CS Paper Radar

Severity-Aware Minimum Security Sets for Accelerated Preventive SCOPF Using Machine Learning

Mohammad Iman Alizadeh, Saeed Zeynali, Salah Ghamizi, Sylvain Kubler

eess.SY ·submitted 2026-10-14 08:07 UTC · v1

Abstract

This paper proposes a severity-aware machine learning framework for reducing the computational burden of preventive AC security-constrained optimal power flow (PSCOPF). The central idea is to identify a compact minimum security set (MSS) containing only the non-dominated contingencies and associated post-contingency constraints that materially influence the preventive operating point while satisfying a prescribed severity tolerance. An offline procedure combines AC security assessment, severity-based ranking, non-dominated screening, and iterative reduced PSCOPF. After each reduced PSCOPF solution, exhaustive security assessment over all credible contingencies identifies additional contingency--constraint pairs whose residual severity exceeds the specified threshold. Severity is characterized using the normalized number, accumulated magnitude, maximum magnitude, and average magnitude of post-contingency violations. The resulting operating-point-dependent MSSs are used as labels for a supervised multi-label learning model that predicts the security elements required to construct the reduced PSCOPF directly from the pre-contingency state. The proposed framework therefore focuses the optimization on the contingencies and constraints that affect preventive control decisions, reducing problem size and computation time while explicitly controlling residual post-contingency severity. Results on the IEEE 60-bus and 118-bus systems, the latter having an approximately seven-times-larger PSCOPF formulation, demonstrate substantial computational reductions with limited impact on the preventive operating solution.

Closest papers

Nearest neighbours by meaning across the whole index.

A Defense-Aware Explainable AI Framework for Feature-Level Vulnerability Analysis in Optimal Power Flow

cs.CR ·2026-10-28 ·S. M. Monzurul Hoque Chowdhury, Qinghua Li, Jianhui Wang
similarity 0.70
Abstract

Optimal power flow (OPF) is a foundational analysis in power system operation, and inaccuracies in OPF decision-making can result in significant operational and security consequences. With the increasing adoption of machine-learning-based OPF surrogate models for real-time and large-scale applications, power system operation has become more susceptible to cyber threats, including data manipulation and false data injection attacks. Explainable artificial intelligence (XAI), particularly Shapley value-based approaches, has been employed to quantify the influence of input features on OPF outputs. Features exhibiting high influence are commonly interpreted as vulnerable. However, this interpretation neglects the role of attack detection mechanisms in the system, which typically monitor input-to-input relationships to detect anomalous behavior. Consequently, highly influential features may be readily detectable and may not represent the most vulnerable attack surfaces. To address this limitation, we propose a defense-aware explainable AI framework that explicitly incorporates attack detectability alongside operational impact. The framework integrates an OPF surrogate model representing input-to-output dependencies with a vanilla autoencoder representing input-to-input dependencies. Shapley-based explainability is applied to both models to construct a feature-level vulnerability metric. Empirical evaluation on IEEE test systems demonstrates that the proposed framework more accurately identifies security-relevant vulnerabilities than conventional OPF-surrogate-model-only explainability approaches.

0.11

Data-Optimized Contingency Screening: A Machine Learning Approach to Power System Security

cs.AI cs.LG ·2026-09-03 ·Joshua Salako, Folajimi Osikomaiya, Olakorede Olamiju
published similarity 0.69
Abstract · Accepted for presentation at the 3rd EIE International Conference on Computing, Networking, Robotics and Telecommunication (EIECon), 2025. T…

