CS Paper Radar

Polyp Matching Using Deep Learning

Kristian Dalsbø Hindberg, Puneet Sharma, Benedicte Schelde-Olesen, Ulrik Deding, Jakob Frederik Frøkjær Justsen, Jan-Matthias Braun, Esmaeil S. Nadimi

cs.CV cs.AI ·submitted 2026-11-03 10:13 UTC · v1
hot direction

Abstract

A key challenge in colon capsule endoscopy (CCE) analysis is accurately identifying whether multiple images depict the same polyp, which is critical to avoid over-counting and unnecessary clinical interventions. Additionally, this prevents prolonged follow-up colonoscopies where endoscopists search for duplicate polyps without precise localization. This study presents a novel contrastive learning-based approach to polyp matching using a Siamese neural network architecture. The model was trained on a dataset from the Danish CareForColon2015 trial. The dataset comprises 5,103 image pairs of confirmed same polyp and 5,103 pairs of different polyps, annotated by experienced clinicians. The proposed model employs ResNet variants (ResNet18, ResNet34, ResNet50), DenseNet121 and EfficientNet B0/B3 as backbones and utilizes contrastive learning with cosine vector distance metric for classification. Experimental results demonstrate high classification accuracies of up to 92% and AUC values close to 0.98. These results suggest that automated polyp matching has the potential to reduce polyp over-counting, improve patient risk stratification, and reduce unnecessary follow-up colonoscopies.

Closest papers

Nearest neighbours by meaning across the whole index.

PolypVision: A Three-Stage Hierarchical Deep Learning Framework for Classification and Segmentation of Colorectal Polyps

cs.CV ·2026-08-11 ·Hamidreza Bolhasani, Hamidreza Rastad, Amir Mohammad Akbari, Mohammad Tashakoripour, Parnian Asadollahi +2 more
similarity 0.68
Abstract

Colorectal cancer (CRC) remains one of the leading causes of cancer-related mortality worldwide, predominantly arising from precancerous polyps. Accurate detection, segmentation, and endoscopic and histological classification of colorectal polyps are crucial for timely clinical intervention. In this study, we present PolypVision, a three-stage hierarchical deep learning framework that sequentially performs: (Stage 1) binary classification of polyps as adenomatous or hyperplastic, with simultaneous Paris and JNet classification, using EfficientNetV2-M with Focal Loss; (Stage 2) polyp segmentation with recommended resection method using a UNet++ decoder with the Stage 1 backbone as encoder, optimized with Dice and BCE losses; and (Stage 3) adenoma subtype classification (tubular, tubulovillous, villous) using EfficientNetV2-M with transfer learning from Stage 2. Evaluated on three public datasets -- PolypGen, Kvasir-SEG, and CVC-ClinicDB -- PolypVision achieves an AUC of approximately 0.99 for frame classification and a detection mAP@50 of 94.4% on Kvasir-SEG, outperforming or matching state-of-the-art methods. Gradient-weighted Class Activation Maps (Grad-CAM) confirm that the model attends to clinically relevant lesion features. The framework is device-independent, operating across diverse endoscopic imaging systems without hardware-specific adaptation. These results demonstrate that a hierarchical, transfer-learning-driven pipeline with task-specific loss functions offers a robust, device-independent, and clinically meaningful approach to automated colorectal polyp analysis. PolypVision is freely available as a web application at https://polypvision.com, a DataBioX initiative, with a free usage tier open to all users.

0.16

TRUE-Colon: Exposing a Consistent Transfer Asymmetry in Real-Time Polyp Detection

eess.IV cs.CVcs.LG ·2026-08-13 ·Sebastian Doerrich, Andreas Franz Schwab, Francesco Di Salvo, Shyam Nandan Rai, Hanh Huyen My Nguyen +1 more
publishedcode/data similarity 0.65
Abstract · Accepted to EndoLINA @ MICCAI 2026 (The International Workshop on Endoluminal Intervention Navigation and Autonomy)

Computer-aided detection (CADe) systems for colonoscopy promise to reduce clinical miss rates, yet reliable real-world deployment remains elusive. This translational gap stems in part from a structural flaw in model development: the reliance on curated datasets that under-represent the long negative stretches and procedure-related artifacts characteristic of routine examinations. Training and evaluating architectures strictly on these lesion-centric benchmarks creates an illusion of success, since such benchmarks cannot capture clinically crucial metrics. To expose this gap, we establish TRUE-Colon, a standardized benchmarking protocol that measures key deployment characteristics alongside localization accuracy, and evaluate four real-time architectures (Faster R-CNN, YOLOv8, YOLOv11, RT-DETR) across curated benchmarks (SUN, PICCOLO) and 60 unedited, full-length procedures (REAL-Colon). We observe a consistent transfer asymmetry: models trained strictly on curated clips suffer a severe performance collapse when evaluated on full procedures, whereas procedure-trained models substantially improve rejection of non-polyp content on REAL-Colon, and largely retain their accuracy on curated benchmarks. Beyond transferability, we find that the Transformer detector attains the strongest sensitivity and the earliest, most persistent detections, while the convolutional detectors stay competitive at a higher throughput. Together, these results indicate that both training and benchmarking for deployable CADe should shift from curated, lesion-centric clips toward full-procedure data and deployment-relevant operating points. Source code is available at https://github.com/sdoerrich97/true-colon.

