Cross-Model Agreement as a Deployment-Time Reliability Signal for Automatic Polyp Segmentation

Siddharth Gupta, Jitin Singla

cs.CV cs.LG ·submitted 2026-09-09 17:32 UTC · v1
benchmark

Abstract

In real-time colonoscopy, ground-truth annotations are unavailable at inference, so polyp segmentation models can fail silently. We propose Referee-Based Quality Estimation (RBQE), a reference-free framework measuring agreement between a primary segmentation model and an independently trained referee on the same image. RBQE is evaluated on a standardized 1,223-image external benchmark drawn from four public datasets, using four referee configurations chosen to separate two design axes: referee independence and architectural diversity. Using a common Agreement Dice descriptor, a same-architecture referee differing from the primary model only in random initialization already yields a useful reliability signal (ROC-AUC = 0.923), showing that independent training alone is sufficient. Cross-architecture referees improve further: SegFormer-B0 achieves the strongest performance (ROC-AUC = 0.960), significantly outperforming the same-architecture control and UNet++, and exceeding a representative Test-Time Augmentation baseline by 0.055 ROC-AUC under an identical protocol, whereas a prompt-coupled MedSAM referee underperforms despite maximal architectural diversity. Because empty-mask agreement is trivially separable, we also report a restricted evaluation excluding such cases: ROC-AUC falls to 0.876 (SegFormer-B0, 1,046 images) and 0.783 (same-architecture control, 975 images), yet RBQE's margin over both baselines widens on this identical subset. RBQE additionally increases the mean Dice of retained predictions as low-agreement cases are progressively rejected, supporting selective prediction, and requires only one additional deterministic referee forward pass at inference. Our study therefore supports cross-model agreement as a practical, interpretable reliability framework for automated polyp segmentation.

Closest papers

Nearest neighbours by meaning across the whole index.

TRUE-Colon: Exposing a Consistent Transfer Asymmetry in Real-Time Polyp Detection

eess.IV cs.CVcs.LG ·2026-08-13 ·Sebastian Doerrich, Andreas Franz Schwab, Francesco Di Salvo, Shyam Nandan Rai, Hanh Huyen My Nguyen +1 more
publishedcode/data similarity 0.70
Abstract · Accepted to EndoLINA @ MICCAI 2026 (The International Workshop on Endoluminal Intervention Navigation and Autonomy)

Computer-aided detection (CADe) systems for colonoscopy promise to reduce clinical miss rates, yet reliable real-world deployment remains elusive. This translational gap stems in part from a structural flaw in model development: the reliance on curated datasets that under-represent the long negative stretches and procedure-related artifacts characteristic of routine examinations. Training and evaluating architectures strictly on these lesion-centric benchmarks creates an illusion of success, since such benchmarks cannot capture clinically crucial metrics. To expose this gap, we establish TRUE-Colon, a standardized benchmarking protocol that measures key deployment characteristics alongside localization accuracy, and evaluate four real-time architectures (Faster R-CNN, YOLOv8, YOLOv11, RT-DETR) across curated benchmarks (SUN, PICCOLO) and 60 unedited, full-length procedures (REAL-Colon). We observe a consistent transfer asymmetry: models trained strictly on curated clips suffer a severe performance collapse when evaluated on full procedures, whereas procedure-trained models substantially improve rejection of non-polyp content on REAL-Colon, and largely retain their accuracy on curated benchmarks. Beyond transferability, we find that the Transformer detector attains the strongest sensitivity and the earliest, most persistent detections, while the convolutional detectors stay competitive at a higher throughput. Together, these results indicate that both training and benchmarking for deployable CADe should shift from curated, lesion-centric clips toward full-procedure data and deployment-relevant operating points. Source code is available at https://github.com/sdoerrich97/true-colon.

