A Defense-Aware Explainable AI Framework for Feature-Level Vulnerability Analysis in Optimal Power Flow

S. M. Monzurul Hoque Chowdhury, Qinghua Li, Jianhui Wang

cs.CR ·submitted 2026-10-28 21:31 UTC · v1

Abstract

Optimal power flow (OPF) is a foundational analysis in power system operation, and inaccuracies in OPF decision-making can result in significant operational and security consequences. With the increasing adoption of machine-learning-based OPF surrogate models for real-time and large-scale applications, power system operation has become more susceptible to cyber threats, including data manipulation and false data injection attacks. Explainable artificial intelligence (XAI), particularly Shapley value-based approaches, has been employed to quantify the influence of input features on OPF outputs. Features exhibiting high influence are commonly interpreted as vulnerable. However, this interpretation neglects the role of attack detection mechanisms in the system, which typically monitor input-to-input relationships to detect anomalous behavior. Consequently, highly influential features may be readily detectable and may not represent the most vulnerable attack surfaces. To address this limitation, we propose a defense-aware explainable AI framework that explicitly incorporates attack detectability alongside operational impact. The framework integrates an OPF surrogate model representing input-to-output dependencies with a vanilla autoencoder representing input-to-input dependencies. Shapley-based explainability is applied to both models to construct a feature-level vulnerability metric. Empirical evaluation on IEEE test systems demonstrates that the proposed framework more accurately identifies security-relevant vulnerabilities than conventional OPF-surrogate-model-only explainability approaches.

Closest papers

Nearest neighbours by meaning across the whole index.

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

eess.SY cs.LG ·2026-09-23 ·Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann Jäger +1 more
benchmarkcode/data similarity 0.72
Abstract · 15 pages, 3 figures. Supplementary information included. Code: https://github.com/EvEMTBench/evemtbench-benchmark

Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.

0.22

Severity-Aware Minimum Security Sets for Accelerated Preventive SCOPF Using Machine Learning

eess.SY ·2026-10-14 ·Mohammad Iman Alizadeh, Saeed Zeynali, Salah Ghamizi, Sylvain Kubler
similarity 0.70
Abstract

This paper proposes a severity-aware machine learning framework for reducing the computational burden of preventive AC security-constrained optimal power flow (PSCOPF). The central idea is to identify a compact minimum security set (MSS) containing only the non-dominated contingencies and associated post-contingency constraints that materially influence the preventive operating point while satisfying a prescribed severity tolerance. An offline procedure combines AC security assessment, severity-based ranking, non-dominated screening, and iterative reduced PSCOPF. After each reduced PSCOPF solution, exhaustive security assessment over all credible contingencies identifies additional contingency--constraint pairs whose residual severity exceeds the specified threshold. Severity is characterized using the normalized number, accumulated magnitude, maximum magnitude, and average magnitude of post-contingency violations. The resulting operating-point-dependent MSSs are used as labels for a supervised multi-label learning model that predicts the security elements required to construct the reduced PSCOPF directly from the pre-contingency state. The proposed framework therefore focuses the optimization on the contingencies and constraints that affect preventive control decisions, reducing problem size and computation time while explicitly controlling residual post-contingency severity. Results on the IEEE 60-bus and 118-bus systems, the latter having an approximately seven-times-larger PSCOPF formulation, demonstrate substantial computational reductions with limited impact on the preventive operating solution.

0.22

AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks

eess.SY ·2026-08-11 ·Ze Yu, Hongwei Zhen, Chao Shen, Mingyang Sun
similarity 0.69
Abstract

