CS Paper Radar

Video Based Assessment of Surgical Skills Using Frozen Pretrained Video Foundation Models

Sangrock Lee, FNU Rahul, Suvranu De

eess.IV ·submitted 2026-09-17 06:38 UTC · v1
publishedbenchmark

Abstract

Automated video-based surgical skill assessment has advanced rapidly, yet rigorous evaluation of continuous standardized score prediction under participant-level generalization to unseen trainees remains limited. We introduce VBA-Net+, a video-only framework for Fundamentals of Laparoscopic Surgery (FLS) score regression and pass-fail classification using pretrained video foundation models as frozen feature extractors. We evaluate two FLS datasets, suturing and pattern cutting, using VideoPrism, V-JEPA2, and VideoMAE v2, with a frame-level SimCLR baseline. A lightweight fully convolutional head is trained on embeddings offline and evaluated using participant-level leave-one-user-out (LOUO) cross-validation within the standardized assessment protocol. For continuous score prediction, the best representation achieves $R^2$=0.6367 for suturing and 0.9261 for pattern cutting. For pass-fail classification at official FLS thresholds, area under the receiver operating characteristic curve (AUC) reaches 0.9073 and 0.9906, respectively. Frozen video-encoder pipelines generally outperformed the frame-level SimCLR pipeline, particularly for suturing, providing a benchmark for video-only FLS assessment.

Comment
Accepted for publication in npj Digital Medicine
Journal ref
npj Digital Medicine 2026
DOI
10.1038/s41746-026-03249-2

Closest papers

Nearest neighbours by meaning across the whole index.

SurgSkill-Bench: A Benchmark for Multimodal Surgical Skill Assessment

cs.CV ·2026-08-31 ·Chaohui Dang, Zheheng Jiang, James Glasbey, David Luke, Theodoros Arvanitis +1 more
benchmark similarity 0.75
Abstract

Objective assessment of surgical technical skill is important for surgical training and structured feedback, but current workflows remain dependent on labor-intensive expert review. Existing automated approaches primarily focus on visual inputs and provide limited support for jointly studying operative performance, structured skill scores, and evaluator feedback. We introduce SurgSkill-Bench, an initial video-score-text benchmark-style dataset containing 214 surgical training simulation videos, six-dimensional OSATS scores, and expert free-text comments. We define two evaluation settings: video-only OSATS prediction for automated assessment and post hoc expert-comment-assisted prediction, where evaluator comments are available as auxiliary information. We provide controlled baseline experiments using representative frozen visual backbones, content-adaptive key-frame sampling, and a simple video-text co-attention fusion module. Under internal video-level validation, content-adaptive sampling improves video-only performance in this dataset, while evaluator comments provide additional score-related signal in the assisted setting. The best mean AUROC reaches 0.88 under dataset-specific median dichotomization. We further discuss evaluation constraints related to dataset scale, metadata completeness, and the interpretation of comment-assisted prediction. Code will be released publicly at a later date.

0.17

Feature-Space Latent Forecasting for Endoscopic Surgical Video Understanding

cs.CV ·2026-11-11 ·Songtao Hu, Hang Su
similarity 0.70
Abstract

Surgical workflow assistance is inherently anticipatory: systems must reason about how procedures evolve, not just recognize the current frame. However, many prior approaches perform prediction in pixel space by synthesizing future frames, which primarily focuses on appearance fidelity rather than the semantic representations required for downstream reasoning. To address this limitation, we propose a feature-space semantic forecasting framework that models temporal dynamics directly within the representations of a frozen Vision Foundation Model (VFM). Specifically, we build a hierarchical target representation from multi-layer VFM features, replace future-frame feature tokens with learnable \texttt{[MASK]} tokens, and train a masked transformer to forecast the corresponding future latent features from observed context, thereby formulating procedural evolution as masked future feature prediction. Experiments on public laparoscopic benchmarks demonstrate consistent improvements in phase anticipation, multi-label tool presence prediction, and remaining-time estimation over RGB-based forecasting baselines, while enabling a plug-and-play representation interface for lightweight downstream heads.

0.11

SurgCBVR: A Multi-Domain Benchmark for Content-Based Surgical Video-to-Video Retrieval

eess.IV cs.AI ·2026-11-17 ·Mohammad Eslami, Mousa Moradi, Negin Ghamsarian, Nazlee Zebardast, Jennifer L Lindsey +4 more
benchmark similarity 0.70
Abstract

