CS Paper Radar

When Repository Labels Are Not Image-Level Truth: A Supervision Auditing Framework for Chest Radiograph AI

Yesika Alexandra Agudelo-Londoño, Jhon Wilmer Pino-Román, Brahian Carrera Rodríguez, José Miguel Castañeda-Bedoya, Juan Pablo Gómez-López, Aura C. Puche-Sarmiento, Niharika S. D'Souza, Juan Sebastian Osorio-Valencia, Jon E. Duque-Grajales, Jazmín Ximena Suárez-Revelo, Jorge Mario Vélez-Arango, Gabriel Castrillón

eess.IV cs.CV ·submitted 2026-08-10 18:00 UTC · v1
published

Abstract

Public chest X-ray repositories are widely used to train medical AI systems, yet their labels are typically extracted from radiology reports rather than verified directly on images. As a result, repository labels are often treated as image-level ground truth without validating whether they reflect what is actually visible in the radiograph. We introduce Repository Supervision Auditing (RSA), a framework that evaluates repository-derived labels against expert image-level annotations before model development. Using cardiomegaly in MIMIC-CXR as a case study, RSA compares repository labels with radiologist-reviewed image annotations, characterizes disagreement sources, and builds a curated cohort for deployment-oriented evaluation. Repository-derived cardiomegaly labels showed near-zero agreement with expert image-level assessment, identifying only 1% of expert-confirmed cases. Most discrepancies resulted from non-mention rather than explicit report negation, with expert-confirmed cardiomegaly identified in nearly half of studies assigned a repository-derived No Finding label. Using the resulting expert-curated cohort, a DenseNet121 model achieved a test ROC-AUC of 0.853. These findings show that repository labels may not reliably represent image-level truth and highlight supervision auditing as a critical step for developing trustworthy medical imaging AI.

Comment
Accepted (oral) at the 3rd MICCAI Student Board (MSB) EMERGE Workshop, MICCAI 2026. This is the authors' version; the final authenticated version will appear in Springer Lecture Notes in Computer Science (LNCS). 10 pages, 3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

cs.CL cs.AI ·2026-09-16 ·Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency +3 more
similarity 0.70
Abstract · Preprint

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.

0.10

Retrieval-Grounded Multi-View Reasoning for Clinically Reliable Radiology Report Generation

cs.CV ·2026-11-03 ·Wanshu Fan, Zeyu Wang, Zheng Tong, Qi Ai, Wencai Weng +6 more
similarity 0.70
Abstract

Chest radiograph report generation is hampered by retrieved reports that resemble the current image but are clinically inconsistent with it, and by diagnostic-label imbalance. We present RG-MVR, a retrieval-grounded framework comprising Retrieval-Augmented Evidence Grounding, which combines dense memory summaries with visually gated sparse retrieved evidence; Adaptive Multi-view Evidential Reasoning, which weights image, memory, and retrieved evidence per case; and a Clinical Prompt Learner, which models finding mention separately from positive, negative, or uncertain status. On MIMIC-CXR, RG-MVR achieved a clinical-label F1 of 0.483 and a BLEU-4 of 0.118 (IU X-ray: 0.202 and 0.110). In an exploratory external cohort of 22 examinations, clinical-label agreement declined markedly (F1, 0.071) and unsupported statements remained common, although physicians found fewer unsupported temporal comparisons (9 vs. 20 cases) and device-related statements (7 vs. 15) than with the baseline. Evidence-aware retrieval and structured diagnostic prompting may reduce specific reporting errors, but broader external validation is required.

