CS Paper Radar

Efficient Noise Context-Aware Representation for Low-Dose CT Denoising

Minwoo Yu, N. Robert Bennett, Jongduk Baek, Adam S. Wang

cs.CV physics.med-ph ·submitted 2026-08-11 00:57 UTC · v2
code/data

Abstract

While deep learning-based denoising has become widely adopted in low-dose CT, conventional models use generic architectures designed for natural images, failing to account for non-stationary and spatially correlated CT noise characteristics. To address this, we propose an Efficient Noise COntext-aware REpresentation (ENCORE) framework that explicitly leverages CT noise characteristics and anatomical features. First, we reformulate the noise synthesis procedure based on a realistic noise distribution beyond the conventional Gaussian approximation, establishing a rigorous foundation for training pair generation. Next, we extract local noise power and correlation contexts to guide the denoising process. To fully leverage the potential of noise context, we propose a FlyingConv module, which adaptively changes convolution weights for each local image region. Notably, our approach demonstrates substantial gains in both denoising quality and computational efficiency. Furthermore, manipulating the intensity of the noise context maps at inference time enables zero-shot conditional denoising, allowing for dynamic control over the output image texture. The entire pipeline is available at https://github.com/minwoo-yu/ENCORE.git

Closest papers

Nearest neighbours by meaning across the whole index.

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.71
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14

Noise2Match: Self-Supervised Low-Dose CT Denoising via Adaptive Inter-Slice Matching

cs.CV ·2026-10-13 ·Langrui Zhou, Guang Li, Xinyu Huang, Ziteng Zhou, Zuyang Huang +3 more
top venue similarity 0.68
Abstract

With the rapid development of deep learning, supervised convolutional neural network methods have greatly improved the performance of low-dose computed tomography (CT) denoising. However, they require paired noisy-clean training data, which is difficult to obtain in practice. Some classic self-supervised denoising methods rely on the assumption of pixel-wise independent noise, making them ineffective for correlated noise in low-dose CT (LDCT) images. Considering the high similarity and weaker noise correlation between adjacent CT slices, several recently proposed self-supervised methods use adjacent LDCT slices for training. Nevertheless, these approaches fail to effectively account for the non-rigid misalignment between slices caused by anatomical variation, hindering them from satisfying the equal-mean condition required by the classic Noise2Noise framework. In this paper, we propose Noise2Match, a self-supervised LDCT denoising method based on adaptive inter-slice matching. Noise2Match introduces an inter-slice matching network to model the label transition process between adjacent slices, and then applies correction to the denoiser's outputs to better satisfy the equal-mean condition. We theoretically prove that, under idealized conditions, training Noise2Match using adjacent LDCT slices is equivalent to supervised training with paired noisy-clean images. We further find that Noise2Match can also effectively perform low-dose conebeam CT (CBCT) denoising, which could be attributed to its correction operation that reduces inter-slice noise correlation. To the best of our knowledge, Noise2Match is the first effective image-domain self-supervised method for low-dose CBCT. Extensive experiments demonstrate that Noise2Match outperforms existing image-domain selfsupervised methods, offering broader applicability and higher practical value.

0.33

A deep dictionary network-based foundation model for ultra-low-dose CT denoising

eess.IV cs.CVcs.LG ·2026-09-11 ·Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu +1 more
similarity 0.66
Abstract

Ultra-low-dose computed tomography (ULDCT) reduces radiation exposure but suffers from severe noise that degrades diagnostic image quality. Existing deep learning-based denoising methods are typically trained in an organ-specific fashion, resulting in limited generalization across heterogeneous multi?organ imaging scenarios. Foundation models present a promising all-in-one paradigm for unified multi-organ denoising. However, their architectures suffer from poor interpretability and rely on heuristic training strategies. To address these limitations, we propose an architecture?interpretable foundation model based on the deep dictionary network (DDN) for unified multi-organ ULDCT denoising. Inspired by multilayer sparse representation theory, DDN cascades convolutional sparse coding layers with iterative soft-thresholding, providing inherent architectural interpretability. Furthermore, a dynamic dictionary module and a threshold generation module are embedded within each layer to enhance representation ability. We conduct DDN pre-training on more than one million multi-organ normal-dose CT images by recovering clean images from Gaussian-noised inputs. Sparse regularization is additionally imposed on latent feature representations, guiding the network to learn compact and noise-robust priors. The complete architecture is jointly fine-tuned on multi-organ ULDCT datasets, enabling a single unified model to perform denoising across diverse anatomical regions. Extensive experiments validate that our proposed method achieves state-of-the?art performance and consistently surpasses competing ULDCT methods across all mul