The rapid growth of large language model (LLM) services is expanding AI data centers (AIDCs), increasing electricity demand and associated carbon emissions. Renewable energy integration can mitigate these impacts but also strengthens the coupling between AIDC loads and inverter-interfaced generation, creating cross-domain cyber-physical vulnerabilities. Specifically, adversarial AI requests alter AIDC power demand, whereas inverter control tampering modifies source-side dynamics, and their combined impact on system stability varies with generation forecast and demand response uncertainties. To this end, we propose an uncertainty-aware AIDC microgrid vulnerability assessment framework under computing-power coordinated attacks. First, the framework maps adversarial AI requests to AIDC power variations and represents uncertainties in attack-induced demand responses and photovoltaic (PV) forecasts through confidence-weighted realizations. Then, impedance based stability analysis combines these realizations with bounded inverter parameter tampering to construct attack reachable domains and identify critical attack time windows. Furthermore, a separate criterion identifies fixed coordinated attack vectors that retain destabilizing capability throughout each selected window. Case studies demonstrate that, unlike either attack component applied alone, coordinated attacks within identified critical windows induce sustained inverter frequency oscillations with peak absolute deviations exceeding 20% of nominal frequency, whereas the evaluated out-of-window response remains bounded. The proposed method further identifies critical attack windows and the associated coordinated attack vectors.

0.04

Decision-Focused Learning for Cyber-Physical Risk-Aware Power Grid Operations

cs.CR ·2026-10-09 ·Ayesha Siddiqua Dina, Ebisa D. Wollega, Afzal Hossain Sohag
similarity 0.69
Abstract

Power grid cyber-physical security requires intrusion detection methods that account for the operational consequences of detection errors. However, the existing intrusion detection approaches primarily focus on the predictive performance of learning algorithms, while downstream operational costs are often optimized independently, which can lead to inferior operational performance. To help alleviate this problem, we propose a novel optimization-learning cyber-physical-risk-informed framework that communicates iteratively to minimize power grid operational costs. This framework translates machine learning prediction errors into power grid operational cyber-physical-risk costs. Experimental results on two power grid operation datasets, Industrial Control System (ICS) Cyber Attack and Sherlock, show that the proposed approach improves power grid operation costs compared with the traditional approach.

0.16

Adversarially-Informed Node Criticality Identification in Power Grid Measurements

eess.SY math.OC ·2026-08-27 ·Koto Omiloli, Olugbenga Moses Anubi
similarity 0.67
Abstract

Power grid state estimation relies on sensor measurements that are increasingly vulnerable to adversarial corruption in cyberphysical environments, potentially leading to significant deviations in system observations. This motivates the need to identify critical measurement nodes whose compromise results in the most severe system-level impact. However, existing node criticality methods primarily rely on structural or steady-state analyses and do not explicitly account for adversarial effects on system behavior. To address this gap, this paper proposes an adversarially informed framework for identifying critical measurement nodes in linearized power systems. Within this framework, a structured attack generation mechanism is developed to construct stealthy and effective false data injection attacks (FDIAs) against an H-infinity resilient state estimator. Node criticality is then evaluated using coalition-based marginal contributions of compromised sensor subsets, estimated via permutation sampling over a prescribed set of admissible nodes, with the resulting importance scores mapped to the corresponding physical buses. Simulation results on the IEEE 14-bus system show that adversarially identified nodes induce larger deviations in frequency, voltage angle, and net power compared to randomly selected nodes, demonstrating the effectiveness of the proposed framework.

0.23

Explainable Artificial Intelligence for Industrial Cybersecurity: A Review of Methods, Operational Integration, and Research Challenges

cs.CR eess.SY ·2026-08-31 ·Amr S. Mohamed, Charlotte Fritz, Ahmad Mohammad Saber, Yiqun Ma, Ratinder Kaur +3 more
survey similarity 0.67
Abstract · 31 pages, 6 figures

The increasing digitalization of industrial infrastructure and the convergence of information technology (IT) and operational technology (OT) have expanded the cyberattack surface of industrial systems. To address the growing complexity of cyber threats, artificial intelligence (AI) and machine learning (ML) techniques are increasingly deployed within industrial cybersecurity operations, particularly in Security Operations Centers (SOCs). While these approaches improve anomaly detection, threat analysis, and automated response, their opaque decision-making presents challenges for operational trust, regulatory compliance, and incident response. EXplainable Artificial Intelligence (XAI) has emerged as a promising paradigm to improve the transparency and interpretability of AI-driven cybersecurity systems and decisions. This paper provides a comprehensive review of XAI techniques in industrial cybersecurity, focusing on industrial SOC environments and operational security workflows. We examine the role of AI in industrial SOC workflows, the types of operational data leveraged in industrial environments, and the benefits and limitations of AI-based threat detection. We then review major families of XAI approaches, including feature attribution methods, surrogate models, rule-based explanations, and visualization techniques, and analyze their applicability to industrial use cases. We further discuss the operational, regulatory, and safety requirements that distinguish industrial systems from traditional IT environments. Key challenges are examined, including limited labeled datasets, model reliability, explainability-performance tradeoffs, and the integration of XAI tools into SOC workflows. Finally, we identify open research directions and opportunities for developing trustworthy, operationally viable, and domain-specific XAI-enabled cybersecurity solutions for industrial environments.