Ensuring the security of the power system is essential for stability and reliability, especially in the event of disruption. Effective classification of contingency in power systems enables proactive decision-making and mitigates large-scale breakdowns and failures. This study explores the use of machine learning algorithms to classify security levels of contingencies in power systems into safe, moderate or severe classes. For this approach, Newton-Raphson load flow method extracts system data from contingency scenarios, using Overall Performance Index (OPI) as safety measure. For data pre-processing, Synthetic Minority Over-Sampling Technique (SMOTE) and Principal Component Analysis (PCA) is used to address class imbalance and reduce dimensionality, respectively. K-Nearest Neighbours (KNN), Random Forest (RF) and Support Vector Machines (SVM) is trained and evaluated on datasets generated through N-k contingency scenarios for k equal 1, 2, and 3 on IEEE-14 and IEEE-30 bus systems using four hybrid pre-processing configurations: normalized, SMOTE-balanced, PCA-transformed, and a combined SMOTE PCA-transformed. Performance is assessed by precision, recall and F1 score, with priority given to the severe contingency classes. The RF achieved the highest F1 scores of 0.97 in IEEE-30 and 0.86 in IEEE-14, SVM benefits significantly from PCA and improves the accuracy of the classification, while KNN is best suited for SMOTE and PCA conversion. The findings show that PCA contributes more than SMOTE to the overall performance of the model. However, SMOTE improves recall but can introduce false positives and is therefore a compromise of accuracy. This study highlights machine learning as a scalable and powerful alternative to traditional contingency analysis, which improves the assessment of security in real time.

0.25

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

eess.SY cs.LG ·2026-09-23 ·Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann Jäger +1 more
benchmarkcode/data similarity 0.67
Abstract · 15 pages, 3 figures. Supplementary information included. Code: https://github.com/EvEMTBench/evemtbench-benchmark

Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.

0.22

Protection-Oriented Assessment of Machine Learning-Based Fault Detection in Power Systems

cs.LG eess.SP ·2026-11-13 ·Julian Oelhaf, Georg Kordowich, Changhun Kim, Christian Bergler, Andreas Maier +2 more
publishedhot direction similarity 0.66
Abstract · 9 pages, 3 figures, 5 tables. Accepted for oral presentation at the 21st International Conference on Developments in Power System Protection…

Machine learning (ML)-based fault detectors are increasingly proposed for power system protection, yet aggregate metrics can obscure the consequences of false and missed trips. We present a protection-oriented assessment of three ML detectors and a sequence-current reference on PROTECT-90, comprising 9,022 simulated fault episodes on a 90 kV double-circuit line. The assessment combines five window conditions, causal window-end labelling, episode-grouped cross-validation, and operating-point selection under a fixed security budget. It reports security, dependability, detection timing, decision margins, and episode-level nuisance assertions. Gradient-boosted trees, a convolutional neural network, and logistic regression achieve AUC-ROC values above 0.999, yet at a security budget of $10^{-3}$ their developed-fault missed-trip rates range from 0.007% to 1.99%. Post-clearing false-trip rates of approximately 0.12-0.16% per window coexist with nuisance assertions in 11.3-19.1% of episodes. Among the analysed physical descriptors, missed trips are most consistently associated with higher fault resistance within the sampled range. An analytical current proxy suggests a fault-current gradient only partly reproduced by waveform-derived current (rank correlation 0.62). No single topology state or faulted phase consistently dominates within the sampled domain. Because PROTECT-90 contains fault episodes only, security is assessed on pre-fault and post-clearing windows rather than independent non-fault disturbances.

0.27

AC Power Flow Contingency Analysis Using a Single Deep Neural Network

eess.SY cs.LG ·2026-09-25 ·Md Obaidur Rahman, Junjie Qin, Vassilis Kekatos
similarity 0.65
Abstract · 10 pages, 5 figures

Contingency analysis using the AC power flow (AC-PF) model is a critical tool for accurate grid security assessment, but its computational burden increases with the number of operating scenarios and outage configurations to evaluate. Recent ML-based approaches typically require outage-specific training data, leading to offline training costs that scale with the number of contingencies. This work proposes a framework that reuses a single ML model trained solely on basecase AC-PF data to estimate post-contingency operating states under arbitrary single-line outages. The proposed approach formulates post-contingency state prediction as a fixed-point iteration. If the ML model is a deep neural network (DNN), we derive sufficient conditions that guarantee convergence and develop semidefinite programming (SDP) formulations to certify these conditions for a given DNN. Numerical tests on the IEEE 118-bus system demonstrate that the proposed SDP formulations are tight, that the certified conditions hold for all tested contingencies, and that the resulting method produces accurate post-contingency state estimates within only a few iterations.