0.28

One Step Is Optimal: Unconditional Rectified Flows as Noise2Noise Denoisers for Low-Dose CT

cs.CV ·2026-09-15 ·Timothy Sereda, Debesh Jha
benchmark similarity 0.65
Abstract · 15 pages, 3 figures

We study rectified flows for denoising without clean training targets. For an unconditional rectified flow trained on Noise2Noise pairs, the optimal velocity field yields the minimum mean squared error (MMSE) denoiser in one step. In a jointly Gaussian model, we show that integrating the flow before applying its denoising readout increases error with integration time. The flow transports between noisy distributions, so its endpoint is not a clean-image estimate. Experiments on low-dose CT and Gaussian-corrupted natural images follow this pattern: one-step flow performs similarly to direct regression on the same pairs, whereas additional Euler steps reduce PSNR. A direct regressor using spatially separated, similar patches gives our best label-free CT result, a $1.99$\,dB gain over the noisy input. We report these results in CTDenoiser, a benchmark covering five architectures, supervised and self-supervised training, and two per-image methods. Supervised CNNs gain about $4$\,dB, while label-free performance depends strongly on how training pairs account for correlated CT noise. A channelized Hotelling observer also shows that fidelity gains need not improve lesion detectability: detectability falls at $160$\,HU despite higher PSNR and SSIM, while changes at $40$--$80$\,HU are small. Code, model definitions, and data-loading utilities will be released publicly; the repository link is withheld for anonymous review.

0.31

Physics-Driven Independent Pair Generation for Iterative Self-Supervised Low-Dose CT Denoising

cs.CV ·2026-09-01 ·Xianlei Han, Shaoyu Wang, Jiancheng Fang, Weiwen Wu, Qiegen Liu
similarity 0.64
Abstract · 10 pages, 11 figures, 3 tables. Includes a 1-page appendix. Submitted to IEEE Transactions on Circuits and Systems for Video Technology

Low-dose computed tomography (LDCT) measurements contain mixed Poisson-Gaussian noise. However, most self-supervised methods rely on generic image statistics and do not explicitly model this noise, which may limit their ability to effectively suppress realistic LDCT noise. To address this issue, we propose a physics-driven framework with cross-domain iteration for self-supervised LDCT denoising. The proposed framework proceeds in three main steps. First, a learned sinogram prior and the LDCT noise model guide posterior inference of photon counts, enabling separation of the Poisson and Gaussian components. Second, the separated Poisson and Gaussian components are respectively processed by binomial thinning and Gaussian data thinning to construct two branches, and residual scaling matches each branch's noise level to that of the observation, yielding a training pair with approximately independent noise realizations from one low-dose measurement. Finally, the pair is used to train an image-domain network whose forward-projected outputs update the prior. Through cross-domain iteration, the prior and the training pair are progressively refined while maintaining consistency with CT acquisition physics. Experiments on simulated data from AAPM, LIDC-IDRI, and LoDoPaB-CT and on real LDCT data show consistent gains over the evaluated self-supervised baselines across dose levels, with performance comparable to the evaluated supervised baseline.

0.25

Fast Self-Supervised Generative CT Denoising via Few-Step Sampling

cs.CV ·2026-11-19 ·Xingyi Yao, Zhengtao Ma, Zhennong Chen
similarity 0.64
Abstract · 30 pages, 4 figures, 2 tables. Xingyi Yao and Zhengtao Ma contributed equally to this work. Zhennong Chen is the corresponding author

