local geometric continuity and over-smooth irregular contours. We propose CSG-Mamba, a convolutional scoring gating Vision State Space network for endoscopic polyp segmentation. Built on a VM-UNet-style asymmetric U-shaped encoder-decoder, CSG-Mamba inserts a Convolutional Scoring Gating (CSG) module at the semantically rich bottleneck. CSG generates a local spatial score map through pointwise and large-kernel depthwise convolutions and recalibrates state-space features by multiplicative gating. Experiments with three random seeds show that CSG-Mamba achieves 0.9220 Dice and 15.87 HD95 on Kvasir-SEG, and 0.7418 Dice and 0.6570 mIoU on CVC-ColonDB, outperforming the baselines on most overlap and recall metrics while maintaining competitive boundary accuracy.

0.28

EA-LiteUNet: An Edge-Adaptive and Resource-Efficient U-Net for Boundary-Sensitive Dermoscopic Image Segmentation

cs.CV cs.AI ·2026-08-16 ·Wang Jiangtao, Nur Intan Raihana Ruhaiyem, Fu Panpan, Yang Yu, Huang Yan
similarity 0.68
Abstract · 29 Pages,13 figures, 8 tables

Accurate boundary delineation remains a persistent challenge in dermoscopic image segmentation because of blurred lesion margins, heterogeneous textures, and complex background artifacts. From a signal-processing perspective, lesion boundaries represent high-frequency components that are highly susceptible to aliasing, noise amplification, and information loss. Consequently, repeated downsampling and feature transformations in conventional convolutional architectures often lead to severely degraded boundary representations. To address these limitations, we propose EA-LiteUNet, an edge-adaptive and computationally efficient U-Net variant specifically designed for boundary-sensitive medical image segmentation. The architecture integrates three core mechanisms: (1) boundary-aware representation learning to suppress aliasing and preserve high-frequency structural details; (2) attention-guided feature modulation to selectively enhance boundary-relevant responses across multi-scale features; and (3) a resource-adaptive inference strategy to dynamically balance segmentation accuracy and computational efficiency. Extensive evaluations across three public dermoscopic datasets demonstrate that EA-LiteUNet consistently achieves superior boundary precision. Specifically, on the ISIC 2018 dataset, the method significantly reduces the 95% Hausdorff Distance (HD95) to 12.89 pixels while maintaining a robust Dice score of 92.08%. Notably, this strong performance is achieved with an ultralightweight configuration of merely 0.29M parameters and 1.17 GFLOPs. Ablation studies further validate the complementary effects of these components, confirming their contribution to enhanced boundary fidelity and stable optimization.

0.10

PolypVision: A Three-Stage Hierarchical Deep Learning Framework for Classification and Segmentation of Colorectal Polyps

cs.CV ·2026-08-11 ·Hamidreza Bolhasani, Hamidreza Rastad, Amir Mohammad Akbari, Mohammad Tashakoripour, Parnian Asadollahi +2 more
similarity 0.68
Abstract

Colorectal cancer (CRC) remains one of the leading causes of cancer-related mortality worldwide, predominantly arising from precancerous polyps. Accurate detection, segmentation, and endoscopic and histological classification of colorectal polyps are crucial for timely clinical intervention. In this study, we present PolypVision, a three-stage hierarchical deep learning framework that sequentially performs: (Stage 1) binary classification of polyps as adenomatous or hyperplastic, with simultaneous Paris and JNet classification, using EfficientNetV2-M with Focal Loss; (Stage 2) polyp segmentation with recommended resection method using a UNet++ decoder with the Stage 1 backbone as encoder, optimized with Dice and BCE losses; and (Stage 3) adenoma subtype classification (tubular, tubulovillous, villous) using EfficientNetV2-M with transfer learning from Stage 2. Evaluated on three public datasets -- PolypGen, Kvasir-SEG, and CVC-ClinicDB -- PolypVision achieves an AUC of approximately 0.99 for frame classification and a detection mAP@50 of 94.4% on Kvasir-SEG, outperforming or matching state-of-the-art methods. Gradient-weighted Class Activation Maps (Grad-CAM) confirm that the model attends to clinically relevant lesion features. The framework is device-independent, operating across diverse endoscopic imaging systems without hardware-specific adaptation. These results demonstrate that a hierarchical, transfer-learning-driven pipeline with task-specific loss functions offers a robust, device-independent, and clinically meaningful approach to automated colorectal polyp analysis. PolypVision is freely available as a web application at https://polypvision.com, a DataBioX initiative, with a free usage tier open to all users.

0.16

Beyond Accuracy: Uncertainty-Guided Boundary Refinement for Reliable Biomedical Image Segmentation

cs.CV cs.LG ·2026-09-11 ·Anima Kujur
similarity 0.67
Abstract

Accurate biomedical image segmentation requires not only high global overlap but also reliable delineation of clinically meaningful boundaries. In blood-smear microscopy, cytoplasm and nucleus contours provide the structural basis for downstream morphology analysis; however, deep segmentation models may remain uncertain or overconfident near ambiguous boundary regions even when achieving strong Dice scores. This work proposes a Reliability-Aware Boundary Refinement Network (RABR-Net), a two-stage framework for trustworthy image segmentation. A strong UNet++ EfficientNet-B4 base segmenter first produces initial class probabilities and logits. Predictive entropy, test-time augmentation variance, margin uncertainty, probability gradients, and soft boundary cues are then combined into a boundary-aware reliability representation. This representation guides a gated residual refiner that selectively corrects uncertain boundary pixels while preserving confident regions of the base prediction. The framework is evaluated using overlap accuracy, class-wise Dice, Boundary Dice, HD95/ASSD, calibration, risk--coverage analysis, robustness under image perturbations, qualitative correction maps, and paired statistical testing. On the held-out test set, the proposed method improves Dice from 0.9602 to 0.9614, Boundary Dice from 0.3448 to 0.3611, and HD95 from 3.0354 to 2.8274 compared with the cached base prediction. Statistical analysis confirms significant improvements in Dice, Boundary Dice, and HD95. Qualitative results show that the learned gate concentrates around uncertain cytoplasm and nucleus boundaries, and correction maps confirm localized boundary refinement. Although calibration does not automatically improve after refinement, the proposed framework provides an interpretable and reliability-focused strategy for boundary-sensitive biomedical image segmentation.