0.22

From Augmentation to Synthetic Evidence: Evaluating Generated Chest Radiographs at Dataset Intake

cs.CV cs.AIcs.LG ·2026-10-21 ·Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz
position similarity 0.69
Abstract

While generated chest radiographs can serve as valuable data augmentation when explicitly declared, the same pixels become unsupported evidence when submitted as records of real clinical examinations. We study this dataset-intake vulnerability by disentangling three questions: (1) whether an image passes an automated technical quality check, (2) whether an origin classifier flags it as synthetic, and (3) whether a trusted provenance record supports the claimed clinical acquisition. In this study, a submitter uses Qwen3.8-27B to select up to 20 candidate radiographs from pools of 1,000 Cheff-identified or SynthCheX images, while a receiver evaluates image quality via MedGemma 1.5 and predicts origin using a linear probe over frozen DINOv3 features. Although quality selection increases MedGemma quality passes from 12/20 to 19/20 for Cheff-identified images and from 8/20 to 17/20 for SynthCheX, we find no evidence that candidate selection increases passage through both checks simultaneously: zero selected Cheff-identified images pass both gates, and uniform, quality-guided, and surrogate-guided selection yield 2, 1, and 2 SynthCheX passes out of 20, respectively. On unprocessed test cohorts, the origin classifier rejects 4,677 of 5,000 SynthCheX images at a nominal 5% false-alarm rate (flagging 110 of 2,297 real NIH radiographs), yet leaves 152 SynthCheX images that pass both pixel-level checks. Moreover, pixel-level screening is fragile to routine distribution shifts: JPEG compression reduces SynthCheX-versus-NIH AUROC from 0.987 to 0.841, and applying the NIH-calibrated threshold to an external genuine cohort (Open-I) triggers false alarms on 568 of 957 authentic radiographs (59.4%). Because pixel-level checks can filter submissions but cannot verify clinical acquisition claims, we argue that dataset intake pipelines must record and verify source provenance independently of image pixels.

0.13

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.69
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.13

RadRef: A Reference-Free Metric for Radiology Report Generation

cs.LG ·2026-11-09 ·Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin +1 more
similarity 0.68
Abstract

AI-generated radiology reports are commonly evaluated against radiologist-authored references, limiting the applicability of standard reference-based metrics when no reference is available. We introduce RadRef, a reference-free metric that scores report claims against image-derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. By evaluating findings beyond the report's stated claims, RadRef assesses omissions as well as unsupported assertions. On ReXVal, RadRef achieves $73.1\%$ agreement with radiologist rankings among non-tied same-radiograph report pairs, with $61.8\%$ pair coverage and $64.3\%$ tie-inclusive agreement. Its non-tied agreement is close to GREEN ($73.9\%$) and RadFact ($72.6\%$), with its strongest relative results on omissions. We further evaluate $100$ model-generated and $100$ radiologist-authored reports from $100$ MIMIC-CXR studies, independently annotated by two board-certified radiologists. On same-image omission rankings, RadRef attains Kendall's $τ_b = 0.295$, compared with $0.386$ between the readers. In separate paired comparisons across generated reports, no evaluated comparator significantly outperforms RadRef on omissions. The same image-grounded representation provides a false-finding readout, RadRef-FF, with $τ_b = 0.32$ on ReXVal and $0.29$ in the reader study. Controlled perturbations confirm that RadRef depends on the radiograph, report, and clinical indication. RadRef enables image-grounded evaluation before a radiologist-authored reference exists, supporting quality monitoring of report-generation systems in clinical settings, and complements reference-based metrics when one is available.

0.17

A radiographic world model for clinical reasoning and evidence generation

cs.AI ·2026-09-07 ·Suyang Xi, Songtao Hu, Shansong Wang, Mojtaba Safari, Luke del Balzo +6 more
highly cited similarity 0.68
Abstract

