CS Paper Radar

GENCO - A Unified Neural Solver Embedded in a Development Framework for Steady-State Grid Analysis

Alban Puech, Matteo Mazzonelli, Tamara R. Govindasamy, Mangaliso Mngomezulu, Héctor Maeso-García, Thomas Tolhurst, Javad Bayazi, Ali Moeini, Naomi Simumba, Celia Cintas, David Nelischer, Romeo Kienzler, Jonas Weiss, Anna Varbella, Florian Dörfler, Gabriela Hug, Martin Mevissen, Juan Bernabé-Moreno, François Mirallès, Hendrik F. Hamann, Etienne Vos, Thomas Brunschwiler

cs.AI ·submitted 2026-08-10 17:57 UTC · v3
code/datahighly cited

Abstract

Foundation models are transforming business workflows and boosting productivity, yet they remain largely absent from engineering domains such as power system analysis, where strict physical consistency must be enforced. We present GENCO (GEometric Neural Corrective Optimizer), a unified neural solver for steady-state transmission grid analysis that handles power flow (PF), optimal power flow (OPF), and state estimation (SE) within a single architecture and shared grid representation. To support advances in neural power system solvers, we introduce the open-source GridFM Development Framework, which standardizes synthetic data generation and training in a low-code environment. We also release large-scale datasets with millions of PF and OPF scenarios across diverse grid topologies to support reproducible benchmarking. We evaluate GENCO on the PFDelta and OPFData benchmarks against state-of-the-art neural solvers and classical solvers, including Newton-Raphson and IPOPT, as well as on real-world Hydro-Québec SCADA data. For large-scale PF, GENCO recovers the full AC operating state, including voltage magnitudes and reactive power that DC-PF cannot provide, while matching DC-PF-level active power-balance residuals. It achieves up to 30x speedups over Newton-Raphson at only 2x the runtime of DC-PF. For OPF, it achieves up to 85x speedups over IPOPT while improving feasibility, optimality, and runtime over DC-OPF. For SE, GENCO is more robust than classical weighted least squares to noisy measurements and grid parameter errors, and always returns a high-quality estimate even when weighted least squares fails to converge. Together, the unified architecture and development framework provide a new approach to large-scale steady-state grid analysis, lowering the barrier to entry for power system engineers and marking a step toward Grid Foundation Models.

Closest papers

Nearest neighbours by meaning across the whole index.

Learning by Examples: Power Grid Steady State Analysis with a Tabular Foundation Model

cs.LG ·2026-10-14 ·Olayiwola Arowolo, Oluwadara Adedeji, Peter Palensky, Jochen L. Cremer
similarity 0.71
Abstract · 12 pages, 8 figures, under review

Foundation models have shown strong generalization across scientific domains, but their use in power systems remains largely task-specific. We investigate whether a pretrained tabular foundation model (TFM), TabPFN, can serve as a general-purpose neural solver for power grid steady-state analysis. We evaluate the TFM on three tasks: power flow (PF) prediction, N-k contingency screening (NCS), and voltage stability margin (VSM) prediction. We performed experiments on 118- and 2000-bus systems, comparing the TFM against task-specific neural baselines. Without retraining or fine-tuning, the TFM matches or outperforms the best task-specific model in several settings across the three tasks. For 118-bus PF prediction, a variant of the TFM achieves errors of $1\times 10^{-3}$ pu for voltage magnitudes and $0.30^\circ$ for voltage angles, outperforming all baselines. On unseen N-1 contingency and close-to-infeasible PF cases, the TFM is competitive with the DCPF approximation. For millions of unseen N-2 contingencies, the TFM achieves AUCs of 0.92 and 0.95 for branch and voltage violation screening, respectively. The TFM also attains accurate VSM prediction performance for the 2000-bus system with limited labelled data. The TFM attains strong results across the tested tasks despite pretraining without any power-system-specific dataset and requiring no fine-tuning step. These results offer a glimpse into the potential of pretrained TFMs as a neural solver for a range of power grid analysis tasks.

