CS Paper Radar

Beyond Uncertainty: Generalizable Failure Monitoring for Surgical Segmentation under Acquisition Degradation

Hieu D. Pham, Dang P. M. Cao, Thanh Trung Huynh

cs.CV ·submitted 2026-08-17 15:57 UTC · v1
published

Abstract

Surgical segmentation networks can fail silently under acquisition degradation: predicted masks may be wrong even when model confidence remains high. Existing deployment-time monitors rely primarily on uncertainty estimates and can therefore miss confident failures. We present TCSR-Monitor (Temporal Conformal Surgical Risk Monitor), a post-hoc failure-monitoring framework that combines confidence with observable shape, temporal-consistency, and image-quality cues. TCSR-Monitor wraps a frozen segmentation model, requires no model internals, and operates without ground truth at deployment. We also introduce a validation protocol to assess whether alarms remain credible under distribution shift. On EndoVis 2017, leave-one-corruption-out evaluation shows that TCSR-Monitor generalizes to unseen acquisition degradations and substantially outperforms confidence-based baselines. A circularity control confirms that it predicts segmentation failure rather than simply detecting corrupted images. Mondrian conformal calibration balances miss-rates across degradation severities, but a single global threshold still produces false alarms on up to 40% of correctly segmented frames at moderate corruption. Zero-shot transfer to SAM2 demonstrates feature portability, although entropy outperforms the transferred monitor at both evaluated thresholds. Overall, reliable monitoring under acquisition degradation benefits from complementary observable signals beyond confidence alone, but substantial false-alarm and transfer limitations remain.

Comment
Accepted at MICCAI'2026 @UNSURE Workshop

Closest papers

Nearest neighbours by meaning across the whole index.

A Decision-Aware Evaluation Protocol for Uncertainty in Medical Image Segmentation

cs.CV ·2026-10-15 ·Saket Maganti, Shreyank N Gowda
similarity 0.70
Abstract

Medical segmentation uncertainty is often evaluated with calibration error or pixel-level error-detection scores, but these metrics do not show whether uncertainty improves downstream review decisions. We propose a decision-aware evaluation protocol that separates uncertainty estimation from deferral policy and evaluates their combination under fixed review budgets: which pixels, regions, or images should be accepted, and which should be reviewed. The protocol reports fixed-budget error reduction, risk-coverage behaviour, region-level review proxies, structural failure modes, probability-derived baselines, and sensitivity to review assumptions. We instantiate it across retinal vessel, skin lesion, and polyp segmentation with multiple backbones and uncertainty estimators. Under matched inference budgets and canonical multi-layer MC Dropout, test-time augmentation (TTA) gives a stronger error-detection signal across matched MC--TTA comparisons, including architecture and dropout-placement checks. However, estimator rankings are not universal. For example, probability-derived scores remain competitive, deep ensembles can outperform TTA, learned deferral helps mainly when the base estimator is weak, and rankings can change with review unit, uncertainty target, correction assumptions, and cost model. Structural and second-observer analyses further show that boundary and thin-structure failures are partly tied to annotation ambiguity. These findings support evaluating uncertainty as an estimator-policy-review configuration, not as a standalone score map. Code: https://anonymous.4open.science/r/Uncertainity-in-Medical-Image-Segmentation/README.md

0.34

Region-aware error triage for medical image segmentation with groupwise conformal risk control

cs.CV ·2026-11-06 ·Nishi Kanta Paul, Md Shihabul Islam Shovo, Hoileong Lee
similarity 0.67
Abstract · 22 pages, 7 figures, 12 tables. Submitted to Biomedical Signal Processing and Control (BSPC)

Segmentation masks are increasingly reviewed rather than redrawn, which requires knowing where a mask is likely wrong. Learned error maps rank pixels by risk, but the number of pixels to warn is chosen ad hoc, and calibrating one warning threshold over all error pixels may leave errors far from the predicted contour under-flagged. We propose RACE-Triage, a post-hoc error triage framework that leaves the segmentation mask unchanged. A risk network is trained on out-of-fold predictions from backbone-independent inputs. The predicted contour partitions each image into a boundary band and a non-boundary region, and conformal risk control is applied separately in each region to bound the expected fraction of missed errors among cases with errors there. On ISIC 2018 dermoscopy and BUSI breast ultrasound (where patient identifiers are unavailable, so independence across images is assumed), pooled control met its overall target but missed on average 31.8% and 36.4% of non-boundary errors. Regional control reduced these fractions to 19.3% and 20.9% and raised the recall of size-filtered false-negative components from 0.722 to 0.818 and from 0.611 to 0.763. The mean warned area grew by 1.6 and 4.9 percentage points, and its 95th percentile reached 23.5% and 38.5%. The effect held across three seeds and a second backbone, and area-matched heuristics did not reproduce it. On the external PH$^2$ set, frozen thresholds exceeded both targets, whereas recalibration with 100 local images brought the mean over repeated splits below them. Regional calibration improves non-boundary error coverage at a measured increase in warned area.