0.46

A Standardized Framework for Machine Learning in Power System Protection

cs.LG cs.AIeess.SP ·2026-08-20 ·Julian Oelhaf, Georg Kordowich, Paula Andrea Pérez-Toro, Christian Bergler, Johann Jäger +2 more
publishedbenchmarkcode/data similarity 0.63
Abstract · 32 pages, 4 figures, 26 tables. Code: https://github.com/julianoelhaf/protection-eval-framework. Dataset: PROTECT-90, doi:10.5281/zenodo.211…

Studies of machine-learning-based power-system protection increasingly report near-perfect scores, yet the meaning of those scores depends strongly on the evaluation setting. Protection task, physical scope, measurements, timing, targets, preprocessing, and validation often vary jointly and remain incompletely specified. This paper proposes a standardization-oriented framework that treats evaluation design as part of the scientific contribution. It defines seven required study dimensions: protection objective, physical scope, observability, timing and decision windows, targets and sample validity, validation protocol, and evaluation outputs. The framework is instantiated in a bounded case study on the public PROTECT-90 electromagnetic-transient benchmark, comprising 9022 simulated episodes from a 90 kV double-line topology, for onset-conditioned fault classification and localization. Under centralized sensing, simulation-metadata-aligned 20 ms windows, and episode-grouped validation, a multi-layer perceptron (MLP) achieved a five-fold mean macro-averaged F1 score of 0.991 +/- 0.001 for classification and a localization mean absolute error of 10.20 +/- 0.25% of line length (mean +/- std across episode-grouped folds). Extending the decision horizon to 50 ms preserved this task-dependent performance asymmetry, while reduced observability approximately doubled the MLP localization error but had little effect on classification. A synchronized two-ended conventional locator outperformed the learning locators under its richer clean information set, and measurement degradation showed that clean predictive performance did not determine robustness. The framework turns evaluation assumptions into explicit, reproducible evidence and provides a basis for more comparable, auditable evaluation and future certification-oriented assessment of machine-learning protection functions.

0.77

Decision-Focused Learning for Cyber-Physical Risk-Aware Power Grid Operations

cs.CR ·2026-10-09 ·Ayesha Siddiqua Dina, Ebisa D. Wollega, Afzal Hossain Sohag
similarity 0.63
Abstract

Power grid cyber-physical security requires intrusion detection methods that account for the operational consequences of detection errors. However, the existing intrusion detection approaches primarily focus on the predictive performance of learning algorithms, while downstream operational costs are often optimized independently, which can lead to inferior operational performance. To help alleviate this problem, we propose a novel optimization-learning cyber-physical-risk-informed framework that communicates iteratively to minimize power grid operational costs. This framework translates machine learning prediction errors into power grid operational cyber-physical-risk costs. Experimental results on two power grid operation datasets, Industrial Control System (ICS) Cyber Attack and Sherlock, show that the proposed approach improves power grid operation costs compared with the traditional approach.

0.16

Risk-certified prompt optimization for LLM-as-a-judge guardrails

cs.CL cs.LG ·2026-11-15 ·Hussein Jawad, Alexandre Landeau, Guy Fleury Iradukunda, Paul Beaumont, Théodore Rezel +2 more
similarity 0.61
Abstract

LLM-as-a-judge guardrails are often controlled primarily through system prompts, yet standard prompt optimization methods target average performance rather than explicit safety constraints. This paper studies system-prompt selection as a constrained optimization problem: maximize benign pass rate while keeping the missed-attack rate below a user-specified level α with finite-sample statistical control. The framework combines LLM-based judging, automatic prompt generation, and distribution-free risk certification. This work instantiates it in two procedures: CPS and CRISP. CPS generates a fixed pool of prompts from training data, then certifies candidates on a held-out evaluation set using simultaneous upper confidence bounds and selects the certified prompt with the highest benign utility. CRISP instead integrates risk feedback into an adaptive search, using hard example-guided rewriting and a reusable-holdout interface to steer generation toward the feasible utility frontier. Experiments on four datasets covering prompt injection, system-prompt leakage, and sensitive-information disclosure show that risk-certified selection consistently respects the target missed-attack level on heldout tests, while utility improves as the permitted risk is relaxed. CRISP is especially useful when fixed-pool search fails to produce certifiable high-utility candidates.

0.13