CS Paper Radar

On the Robustness of Temporal Vision-Language Models for Surgical Endoscopy Videos

Darakshan Rashid, Raza Imam, Ufaq Khan, Muhammad Bilal, Shazad Ashraf, Dwarikanath Mahapatra, Mohammad Yaqub, Muhammad Haris Khan, Imran Razzak, Brejesh Lall, Lena Maier-Hein, Yutong Xie

cs.CV ·submitted 2026-08-14 12:37 UTC · v1
top venuebenchmark

Abstract

Temporal vision-language models (TVLMs) offer a reusable, prompt-based interface for surgical video understanding, yet, their robustness under clinically realistic acquisition artifacts in endoscopy remains insufficiently characterized. In practice, degradations such as defocus, haze, motion blur, noise, cautery smoke, and packet loss introduce structured distribution shifts which may compromise video-text alignment. We study the robustness of temporal VLMs under such shifts caused by corruptions in clip frames. We introduce Endo-C6, a compact corruption benchmark of six endoscopy-realistic perturbations evaluated at a fixed high severity, and apply it to public Gastrointestinal (GI) endoscopy and laparoscopic cholecystectomy videos. Under a standardized prompt protocol, we benchmark 3 recent surgical TVLM baselines and analyze robustness in both mean and worst-case settings, spanning 294 dataset-level evaluations. Finally, we present RobustEndoCLIP, obtained by few-shot parameter-efficient tuning with VeRA, outperforming existing TVLM baselines. Our findings show that off-the-shelf TVLMs can exhibit severe worst-case collapse under endoscopy-specific corruptions, whereas lightweight few-shot adaptation can substantially improve corrupted performance and robustness without changing the prompt-based interface. We expect Endo-C6 to support standardized robustness reporting and promote more reliable clinical vision-language systems.

Comment
Accepted to MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

SurgCBVR: A Multi-Domain Benchmark for Content-Based Surgical Video-to-Video Retrieval

eess.IV cs.AI ·2026-11-17 ·Mohammad Eslami, Mousa Moradi, Negin Ghamsarian, Nazlee Zebardast, Jennifer L Lindsey +4 more
benchmark similarity 0.72
Abstract

Hospitals record thousands of hours of surgical video annually, yet these archives remain difficult to search by content. Surgeons cannot readily retrieve similar operations, complications, or workflow events. Existing surgical computer vision primarily produces labels rather than retrieving relevant videos. We introduce SurgCBVR, the first benchmark for content-based video-to-video retrieval in surgery. It integrates eight public datasets across four domains-ophthalmic, laparoscopic, robotic-assisted, and colonoscopy-covering six procedure types, 679 cases, and 76,489 clips (106 hours). SurgCBVR comprises two tiers: Scene, retrieving the same operative state across cases and sites, and Workflow, retrieving and localizing phase transitions and deviations. Scene includes 74,765 clips spanning 40 classes, three temporal granularities, and three playback speeds; Workflow contains 1,724 transition clips. Fixed clip lengths and frame counts, together with phase-classifier oracle and duration-only baselines, help assess label and timing shortcuts. We evaluate six generic and surgical foundation models, two video retrieval methods, and contrastive heads trained on SurgCBVR, using within-dataset, cross-dataset, and pooled-gallery retrieval restricted to the same procedure type. Frozen representations barely outperform a timing-only baseline, transition retrieval approaches chance, and trained heads lose up to half their accuracy across datasets. These findings expose substantial limitations in current video representations and establish SurgCBVR as a benchmark for advancing surgery-aware retrieval.

0.12

Rare Disease Classification in Video Capsule Endoscopy

eess.IV q-bio.TO ·2026-09-14 ·Amit Kumar Patel, Debesh Jha
similarity 0.71
Abstract

Video capsule endoscopy offers a non-invasive way to examine the small bowel, however, the rare but clinically important findings that appear only in less than 1\% of labelled frames, provide very less signal for detection. As a result, while models can achieve high overall performance, they almost completely miss these rare findings. We condition each frame's decision on evidence from the rest of that patient's video, not on the frame's own posterior alone, supplying information a single frozen frame can never contain. Building upon Expected Gain Arbitration, a per-frame, macro-F1-optimal correction over the confusion matrix, we further compose it with video-disease-presence conditional resulting in our decoding method Hierarchical Conditional-Expected-gain (HCE). We evaluate HCE on two independent VCE datasets, Kvasir-Capsule and GALAR, against a static temporal-smoothing baseline and an optimal-transport (OT) frame-level correction. HCE significantly improves rare-class recall over a temporal-smoothing baseline on GALAR (2.7--3.1x; 95\% CI excludes zero in both scopes) and shows a similar, though not statistically confirmed, gain on Kvasir-Capsule (up to 3.4x). Against OT, HCE still improves rare-class recall in all four evaluation settings (+0.016 to +0.029), and additionally improves macro-F1 and MCC.