0.38

Accuracy Is Not Enough: An Efficiency- and Statistics-Aware Benchmark of ResNet50 and Vision Transformer for Explainable Multi-Class Gastrointestinal Diseases Classification

cs.CV ·2026-10-25 ·Akwasi Asare
benchmarkhot direction similarity 0.64
Abstract

Automated classification of gastrointestinal (GI) findings in endoscopic images could support early diagnosis, but architectures are often chosen on accuracy alone. We present a controlled, reproducible benchmark of ResNet50 and ViT-B/16 for eight-class GI classification on the public Kvasir dataset (4,000 images), using a stratified split (400 test images) and stratified group 5-fold cross-validation over all images. In cross-validation, ResNet50 and ViT-B/16 reached 92.12% and 91.70% accuracy, and a two one-sided tests (TOST) procedure showed equivalence within a +/-3 percentage-point margin (difference +0.43 points, 90% CI -0.33 to +1.18; p < 0.001). The architectures differed mainly in cost: ResNet50 had 3.6 times fewer parameters and 4.3 times fewer operations, 2.5-fold lower single-image CPU latency (69 vs. 177 ms) and 3.8-fold higher GPU throughput. Cross-validated calibration was similar (expected calibration error 0.021 vs. 0.023). An edge-oriented transformer, MobileViT-S, was most accurate on the test split (95.5%) but lost 9.4 points when an acquisition artefact present in some classes (the ScopeGuide inset) was occluded, whereas ResNet50 was not significantly affected. On 500 unseen polyp images with expert masks, both models' Grad-CAM maps focused on the lesion (3.6 times chance). On a de-duplicated external subset of GastroVision (1,998 images), accuracy fell to 78-80% for all three models and differences between them remained small. Accuracy differences between architectures were thus small relative to the effects of shortcut learning and domain shift, whereas efficiency differences were large. An efficient CNN is a defensible default for resource-constrained screening, but no model is deployment-ready without local validation.

0.29

Cross-dataset harmonization for robust endoscopic image analysis

cs.CV ·2026-10-05 ·Romil Imtiaz, Dimitris K. Iakovidis
similarity 0.64
Abstract

A significant problem in endoscopic image analysis is that the machine learning (ML) models used for this purpose usually underperform when applied on images acquired from endoscopes that are different from those used to acquire the images of their training set. The main difference of the images originating from different endoscopes is their color distributions, which depend both on the image sensors and the light sources used. Although previous studies have highlighted this challenge, to the best of our knowledge it has not been previously explicitly tackled. This study focuses on this problem and proposes very simple but impactful method. It implements a reference-based image harmonization that reduces global appearance differences between endoscopic datasets. Specifically, it extracts global color statistics from a chosen reference dataset in the CIE-Lab color space and applies a statistical channel-wise transformation to map each target image toward the appearance of the images of the reference dataset. The method is evaluated in the context of polyp detection in both flexible colonoscopy and capsule endoscopy datasets using a dataset-level cross validation protocol. The results indicate that the proposed harmonization consistently improves cross-dataset performance up to 30.7%, outperforming relevant baseline and state-of-the-art methods. The results indicate that a substantial part of the generalization gap is driven by low-level appearance variation that can be mitigated without retraining.

0.20

Attention Residual U-Net for Enhanced Cross-Dataset Polyp Localization in Endoscopy

cs.CV ·2026-11-02 ·Romil Imtiaz, Dimitris K. Iakovidis
similarity 0.62
Abstract

Precise localization of pathologies in endoscopy is a critical task in medical imaging, with deep learning (DL) frameworks now serving as the primary methodology for automated lesion detection. Today, generic object detection methods, such as YOLO, provide state-of-the-art performance in this context. However, their robustness often decreases under real-world clinical conditions due to variations across endoscopic devices, intestinal content, dataset bias, and the presence of small or low-contrast lesions. Motivated by these challenges, we propose a novel polyp detection framework based on a Attention Residual U-Net offering enhanced polyp localization. Instead of directly regressing bounding boxes from global feature representations, the proposed method learns lesion-focused spatial representations and converts them into bounding-box predictions during inference. Unlike conventional encoder-decoder localization frameworks that directly propagate all encoder activations into the decoding pathway, the proposed method selectively suppresses irrelevant background responses before feature reconstruction. This encourages the network to focus on lesion-relevant spatial evidence under heterogeneous imaging conditions. To achieve this, the framework integrates residual feature propagation, attention-guided encoder filtering, and multi-scale contextual learning. The proposed framework was evaluated on multiple public endoscopic datasets acquired using different devices. The comparative experimental results validate its effectiveness over the relevant state-of-the-art methods, with an improvement up to 22.0% in terms of the area under the receiving operating characteristic (AUC).