0.30

Cross-Model Agreement as a Deployment-Time Reliability Signal for Automatic Polyp Segmentation

cs.CV cs.LG ·2026-09-09 ·Siddharth Gupta, Jitin Singla
benchmark similarity 0.65
Abstract

In real-time colonoscopy, ground-truth annotations are unavailable at inference, so polyp segmentation models can fail silently. We propose Referee-Based Quality Estimation (RBQE), a reference-free framework measuring agreement between a primary segmentation model and an independently trained referee on the same image. RBQE is evaluated on a standardized 1,223-image external benchmark drawn from four public datasets, using four referee configurations chosen to separate two design axes: referee independence and architectural diversity. Using a common Agreement Dice descriptor, a same-architecture referee differing from the primary model only in random initialization already yields a useful reliability signal (ROC-AUC = 0.923), showing that independent training alone is sufficient. Cross-architecture referees improve further: SegFormer-B0 achieves the strongest performance (ROC-AUC = 0.960), significantly outperforming the same-architecture control and UNet++, and exceeding a representative Test-Time Augmentation baseline by 0.055 ROC-AUC under an identical protocol, whereas a prompt-coupled MedSAM referee underperforms despite maximal architectural diversity. Because empty-mask agreement is trivially separable, we also report a restricted evaluation excluding such cases: ROC-AUC falls to 0.876 (SegFormer-B0, 1,046 images) and 0.783 (same-architecture control, 975 images), yet RBQE's margin over both baselines widens on this identical subset. RBQE additionally increases the mean Dice of retained predictions as low-agreement cases are progressively rejected, supporting selective prediction, and requires only one additional deterministic referee forward pass at inference. Our study therefore supports cross-model agreement as a practical, interpretable reliability framework for automated polyp segmentation.

0.36

On the Robustness of Temporal Vision-Language Models for Surgical Endoscopy Videos

cs.CV ·2026-08-14 ·Darakshan Rashid, Raza Imam, Ufaq Khan, Muhammad Bilal, Shazad Ashraf +7 more
top venuebenchmark similarity 0.64
Abstract · Accepted to MICCAI 2026

Temporal vision-language models (TVLMs) offer a reusable, prompt-based interface for surgical video understanding, yet, their robustness under clinically realistic acquisition artifacts in endoscopy remains insufficiently characterized. In practice, degradations such as defocus, haze, motion blur, noise, cautery smoke, and packet loss introduce structured distribution shifts which may compromise video-text alignment. We study the robustness of temporal VLMs under such shifts caused by corruptions in clip frames. We introduce Endo-C6, a compact corruption benchmark of six endoscopy-realistic perturbations evaluated at a fixed high severity, and apply it to public Gastrointestinal (GI) endoscopy and laparoscopic cholecystectomy videos. Under a standardized prompt protocol, we benchmark 3 recent surgical TVLM baselines and analyze robustness in both mean and worst-case settings, spanning 294 dataset-level evaluations. Finally, we present RobustEndoCLIP, obtained by few-shot parameter-efficient tuning with VeRA, outperforming existing TVLM baselines. Our findings show that off-the-shelf TVLMs can exhibit severe worst-case collapse under endoscopy-specific corruptions, whereas lightweight few-shot adaptation can substantially improve corrupted performance and robustness without changing the prompt-based interface. We expect Endo-C6 to support standardized robustness reporting and promote more reliable clinical vision-language systems.

0.29

Evolving Error States: Failure-Aware Progressive Repair for Ultrasound Lesion Segmentation

cs.CV ·2026-09-16 ·Ziliang Wang, XuJiang Tang, Lu Yuting, Weixin Xu, Yongqiang Zhao +2 more
similarity 0.64
Abstract

Reliability under sparse and heterogeneous failures remains a fundamental challenge for medical image segmentation. High average accuracy can conceal a small set of structurally distinct and clinically consequential errors. Existing post-hoc correction methods alleviate this problem, but typically estimate false-positive and false-negative corrections from the same fixed prediction. This ignores the dynamic evolution of error states and limits the correction of complex cases. Inspired by iterative error feedback in structured prediction, we propose Failure-Aware Progressive Repair (FAPR). FAPR represents the current segmentation mask as a dynamic failure state and models each repair operation as a state-transition operator. Each accepted correction forms a new prediction state for subsequent error diagnosis and repair, enabling later operations to adapt to preceding changes. Conditional routing selectively activates necessary state transitions, while failure replay exposes the model to rare error states. By keeping the base segmentor frozen, FAPR preserves its established segmentation capability while improving difficult cases. Across three public ultrasound lesion segmentation benchmarks, FAPR improves mean DSC by 1.52%. On the very-hard subsets of BUSI and TN3K, the average gain reaches 13.77%.

