CS Paper Radar

TRUE-Colon: Exposing a Consistent Transfer Asymmetry in Real-Time Polyp Detection

Sebastian Doerrich, Andreas Franz Schwab, Francesco Di Salvo, Shyam Nandan Rai, Hanh Huyen My Nguyen, Christian Ledig

eess.IV cs.CVcs.LG ·submitted 2026-08-13 19:13 UTC · v1
publishedcode/data

Abstract

Computer-aided detection (CADe) systems for colonoscopy promise to reduce clinical miss rates, yet reliable real-world deployment remains elusive. This translational gap stems in part from a structural flaw in model development: the reliance on curated datasets that under-represent the long negative stretches and procedure-related artifacts characteristic of routine examinations. Training and evaluating architectures strictly on these lesion-centric benchmarks creates an illusion of success, since such benchmarks cannot capture clinically crucial metrics. To expose this gap, we establish TRUE-Colon, a standardized benchmarking protocol that measures key deployment characteristics alongside localization accuracy, and evaluate four real-time architectures (Faster R-CNN, YOLOv8, YOLOv11, RT-DETR) across curated benchmarks (SUN, PICCOLO) and 60 unedited, full-length procedures (REAL-Colon). We observe a consistent transfer asymmetry: models trained strictly on curated clips suffer a severe performance collapse when evaluated on full procedures, whereas procedure-trained models substantially improve rejection of non-polyp content on REAL-Colon, and largely retain their accuracy on curated benchmarks. Beyond transferability, we find that the Transformer detector attains the strongest sensitivity and the earliest, most persistent detections, while the convolutional detectors stay competitive at a higher throughput. Together, these results indicate that both training and benchmarking for deployable CADe should shift from curated, lesion-centric clips toward full-procedure data and deployment-relevant operating points. Source code is available at https://github.com/sdoerrich97/true-colon.

Comment
Accepted to EndoLINA @ MICCAI 2026 (The International Workshop on Endoluminal Intervention Navigation and Autonomy)

Closest papers

Nearest neighbours by meaning across the whole index.

woma: a real-time foundation model and its fine-tuned models for endoscopy

cs.SE cs.CVcs.LG ·2026-09-14 ·Thang Tran, Lan Dang
code/data similarity 0.71
Abstract · 28 pages, 10 figures (8 in the main text, 2 supplementary), 13 tables (8 in the main text, 5 supplementary). Preprint. Models and run record…

woma is a real-time foundation model for gastrointestinal endoscopy: a network trained without labels on about a million endoscopy frames, from which task models are fine-tuned. We contribute a systematic design for production. Requirements and pass marks were fixed before any run, eight candidates screened under pre-registered rules, self-supervised training taken to a stopping rule, then fine-tuning and deployment optimisation, all on one self-contained library, numbat. We also contribute woma itself with two fine-tuned models, every outcome reported met or missed. Our colonoscopy model finds and outlines polyps, names which colon segment is in view, suggests polyp type and grades bowel preparation. Our gastroscopy model names a station out of 22 protocol sites, flags and outlines lesions, and names one of seven findings. Every number was read on data never seen in training, and shipped weights were chosen on that record. In colonoscopy, 96% of polyps in a six-hospital PolypGen set are found at precision >=0.85, and 19 of 19 polyps across fifteen full REAL-Colon videos at 1.6 false alarms per procedure. In gastroscopy, landmark region is named correctly on 92% of frames from unseen patients, and 37 of 39 held-out neoplasia frames are flagged at specificity 0.91. On one workstation GPU every task runs over 1080p video at about 100 frames per second, faster than PyTorch, ONNX Runtime and TensorRT in all four precision regimes tested. TensorRT comes closest: one pass of our foundation model takes it 3 to 27% longer than ours, and we deliver 6 to 31% more frames per second from frame to results. A second build links no vendor library at all -- our own kernels over Vulkan -- so a site deploys two files and needs no toolkit, no cuDNN and no framework; in f32 it beats the CUDA build on the same card.

0.56

Cross-Model Agreement as a Deployment-Time Reliability Signal for Automatic Polyp Segmentation

cs.CV cs.LG ·2026-09-09 ·Siddharth Gupta, Jitin Singla
benchmark similarity 0.70
Abstract

In real-time colonoscopy, ground-truth annotations are unavailable at inference, so polyp segmentation models can fail silently. We propose Referee-Based Quality Estimation (RBQE), a reference-free framework measuring agreement between a primary segmentation model and an independently trained referee on the same image. RBQE is evaluated on a standardized 1,223-image external benchmark drawn from four public datasets, using four referee configurations chosen to separate two design axes: referee independence and architectural diversity. Using a common Agreement Dice descriptor, a same-architecture referee differing from the primary model only in random initialization already yields a useful reliability signal (ROC-AUC = 0.923), showing that independent training alone is sufficient. Cross-architecture referees improve further: SegFormer-B0 achieves the strongest performance (ROC-AUC = 0.960), significantly outperforming the same-architecture control and UNet++, and exceeding a representative Test-Time Augmentation baseline by 0.055 ROC-AUC under an identical protocol, whereas a prompt-coupled MedSAM referee underperforms despite maximal architectural diversity. Because empty-mask agreement is trivially separable, we also report a restricted evaluation excluding such cases: ROC-AUC falls to 0.876 (SegFormer-B0, 1,046 images) and 0.783 (same-architecture control, 975 images), yet RBQE's margin over both baselines widens on this identical subset. RBQE additionally increases the mean Dice of retained predictions as low-agreement cases are progressively rejected, supporting selective prediction, and requires only one additional deterministic referee forward pass at inference. Our study therefore supports cross-model agreement as a practical, interpretable reliability framework for automated polyp segmentation.

