CS Paper Radar

SurgCBVR: A Multi-Domain Benchmark for Content-Based Surgical Video-to-Video Retrieval

Mohammad Eslami, Mousa Moradi, Negin Ghamsarian, Nazlee Zebardast, Jennifer L Lindsey, Sophia Y. Wang, Lucia Sobrin, Rishi P Singh, Tobias Elze

eess.IV cs.AI ·submitted 2026-11-17 11:00 UTC · v1
benchmark

Abstract

Hospitals record thousands of hours of surgical video annually, yet these archives remain difficult to search by content. Surgeons cannot readily retrieve similar operations, complications, or workflow events. Existing surgical computer vision primarily produces labels rather than retrieving relevant videos. We introduce SurgCBVR, the first benchmark for content-based video-to-video retrieval in surgery. It integrates eight public datasets across four domains-ophthalmic, laparoscopic, robotic-assisted, and colonoscopy-covering six procedure types, 679 cases, and 76,489 clips (106 hours). SurgCBVR comprises two tiers: Scene, retrieving the same operative state across cases and sites, and Workflow, retrieving and localizing phase transitions and deviations. Scene includes 74,765 clips spanning 40 classes, three temporal granularities, and three playback speeds; Workflow contains 1,724 transition clips. Fixed clip lengths and frame counts, together with phase-classifier oracle and duration-only baselines, help assess label and timing shortcuts. We evaluate six generic and surgical foundation models, two video retrieval methods, and contrastive heads trained on SurgCBVR, using within-dataset, cross-dataset, and pooled-gallery retrieval restricted to the same procedure type. Frozen representations barely outperform a timing-only baseline, transition retrieval approaches chance, and trained heads lose up to half their accuracy across datasets. These findings expose substantial limitations in current video representations and establish SurgCBVR as a benchmark for advancing surgery-aware retrieval.

Closest papers

Nearest neighbours by meaning across the whole index.

On the Robustness of Temporal Vision-Language Models for Surgical Endoscopy Videos

cs.CV ·2026-08-14 ·Darakshan Rashid, Raza Imam, Ufaq Khan, Muhammad Bilal, Shazad Ashraf +7 more
top venuebenchmark similarity 0.72
Abstract · Accepted to MICCAI 2026

Temporal vision-language models (TVLMs) offer a reusable, prompt-based interface for surgical video understanding, yet, their robustness under clinically realistic acquisition artifacts in endoscopy remains insufficiently characterized. In practice, degradations such as defocus, haze, motion blur, noise, cautery smoke, and packet loss introduce structured distribution shifts which may compromise video-text alignment. We study the robustness of temporal VLMs under such shifts caused by corruptions in clip frames. We introduce Endo-C6, a compact corruption benchmark of six endoscopy-realistic perturbations evaluated at a fixed high severity, and apply it to public Gastrointestinal (GI) endoscopy and laparoscopic cholecystectomy videos. Under a standardized prompt protocol, we benchmark 3 recent surgical TVLM baselines and analyze robustness in both mean and worst-case settings, spanning 294 dataset-level evaluations. Finally, we present RobustEndoCLIP, obtained by few-shot parameter-efficient tuning with VeRA, outperforming existing TVLM baselines. Our findings show that off-the-shelf TVLMs can exhibit severe worst-case collapse under endoscopy-specific corruptions, whereas lightweight few-shot adaptation can substantially improve corrupted performance and robustness without changing the prompt-based interface. We expect Endo-C6 to support standardized robustness reporting and promote more reliable clinical vision-language systems.

0.29

LD-RSVIS: A Large-Scale and Diverse Benchmark for Referring Surgical Video Instrument Segmentation

cs.CV ·2026-09-19 ·Zan Wang, Yunhe Feng, Dong Nie, Oluwatosin Oluwadare, Kewei Sha +2 more
benchmark similarity 0.72
Abstract

Referring surgical video instrument segmentation (RSVIS) aims at segmenting the instrument in a surgical video, given a textual description. Despite recent progress, current models are trained and assessed on relatively small-scale benchmarks, hindering the development of more general RSVIS. In addition, existing benchmarks support only the single-target expression that refers to one instrument in the video, while overlooking multi-target and no-target referring expressions, restricting the applicability of RSVIS in practical scenarios. Addressing these issues, we propose LD-RSVIS, a new benchmark aiming to facilitate more robust and general RSVIS. Specifically, LD-RSVIS consists of 3,536 surgical videos with 1.09 million frames and covers a broad set of 30 instrument classes from 25 various procedures. By including abundant videos and classes, LD-RSVIS could benefit large-scale training and evaluation of more general RSVIS methods. Besides, unlike existing datasets, LD-RSVIS offers diverse referring settings, including no-target, single-target, and multi-target expressions, which enables the development of more practical RSVIS models in real applications. In order to ensure high-quality annotations, all videos in LD-RSVIS are manually labeled with multiple rounds of inspection and refinement. To our knowledge, LD-RSVIS is the largest and most diverse benchmark for RSVIS. To analyze LD-RSVIS and to provide comparison for future research, we evaluate 12 representative methods, and the results reveal that more efforts are required for improvements. To encourage future research, we present a simple yet effective RSVIS method, dubbed Cascade-RSVIS, that first mines target-specific cues using the complementary multi-cue text information and then employs such cues and textual information for segmentation, achieving promising performance. Our benchmark and code will be released.