0.38

A Decision-Aware Evaluation Protocol for Uncertainty in Medical Image Segmentation

cs.CV ·2026-10-15 ·Saket Maganti, Shreyank N Gowda
similarity 0.66
Abstract

Medical segmentation uncertainty is often evaluated with calibration error or pixel-level error-detection scores, but these metrics do not show whether uncertainty improves downstream review decisions. We propose a decision-aware evaluation protocol that separates uncertainty estimation from deferral policy and evaluates their combination under fixed review budgets: which pixels, regions, or images should be accepted, and which should be reviewed. The protocol reports fixed-budget error reduction, risk-coverage behaviour, region-level review proxies, structural failure modes, probability-derived baselines, and sensitivity to review assumptions. We instantiate it across retinal vessel, skin lesion, and polyp segmentation with multiple backbones and uncertainty estimators. Under matched inference budgets and canonical multi-layer MC Dropout, test-time augmentation (TTA) gives a stronger error-detection signal across matched MC--TTA comparisons, including architecture and dropout-placement checks. However, estimator rankings are not universal. For example, probability-derived scores remain competitive, deep ensembles can outperform TTA, learned deferral helps mainly when the base estimator is weak, and rankings can change with review unit, uncertainty target, correction assumptions, and cost model. Structural and second-observer analyses further show that boundary and thin-structure failures are partly tied to annotation ambiguity. These findings support evaluating uncertainty as an estimator-policy-review configuration, not as a standalone score map. Code: https://anonymous.4open.science/r/Uncertainity-in-Medical-Image-Segmentation/README.md

0.34

Beyond Uncertainty: Generalizable Failure Monitoring for Surgical Segmentation under Acquisition Degradation

cs.CV ·2026-08-17 ·Hieu D. Pham, Dang P. M. Cao, Thanh Trung Huynh
published similarity 0.65
Abstract · Accepted at MICCAI'2026 @UNSURE Workshop

Surgical segmentation networks can fail silently under acquisition degradation: predicted masks may be wrong even when model confidence remains high. Existing deployment-time monitors rely primarily on uncertainty estimates and can therefore miss confident failures. We present TCSR-Monitor (Temporal Conformal Surgical Risk Monitor), a post-hoc failure-monitoring framework that combines confidence with observable shape, temporal-consistency, and image-quality cues. TCSR-Monitor wraps a frozen segmentation model, requires no model internals, and operates without ground truth at deployment. We also introduce a validation protocol to assess whether alarms remain credible under distribution shift. On EndoVis 2017, leave-one-corruption-out evaluation shows that TCSR-Monitor generalizes to unseen acquisition degradations and substantially outperforms confidence-based baselines. A circularity control confirms that it predicts segmentation failure rather than simply detecting corrupted images. Mondrian conformal calibration balances miss-rates across degradation severities, but a single global threshold still produces false alarms on up to 40% of correctly segmented frames at moderate corruption. Zero-shot transfer to SAM2 demonstrates feature portability, although entropy outperforms the transferred monitor at both evaluated thresholds. Overall, reliable monitoring under acquisition degradation benefits from complementary observable signals beyond confidence alone, but substantial false-alarm and transfer limitations remain.

0.34

MedSegBenchmarker: A Raw-Count-First Framework for Controlled 2D Medical Image Segmentation Benchmarks

cs.CV cs.AI ·2026-08-30 ·Vanessa Borst, Lukas Horn, Daniel Grillmeyer, Thomas Prantl, Samuel Kounev
benchmark similarity 0.63
Abstract · 10 pages, 4 figures;

Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

0.46

CSG-Mamba: A Convolutional Scoring Gating Vision State Space Network for Endoscopic Polyp Segmentation

cs.CV ·2026-08-14 ·Yuliang Wang, Jiaqi Wu, Jiaye Song, Shuxia Ren
published similarity 0.63
Abstract · 14 pages, 6 figures, and 5 tables. Accepted by ICONIP 2026

Accurate polyp segmentation is critical for computer-aided colonoscopy, yet endoscopic images often contain low-contrast boundaries, mucosal texture interference, specular highlights, and device-dependent appearance shifts. Vision State Space Models (SSMs) provide efficient long-range modeling with linear complexity, but existing Vision Mamba segmentation models typically convert 2D features into 1D scanning sequences, which may weaken local geometric continuity and over-smooth irregular contours. We propose CSG-Mamba, a convolutional scoring gating Vision State Space network for endoscopic polyp segmentation. Built on a VM-UNet-style asymmetric U-shaped encoder-decoder, CSG-Mamba inserts a Convolutional Scoring Gating (CSG) module at the semantically rich bottleneck. CSG generates a local spatial score map through pointwise and large-kernel depthwise convolutions and recalibrates state-space features by multiplicative gating. Experiments with three random seeds show that CSG-Mamba achieves 0.9220 Dice and 15.87 HD95 on Kvasir-SEG, and 0.7418 Dice and 0.6570 mIoU on CVC-ColonDB, outperforming the baselines on most overlap and recall metrics while maintaining competitive boundary accuracy.