0.36

Lightweight Frame Compensation for Real-Time Polyp Segmentation under Frame Skipping

cs.CV ·2026-10-22 ·Weihao Gao
similarity 0.66
Abstract · Subsequent analysis revealed a flaw in the evaluation protocol of the proposed lightweight frame compensation. The original experiments did …

Real-time polyp segmentation in computer-assisted colonoscopy is hampered by the difficulty of deploying high-accuracy models under strict latency budgets. Frame skipping, which performs inference every K frames and reuses or interpolates the rest, improves throughput but introduces motion blur and lesion misalignment that degrade temporal consistency. To close this gap, we propose the Lightweight Frame Compensator (LFC), a 77K-parameter plug-and-play module inserted before a frozen segmentation backbone. Operating on a three-frame window, LFC fuses consecutive frames via spatio-temporal attention into a single compensated frame, and is trained only on pseudo-labels generated by a differently seeded model, without any expert annotation. Experiments on three polyp video benchmarks show that LFC recovers most of the accuracy degraded by direct frame skipping and, in several settings, reaches the accuracy of frame-by-frame inference, while retaining a 2.05X--2.55X throughput gain. We further evaluate the temporal stability of three backbones spanning CNN, pyramid Transformer, and global-attention Transformer architectures, revealing a spectrum of sensitivity to frame skipping that arises from how locally or globally each architecture aggregates misaligned input. The compensation gain of LFC follows this spectrum: it is largest for high-capacity Transformer backbones, which achieve the best static accuracy but suffer the most under skip-frame inference. LFC thus offers a lightweight, pluggable, and deployment-friendly route to real-time polyp segmentation.

0.18

Annotation-Free Representation Learning for Polyp Retrieval in Colonoscopy Videos

cs.CV ·2026-10-29 ·Luca Parolari, Lamberto Ballan, Carlo Biffi, Loic Le Folgoc
code/data similarity 0.66
Abstract · Under submission at ISBI 2027

Colonoscopy is inherently comparative: reliable visual assessment of polyps often depends on complementary views acquired under different viewpoints and imaging conditions. Retrieving such views requires polyp tracklet representations, which recent contrastive methods learn from temporal cues but still build from manually annotated bounding boxes. We propose an annotation-free framework that constructs tracklet views directly from raw colonoscopy videos, enabling temporal self-supervised learning on full-procedure videos, including frames without visible polyps. On REAL-Colon, our method achieves state-of-the-art results on tracklet retrieval and re-identification, outperforming both self-supervised and supervised baselines. We then introduce few-shot polyp retrieval, a task closer to clinical use, where a few observations of a target polyp are used to retrieve its remaining tracklets: with only two examples, our method surpasses most competing methods given ten. Finally, we show that a modest number of unlabeled procedures suffices for competitive performance, making on-site model development more practical. Code is available at https://github.com/lparolari/freerep.

0.28

On the Robustness of Temporal Vision-Language Models for Surgical Endoscopy Videos

cs.CV ·2026-08-14 ·Darakshan Rashid, Raza Imam, Ufaq Khan, Muhammad Bilal, Shazad Ashraf +7 more
top venuebenchmark similarity 0.65
Abstract · Accepted to MICCAI 2026

Temporal vision-language models (TVLMs) offer a reusable, prompt-based interface for surgical video understanding, yet, their robustness under clinically realistic acquisition artifacts in endoscopy remains insufficiently characterized. In practice, degradations such as defocus, haze, motion blur, noise, cautery smoke, and packet loss introduce structured distribution shifts which may compromise video-text alignment. We study the robustness of temporal VLMs under such shifts caused by corruptions in clip frames. We introduce Endo-C6, a compact corruption benchmark of six endoscopy-realistic perturbations evaluated at a fixed high severity, and apply it to public Gastrointestinal (GI) endoscopy and laparoscopic cholecystectomy videos. Under a standardized prompt protocol, we benchmark 3 recent surgical TVLM baselines and analyze robustness in both mean and worst-case settings, spanning 294 dataset-level evaluations. Finally, we present RobustEndoCLIP, obtained by few-shot parameter-efficient tuning with VeRA, outperforming existing TVLM baselines. Our findings show that off-the-shelf TVLMs can exhibit severe worst-case collapse under endoscopy-specific corruptions, whereas lightweight few-shot adaptation can substantially improve corrupted performance and robustness without changing the prompt-based interface. We expect Endo-C6 to support standardized robustness reporting and promote more reliable clinical vision-language systems.

