CS Paper Radar

AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks

Ze Yu, Hongwei Zhen, Chao Shen, Mingyang Sun

eess.SY ·submitted 2026-08-11 08:31 UTC · v2

Abstract

The rapid growth of large language model (LLM) services is expanding AI data centers (AIDCs), increasing electricity demand and associated carbon emissions. Renewable energy integration can mitigate these impacts but also strengthens the coupling between AIDC loads and inverter-interfaced generation, creating cross-domain cyber-physical vulnerabilities. Specifically, adversarial AI requests alter AIDC power demand, whereas inverter control tampering modifies source-side dynamics, and their combined impact on system stability varies with generation forecast and demand response uncertainties. To this end, we propose an uncertainty-aware AIDC microgrid vulnerability assessment framework under computing-power coordinated attacks. First, the framework maps adversarial AI requests to AIDC power variations and represents uncertainties in attack-induced demand responses and photovoltaic (PV) forecasts through confidence-weighted realizations. Then, impedance based stability analysis combines these realizations with bounded inverter parameter tampering to construct attack reachable domains and identify critical attack time windows. Furthermore, a separate criterion identifies fixed coordinated attack vectors that retain destabilizing capability throughout each selected window. Case studies demonstrate that, unlike either attack component applied alone, coordinated attacks within identified critical windows induce sustained inverter frequency oscillations with peak absolute deviations exceeding 20% of nominal frequency, whereas the evaluated out-of-window response remains bounded. The proposed method further identifies critical attack windows and the associated coordinated attack vectors.

Closest papers

Nearest neighbours by meaning across the whole index.

Adversarially-Informed Node Criticality Identification in Power Grid Measurements

eess.SY math.OC ·2026-08-27 ·Koto Omiloli, Olugbenga Moses Anubi
similarity 0.71
Abstract

Power grid state estimation relies on sensor measurements that are increasingly vulnerable to adversarial corruption in cyberphysical environments, potentially leading to significant deviations in system observations. This motivates the need to identify critical measurement nodes whose compromise results in the most severe system-level impact. However, existing node criticality methods primarily rely on structural or steady-state analyses and do not explicitly account for adversarial effects on system behavior. To address this gap, this paper proposes an adversarially informed framework for identifying critical measurement nodes in linearized power systems. Within this framework, a structured attack generation mechanism is developed to construct stealthy and effective false data injection attacks (FDIAs) against an H-infinity resilient state estimator. Node criticality is then evaluated using coalition-based marginal contributions of compromised sensor subsets, estimated via permutation sampling over a prescribed set of admissible nodes, with the resulting importance scores mapped to the corresponding physical buses. Simulation results on the IEEE 14-bus system show that adversarially identified nodes induce larger deviations in frequency, voltage angle, and net power compared to randomly selected nodes, demonstrating the effectiveness of the proposed framework.

0.23

A Defense-Aware Explainable AI Framework for Feature-Level Vulnerability Analysis in Optimal Power Flow

cs.CR ·2026-10-28 ·S. M. Monzurul Hoque Chowdhury, Qinghua Li, Jianhui Wang
similarity 0.69
Abstract

Optimal power flow (OPF) is a foundational analysis in power system operation, and inaccuracies in OPF decision-making can result in significant operational and security consequences. With the increasing adoption of machine-learning-based OPF surrogate models for real-time and large-scale applications, power system operation has become more susceptible to cyber threats, including data manipulation and false data injection attacks. Explainable artificial intelligence (XAI), particularly Shapley value-based approaches, has been employed to quantify the influence of input features on OPF outputs. Features exhibiting high influence are commonly interpreted as vulnerable. However, this interpretation neglects the role of attack detection mechanisms in the system, which typically monitor input-to-input relationships to detect anomalous behavior. Consequently, highly influential features may be readily detectable and may not represent the most vulnerable attack surfaces. To address this limitation, we propose a defense-aware explainable AI framework that explicitly incorporates attack detectability alongside operational impact. The framework integrates an OPF surrogate model representing input-to-output dependencies with a vanilla autoencoder representing input-to-input dependencies. Shapley-based explainability is applied to both models to construct a feature-level vulnerability metric. Empirical evaluation on IEEE test systems demonstrates that the proposed framework more accurately identifies security-relevant vulnerabilities than conventional OPF-surrogate-model-only explainability approaches.