Low-dose and thin-slice computed tomography (CT) images suffer from elevated noise that obscures anatomical detail, while clean references for supervised denoising are often unavailable. Although Noise2Noise permits self-supervised training from noisy pairs, direct regression tends to oversmooth fine structure. Averaging multiple independently generated samples mitigates this blur, though repeating multi-step diffusion sampling is costly. We introduce Noise2Noise with Improved Mean Flow (N2N-iMF) to accelerate this process via few-step sampling. N2N-iMF learns to generate one noisy image conditioned on its paired counterpart; at inference, independent outputs are sampled and averaged to suppress noise. We evaluated image quality and sampling efficiency on simulated thin-slice brain and low-dose abdominal CT across four sampling methods and averaging counts from 1 to 20, and validated the approach on real-world photon-counting CT (PCCT) brain scans. With ten samples per conditioning input and three network evaluations per sample, N2N-iMF achieved a mean absolute error of 2.60 HU on brain CT and 14.02 HU on abdominal CT, outperforming 50-evaluation denoising diffusion implicit model (DDIM) sampling (2.91 and 14.53 HU). On the same GPU, per-output generation time dropped from 7.29 to 0.43 s. Across eight PCCT cases, N2N-iMF reached a mean gray-white matter contrast-to-noise ratio of 1.341, versus 0.916 for Noise2Noise and 1.176 for DDIM. N2N-iMF accelerates self-supervised generative CT denoising without distillation while keeping the number of averaged outputs adjustable at inference.

0.24

NoduleFlow: Automatic 3D Lung Nodule Detection and Segmentation

cs.CV ·2026-10-12 ·Giulia Romoli, Filippo Ruffini, Francesco Di Feola, Valerio Guarrasi, Matteo Tortora +1 more
similarity 0.63
Abstract

Low dose Computed Tomography (CT) is the standard imaging modality for lung cancer screening. On CT scans, lung cancer typically manifests as pulmonary nodules, whose manual identification is time-consuming and prone to observer variability, image quality limitations, and suboptimal reading conditions. Moreover, subtle temporal changes are often difficult to quantify reliably in CT scans from the same patient across follow-up examinations. Deep learning-based approaches for the automatic detection and segmentation of lung nodules have demonstrated improved accuracy and efficiency. However, most existing approaches provide only coarse region-of-interest localisation, rely on prior lesion annotations or human supervision, or treat detection and segmentation as separate tasks. In this work, we present NoduleFlow, a framework for lung nodule detection, classification, and segmentation directly from series of CT volumes. Our proposal consists of four interconnected modules and operates in an automated manner at inference time, without requiring prior lesion annotations, manual initialisation, or region-of-interest pre-selection. We further investigate whether nodule localization benefits from the propagation of candidate regions across follow-up scans through inter-scan registration fields, as opposed to conventional independent per-scan analysis. The generalisability of the framework is systematically evaluated across four independent datasets. The results underscore the potential of automated pipelines for lung nodule analysis in screening and diagnostic settings.

0.14

Practical Lossless Volumetric Medical Image Compression via Tri-plane Context Tree Learning

eess.IV cs.CV ·2026-08-14 ·Yuanchao Bai, Yifan Zhao, Kai Wang, Yuanbo Du, Jie Cheng +3 more
published similarity 0.61
Abstract

Lossless compression of volumetric medical images is of paramount importance for clinical and research applications where data fidelity is essential. Traditional compression methods are often limited in efficiency due to rigid, handcrafted models. Conversely, deep neural network (DNN)-based compression methods, while effective, demand substantial computational resources, hindering deployment in resource-constrained settings. To address these challenges, we propose a novel tri-plane context tree (TCT)-based method for lossless volumetric medical image compression that delivers high performance without relying on DNNs or external training data. To exploit intra-slice and inter-slice redundancies, we introduce a compact tri-plane context representation that decomposes complex 3D context modeling into efficient 2D modeling on three orthogonal planes. By integrating this representation with a context tree framework, we develop an input-specific TCT model employing an adaptive binary tree structure. At each tree node, the model dynamically selects from a suite of tri-plane based predictors and contextual feature extractors, enabling data-adaptive context modeling tailored to local structural characteristics. Instead of offline training, we sample a subset of the input volume to learn the TCT model by optimizing the minimum description length (MDL) through iterative construction and pruning. With the learned TCT model, each pixel retrieves its corresponding context, computes the prediction residual using the predictor dictated by the context, and performs entropy encoding based on the associated histograms. Experimental results demonstrate that the proposed method achieves compression performance on par with recent DNN-based methods on multiple datasets, while maintaining low computational cost and fast coding speeds, making it highly applicable in practice.

0.60