0.29

Polyp Matching Using Deep Learning

cs.CV cs.AI ·2026-11-03 ·Kristian Dalsbø Hindberg, Puneet Sharma, Benedicte Schelde-Olesen, Ulrik Deding, Jakob Frederik Frøkjær Justsen +2 more
hot direction similarity 0.65
Abstract

A key challenge in colon capsule endoscopy (CCE) analysis is accurately identifying whether multiple images depict the same polyp, which is critical to avoid over-counting and unnecessary clinical interventions. Additionally, this prevents prolonged follow-up colonoscopies where endoscopists search for duplicate polyps without precise localization. This study presents a novel contrastive learning-based approach to polyp matching using a Siamese neural network architecture. The model was trained on a dataset from the Danish CareForColon2015 trial. The dataset comprises 5,103 image pairs of confirmed same polyp and 5,103 pairs of different polyps, annotated by experienced clinicians. The proposed model employs ResNet variants (ResNet18, ResNet34, ResNet50), DenseNet121 and EfficientNet B0/B3 as backbones and utilizes contrastive learning with cosine vector distance metric for classification. Experimental results demonstrate high classification accuracies of up to 92% and AUC values close to 0.98. These results suggest that automated polyp matching has the potential to reduce polyp over-counting, improve patient risk stratification, and reduce unnecessary follow-up colonoscopies.

0.30

EndoSCOP-V: A Multi-Turn Video Understanding Evaluation Framework for Multimodal Models in Endoscopy Reporting and Clinical Reasoning

cs.CV cs.AI ·2026-11-07 ·Abhishek Tyagi, Tanmay Jain, Vilas Biradar, Krithi Krishna Koduri, Misba Hul Bashir Masoodi +13 more
published similarity 0.64
Abstract · NeurIPS 2026

Endoscopic diagnosis unfolds over native video, where a single positive finding during traversal of the gastrointestinal tract sets off a multi-minute chain of reasoning over location, morphology, severity and intervention. Existing endoscopy multimodal benchmarks test only static images or single-disease videos, which miss the temporal and clinical reasoning that real-world reporting demands. We introduce EndoSCOP-V, a video-grounded multi-turn evaluation framework for structured endoscopy reporting and clinical reasoning. It contains 1,307 real-world endoscopy and colonoscopy videos (63.2 h; 97% 1080p) averaging about 174 s. Its 20,274 question-answer turns are instantiated deterministically from clinician-filled structured endoscopy-reporting EHRs, so no per-case annotation is synthetic or LLM-rephrased. They come from 1,033 clinician-reviewed templates, about 18 per disease, that span a clinically aligned 9-task x 30-sub-task reporting taxonomy over 54 World Endoscopy Organization (WEO) MST 3.0 diseases. 22% of procedures carry co-existing pathologies, up to six per case. A Markovian context-pruned oracle-forcing protocol evaluates the dialogue turn by turn, injecting the gold answer before each subsequent turn so that per-turn reasoning is isolated from cascading dialogue errors. A panel of 15 board-certified endoscopists sets a 78% strict-accuracy baseline on 1,500 questions. Across 14 open-weight LMMs, the best 27B-class model reaches 59.8% strict accuracy, falling to 53.4% once format-trivial disease-rejection items are excluded. On a between-subjects spot-check, the best of 3 frontier proprietary models trails the clinician panel by 23 pp on strict NDR accuracy. Sub-task analysis reveals consistent gaps in quantitative measurement, multi-variable grading and intervention reasoning on long-horizon video. Data: Hugging Face (EndoSCOP-V). Code: GitHub (abhi25t/EndoSCOP-V).

0.26

Rare Disease Classification in Video Capsule Endoscopy

eess.IV q-bio.TO ·2026-09-14 ·Amit Kumar Patel, Debesh Jha
similarity 0.64
Abstract

Video capsule endoscopy offers a non-invasive way to examine the small bowel, however, the rare but clinically important findings that appear only in less than 1\% of labelled frames, provide very less signal for detection. As a result, while models can achieve high overall performance, they almost completely miss these rare findings. We condition each frame's decision on evidence from the rest of that patient's video, not on the frame's own posterior alone, supplying information a single frozen frame can never contain. Building upon Expected Gain Arbitration, a per-frame, macro-F1-optimal correction over the confusion matrix, we further compose it with video-disease-presence conditional resulting in our decoding method Hierarchical Conditional-Expected-gain (HCE). We evaluate HCE on two independent VCE datasets, Kvasir-Capsule and GALAR, against a static temporal-smoothing baseline and an optimal-transport (OT) frame-level correction. HCE significantly improves rare-class recall over a temporal-smoothing baseline on GALAR (2.7--3.1x; 95\% CI excludes zero in both scopes) and shows a similar, though not statistically confirmed, gain on Kvasir-Capsule (up to 3.4x). Against OT, HCE still improves rare-class recall in all four evaluation settings (+0.016 to +0.029), and additionally improves macro-F1 and MCC.

0.16