Contingency analysis using the AC power flow (AC-PF) model is a critical tool for accurate grid security assessment, but its computational burden increases with the number of operating scenarios and outage configurations to evaluate. Recent ML-based approaches typically require outage-specific training data, leading to offline training costs that scale with the number of contingencies. This work proposes a framework that reuses a single ML model trained solely on basecase AC-PF data to estimate post-contingency operating states under arbitrary single-line outages. The proposed approach formulates post-contingency state prediction as a fixed-point iteration. If the ML model is a deep neural network (DNN), we derive sufficient conditions that guarantee convergence and develop semidefinite programming (SDP) formulations to certify these conditions for a given DNN. Numerical tests on the IEEE 118-bus system demonstrate that the proposed SDP formulations are tight, that the certified conditions hold for all tested contingencies, and that the resulting method produces accurate post-contingency state estimates within only a few iterations.

Comment
10 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Expediting AC Contingency Analysis using a Basecase Machine Learning Model

eess.SY ·2026-09-29 ·Md Obaidur Rahman, Vassilis Kekatos
similarity 0.78
Abstract · 10 page, 7 figures

Grid planning and operation under increasingly variable operating conditions require fast and accurate AC power flow (AC-PF) contingency analysis for numerous line outages. While ML models can accelerate these computations, existing approaches often require either training separate models for different contingencies or a single model using data from multiple topologies. Both approaches incur substantial offline data generation and training costs. To address this gap, this work proposes a fixed-point framework that reuses a single ML model trained exclusively on basecase topology data to predict post-contingency AC-PF states under any non-critical single-line outage. We analyze the proposed method's convergence under the DC model approximation and derive its convergence rate in terms of network parameters. As a side result, we show that power transfer distribution factors (PTDFs) for non-critical lines have magnitudes less than one. We further characterize the ML training region to accommodate PF specifications encountered during fixed-point iterations and derive bounds on ML prediction errors for post-contingency state estimates. Numerical tests on a 6,717-bus synthetic Texas system demonstrate convergence across all non-critical single-line outages, with prediction errors remaining close to those of basecase. The proposed framework offers a favorable tradeoff between the speed of DC solvers and Newton-Raphson accuracy.

0.11

Beyond Accuracy: Physics-Informed Evaluation of ANN-based Power Flow Solvers under System Shift

eess.SY ·2026-11-10 ·Dong Liu, Jochen Stiasny, Jochen Cremer, Pedro P. Vergara
similarity 0.69
Abstract

Recent advances in artificial deep learning-based power flow (PF) solvers have primarily focused on improving estimation accuracy, while their physical feasibility and operational reliability under realistic system variations remain insufficiently evaluated. This paper proposes a physics-informed evaluation framework for deep learning-based PF solvers under topology and load distribution shifts. Beyond conventional voltage-domain errors, the framework incorporates KCL gaps, branch-flow gaps, KVL residuals, continuous feasibility scores, and strict, practical, and relaxed PF feasibility rates. Four case studies are designed to investigate topology shifts, mixed topology training, load distribution shifts, and combined topology distribution shifts. Eight ANN architectures, including graph input models, load-only baselines, and physics-informed neural networks, are evaluated under consistent settings. The results demonstrate that low estimation errors do not necessarily correspond to physically feasible or operationally reliable PF solutions, particularly under combined system shifts. The proposed framework establishes an initial foundation and analysis for the development and verification of trustworthy deep learning-based PF solvers, providing support for their reliable deployment in future AI-enabled power system analysis.