Medical imaging artificial intelligence (AI) is commonly developed as separate mappings from radiographs to diagnostic outputs or from clinical descriptions to generated images, although both arise from the same underlying radiographic state. A world-model formulation instead seeks to learn an internal representation of this state that can support both clinical readout and conditional simulation of radiographic observations. Here we introduce MedDream, a radiographic world model that learns a shared continuous latent state from paired chest radiograph-text observations for diagnostic reasoning and report-conditioned evidence generation. MedDream was pretrained on 2.65 million leakage-controlled chest radiograph-text pairs curated from 4.40 million candidates. Across eight clinical datasets and two independent reader cohorts, MedDream outperformed leading diagnostic and generative comparators. For diagnostic reasoning, MedDream showed strong generalization across disease recognition, label-scarce adaptation, severity assessment, and localization, while MedDream-supported review increased mean resident concordance with independent radiologist consensus from 56.3% to 63.0%. For evidence generation, MedDream produced radiographs that preserved clinically relevant pathology and improved downstream performance on held-out real data, with synthetic augmentation increasing external VinDr-CXR macro-AUROC from 76.4% to 81.4%. More importantly, conditioning generation on prespecified subgroup performance gaps enabled targeted evidence construction, increasing weighted F1 by 3.1 percentage points in Asian patients, whereas matched-volume unguided augmentation decreased it by 2.3 points. These findings establish radiographic world models as a path toward medical AI that learns clinically meaningful internal states for interpreting, simulating, and constructing evidence for clinical use.

0.36

Interleaving anatomical inspection and diagnostic reasoning for explainable radiology report generation

cs.CV cs.AI ·2026-11-10 ·Chentao Huang, Runlong Lin, Zhijun Wang, Yunxiang Li, Yuanyuan Sun +3 more
similarity 0.67
Abstract

Automated radiology report generation can draft clinically plausible reports, yet the pathway from visual evidence to reported findings remains opaque, leaving the diagnostic basis of these reports unexplained and the generated reports difficult to review or revise. We introduce ARIVE (Anatomy-guided Reasoning with Interleaved Visual Evidence), an explainable report generation framework that interleaves anatomical inspection with diagnostic reasoning prior to final report composition. To support this process, we constructed 159,416 multimodal chain-of-thought (MCoT) trajectories from MIMIC-CXR, wherein visual evidence from inspected anatomical regions informs subsequent clinical interpretation. Trained on these trajectories and further optimized using anatomical and clinical-content rewards, ARIVE achieved superior clinical-efficacy performance compared with strong baselines on MIMIC-CXR and the abnormality-centered MIMIC-ABN. ARIVE's reports were competitive with those of leading models in blinded expert grading, and its MCoT trajectories earned high ratings for diagnostic traceability. Furthermore, a paired review evaluation suggests that access to MCoT can aid in identifying errors within generated reports.

0.15

MIRROR: Multimodal Intelligent Radiology Reasoning and Observation Reporter

cs.CV cs.AIcs.LG ·2026-08-17 ·Vignesh Nagarajan, Sriram Venkatapathy
hot direction similarity 0.67
Abstract · 8 pages, 5 figures, 5 tables, 24 references

A radiologist reading a model's output faces two problems. The model returns a number and no reason, and any system that turns that number into readable prose can quietly add claims the model never made. MIRROR is a research prototype built to separate those failures. It chains a multi-label classifier, a Grad-CAM localizer that turns each positive finding into a named anatomical region, and a report writer that receives the labels, probabilities, and regions but never the image. Because the language layer cannot see pixels, it cannot assert a finding the classifier did not make. We are precise about what that buys: a MIRROR report's findings are auditable against the probability vector, while the sentences framing them are ordinary generated text, and we show one stating a cardiothoracic ratio the system never measured. One registry holds the taxonomy, anatomy, and phrasing for chest X-ray, brain MRI, and head CT, so adding a modality is a data change; all three are routed and tested, one is trained. On ChestMNIST that classifier reaches macro AUROC 0.729 and ranks better than chance on all 14 labels, at 1.6 to 6.8 times the precision a random ranker would get. Yet at the default 0.5 threshold it emits no positive prediction at all for 11 of them, and its excellent-looking Brier score of 0.045 sits beside the 0.047 earned by a predictor that ignores the image. The discrimination is real; the decisions are not. Under the class imbalance normal in radiology, aggregate metrics flatter models that do nothing, and should be reported against that floor.

0.32