Hospitals record thousands of hours of surgical video annually, yet these archives remain difficult to search by content. Surgeons cannot readily retrieve similar operations, complications, or workflow events. Existing surgical computer vision primarily produces labels rather than retrieving relevant videos. We introduce SurgCBVR, the first benchmark for content-based video-to-video retrieval in surgery. It integrates eight public datasets across four domains-ophthalmic, laparoscopic, robotic-assisted, and colonoscopy-covering six procedure types, 679 cases, and 76,489 clips (106 hours). SurgCBVR comprises two tiers: Scene, retrieving the same operative state across cases and sites, and Workflow, retrieving and localizing phase transitions and deviations. Scene includes 74,765 clips spanning 40 classes, three temporal granularities, and three playback speeds; Workflow contains 1,724 transition clips. Fixed clip lengths and frame counts, together with phase-classifier oracle and duration-only baselines, help assess label and timing shortcuts. We evaluate six generic and surgical foundation models, two video retrieval methods, and contrastive heads trained on SurgCBVR, using within-dataset, cross-dataset, and pooled-gallery retrieval restricted to the same procedure type. Frozen representations barely outperform a timing-only baseline, transition retrieval approaches chance, and trained heads lose up to half their accuracy across datasets. These findings expose substantial limitations in current video representations and establish SurgCBVR as a benchmark for advancing surgery-aware retrieval.

0.12

SurGPT: A Multi-Task Foundation Model for Robotic Surgical Skills Assessment and Gesture Recognition

cs.RO ·2026-10-18 ·Parham M. Kebria, Saeid Nahavandi, Mehrdad Saif, Fernando Bello
similarity 0.70
Abstract

The assessment of surgical skills in robotic surgery training has traditionally relied on subjective evaluations by human experts, creating bottlenecks in surgical education and limiting scalability. We present a novel foundation model that automatically analyzes robotic surgical videos to provide comprehensive skill assessment and gesture understanding. Combining a visual encoder with a transformer architecture, the model performs three key tasks simultaneously: 1) surgical task classification (knot tying, needle passing, suturing), 2) skill level assessment on a standardized scale, and 3) natural language generation of surgical gesture descriptions. The model processes video sequences from the da Vinci surgical robot and generates human-readable text descriptions of surgical actions, similar to how language models generate text from prompts, using a multi-task learning framework with adaptive uncertainty weighting to optimize performance across all objectives. Our transformer-based architecture incorporates positional encoding for temporal understanding and attention mechanisms for spatiotemporal feature integration. Evaluated on the da Vinci Skills Simulator dataset, the proposed framework demonstrates state-of-the-art performance in surgical task recognition and provides interpretable skill assessments that correlate with expert evaluations, with the model's ability to generate natural language descriptions of surgical gestures opening new possibilities for automated surgical education, real-time feedback systems, and objective skill assessment in surgical training and certification programs.

0.06

Explainable AI-Powered Framework for Video-Based Skill Assessment in Cataract Surgery

cs.CV cs.AI ·2026-08-18 ·Mohammad Javad Ahmadi, Hamid D. Taghirad
dataset similarity 0.69
Abstract

Persistent shortages in the surgical workforce and inherent limitations of traditional training methods highlight the necessity of automated, data-driven approaches in surgical education. This study addresses these challenges by introducing a novel, explainable AI-powered framework for automated skill assessment, specifically focusing on cataract surgery. We present the world's largest dataset of cataract surgery videos, comprising 2,000 recordings. Additionally, we propose an AI-powered analytical framework that employs advanced computer vision and signal-processing techniques to automatically evaluate surgical videos to derive objective, quantitative performance indicators that complement or potentially replace subjective scoring methods. A significant advantage of our framework over previous methods lies precisely in its explainability of outputs, elevating it beyond merely an opaque skill classification tool. Through experimental analysis of 83 cataract surgery videos, we demonstrate that the automatically computed metrics exhibit strong correlations with expert-based subjective evaluations, achieving up to 87% accuracy in surgical skill assessment. Each metric was individually examined, and expert surgeons provided subjective ratings using the newly introduced Capsulorhexis Skill Assessment System (CSAS). These subjective assessments were compared with ten objective motion-based metrics extracted through our framework. The results indicated a robust correlation between subjective ratings and automated indicators, underscoring the framework's capacity to accurately model surgical expertise.

0.20

Looking Beyond the Scale: Do Surgical Skill Models Learn Transferable Representations Across Assessment Rubrics?

cs.CV cs.LG ·2026-08-18 ·Hanna Hoffmann, Felix von Bechtolsheim, Stefanie Speidel, Rebecca Hisey
similarity 0.69
Abstract