0.18

From Image Latent Space to Fuzzy Rules: Interpretable Analysis of Gastrointestinal Foundation Model

cs.CV ·2026-09-30 ·Michael D. Vasilakakis, Dimitris K. Iakovidis
top venue similarity 0.61
Abstract · Accepted at the excv, ECCV 2026 Workshops. 17 pages, 4 figures, 7 tables

Foundation models pretrained on large-scale datasets demonstrate strong transferability to medical imaging tasks. However, understanding how their latent representations encode clinically relevant information remains an open challenge in safety-critical domains. This study proposes a prototype-based fuzzy-rule framework that interprets the patch-level features produced by the inner layers of pretrained foundation models, without any fine-tuning. Class-specific prototypes are learned by clustering in the feature space, yielding compact visual patterns. Patch features are then expressed as prototype similarities and classified by fuzzy rules with linguistic IF-THEN conditions that are human readable. The framework is applied across the final two blocks of ViT-S/16 backbones pretrained on ImageNet-1K and GastroNet-5M, and benchmarked against k-nearest neighbours, kernel SVM, and linear probing under identical frozen features, on wireless capsule endoscopy classification, gastrointestinal endoscopy classification, and colonic polyp segmentation. The experimental analysis shows that the proposed method, without backbone fine-tuning, reaches accuracy comparable to these black-box classifiers, and that domain-specific pretraining yields features that are both discriminative and symbolically compressible. Because the resulting rules are extracted from real data and expressed in interpretable terms, they are further used as an instrument to investigate synthetic medical images, providing a human-readable account of which real prototypes and rules a generator reproduces or fails to reproduce, localising where a synthetic image departs from real tissue rather than summarising it with a single score. The framework thus offers a transparent, depth-resolved view of how foundation models organise clinically relevant structure, together with a practical downstream use of the extracted rules.

0.41

Rethinking Evaluation for Video Capsule Endoscopy: Validation Protocol, Source-Video Diversity, and Cross-Dataset Shift

cs.CV ·2026-11-09 ·Smriti Regmi, Debesh Jha
benchmark similarity 0.61
Abstract · 4 figures and 9 tables

Automated video capsule endoscopy (VCE) classification remains challenging due to severe class imbalance, limited source-video diversity, and variations in image appearance across datasets. Although deep learning models have demonstrated promising performance on established benchmarks, their reliability under different validation protocols and external dataset shift remains insufficiently understood. In this work, we introduce DMSNet, a deformable adaptive multi-scale edge-guided attention network integrating adaptive multi-scale feature fusion, deformable lesion refinement, edge-guided attention, and sparse feature selection. We benchmark DMSNet against 18 representative convolutional, transformer-based, and pretrained vision architectures on Kvasir-Capsule under random frame-level and source-video-disjoint validation protocols. We further identify source-video overlap between the original training and test splits and evaluate model performance on both the complete test set and a source-video-disjoint subset. Under random frame-level validation, DMSNet achieves an MCC of 0.442 $\pm$ 0.020 on complete test set and 0.456 $\pm$ 0.037 on the source-video-disjoint subset. On the external CV2024 dataset, ConvNeXt-Tiny achieves the highest MCC of 0.207, while performance degrades substantially across architectures relative to in-domain evaluation. We further investigate source-video diversity using a per-class cap of 200 training frames. With the total training-set size held fixed, increasing the maximum source-video coverage from four to eight improves MCC for 17 of 19 evaluated architectures. Overall, these findings demonstrate that model rankings and classification performance depend substantially on evaluation protocol, training-source diversity, and cross-dataset shift, emphasizing the need for source-aware validation and rigorous external evaluation of VCE classification systems.

0.22

Annotation-Free Representation Learning for Polyp Retrieval in Colonoscopy Videos

cs.CV ·2026-10-29 ·Luca Parolari, Lamberto Ballan, Carlo Biffi, Loic Le Folgoc
code/data similarity 0.60
Abstract · Under submission at ISBI 2027

Colonoscopy is inherently comparative: reliable visual assessment of polyps often depends on complementary views acquired under different viewpoints and imaging conditions. Retrieving such views requires polyp tracklet representations, which recent contrastive methods learn from temporal cues but still build from manually annotated bounding boxes. We propose an annotation-free framework that constructs tracklet views directly from raw colonoscopy videos, enabling temporal self-supervised learning on full-procedure videos, including frames without visible polyps. On REAL-Colon, our method achieves state-of-the-art results on tracklet retrieval and re-identification, outperforming both self-supervised and supervised baselines. We then introduce few-shot polyp retrieval, a task closer to clinical use, where a few observations of a target polyp are used to retrieve its remaining tracklets: with only two examples, our method surpasses most competing methods given ten. Finally, we show that a modest number of unlabeled procedures suffices for competitive performance, making on-site model development more practical. Code is available at https://github.com/lparolari/freerep.

0.28