0.11

System-Level Factors Influencing AGC Cyber-Attack Success and RAS Vulnerability in Multi-Area Grids

eess.SY ·2026-10-30 ·Abdulmannan Ajabnoor, Zhi Jin Zhang, Maryam Saeedifard, Dominic Groß
published similarity 0.67
Abstract

Automatic generation control (AGC) stabilizes frequency and scheduled power exchanges among interconnected areas, yet its reliance on communication networks introduces cyber-vulnerabilities. This work examines coordinated AGC cyber-attacks in the presence of remedial action schemes (RAS) and identifies operating conditions under which an attacker can drive grid frequency beyond safe limits while evading RAS. A feedback-based attack policy is used to manipulate AGC signals and steer system frequency toward unsafe trajectories. Then, a large nested-loop parametric sweep---spanning attacked-area inertia relative to its interconnected neighboring area, AGC capacity versus maximum tie-line transfer, AGC update rate, load damping, and bi-directional power transfers---generates over 1.45 million scenarios. These are classified using a decision tree to establish guidelines to distinguish successful from unsuccessful attacks based on frequency deviations. The resulting vulnerability guidelines are validated on a three-area system using phasor-domain simulations with IEEE 9-bus area models, detailed turbine--governor dynamics, and under/over-frequency load and generation shedding. Results show that specific combinations of AGC capacity, inertia distribution, and pre-attack tie-line loading increase the likelihood of successful attacks, offering operators actionable criteria for identifying vulnerable operating conditions.

0.41

Profile Screening and Frequency-Secure Operating Limit Derivation for Data Center Microgrids

eess.SY ·2026-11-17 ·Zishuo Yang, Yu Ma, Jong Ha Woo, Aaditya Pandey, Wenyuan Tang +2 more
similarity 0.67
Abstract

Rapid power variations from artificial intelligence (AI) workloads pose frequency-security challenges for islanded data-center microgrids. This paper proposes a generator step- response-based framework to rapidly screen candidate load pro- files and derive frequency-secure operating limits for IT workload scheduling. Identified generator responses are superimposed to assess the cumulative frequency effects of successive load changes without repeated dynamic simulations. The framework identifies potentially unsafe intervals and determines allowable load magni- tudes, ramp rates, and minimum event spacing, while accounting for prediction uncertainty and governor limits. Validation on a 2.5 MVA islanded microgrid with eight generator configurations and 14 synthetic AI workload profiles shows that 94.75% of 40,208 assessment windows receive decisive screening labels, with no frequency-violating windows classified as secure.

0.37

Privacy-Preserving Coordinated Operation of Power Grids and AI Data Centers: A Checkpoint-Aware Three-Phase Scheme

eess.SY ·2026-09-22 ·Ziang Liu, Ruizhang Yang, Xin Cui, Francis Yunhe Hou
similarity 0.65
Abstract · 10 pages

The rapid growth of large language model training and serving is driving AI data centers (AIDCs) toward gigawatt scale. Unlike conventional commercial loads, AIDCs possess significant operational flexibility through dynamic voltage and frequency scaling (DVFS) of training and inference workloads, while periodic model checkpointing can induce abrupt power drops and rebounds that erode operating reserves and increase transmission congestion risks. Coordinating AIDC operation with grid scheduling under these unique operational characteristics is challenging because grid and AIDC operators are generally unwilling to share proprietary data and decision-making authority. This paper proposes a hierarchical privacy-preserving coordinated operation scheme between the power grid and AIDCs to address this gap. The proposed scheme contains three phases. In Phase I, the grid operator computes a certified inner approximation of the AIDCs security region for subsequent coordination. In Phase II, the AIDC operator coordinates training and inference AIDCs to optimize workload allocation within the certified security region and generate power schedules and checkpoint alerts. In Phase III, the grid operator solves a checkpoint-aware two-stage robust optimal power flow (OPF) considering renewable generation and checkpoint uncertainties. By exchanging only compact interface information, the framework preserves the privacy of both grid and AIDCs, avoids frequent iterative communication, and enables secure coordination with guaranteed feasibility. Numerical studies on a modified IEEE 14-bus system and a modified NYISO system demonstrate the effectiveness, robustness, and security of the proposed framework.