0.15

SurgStream: A Workflow-Anchored Proactive Streaming Framework and Benchmark for Real-Time Surgical Video Understanding

cs.CV cs.AI ·2026-11-01 ·Ruipeng Ma, Qing Xu, Jie Liang, Zhen Chen
benchmark similarity 0.71
Abstract

Surgical video understanding is essential for intraoperative assistance such as workflow monitoring, instrument preparation and procedural documentation. Delivering such assistance in real time requires a model to jointly perceive the ongoing scene, remember past surgical events, and respond before clinically relevant moments pass. Existing approaches provide limited support for jointly retaining procedural evidence and deciding when to respond in streaming surgical video. In this work, we propose SurgStream, a workflow-anchored proactive streaming framework for real-time surgical video understanding. We first introduce Workflow-Anchored Memory (WAM) to record structured instrument-action-target observations and fold them into phase-level summaries, providing compact and queryable surgical memory. Deadline-aware Transition Learning (DTL) is then devised to supervise response states within clinical windows, enabling timely responses before procedural deadlines. We further introduce SurgStream-Bench, comprising 11.7K streaming interactions across various tasks covering real-time perception, backward memory queries, forward proactive QA, proactive alerts and caption memory. Experiments on SurgStream-Bench show gains over state-of-the-art methods, especially in memory and forward proactive QA. The source code will be available.

0.20

SurgQ-VLM: Question-Conditioned Dual-Stream Compression and Answer-Type-Aware Reinforcement for Surgical Video Question Answering

cs.CV ·2026-11-01 ·Dhruv Makwana, Ananya Mantravadi
publishedcode/data similarity 0.71
Abstract · Accepted to WACV 2027 (Applications track). 16 pages: 8-page main paper, references, and supplementary material. Code: https://github.com/Dh…

Reasoning about surgical video -- which phase is underway, which instruments act, and when events occur -- underpins operative documentation, workflow analysis, and skill assessment. Yet surgical visual question answering is still largely built on single frames and closed labels that cannot express a duration, an ordering, or a count, and the video models that lift the frame limit typically compress every clip the same way regardless of the question, discarding the temporal evidence the answer needs. Worse, the answers are structurally heterogeneous, spanning five incompatible structures -- binary, classification, multi-label, counting, and sentence-temporal -- that no single training signal scores uniformly well. We propose SurgQ-VLM, a two-stage model for surgical video question answering. Stage 1 trains a question-conditioned dual-stream (slow/fast) compressor for a LoRA-adapted Qwen2.5-VL-7B: cross-attention conditions both streams on the question, and each clip's visual tokens shrink 49x from the raw ViT patches (11x vs. post-merge backbone tokens). Stage 2 post-trains with GRPO under an answer-type-aware reward that scores each question on the metric matching its answer structure (micro-F1 for label sets, normalised error for counts, a content-timing blend for temporal windows). On a sealed 21,840-question test split over Cholec80 and CholecT50, SurgQ-VLM reaches 0.779 keyword accuracy and a 10x BLEU-4 gain over zero-shot; GRPO adds 2.5 pp K-Acc (2.0 pp attributable to the answer-type-aware reward), concentrated in the structurally hard types, with answer format unchanged (ROUGE-L). Code is available at https://github.com/DhruvMakwana/SurgQ-VLM.

0.37

Artificial Intelligence for Workflow Analysis in Colorectal Surgery: A Multicentric, Cross-Procedural Development and Generalization Study

cs.CV ·2026-08-20 ·Pietro Mascagni, Julia Alekseenko, Pooja P Jain, Marta Goglia, Andrea Balla +8 more
similarity 0.70
Abstract

Minimally invasive colorectal surgeries (MIS-CRS) are characterised by significant variability and inconsistent outcomes. ColoWorkflow, a tool for the video-based assessment (VBA) of MIS-CRS workflow, was recently validated. However, manual VBA is time-consuming, limiting implementation. This study presents AI-ColoWorkflow, a deep learning model for automated surgical workflow analysis across MIS-CRS. Operative videos of MIS-CRS were collected from 4 centres and a publicly available dataset. Phases and steps were manually annotated according to ColoWorkflow. A deep learning model combining a fine-tuned DINOv3 vision transformer for per-frame visual feature extraction with a hierarchical multi-stage temporal convolutional network was jointly optimized for phase and step recognition. The model trained on pooled multicentric data, namely AI-ColoWorkflow was compared against centre-specific and procedure-specific models on a held-out test set. The following metrics were used for evaluation: macro F1 score, balanced accuracy, precision, and recall. AI-ColoWorkflow achieved a macro F1 of 73.01% $\pm$ 10.27 (balanced accuracy 73.43%) for phase recognition and 39.82% $\pm$ 7.06 (balanced accuracy 38.65%) for step recognition. The global model outperformed centre- and procedure-specific models in most experiments except procedure-specific step recognition. In the generalization analysis, mean F1 was 48.42% for phase recognition. AI-ColoWorkflow can reliably recognize MIS-CRS phases. A single model trained on pooled, multicentric, multi-procedural data generalises at least as well as and often better than centre- or procedure-specific models for phase recognition in MIS-CRS, while procedure-specific step models retain advantages for certain procedure types, motivating hybrid training strategies for future surgical AI development.