0.09

PhyPro-FM: A Physics and Prompt-Guided Graph Foundation Model for Contingency Analysis

eess.SY cs.AIcs.LG ·2026-10-19 ·Xu Yang, Zhanyuan Sheng, Chenhui Lin, Haotian Liu, Qi Wang +2 more
similarity 0.68
Abstract

The continuous evolution of next-generation power systems, characterized by the high penetration of renewable energy resources and dynamic topology variations, poses formidable challenges to traditional N-1/N-2 contingency analysis in terms of computational efficiency and scalability. While deep learning-based methods offer accelerated inference, existing studies predominantly treat contingency analysis as a pure regression problem, often overlooking the physical essence of grid operation and engineering requirements of real-world scenarios. To bridge this gap, this paper proposes a physics and prompt-guided graph foundation model (PhyPro-FM) for generalizable and engineering-viable contingency analysis. The proposed architecture integrates graph neural networks with a learnable global query mechanism and, notably, introduces a prompt-guided learning paradigm. By leveraging historical snapshots as few-shot prompts, the model dynamically captures correlations between target and historical operating conditions, significantly enhancing generalization capabilities under unseen topologies. Furthermore, we design a physics-informed training mechanism that prioritizes branch power flow errors over nodal voltage errors, aligning the optimization objective with critical grid security constraints. To ensure engineering applicability, a physics-informed inference mechanism is also developed, incorporating a residual-based correction module and a specialized post-processing strategy for singular branches to circumvent numerical instability. Comprehensive experiments demonstrate that PhyPro-FM outperforms state-of-the-art methods in accuracy and generalization, validating its superior physical consistency and robustness for practical engineering applications.

0.18

Unified Heterogeneous Graph Neural Network solver for Power Flow, Optimal Power Flow and State Estimation

eess.SY cs.LG ·2026-09-15 ·Ferran Bohigas-Daranas, Hamid Latif-Martínez, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt, Pere Barlet-Ros
similarity 0.68
Abstract

Power Flow (PF), Optimal Power Flow (OPF), and State Estimation (SE) are fundamental problems in power system analysis, but solving them is computationally expensive. Graph Neural Networks (GNNs) have been proposed as fast surrogates, yet existing solvers are trained for a single problem at a time, producing narrow models that must be rebuilt for each new task. We propose a more general approach: a single Heterogeneous Residual Gated Graph Convolutional Network that solves all three problems with one shared backbone. Rather than learning one mapping, the model learns a reusable representation of how the network behaves, from which PF, OPF, and SE can each be estimated. Trained jointly on the three problems across diverse topologies and loading conditions, and evaluated on the IEEE 14-bus and 118-bus systems, the shared model matches the accuracy of task-specific GNN solvers and stays robust on unseen loading levels and topologies. These results show that a single model can capture the basic operation of a power network and serve several analysis tasks at once, a first step toward a foundation model for power systems.

0.11

GENCO - A Unified Neural Solver Embedded in a Development Framework for Steady-State Grid Analysis

cs.AI ·2026-08-10 ·Alban Puech, Matteo Mazzonelli, Tamara R. Govindasamy, Mangaliso Mngomezulu, Héctor Maeso-García +17 more
code/datahighly cited similarity 0.66
Abstract

Foundation models are transforming business workflows and boosting productivity, yet they remain largely absent from engineering domains such as power system analysis, where strict physical consistency must be enforced. We present GENCO (GEometric Neural Corrective Optimizer), a unified neural solver for steady-state transmission grid analysis that handles power flow (PF), optimal power flow (OPF), and state estimation (SE) within a single architecture and shared grid representation. To support advances in neural power system solvers, we introduce the open-source GridFM Development Framework, which standardizes synthetic data generation and training in a low-code environment. We also release large-scale datasets with millions of PF and OPF scenarios across diverse grid topologies to support reproducible benchmarking. We evaluate GENCO on the PFDelta and OPFData benchmarks against state-of-the-art neural solvers and classical solvers, including Newton-Raphson and IPOPT, as well as on real-world Hydro-Québec SCADA data. For large-scale PF, GENCO recovers the full AC operating state, including voltage magnitudes and reactive power that DC-PF cannot provide, while matching DC-PF-level active power-balance residuals. It achieves up to 30x speedups over Newton-Raphson at only 2x the runtime of DC-PF. For OPF, it achieves up to 85x speedups over IPOPT while improving feasibility, optimality, and runtime over DC-OPF. For SE, GENCO is more robust than classical weighted least squares to noisy measurements and grid parameter errors, and always returns a high-quality estimate even when weighted least squares fails to converge. Together, the unified architecture and development framework provide a new approach to large-scale steady-state grid analysis, lowering the barrier to entry for power system engineers and marking a step toward Grid Foundation Models.

