CS Paper Radar

Cross-dataset harmonization for robust endoscopic image analysis

Romil Imtiaz, Dimitris K. Iakovidis

cs.CV ·submitted 2026-10-05 16:39 UTC · v1

Abstract

A significant problem in endoscopic image analysis is that the machine learning (ML) models used for this purpose usually underperform when applied on images acquired from endoscopes that are different from those used to acquire the images of their training set. The main difference of the images originating from different endoscopes is their color distributions, which depend both on the image sensors and the light sources used. Although previous studies have highlighted this challenge, to the best of our knowledge it has not been previously explicitly tackled. This study focuses on this problem and proposes very simple but impactful method. It implements a reference-based image harmonization that reduces global appearance differences between endoscopic datasets. Specifically, it extracts global color statistics from a chosen reference dataset in the CIE-Lab color space and applies a statistical channel-wise transformation to map each target image toward the appearance of the images of the reference dataset. The method is evaluated in the context of polyp detection in both flexible colonoscopy and capsule endoscopy datasets using a dataset-level cross validation protocol. The results indicate that the proposed harmonization consistently improves cross-dataset performance up to 30.7%, outperforming relevant baseline and state-of-the-art methods. The results indicate that a substantial part of the generalization gap is driven by low-level appearance variation that can be mitigated without retraining.

Closest papers

Nearest neighbours by meaning across the whole index.

Polyp Matching Using Deep Learning

cs.CV cs.AI ·2026-11-03 ·Kristian Dalsbø Hindberg, Puneet Sharma, Benedicte Schelde-Olesen, Ulrik Deding, Jakob Frederik Frøkjær Justsen +2 more
hot direction similarity 0.64
Abstract

A key challenge in colon capsule endoscopy (CCE) analysis is accurately identifying whether multiple images depict the same polyp, which is critical to avoid over-counting and unnecessary clinical interventions. Additionally, this prevents prolonged follow-up colonoscopies where endoscopists search for duplicate polyps without precise localization. This study presents a novel contrastive learning-based approach to polyp matching using a Siamese neural network architecture. The model was trained on a dataset from the Danish CareForColon2015 trial. The dataset comprises 5,103 image pairs of confirmed same polyp and 5,103 pairs of different polyps, annotated by experienced clinicians. The proposed model employs ResNet variants (ResNet18, ResNet34, ResNet50), DenseNet121 and EfficientNet B0/B3 as backbones and utilizes contrastive learning with cosine vector distance metric for classification. Experimental results demonstrate high classification accuracies of up to 92% and AUC values close to 0.98. These results suggest that automated polyp matching has the potential to reduce polyp over-counting, improve patient risk stratification, and reduce unnecessary follow-up colonoscopies.

0.30

Accuracy Is Not Enough: An Efficiency- and Statistics-Aware Benchmark of ResNet50 and Vision Transformer for Explainable Multi-Class Gastrointestinal Diseases Classification

cs.CV ·2026-10-25 ·Akwasi Asare
benchmarkhot direction similarity 0.64
Abstract

Automated classification of gastrointestinal (GI) findings in endoscopic images could support early diagnosis, but architectures are often chosen on accuracy alone. We present a controlled, reproducible benchmark of ResNet50 and ViT-B/16 for eight-class GI classification on the public Kvasir dataset (4,000 images), using a stratified split (400 test images) and stratified group 5-fold cross-validation over all images. In cross-validation, ResNet50 and ViT-B/16 reached 92.12% and 91.70% accuracy, and a two one-sided tests (TOST) procedure showed equivalence within a +/-3 percentage-point margin (difference +0.43 points, 90% CI -0.33 to +1.18; p < 0.001). The architectures differed mainly in cost: ResNet50 had 3.6 times fewer parameters and 4.3 times fewer operations, 2.5-fold lower single-image CPU latency (69 vs. 177 ms) and 3.8-fold higher GPU throughput. Cross-validated calibration was similar (expected calibration error 0.021 vs. 0.023). An edge-oriented transformer, MobileViT-S, was most accurate on the test split (95.5%) but lost 9.4 points when an acquisition artefact present in some classes (the ScopeGuide inset) was occluded, whereas ResNet50 was not significantly affected. On 500 unseen polyp images with expert masks, both models' Grad-CAM maps focused on the lesion (3.6 times chance). On a de-duplicated external subset of GastroVision (1,998 images), accuracy fell to 78-80% for all three models and differences between them remained small. Accuracy differences between architectures were thus small relative to the effects of shortcut learning and domain shift, whereas efficiency differences were large. An efficient CNN is a defensible default for resource-constrained screening, but no model is deployment-ready without local validation.