0.22

Lightweight Vision Transformer-Based U-Net for Brain Tumor Segmentation from MRI

cs.CV ·2026-09-24 ·Sheekar Banerjee, Md. Srabon Chowdhury, Md. Mahbub Hasan Akash, Ishtiak Al Mamoon
published similarity 0.67
Abstract · Accepted at The 2026 IEEE International Conference on Biomedical Engineering, Computer and Information Technology for Health (BECITHCON)

Accurate brain tumor segmentation from Magnetic Resonance Imaging is essential for diagnosis, treatment planning, and surgical guidance. Although Convolutional Neural Networks, particularly UNet, have achieved significant success in medical image segmentation, they often struggle to capture the long-range spatial dependencies required to model tumors with irregular shapes and complex boundaries. This paper proposes a lightweight Vision Transformer UNet that combines the hierarchical feature extraction capability of UNet with the global context modeling of Vision Transformers. The proposed architecture incorporates a compact ViT bottleneck within a U-Net encoder-decoder framework, enabling effective learning of both local and global features while maintaining computational efficiency with only 2.6 million trainable parameters. The model was evaluated on the TCGA LGG MRI Segmentation dataset, achieving a mean Intersection over Union of 0.8100 and a Dice score of 0.8446, outperforming the baseline UNet by 3.75% and 3.15%, respectively. Extensive quantitative and qualitative analyses, including confusion matrix evaluation, precision recall curves, per-image performance distribution, and tumor size dependency analysis, demonstrate the effectiveness and robustness of the proposed method for brain tumor segmentation.

0.14

O2D-MedNet: An Optimization-Aware Dual-Domain Framework for Robust Medical Image Segmentation

cs.CV ·2026-10-26 ·Shipeng Hu, Miaohui Wang, Jing Qin, Sukun Tian, Yuchun Sun
similarity 0.66
Abstract · 16 pages, 12 figures

Medical image segmentation (MIS) remains challenging due to composite degradations and multi-scale geometric variations, which jointly impair lesion-background separability, structural consistency, and optimization stability. Existing single-stream frameworks entangle heterogeneous cues within a single representation pathway, while hybrid-stream approaches often rely on generic or static fusion, limiting effective coordination across domains and failing to explicitly address optimization instability. To overcome these limitations, we propose a new optimization-aware dual-domain framework for MIS (O2D-MedNet). First, a degradation-aware dualdomain interaction (DDI) module integrates Fourier - and Wavelet-domain features to suppress degradation-sensitive responses while preserving structural and fine-detail information. Second, a cross-backbone contour-guided fusion (CGF) module enables selective interaction between CNN-based local detail modeling and visual state-space-based global structure modeling, improving boundary accuracy and representation consistency. Third, a gradient-context optimization (GCO) strategy stabilizes training by adaptively adjusting learning dynamics based on loss trends and gradient statistics, mitigating instability caused by class imbalance and heterogeneous sample difficulty. Extensive experiments on six benchmarks demonstrate consistent improvements over state-of-the-art MIS methods across multiple imaging modalities. Further analyses confirm enhanced sensitivity, structural consistency, and optimization stability, validating the effectiveness of the proposed O2D-MedNet for robust MIS under heterogeneous conditions.

0.20

DualMiT-Net: Local-Global Transformer-Convolutional Fusion for Breast Mass Segmentation in Mammographic Regions of Interest

cs.CV cs.AIcs.LG ·2026-08-15 ·Alibek Kamiluly, Milana Muratova, Yash Patel, Fan Li
similarity 0.66
Abstract

Breast mass segmentation is an important step in computer-aided mammography, but it remains difficult because masses can have low contrast, irregular shapes, and boundaries that blend with surrounding breast tissue. To address this problem, we present DualMiT-Net, a dual-branch network that uses both a focused view of the mass and a wider view of the surrounding tissue. The local branch uses a Mix Transformer (MiT-B5) encoder to learn mass shape, texture, and boundary information, while the global branch uses an EfficientNet-B5 encoder to learn surrounding breast context. Features from the two branches are shared at the deeper encoder levels and are then progressively fused in a single decoder. A spatial gate controls how much global information is added during decoding. We also evaluated four input representations and selected a percentile-windowed mammogram combined with a Gabor texture response. The model was trained and evaluated on the mass subset of the Curated Breast Imaging Subset of the Digital Database for Screening Mammography (CBIS-DDSM) using a patient-level split. Across three training runs, DualMiT-Net with exponential moving average weights achieved a mean Dice coefficient of 0.9375 and a mean Intersection over Union of 0.8834. It also achieved better Dice and IoU scores than six standard encoder-decoder baselines trained using the same data and training settings. These results show that combining local mass information with wider breast context can provide accurate and consistent breast mass segmentation.

0.04