Vision-based surgical skill assessment has shown strong in-domain results, yet a fundamental question remains unasked: do these models learn transferable representations of surgical proficiency, or do they merely encode dataset-specific visual patterns? This paper systematically analyzes what limits cross-domain skill transfer between the GOALS and OSATS assessment scales using the LASANA and JIGSAWS datasets. Each evaluated method serves a targeted diagnostic purpose: end-to-end training to test whether supervised skill learning transfers directly, Adaptive Sharpness-Aware Minimization (ASAM) to probe whether flatter loss landscapes improve generalization, and augmentation-based self-supervised and contrastive learning to assess whether domain-invariant pretraining decouples skill from visual context. Transfer is evaluated in both directions using a disjoint-participant held-out test set for JIGSAWS. Results reveal an asymmetry: backbones pretrained on JIGSAWS achieve CCC values of 0.77 to 0.80 on LASANA, closely matching the end-to-end baseline, showing cross-rubric transfer is feasible when the target domain provides consistent supervision. Transfer to JIGSAWS fails across all methods, likely due to annotation inconsistencies. Control experiments with a Kinetics-pretrained backbone suggest task-specific heads carry the majority of the skill prediction burden, while the backbone need only provide adequate spatiotemporal features. These findings offer a new perspective on vision-based skill assessment: the central question of whether skill representations transfer across scoring systems has not been previously investigated. Results indicate the visual component is dominant but not solely responsible for skill prediction; further work is needed to conclusively disentangle transferable skill features from those bound to a specific visual domain.

0.26

Artificial Intelligence for Workflow Analysis in Colorectal Surgery: A Multicentric, Cross-Procedural Development and Generalization Study

cs.CV ·2026-08-20 ·Pietro Mascagni, Julia Alekseenko, Pooja P Jain, Marta Goglia, Andrea Balla +8 more
similarity 0.68
Abstract

Minimally invasive colorectal surgeries (MIS-CRS) are characterised by significant variability and inconsistent outcomes. ColoWorkflow, a tool for the video-based assessment (VBA) of MIS-CRS workflow, was recently validated. However, manual VBA is time-consuming, limiting implementation. This study presents AI-ColoWorkflow, a deep learning model for automated surgical workflow analysis across MIS-CRS. Operative videos of MIS-CRS were collected from 4 centres and a publicly available dataset. Phases and steps were manually annotated according to ColoWorkflow. A deep learning model combining a fine-tuned DINOv3 vision transformer for per-frame visual feature extraction with a hierarchical multi-stage temporal convolutional network was jointly optimized for phase and step recognition. The model trained on pooled multicentric data, namely AI-ColoWorkflow was compared against centre-specific and procedure-specific models on a held-out test set. The following metrics were used for evaluation: macro F1 score, balanced accuracy, precision, and recall. AI-ColoWorkflow achieved a macro F1 of 73.01% $\pm$ 10.27 (balanced accuracy 73.43%) for phase recognition and 39.82% $\pm$ 7.06 (balanced accuracy 38.65%) for step recognition. The global model outperformed centre- and procedure-specific models in most experiments except procedure-specific step recognition. In the generalization analysis, mean F1 was 48.42% for phase recognition. AI-ColoWorkflow can reliably recognize MIS-CRS phases. A single model trained on pooled, multicentric, multi-procedural data generalises at least as well as and often better than centre- or procedure-specific models for phase recognition in MIS-CRS, while procedure-specific step models retain advantages for certain procedure types, motivating hybrid training strategies for future surgical AI development.

0.22

EndoComparer: Comparative Surgical Video Question Answering with Pseudo-Siamese Visual Adaptation and Perceive-then-Compare Reasoning

cs.CV ·2026-11-14 ·Shi Li, Lalith Sharan, Joël L. Lavanchy, Kun Yuan, Lorenzo Arboit +6 more
benchmarkcode/data similarity 0.68
Abstract · 33 pages, 14 figures, 8 tables

Purpose: Surgical training benefits from explicit comparison between cases: in patient condition, in technique and in skill proficiency. Surgical vision-language models (VLMs) offer a promising and flexible interface for this purpose. Yet current VLMs typically see one video at a time, and they often fall short when asked to compare videos. Methods: We propose EndoComparer, a VLM for comparative surgical video question answering with two components. (a) A Pseudo-Siamese Visual LoRA (PSVL) gives each video slot its own low-rank adapter over a shared frozen vision encoder, separating the two videos in the visual pathway at the cost of a single encoder pass. (b) A Perceive-then-Compare chain of thought (PtC-CoT) trains the model to first state what each video shows, then derive the answer from these statements. We further curate EndoDiffVQA, a benchmark of nearly 11K multiple-choice questions on video-pair over cholecystectomy and gastric bypass procedures, covering anatomy, tool, action and skill. Results: EndoComparer outperforms strong generalist and surgical VLMs on detecting and specifying difference between videos. Ablations show that two proposed components contribute complimentarily, and the model remains more robust under a video-swap control that exposes confusion between the two videos. Conclusion: Providing a dedicated visual reasoning path through PSVL and PtC-CoT makes cross-case comparison of surgical videos more robust for VLMs. EndoDiffVQA and EndoComparer provide a benchmark and a strong baseline for this task. Project page: https://camma-public.github.io/endocomparer

0.19