0.29

Endo-TSR: Temporal Spectral Modeling of Appearance and Motion for Endoscopic Reconstruction

cs.CV cs.RO ·2026-09-26 ·Taoyu Wu, Yiyi Miao, Qi Shao, Zhuoxiao Li, Zhe Tang +2 more
similarity 0.61
Abstract · 5 pages, 3 figures, 2 tables

Endoscopic scene reconstruction requires modeling tissue motion and temporal appearance while recovering fine surface detail. Deformable Gaussian models provide explicit trajectories, but their fixed colour coefficients lack a dedicated temporal representation for photometric changes. We propose Endo-TSR, which augments deformable Gaussian splatting with bounded Fourier colour residuals and independent translation residuals on shared temporal frequencies. The colour residuals capture local appearance changes, while a Matérn spectral prior regularises motion corrections. Multi-scale Laplacian supervision guides tissue-detail recovery during joint image fitting. Extensive experiments on the EndoNeRF and StereoMIS datasets demonstrate state-of-the-art rendering quality, with the highest PSNR across all evaluated sequences. Ablation studies show that temporal appearance yields the largest PSNR gain among the tested component additions, while appearance and detail supervision jointly improve rendering with fixed Gaussian counts.

0.24

From Generalist to Specialist: A Context-Fusion Framework for Endoscopic Polyp Reporting with a Frozen VLM

cs.AI cs.CV ·2026-08-16 ·Ruijie Yang, Yan Zhu, Peiyao Fu, Siyuan Li, Te Luo +5 more
similarity 0.61
Abstract

Reliable endoscopic polyp reporting requires integrating quantitative lesion sizing, standardized Paris classification, and clinically meaningful morphological description within a single record. General-purpose vision-language models (VLMs) offer a unified interface for image understanding and report generation. Existing specialization strategies, however, typically rely on task-specific models or model-weight adaptation, leaving unresolved how to introduce reliable specialist knowledge while preserving both this unified interface and the VLM's pretrained capabilities. We introduce a context-fusion framework that specializes a frozen general-purpose VLM through both implicit instruction context and explicit transduction context without modifying its pretrained weights. Specifically, a self-supervised polyp encoder retrieves related image-report pairs as explicit, query-specific evidence, while learned continuous specialist tokens provide implicit instruction context shared across cases. Experiments were conducted on 2,056 expert-annotated public endoscopic images. We compared the framework with general-purpose VLMs, task-specific predictors, and weight-adaptation methods to assess specialist performance, unified reporting, and adaptation efficiency. Across numerical, categorical, and report-generation metrics, the proposed framework substantially improved direct frozen-VLM inference and achieved the strongest overall performance among the evaluated methods. It added trainable parameters equal to only 0.006% of the frozen VLM's parameter count. When the top-1 retrieved case carried the correct target category, our framework corrected 70.5% of the errors made by a weight-adaptation baseline. These findings support the context-fusion framework as a lightweight and effective strategy for specialist adaptation of a frozen VLM.

0.04

CSG-Mamba: A Convolutional Scoring Gating Vision State Space Network for Endoscopic Polyp Segmentation

cs.CV ·2026-08-14 ·Yuliang Wang, Jiaqi Wu, Jiaye Song, Shuxia Ren
published similarity 0.61
Abstract · 14 pages, 6 figures, and 5 tables. Accepted by ICONIP 2026

Accurate polyp segmentation is critical for computer-aided colonoscopy, yet endoscopic images often contain low-contrast boundaries, mucosal texture interference, specular highlights, and device-dependent appearance shifts. Vision State Space Models (SSMs) provide efficient long-range modeling with linear complexity, but existing Vision Mamba segmentation models typically convert 2D features into 1D scanning sequences, which may weaken local geometric continuity and over-smooth irregular contours. We propose CSG-Mamba, a convolutional scoring gating Vision State Space network for endoscopic polyp segmentation. Built on a VM-UNet-style asymmetric U-shaped encoder-decoder, CSG-Mamba inserts a Convolutional Scoring Gating (CSG) module at the semantically rich bottleneck. CSG generates a local spatial score map through pointwise and large-kernel depthwise convolutions and recalibrates state-space features by multiplicative gating. Experiments with three random seeds show that CSG-Mamba achieves 0.9220 Dice and 15.87 HD95 on Kvasir-SEG, and 0.7418 Dice and 0.6570 mIoU on CVC-ColonDB, outperforming the baselines on most overlap and recall metrics while maintaining competitive boundary accuracy.