0.15

GridSFM: A Foundation Model for Solving AC Optimal Power Flow

eess.SY cs.LGmath.OC ·2026-09-24 ·Luke Bhan, Weiwei Yang, Margaret Capetz, Baosen Zhang
theoryhighly cited similarity 0.69
Abstract · 19 pages

We introduce GridSFM, a framework that combines a pretrained foundation model across grid topologies with physics-informed fine-tuning for solving AC Optimal Power Flow (AC-OPF) at scale. It is a $15$ million parameter physics-inspired graph neural network pretrained across $54$ topologies of $500$ to $4{,}000$ buses. Our model attains a $2.45\%$ zero-shot generation-cost error on a $10{,}000$ bus case held-out operating conditions with no degradation as system size grows. Building on this, we pair the pretrained backbone with a physics-informed fine-tuning design based on Newton's method for power flow. With only $100$ solved instances, GridSFM adapts to unseen grids up to $10{,}000$ buses. We show it out performs single topology, dedicated neural network models that are trained more data, both in terms of cost and solver iterations when deployed as warm starting points. In designing this foundation model, we overcome the fact that the feasible set for AC-OPF can be disconnected. This is an obstruction that prevents any continuous neural network from approximating the solution map. To do so, we lift the problem and relax its constraints with logarithmically penalized slacks. We prove that the resulting elastic feasible set is contractible, that the AC-OPF minimizers remain minimizers of the elastic problem above an explicit penalty threshold, and that projecting an approximate solution back onto the AC-OPF feasible set is well posed. We release all models, data, and code so that the community can build on a shared starting point for AC-OPF.

0.41

Benchmarking a Grid Foundation Model for AC Optimal Power Flow: Feasibility and Warm-Start Results on Synthetic Texas and South Carolina Grids

eess.SY ·2026-11-17 ·Tam Kemabonta, Brighton Ombuki, Vladimir Abdelnour
similarity 0.68
Abstract · 5 pages, 3 figures, 2 tables. Submitted to the 2027 IEEE PES General Meeting

Learning-based surrogates for alternating-current optimal power flow (AC-OPF) are often judged by the gap between their objective value and that of a nonlinear solver, which does not show that a prediction satisfies power balance and network limits. This paper tests whether predictions from the pretrained foundation model GridSFM-Open 1.1.0, recently released by Microsoft, are feasible AC-OPF operating points and whether they are useful initial values for a nonlinear solver. The model was evaluated zero-shot and after fine-tuning on 10, 100, and 1,000 labeled scenarios (FT10, FT100, and FT1000) on 500 scenarios for each of two synthetic grids, ACTIVSg2000 (Texas) and ACTIVSg500 (South Carolina), with Ipopt, MATPOWER MIPS, and pandapower PIPS as solver references. The lowest Texas median cost gap, 0.44\% for FT100, coincided with thermal violations in 24.1\% of cases and a median maximum bus power mismatch of 89 MW and 197 Mvar. Texas zero-shot predictions had a median maximum mismatch of 648 MW and 1,641 Mvar, and every South Carolina case violated a thermal limit for every model variant. Seeding Ipopt with FT1000 predictions gave geometric-mean solve-time speedups of 1.55x on South Carolina and 1.12x on Texas (p = 0.06, not significant at the 5\% level), while zero-shot seeds slowed South Carolina solves (0.26x). A small objective gap therefore did not indicate feasibility: although median zero-shot inference took only 1.32 s on Texas and 0.157 s on South Carolina on a shared host, every prediction still required a nonlinear solver, and fine-tuned predictions gave modest, grid-dependent warm-start speedups while zero-shot predictions slowed convergence on one grid. GridSFM may therefore be useful for initializing a nonlinear solver, but obtaining feasible AC-OPF solutions still required the solver.

0.32

Extending Grid Foundation Models for Phasor-Domain Dynamic Simulation

eess.SY cs.LG ·2026-11-06 ·Boyang Zhao, Yifan Zhou, Alban Puech, Tilman Bockhacker, Hendrik Hamann
similarity 0.67
Abstract

Grid Foundation Models (GridFMs) are emerging as a powerful framework for learning and transferring knowledge across power grids and grid analysis tasks. This work extends GridFMs from steady-state analysis to dynamic simulation. We present DynGridFM, which uses component-wise tokenization and a structured latent operator to learn shared dynamic representations across heterogeneous grids and enable transfer to unseen systems. Pretrained on nine grids, DynGridFM is adapted to a held-out 48-machine grid, where fine-tuning on 64 trajectories achieves accuracy comparable to training from scratch on 128. On a single GPU, it achieves 924x to 1232x speedup over numerical simulators on one CPU core.

0.26

Unified Heterogeneous Graph Neural Network solver for Power Flow, Optimal Power Flow and State Estimation

eess.SY cs.LG ·2026-09-15 ·Ferran Bohigas-Daranas, Hamid Latif-Martínez, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt, Pere Barlet-Ros
similarity 0.67
Abstract

Power Flow (PF), Optimal Power Flow (OPF), and State Estimation (SE) are fundamental problems in power system analysis, but solving them is computationally expensive. Graph Neural Networks (GNNs) have been proposed as fast surrogates, yet existing solvers are trained for a single problem at a time, producing narrow models that must be rebuilt for each new task. We propose a more general approach: a single Heterogeneous Residual Gated Graph Convolutional Network that solves all three problems with one shared backbone. Rather than learning one mapping, the model learns a reusable representation of how the network behaves, from which PF, OPF, and SE can each be estimated. Trained jointly on the three problems across diverse topologies and loading conditions, and evaluated on the IEEE 14-bus and 118-bus systems, the shared model matches the accuracy of task-specific GNN solvers and stays robust on unseen loading levels and topologies. These results show that a single model can capture the basic operation of a power network and serve several analysis tasks at once, a first step toward a foundation model for power systems.