0.16

EndoSCOP-V: A Multi-Turn Video Understanding Evaluation Framework for Multimodal Models in Endoscopy Reporting and Clinical Reasoning

cs.CV cs.AI ·2026-11-07 ·Abhishek Tyagi, Tanmay Jain, Vilas Biradar, Krithi Krishna Koduri, Misba Hul Bashir Masoodi +13 more
published similarity 0.70
Abstract · NeurIPS 2026

Endoscopic diagnosis unfolds over native video, where a single positive finding during traversal of the gastrointestinal tract sets off a multi-minute chain of reasoning over location, morphology, severity and intervention. Existing endoscopy multimodal benchmarks test only static images or single-disease videos, which miss the temporal and clinical reasoning that real-world reporting demands. We introduce EndoSCOP-V, a video-grounded multi-turn evaluation framework for structured endoscopy reporting and clinical reasoning. It contains 1,307 real-world endoscopy and colonoscopy videos (63.2 h; 97% 1080p) averaging about 174 s. Its 20,274 question-answer turns are instantiated deterministically from clinician-filled structured endoscopy-reporting EHRs, so no per-case annotation is synthetic or LLM-rephrased. They come from 1,033 clinician-reviewed templates, about 18 per disease, that span a clinically aligned 9-task x 30-sub-task reporting taxonomy over 54 World Endoscopy Organization (WEO) MST 3.0 diseases. 22% of procedures carry co-existing pathologies, up to six per case. A Markovian context-pruned oracle-forcing protocol evaluates the dialogue turn by turn, injecting the gold answer before each subsequent turn so that per-turn reasoning is isolated from cascading dialogue errors. A panel of 15 board-certified endoscopists sets a 78% strict-accuracy baseline on 1,500 questions. Across 14 open-weight LMMs, the best 27B-class model reaches 59.8% strict accuracy, falling to 53.4% once format-trivial disease-rejection items are excluded. On a between-subjects spot-check, the best of 3 frontier proprietary models trails the clinician panel by 23 pp on strict NDR accuracy. Sub-task analysis reveals consistent gaps in quantitative measurement, multi-variable grading and intervention reasoning on long-horizon video. Data: Hugging Face (EndoSCOP-V). Code: GitHub (abhi25t/EndoSCOP-V).

0.26

EndoComparer: Comparative Surgical Video Question Answering with Pseudo-Siamese Visual Adaptation and Perceive-then-Compare Reasoning

cs.CV ·2026-11-14 ·Shi Li, Lalith Sharan, Joël L. Lavanchy, Kun Yuan, Lorenzo Arboit +6 more
benchmarkcode/data similarity 0.68
Abstract · 33 pages, 14 figures, 8 tables

Purpose: Surgical training benefits from explicit comparison between cases: in patient condition, in technique and in skill proficiency. Surgical vision-language models (VLMs) offer a promising and flexible interface for this purpose. Yet current VLMs typically see one video at a time, and they often fall short when asked to compare videos. Methods: We propose EndoComparer, a VLM for comparative surgical video question answering with two components. (a) A Pseudo-Siamese Visual LoRA (PSVL) gives each video slot its own low-rank adapter over a shared frozen vision encoder, separating the two videos in the visual pathway at the cost of a single encoder pass. (b) A Perceive-then-Compare chain of thought (PtC-CoT) trains the model to first state what each video shows, then derive the answer from these statements. We further curate EndoDiffVQA, a benchmark of nearly 11K multiple-choice questions on video-pair over cholecystectomy and gastric bypass procedures, covering anatomy, tool, action and skill. Results: EndoComparer outperforms strong generalist and surgical VLMs on detecting and specifying difference between videos. Ablations show that two proposed components contribute complimentarily, and the model remains more robust under a video-swap control that exposes confusion between the two videos. Conclusion: Providing a dedicated visual reasoning path through PSVL and PtC-CoT makes cross-case comparison of surgical videos more robust for VLMs. EndoDiffVQA and EndoComparer provide a benchmark and a strong baseline for this task. Project page: https://camma-public.github.io/endocomparer

0.19

Bootstrapping Vision-Language Model for Hysteroscopic Surgical Scene Segmentation

cs.CV ·2026-08-10 ·Jun Huang, Meiyi Chen, Zijie Yue, Yuhang Xiao, Fang Li +4 more
publishedcode/data similarity 0.66
Abstract · Accept by Biomedical Signal Processing and Control