0.30

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation

cs.CV ·2026-10-01 ·Samuel Hart, Ahmad Yahya, Ahmed Karam Eldaly
theory similarity 0.64
Abstract · 12 pages

While state-of-the-art automated models for medical image segmentation achieve high mean performance, they frequently suffer from localized, catastrophic failures that preclude safe clinical deployment, particularly in neuro-oncology. Interactive segmentation frameworks mitigate this by incorporating human oversight, but traditionally impose prohibitive cognitive and temporal workloads by requiring clinicians to manually search for errors. In this project, we present an efficient, Hybrid Structural-Aleatoric Human-in-the-Loop framework for glioma segmentation that bridges the gap between automated baseline performance and surgical-grade precision, achieving sub-2.0 mm HD95 on curated benchmarks while providing safety-net routing for structural failures across real-world clinical data. By extracting voxel-wise Test-Time Augmentation (TTA) uncertainty and applying hierarchical topological filtering, our method proactively isolates high-risk structural anomalies. We comprehensively evaluated our approach on a challenging out-of-distribution clinical stress-test cohort (N = 362). Operating under a simulated Human Oracle, the framework improved the Whole Tumor (WT) Dice score from 0.891 to 0.914 and reduced the 95th percentile Hausdorff Distance (HD95) from 5.82 mm to 4.76 mm. Critically for surgical safety, the system rescued severe boundary failures in the Tumor Core, reducing mean HD95 from 17.96 mm to 14.83 mm (improving absolute TC Dice to 0.356). These spatial rescues were achieved while demanding a median interactive workload of just 11.3% of the target volume. Acknowledging this as a simulated upper bound lacking real-world cognitive friction, the framework nevertheless demonstrates a highly Pareto-efficient pathway for safely deploying clinical AI.

0.15

TTDF: A Two-Stage Framework for Reliable Surgical Phase Transition Detection

cs.CV ·2026-09-13 ·Yushi Guo, Pietro Valdastri, Duygu Sarikaya
published similarity 0.64
Abstract · Accepted at the COLAS Workshop at MICCAI 2026

Reliable workflow transition detection is important for context-aware surgical assistance and downstream decision support. However, online surgical phase recognizers primarily focus on frame-wise accuracy and temporal consistency, rather than the reliability of workflow transition events. Directly converting phase changes into events is unreliable: temporal jitter and workflow-illegal switches produce false or duplicate events, while persistent, workflow-consistent candidates may remain incorrect. To address this limitation, we formulate reliable workflow transition detection as a distinct event-level task operating on outputs of a frozen online phase recognizer. We propose the Two-Stage Transition Detection Framework (TTDF), a causal framework that progressively filters transition candidates. Transition Candidate Extraction (TCE) first applies a minimum-duration requirement and a workflow-graph constraint to remove false candidates caused by temporal jitter and phase transitions not allowed by the workflow graph. Specifically, a candidate is retained only if the predicted target phase persists for a minimum duration and the ordered phase pair belongs to the workflow graph's allowed transition set. TCE thereby produces a high-recall candidate set without additional training. Transition Candidate Verification (TCV) suppresses remaining false candidates using phase-posterior shifts and visual-change cues from frozen DINOv2 features. Events are assessed using a phase-pair-aware one-to-one matching protocol. Experiments on Cholec80 show that TTDF reduces false transition emissions while preserving recall and controlling decision delay.

0.23

SCOUT: Risk-Guided Foundation-Model Escalation for Robust Tissue Detection in Whole-Slide Images

cs.CV ·2026-11-18 ·Cristian Tommasino, Antonio M. Rinaldi
benchmarkcode/data similarity 0.64
Abstract

Reliable tissue detection is essential for whole-slide image analysis, yet high average segmentation accuracy can conceal failures involving pale tissue, small fragments, and heterogeneous staining. Pathology foundation models offer transferable representations, but exhaustive inference is computationally demanding and may introduce false-positive tissue predictions. We propose SCOUT (Selective Correction of Uncertain Tissue), a risk-guided cascade that selectively refines an initial thumbnail-based tissue mask. A lightweight audit network estimates the spatial distribution of segmentation errors and prioritizes candidate regions for processing by a frozen pathology foundation model. An asymmetric consensus rule integrates the resulting predictions with the initial mask to recover missed tissue while limiting false positives. A calibrated slide-level review score additionally controls the marginal rate of unflagged case-group failures under the calibration assumptions. Evaluation on a public multi-source, multi-stain benchmark shows that SCOUT reduces the proportion of case groups requiring mask correction from 38.1% for the best released detector to 18.6%, with particularly pronounced improvements in immunohistochemistry. Source-held-out experiments demonstrate better generalization than a segmentation network trained on the same annotations, while selective inference achieves an observed failure rate no higher than processing all candidate regions. Downstream, lymph-node classification with SCOUT masks is non-inferior to that obtained with two of the three released detectors evaluated. A variant built on an openly licensed foundation model is publicly released as an installable Python package with trained weights. These results support risk-guided foundation-model inference as an effective approach to tissue detection across heterogeneous histopathology data.

0.28