0.26

Protection-Oriented Assessment of Machine Learning-Based Fault Detection in Power Systems

cs.LG eess.SP ·2026-11-13 ·Julian Oelhaf, Georg Kordowich, Changhun Kim, Christian Bergler, Andreas Maier +2 more
publishedhot direction similarity 0.67
Abstract · 9 pages, 3 figures, 5 tables. Accepted for oral presentation at the 21st International Conference on Developments in Power System Protection…

Machine learning (ML)-based fault detectors are increasingly proposed for power system protection, yet aggregate metrics can obscure the consequences of false and missed trips. We present a protection-oriented assessment of three ML detectors and a sequence-current reference on PROTECT-90, comprising 9,022 simulated fault episodes on a 90 kV double-circuit line. The assessment combines five window conditions, causal window-end labelling, episode-grouped cross-validation, and operating-point selection under a fixed security budget. It reports security, dependability, detection timing, decision margins, and episode-level nuisance assertions. Gradient-boosted trees, a convolutional neural network, and logistic regression achieve AUC-ROC values above 0.999, yet at a security budget of $10^{-3}$ their developed-fault missed-trip rates range from 0.007% to 1.99%. Post-clearing false-trip rates of approximately 0.12-0.16% per window coexist with nuisance assertions in 11.3-19.1% of episodes. Among the analysed physical descriptors, missed trips are most consistently associated with higher fault resistance within the sampled range. An analytical current proxy suggests a fault-current gradient only partly reproduced by waveform-derived current (rank correlation 0.62). No single topology state or faulted phase consistently dominates within the sampled domain. Because PROTECT-90 contains fault episodes only, security is assessed on pre-fault and post-clearing windows rather than independent non-fault disturbances.

0.34

Self-Verifying Anomaly Detection using Explainable AI for Cybersecurity of DER Networks

cs.CR cs.AIcs.LG ·2026-09-11 ·Damilola Popoola, Souradeep Bhattacharya, Manimaran Govindarasu
published similarity 0.66
Abstract · 5 pages, 5 Figures, Submitted and Accepted at IEEE PES General Meeting 2026

The rapid growth of Distributed Energy Resources (DERs) has significantly expanded the cyber attack surface of modern power grids. Furthermore, increasing sophistication in attack techniques demands anomaly detection systems (ADS) that are accurate, interpretable, and reliable to support DER cybersecurity. While ML-based ADS provide strong detection capabilities, their black-box nature reduces operator trust and limits Security Operation Center's (SOC) ability to effectively interpret alerts and respond, highlighting the need for explainable Artificial Intelligence (XAI) to ensure transparency and operational confidence. This paper presents an XAI-based anomaly detection framework tailored for DER networks (ExCYDER). The proposed framework uses a self-verifying mechanism that validates ADS alerts to ensure trustworthy decision-making. ExCYDER combines LightGBM with SHAP to check whether each model decision aligns with its feature-attribution evidence, allowing the system to confirm that its internal reasoning is consistent and reliable. Experiments on a realistic DNP3 dataset achieved over 98% detection accuracy, an average rule--SHAP consistency of 44.6%, a SHAP latency of 14.5 ms per alert, and a confidence deviation within 5%, demonstrating stable verification behavior with minimal computational overhead. The framework distinguished between coherent and inconsistent alerts without compromising detection accuracy, demonstrating that integrated verification within XAI-based ADS enhances interpretability, auditability, and operational robustness for DER-focused SOCs.

0.56