0.22

Video Based Assessment of Surgical Skills Using Frozen Pretrained Video Foundation Models

eess.IV ·2026-09-17 ·Sangrock Lee, FNU Rahul, Suvranu De
publishedbenchmark similarity 0.70
Abstract · Accepted for publication in npj Digital Medicine

Automated video-based surgical skill assessment has advanced rapidly, yet rigorous evaluation of continuous standardized score prediction under participant-level generalization to unseen trainees remains limited. We introduce VBA-Net+, a video-only framework for Fundamentals of Laparoscopic Surgery (FLS) score regression and pass-fail classification using pretrained video foundation models as frozen feature extractors. We evaluate two FLS datasets, suturing and pattern cutting, using VideoPrism, V-JEPA2, and VideoMAE v2, with a frame-level SimCLR baseline. A lightweight fully convolutional head is trained on embeddings offline and evaluated using participant-level leave-one-user-out (LOUO) cross-validation within the standardized assessment protocol. For continuous score prediction, the best representation achieves $R^2$=0.6367 for suturing and 0.9261 for pattern cutting. For pass-fail classification at official FLS thresholds, area under the receiver operating characteristic curve (AUC) reaches 0.9073 and 0.9906, respectively. Frozen video-encoder pipelines generally outperformed the frame-level SimCLR pipeline, particularly for suturing, providing a benchmark for video-only FLS assessment.

0.24

SurgSkill-Bench: A Benchmark for Multimodal Surgical Skill Assessment

cs.CV ·2026-08-31 ·Chaohui Dang, Zheheng Jiang, James Glasbey, David Luke, Theodoros Arvanitis +1 more
benchmark similarity 0.69
Abstract

Objective assessment of surgical technical skill is important for surgical training and structured feedback, but current workflows remain dependent on labor-intensive expert review. Existing automated approaches primarily focus on visual inputs and provide limited support for jointly studying operative performance, structured skill scores, and evaluator feedback. We introduce SurgSkill-Bench, an initial video-score-text benchmark-style dataset containing 214 surgical training simulation videos, six-dimensional OSATS scores, and expert free-text comments. We define two evaluation settings: video-only OSATS prediction for automated assessment and post hoc expert-comment-assisted prediction, where evaluator comments are available as auxiliary information. We provide controlled baseline experiments using representative frozen visual backbones, content-adaptive key-frame sampling, and a simple video-text co-attention fusion module. Under internal video-level validation, content-adaptive sampling improves video-only performance in this dataset, while evaluator comments provide additional score-related signal in the assisted setting. The best mean AUROC reaches 0.88 under dataset-specific median dichotomization. We further discuss evaluation constraints related to dataset scale, metadata completeness, and the interpretation of comment-assisted prediction. Code will be released publicly at a later date.

0.17

Beyond Masks and Trajectories: Flow-Guided Latent Action Injection for Stable Surgical Video Generation

cs.CV ·2026-10-07 ·Tsz-Yui Qin, Siyu Zhou, Chi-Keung Tang
similarity 0.68
Abstract

Surgical video generation holds substantial potential for surgical education, simulation, and data augmentation, yet generating surgical videos with realistic and clinically plausible motion remains challenging. Most existing methods rely on auxiliary conditions, such as masks, trajectories, depth, or reference videos, to achieve visually plausible synthesis. Yet, these auxiliary conditions typically require additional manual annotation or specialized acquisition, making it difficult to scale such methods beyond small, curated datasets. This motivates the need for a reference-free architecture capable of generating high-quality surgical video without requiring auxiliary visual conditions at inference time. We propose FLAIR, a Flow-guided LatentAction Injection framework for Reference-free surgical video generation. FLAIR learns action priors from optical flow of real surgical videos, dynamically predicts corresponding latent action representation from an input prompt, and injects it into a frozen base model to generate surgical videos with improved action consistency. We further construct SurgActionClip-30K, the first large-scale surgical vision dataset comprising action-centric segmented clips and structured caption labels, addressing the persistent lack of fine-grained, action-centric surgical datasets. Lastly, we introduce SurgMetrics, the first surgical domain-specific evaluation metrics for quantifying the quality of generated surgical videos, addressing the persistent absence of clinically grounded evaluation standards in this domain. Extensive experiments demonstrate that FLAIR enables generating high-quality surgical videos using text-only inference without auxiliary conditions, and validation in SurgMetrics demonstrates its strength in alignment with human perception compared to traditional metrics.

0.17