0.19

Hierarchical Sensor-Spoofing Defence Framework for Networked DC Microgrids via Cyber-Physical Coordination

eess.SY ·2026-08-13 ·Mengxiang Liu, Xin Zhang, Shiyi Zhao, Ruilong Deng
top venue similarity 0.64
Abstract · IEEE TSG

In parallel to the cyber attack that manipulates the reference points of distributed energy resources (DERs) by maliciously accessing the remote monitoring and control system, the vulnerability of voltage/current sensors to electromagnetic interference (EMI) in the physical domain has been widely discussed. Existing research efforts against sensor spoofing attacks can be classified into physical prevention and cyber detection/mitigation. These defence methods each have strengths and weaknesses in balancing cost, security, and performance in a single DER, yet systematic research on their multi-layer efficient coordination across DERs remains limited. Towards this end, this paper proposes a hierarchical framework to detect and mitigate sensor spoofing attacks in networked microgrids (NMGs) via {multi-layer cyber-physical coordination}. It requires only to deploy physical prevention technologies at critical points, i.e., the local points of common coupling (PCC) of MGs, such that cyber detection/mitigation algorithms can be adopted based on the secured sensor readings to counter sensor spoofing attacks in DERs. The framework employs an MG-DER coordinated proactive detection scheme to strategically trigger parameter perturbations, under which the intelligent sensor spoofing attacks can be {effectively} disclosed. Afterwards, mitigation schemes based on MG-DER coordination are activated to recursively and accurately estimate sensor biases. Experiments on a cyber-physical DC NMG testbed confirm the framework's effectiveness across diverse attack scenarios.

0.29

RESILAGENT: A Three-Pillar Architecture for Cyber-Physical Resilience in Electrical Power and Energy Systems

cs.CR cs.AIeess.SY ·2026-11-16 ·Nikolaos Kekatos, Georgios Koutidis, Konstantinos Antonakopoulos, Stylianos Basagiannis, Sokratis Katsikas +4 more
publishedbenchmark similarity 0.64
Abstract · 7 pages, 5 figures, 1 table. Accepted at the 2026 IEEE International Conference on Cyber Security and Resilience (IEEE CSR 2026)

Electrical Power and Energy Systems face hybrid threats that combine cyber intrusions, physical sabotage and climate-driven stress, and routinely outpace today's siloed monitoring stacks. We present RESILAGENT, a concept architecture organised around three operational pillars, Sensing & Data Intelligence, Resilience Analytics & Reporting, and Incident Response & Recovery, mediated by a Cloud-based Orchestrator and exercised through a closed Detect-Simulate-Decide-Sign loop. The framework fuses agentic artificial intelligence and multimodal large language models for cross-modal detection, real-time digital twins for what-if simulation, and a permissioned blockchain anchor for tamper-evident threat intelligence and CER/NIS2-aligned evidence. We instantiate it on two scenarios, a transmission operator under coordinated cyber compromise, sabotage and heatwave, and a distribution operator under a supply-chain compromise during a storm, and report an IEEE-bus micro-benchmark that quantifies each pillar through false-data-injection attack detection, cyber-physical fusion lift, N-1 contingency screening and anchor cost.

0.44

Attack-Resiliency Analytics for Wide-Area Control Systems in Smart Grids

eess.SY ·2026-09-29 ·Mohammad Zakaria Haider, Prabin Mali, Nur Imtiazul Haque, Muhammad Nadeem, Sumit Paudyal +1 more
similarity 0.63
Abstract

Wide-area monitoring, protection, and control (WAMPAC) systems damp inter-area oscillations in large interconnected grids, but their reliance on synchronized PMU measurements carried over wide-area networks exposes them to false data injection (FDI) attacks. This paper presents an attack-resiliency analytics framework that formally models the coupled dynamics of the wide-area damping loop, automatic generation control, and the governor and excitation systems, and formulates the optimal stealthy FDI attack as a mixed-integer linear program (MILP). The anomaly detection model (ADM) enters as a replaceable constraint set: either a static bad-data detection (BDD) rule or a boundary learned from benign operation calibrated to a common false-positive rate. On the IEEE 39 and 118 bus systems, with reference dynamics validated on an OPAL-RT hardware-in-the-loop testbed, the optimal attack with wide-area access attains 3.3 and 8.1 times the benign objective and reaches a 0.5Hz frequency excursion more than twice as fast as an attack confined to automatic generation control. Learned boundaries reduce the attack objective by 15.5 55.0% and prevent over-frequency relay trips in all configurations, with feasible stealthy attacks remaining in every case, and residual risk tracks the width of the learned boundary rather than the detector family.

0.31