0.28

Lightweight Frame Compensation for Real-Time Polyp Segmentation under Frame Skipping

cs.CV ·2026-10-22 ·Weihao Gao
similarity 0.63
Abstract · Subsequent analysis revealed a flaw in the evaluation protocol of the proposed lightweight frame compensation. The original experiments did …

Real-time polyp segmentation in computer-assisted colonoscopy is hampered by the difficulty of deploying high-accuracy models under strict latency budgets. Frame skipping, which performs inference every K frames and reuses or interpolates the rest, improves throughput but introduces motion blur and lesion misalignment that degrade temporal consistency. To close this gap, we propose the Lightweight Frame Compensator (LFC), a 77K-parameter plug-and-play module inserted before a frozen segmentation backbone. Operating on a three-frame window, LFC fuses consecutive frames via spatio-temporal attention into a single compensated frame, and is trained only on pseudo-labels generated by a differently seeded model, without any expert annotation. Experiments on three polyp video benchmarks show that LFC recovers most of the accuracy degraded by direct frame skipping and, in several settings, reaches the accuracy of frame-by-frame inference, while retaining a 2.05X--2.55X throughput gain. We further evaluate the temporal stability of three backbones spanning CNN, pyramid Transformer, and global-attention Transformer architectures, revealing a spectrum of sensitivity to frame skipping that arises from how locally or globally each architecture aggregates misaligned input. The compensation gain of LFC follows this spectrum: it is largest for high-capacity Transformer backbones, which achieve the best static accuracy but suffer the most under skip-frame inference. LFC thus offers a lightweight, pluggable, and deployment-friendly route to real-time polyp segmentation.

0.18

Beyond Ground Truth: A Heuristic Unsupervised Quality Assurance Engine for Diagnosing Calibrational Blindness in Dental Segmentation

cs.CV ·2026-10-29 ·Fatematuj Johura Mim
top venue similarity 0.62
Abstract · Accepted at 11th IEEE Asia-Pacific Conference on Computer Science and Data Engineering (IEEE CSDE 2026), Cox's Bazar, Bangladesh. Copyright …

In real-world clinical settings, dental X-ray segmentation using deep learning methods suffers from reliability issues. Even when the segmentation quality is bad, deep learning models show high confidence in their predictions (calibrational blindness). Moreover, in real use, doctors do not have ground-truth masks to check their accuracy. To address this problem, we introduce a simple quality-checking engine called HUS-QA with three stages. We train it on the PRAD (Periapical Dental X-ray) dataset to build our SimCLR self-supervised ResNet-18 U-Net model, which generates the segmentation mask and then evaluates its quality. Our HUS-QA checks the segmentation mask quality without a ground-truth mask. Prediction confidence, edge sharpness, shape connectivity, and area-size penalty are the simple indicators considered in this research. Results show that standard confidence methods fail (r = -0.1394, p = 1.7864e-3, ROC AUC = 0.4275). By contrast, our HUS-QA shows a positive correlation with actual Dice scores (r = 0.4647, p = 3.7510e-28) and achieves a strong ROC-AUC of 0.8405. Therefore, HUS-QA serves as a practical tool for clinical quality control.

0.43

Polyp-VSSD: A Pre-trained Transformer with Local-Global Joint VSSD Decoding for Polyp Segmentation

cs.CV ·2026-10-23 ·Xiaobo Zhu, Shiwei Wu, Yu An, Yuechen Tao, He Sun +2 more
similarity 0.62
Abstract

Early detection of colorectal polyps is essential for preventing colorectal cancer, making accurate polyp segmentation a key component in computer-aided diagnosis systems. However, existing endoscopic segmentation methods often exhibit limited representational capacity and insufficient integration of global and local contextual information. To address these limitations, we propose Polyp-VSSD, a novel local-global joint decoding framework built upon a pre-trained Transformer backbone for high-precision polyp segmentation. Polyp-VSSD leverages the strong feature expressiveness of large-scale visual pre-training and unifies global semantic modeling with local fine-grained reconstruction to enhance segmentation fidelity. Extensive experiments on multiple public endoscopic datasets demonstrate that our approach significantly outperforms state-of-the-art methods in both Dice and IoU. On the EndoScene dataset, Polyp-VSSD achieves mIoU and mDice scores of 0.903 and 0.946, respectively, highlighting its robustness and strong generalization capability. This work presents an effective and scalable solution for intelligent endoscopic image analysis.

0.25