Hysteroscopic surgical scene segmentation plays a pivotal role in understanding the hysteroscopic intraoperative environment as well as computer-assisted intervention. However, this task presents unique challenges due to the high morphological similarity among different lesions and the presence of artifacts such as specular reflections, motion blur, and fluid occlusions in surgical videos. In this work, we propose the first vision-language model (VLM)-based hysteroscopic surgical scene segmentation method, which performs pixel-wise localization for fifteen representative categories in hysteroscopic surgical scenes. Our VLM-hyster has a segmentation backbone that utilizes the pretrained image encoder for robust visual feature extraction, coupled with a transformer-based decoder for dense prediction. Moreover, we design category-specific text prompts and incorporate a masked distillation branch to filter out visual features with low correlation to the text prompts, enabling the model to focus more effectively on category-specific image regions and thereby enhancing segmentation performance. We collect a large multicentric hysteroscopic surgical scene dataset, containing 4,020 high-resolution images with detailed mask annotations, for model training and evaluation. Experimental results demonstrate that VLM-hyster substantially outperforms state-of-the-art AI models. Furthermore, extensive assessments by gynecologists, as well as multicentre and prospective validations, demonstrate VLM-hyster's robustness and generalizability. The results suggest that VLM-hyster earns considerable potential in enabling AI-assisted localization of surgical instruments and lesions in hysteroscopic surgeries. Code is available at https://github.com/viscom-tongji/VLM-hyster.

0.72

Feature-Space Latent Forecasting for Endoscopic Surgical Video Understanding

cs.CV ·2026-11-11 ·Songtao Hu, Hang Su
similarity 0.66
Abstract

Surgical workflow assistance is inherently anticipatory: systems must reason about how procedures evolve, not just recognize the current frame. However, many prior approaches perform prediction in pixel space by synthesizing future frames, which primarily focuses on appearance fidelity rather than the semantic representations required for downstream reasoning. To address this limitation, we propose a feature-space semantic forecasting framework that models temporal dynamics directly within the representations of a frozen Vision Foundation Model (VFM). Specifically, we build a hierarchical target representation from multi-layer VFM features, replace future-frame feature tokens with learnable \texttt{[MASK]} tokens, and train a masked transformer to forecast the corresponding future latent features from observed context, thereby formulating procedural evolution as masked future feature prediction. Experiments on public laparoscopic benchmarks demonstrate consistent improvements in phase anticipation, multi-label tool presence prediction, and remaining-time estimation over RGB-based forecasting baselines, while enabling a plug-and-play representation interface for lightweight downstream heads.

0.11

SCOPE-4D: Endoscopic 4D Geometry Foundation Models

cs.CV ·2026-10-01 ·Chaoyi Zhou, Zhongpai Gao, Anwesa Choudhuri, Meng Zheng, Benjamin Planche +4 more
code/data similarity 0.66
Abstract · Project page: https://chaoyizh.github.io/SCOPE-4D-page/

Geometric understanding supports endoscopic navigation and robotic assistance, but learning reliable endoscopic geometry faces two challenges: scarce geometric annotations and ambiguity between camera motion and tissue deformation. We present SCOPE-4D, an endoscopic 4D geometry foundation model that jointly predicts camera parameters, dense geometry, and 3D tissue trajectories from monocular RGB video in a single forward pass. Our curation and annotation pipeline constructs SCOPE-5K, a collection of approximately 5,000 clips spanning real and synthetic gastrointestinal endoscopy and laparoscopy. The collection provides rich geometric supervision and includes newly collected phantom and real-colonoscopy evaluation sets. Geometric supervised fine-tuning on SCOPE-5K learns endoscopic priors that improve camera and depth estimation. Common--Residual Motion (CRM) further constrains local deformation relative to common tissue movement. Together with geometric supervision, CRM and trajectory supervision further improve camera and depth estimation over geometric fine-tuning alone while enabling dense 3D tissue tracking. Evaluations on public and newly collected benchmarks demonstrate strong in-domain and out-of-domain geometry, superior 3D tracking, and more stable long-sequence colon reconstruction. A blinded user study further supports the perceived reconstruction quality on real clinical video. Together, these results demonstrate the value of large-scale endoscopic supervision and motion constraints for joint geometry estimation and tissue tracking.

0.21

A Hierarchy-Aware Video-Language Model Evaluation and Hyperbolic Baseline for Surgery

cs.CV cs.AI ·2026-09-22 ·Ana Manzano Rodríguez, Pascal Mettes, Marlies P. Schijven, Cees G. M. Snoek
similarity 0.65
Abstract

Surgical procedures follow a phase-to-step hierarchy, yet the video-language models used to recognize them are evaluated with flat per-level metrics that ignore cross-level coherence and error structure. In this paper we make two contributions to address this problem, (i) we introduce SurgHiBench, the first hierarchy-aware evaluation suite for surgical video understanding, with three tasks measuring recognition, consistency, and severity across granularity levels. We evaluate a general-purpose CLIP model, a Euclidean surgical model, and, as second contribution: (ii) HyperSurg, a new hyperbolic model that enforces phase-step containment via entailment cones, across four (existing) datasets spanning three procedure types. The suite reveals that two models with the same accuracy can produce predictions of very different error severity, ranging from sibling confusions within the correct phase to unrelated cross-phase predictions. Hyperbolic geometry shifts predictions toward the correct procedural neighborhood, and these gains scale with the tree-likeness of each dataset's annotation hierarchy, providing a principled indicator when hierarchy-aware geometry helps.

0.25