0.11

Physics-Informed but Not Physics-Consistent: Error Geometry and Subspace Projection for Neural AC Power Flow

cs.LG cs.AI ·2026-10-05 ·Changhun Kim, Timon Conrad, Redwanul Karim, Karan Pahlajani, Julian Oelhaf +5 more
code/data similarity 0.67
Abstract · ICASSP 2027 submitted; 3 figures, 3 tables. Code: https://github.com/Kimchangheon/neural-acpf-error-geometry

Recent neural power-flow solvers, including emerging foundation models, achieve accurate voltage predictions, yet such accuracy does not necessarily imply physically consistent solutions. Even small complex voltage errors can yield large AC power-balance residuals. We study this accuracy-consistency gap across PIGNN-GC, GridSFM, gridfm-graphkit, and LUMINA on realistic 2224-bus Great Britain network (GBnetwork) scenarios, with cross-grid evaluation of GridSFM over 31 systems. Using a singular value decomposition (SVD) basis fitted to training AC power-flow solutions, we find that neural prediction errors contain substantial components outside the dominant solution subspace. To address this mismatch, calibrated solution-subspace projection (CSP) suppresses off-subspace prediction components after train-only bias calibration, reducing Mean PB by 67.0%, 37.8%, 40.5%, and 68.9% for PIGNN-GC, GridSFM, gridfm-graphkit, and LUMINA, respectively, relative to calibrated predictions, while improving voltage-magnitude accuracy in all four models. These results identify output-error geometry as an important factor in physics-consistent neural AC power flow. Code: https://github.com/Kimchangheon/neural-acpf-error-geometry

0.34

AC Power Flow Contingency Analysis Using a Single Deep Neural Network

eess.SY cs.LG ·2026-09-25 ·Md Obaidur Rahman, Junjie Qin, Vassilis Kekatos
similarity 0.66
Abstract · 10 pages, 5 figures

Contingency analysis using the AC power flow (AC-PF) model is a critical tool for accurate grid security assessment, but its computational burden increases with the number of operating scenarios and outage configurations to evaluate. Recent ML-based approaches typically require outage-specific training data, leading to offline training costs that scale with the number of contingencies. This work proposes a framework that reuses a single ML model trained solely on basecase AC-PF data to estimate post-contingency operating states under arbitrary single-line outages. The proposed approach formulates post-contingency state prediction as a fixed-point iteration. If the ML model is a deep neural network (DNN), we derive sufficient conditions that guarantee convergence and develop semidefinite programming (SDP) formulations to certify these conditions for a given DNN. Numerical tests on the IEEE 118-bus system demonstrate that the proposed SDP formulations are tight, that the certified conditions hold for all tested contingencies, and that the resulting method produces accurate post-contingency state estimates within only a few iterations.

0.45

Integrating Agentic Artificial Intelligence with High-Performance Computing for Grid Planning

eess.SY ·2026-09-03 ·Samim Konjicija, Slaven Peles
published similarity 0.65
Abstract · 6 pages, 3 figures, 3 tables. To appear in proceedings of EnergyCon 2026

We present AgentiGrid, an agentic artificial intelligence (AI) framework that integrates large language models (LLMs) intelligence and high-performance computing (HPC) to streamline and accelerate the multi-scenario power flow studies. AgentiGrid is an autonomous decision-making agent that proposes parameter modifications, invokes analyses through HPC analysis toolkit ExaGO, interprets results, and determines subsequent actions. ExaGO provides multiple power flow applications that can perform deterministic, stochastic and security constrained optimal power flow analyses. AgentiGrid provides backends to multiple LLMs (OpenAI, Anthropic, Ollama, and Ollama cloud) augmented with context specific and task specific prompts. Key features include interactive mid-search steering, goal-type-aware post-search analysis, and concurrent variant exploration for power flow optimization. A Streamlit-based graphical launcher provides real-time visualization of iteration progress and generates reports in natural language. AgentiGrid is capable of autonomously converging transmission constrained alternating current optimal power flow in under 20 iterations, with near-perfect reliability

0.44