0.60

Learning by Examples: Power Grid Steady State Analysis with a Tabular Foundation Model

cs.LG ·2026-10-14 ·Olayiwola Arowolo, Oluwadara Adedeji, Peter Palensky, Jochen L. Cremer
similarity 0.66
Abstract · 12 pages, 8 figures, under review

Foundation models have shown strong generalization across scientific domains, but their use in power systems remains largely task-specific. We investigate whether a pretrained tabular foundation model (TFM), TabPFN, can serve as a general-purpose neural solver for power grid steady-state analysis. We evaluate the TFM on three tasks: power flow (PF) prediction, N-k contingency screening (NCS), and voltage stability margin (VSM) prediction. We performed experiments on 118- and 2000-bus systems, comparing the TFM against task-specific neural baselines. Without retraining or fine-tuning, the TFM matches or outperforms the best task-specific model in several settings across the three tasks. For 118-bus PF prediction, a variant of the TFM achieves errors of $1\times 10^{-3}$ pu for voltage magnitudes and $0.30^\circ$ for voltage angles, outperforming all baselines. On unseen N-1 contingency and close-to-infeasible PF cases, the TFM is competitive with the DCPF approximation. For millions of unseen N-2 contingencies, the TFM achieves AUCs of 0.92 and 0.95 for branch and voltage violation screening, respectively. The TFM also attains accurate VSM prediction performance for the 2000-bus system with limited labelled data. The TFM attains strong results across the tested tasks despite pretraining without any power-system-specific dataset and requiring no fine-tuning step. These results offer a glimpse into the potential of pretrained TFMs as a neural solver for a range of power grid analysis tasks.

0.15

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

eess.SY cs.LG ·2026-09-23 ·Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann Jäger +1 more
benchmarkcode/data similarity 0.65
Abstract · 15 pages, 3 figures. Supplementary information included. Code: https://github.com/EvEMTBench/evemtbench-benchmark

Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.

0.22

Severity-Aware Minimum Security Sets for Accelerated Preventive SCOPF Using Machine Learning

eess.SY ·2026-10-14 ·Mohammad Iman Alizadeh, Saeed Zeynali, Salah Ghamizi, Sylvain Kubler
similarity 0.65
Abstract

This paper proposes a severity-aware machine learning framework for reducing the computational burden of preventive AC security-constrained optimal power flow (PSCOPF). The central idea is to identify a compact minimum security set (MSS) containing only the non-dominated contingencies and associated post-contingency constraints that materially influence the preventive operating point while satisfying a prescribed severity tolerance. An offline procedure combines AC security assessment, severity-based ranking, non-dominated screening, and iterative reduced PSCOPF. After each reduced PSCOPF solution, exhaustive security assessment over all credible contingencies identifies additional contingency--constraint pairs whose residual severity exceeds the specified threshold. Severity is characterized using the normalized number, accumulated magnitude, maximum magnitude, and average magnitude of post-contingency violations. The resulting operating-point-dependent MSSs are used as labels for a supervised multi-label learning model that predicts the security elements required to construct the reduced PSCOPF directly from the pre-contingency state. The proposed framework therefore focuses the optimization on the contingencies and constraints that affect preventive control decisions, reducing problem size and computation time while explicitly controlling residual post-contingency severity. Results on the IEEE 60-bus and 118-bus systems, the latter having an approximately seven-times-larger PSCOPF formulation, demonstrate substantial computational reductions with limited impact on the preventive operating solution.