0.28

Polyp-VSSD: A Pre-trained Transformer with Local-Global Joint VSSD Decoding for Polyp Segmentation

cs.CV ·2026-10-23 ·Xiaobo Zhu, Shiwei Wu, Yu An, Yuechen Tao, He Sun +2 more
similarity 0.60
Abstract

Early detection of colorectal polyps is essential for preventing colorectal cancer, making accurate polyp segmentation a key component in computer-aided diagnosis systems. However, existing endoscopic segmentation methods often exhibit limited representational capacity and insufficient integration of global and local contextual information. To address these limitations, we propose Polyp-VSSD, a novel local-global joint decoding framework built upon a pre-trained Transformer backbone for high-precision polyp segmentation. Polyp-VSSD leverages the strong feature expressiveness of large-scale visual pre-training and unifies global semantic modeling with local fine-grained reconstruction to enhance segmentation fidelity. Extensive experiments on multiple public endoscopic datasets demonstrate that our approach significantly outperforms state-of-the-art methods in both Dice and IoU. On the EndoScene dataset, Polyp-VSSD achieves mIoU and mDice scores of 0.903 and 0.946, respectively, highlighting its robustness and strong generalization capability. This work presents an effective and scalable solution for intelligent endoscopic image analysis.

0.25

From Image Latent Space to Fuzzy Rules: Interpretable Analysis of Gastrointestinal Foundation Model

cs.CV ·2026-09-30 ·Michael D. Vasilakakis, Dimitris K. Iakovidis
top venue similarity 0.60
Abstract · Accepted at the excv, ECCV 2026 Workshops. 17 pages, 4 figures, 7 tables

Foundation models pretrained on large-scale datasets demonstrate strong transferability to medical imaging tasks. However, understanding how their latent representations encode clinically relevant information remains an open challenge in safety-critical domains. This study proposes a prototype-based fuzzy-rule framework that interprets the patch-level features produced by the inner layers of pretrained foundation models, without any fine-tuning. Class-specific prototypes are learned by clustering in the feature space, yielding compact visual patterns. Patch features are then expressed as prototype similarities and classified by fuzzy rules with linguistic IF-THEN conditions that are human readable. The framework is applied across the final two blocks of ViT-S/16 backbones pretrained on ImageNet-1K and GastroNet-5M, and benchmarked against k-nearest neighbours, kernel SVM, and linear probing under identical frozen features, on wireless capsule endoscopy classification, gastrointestinal endoscopy classification, and colonic polyp segmentation. The experimental analysis shows that the proposed method, without backbone fine-tuning, reaches accuracy comparable to these black-box classifiers, and that domain-specific pretraining yields features that are both discriminative and symbolically compressible. Because the resulting rules are extracted from real data and expressed in interpretable terms, they are further used as an instrument to investigate synthetic medical images, providing a human-readable account of which real prototypes and rules a generator reproduces or fails to reproduce, localising where a synthetic image departs from real tissue rather than summarising it with a single score. The framework thus offers a transparent, depth-resolved view of how foundation models organise clinically relevant structure, together with a practical downstream use of the extracted rules.

0.41

On the Robustness of Temporal Vision-Language Models for Surgical Endoscopy Videos

cs.CV ·2026-08-14 ·Darakshan Rashid, Raza Imam, Ufaq Khan, Muhammad Bilal, Shazad Ashraf +7 more
top venuebenchmark similarity 0.58
Abstract · Accepted to MICCAI 2026

Temporal vision-language models (TVLMs) offer a reusable, prompt-based interface for surgical video understanding, yet, their robustness under clinically realistic acquisition artifacts in endoscopy remains insufficiently characterized. In practice, degradations such as defocus, haze, motion blur, noise, cautery smoke, and packet loss introduce structured distribution shifts which may compromise video-text alignment. We study the robustness of temporal VLMs under such shifts caused by corruptions in clip frames. We introduce Endo-C6, a compact corruption benchmark of six endoscopy-realistic perturbations evaluated at a fixed high severity, and apply it to public Gastrointestinal (GI) endoscopy and laparoscopic cholecystectomy videos. Under a standardized prompt protocol, we benchmark 3 recent surgical TVLM baselines and analyze robustness in both mean and worst-case settings, spanning 294 dataset-level evaluations. Finally, we present RobustEndoCLIP, obtained by few-shot parameter-efficient tuning with VeRA, outperforming existing TVLM baselines. Our findings show that off-the-shelf TVLMs can exhibit severe worst-case collapse under endoscopy-specific corruptions, whereas lightweight few-shot adaptation can substantially improve corrupted performance and robustness without changing the prompt-based interface. We expect Endo-C6 to support standardized robustness reporting and promote more reliable clinical vision-language systems.

0.29