CS Paper Radar

Physics-Informed Implicit Neural Representations for Improved Myocardial Perfusion MRI Quantification

Christos Tsepas, Chang Yan, Maximilian Fuetterer, Sebastian Kozerke, Cian M Scannell

eess.IV cs.AIcs.LG ·submitted 2026-08-11 11:25 UTC · v1
publishedcode/data

Abstract

Quantifying myocardial perfusion from cardiac magnetic resonance (CMR) can be achieved by fitting tracer-kinetic models to the dynamic contrast-enhanced MR data. However, fitting the observed data with multi-compartment exchange models, which describe the evolution of the contrast agent in the tissue, to estimate perfusion parameters is a challenging inverse problem that is sensitive to noise and acquisition variability. Previously, physics-informed neural networks (PINNs) have been proposed as an alternative to conventional non-linear least squares fitting methods with promising results for quantitative perfusion CMR. In this work, we extend the previously proposed PINN framework with spatiotemporal implicit neural representations (INRs) to represent the MR signal as a continuous spatiotemporal function and to improve the accuracy, smoothness, and physical consistency of the PINN model. In realistic simulated CMR datasets, our proposed PINN with INRs demonstrates improved robustness and parameter estimation accuracy over the previously established methods. The code is available at https://github.com/q-cardIA/pinn-inr.

Comment
Accepted at the STACOM workshop at MICCAI, Strasbourg 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI

cs.CV ·2026-11-02 ·Yusuf A. Ozturk, Jie Zheng, Fanwei Kong
similarity 0.64
Abstract

Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

0.04

The MYOSAIQ Challenge: Myocardial Segmentation with Automated Infarct Quantification

eess.IV cs.CV ·2026-08-29 ·Olivier Bernard, William A. Romero R., Cyprien Bouton, Celia Goujat, Hang Jung Ling +22 more
top venue similarity 0.63
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:032

Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging is the modality of choice to assess myocardial infarction (MI) lesions. Nowadays MI volume quantification is not performed routinely in clinical practice. Numerous deep learning (DL) methods have been developed to automate the segmentation of the myocardium and infarct regions. However, most studies rely on relatively small datasets which typically undergo pre-processing steps to standardize images and focus on a specific phase of myocardial infarction following reperfusion therapy. These limitations have impeded the development of models that are generalizable across diverse conditions and thus suitable for routine clinical use. To advance research and establish benchmarks in generalizable learning for myocardial infarct quantification, this paper presents findings from the Myocardial Segmentation with Automated Infarct Quantification (MYOSAIQ) challenge. The dataset set up for the challenge combines 439 CMR volumes from two multicenter clinical trials, with representative data acquired in acute and chronic phases after acute MI. Data were acquired in 16 centers using MRI scanners from three different vendors. Six teams participated until the end of the challenge, employing various baseline models, data augmentation techniques, and confidence strategies. To enhance the significance of this study, we compare the challengers' results with those of fine-tuned foundation models. Our results indicate that well-designed UNet-based techniques outperform fully automatic foundation models for LGE MR segmentation. While the best methods achieve high-quality and stable delineations of the left ventricle and myocardium under various conditions, they remain improvable in accurately segmenting infarct regions.

0.55

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

eess.IV cs.CV ·2026-10-23 ·Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian +10 more
similarity 0.63
Abstract · 36 pages, 7 main figures, 2 supplementary figures. Under review at Medical Image Analysis

4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

0.21

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.63
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16

Image-Condition-Controlled Diffusion Network with Large-Scale CT Pretraining for CT-Free Attenuation Correction in Dynamic Cardiac PET

cs.CV ·2026-11-18 ·Zhejia Zhang, Scott M. Leonard, Jinkui Hao, Ryan J. Avery, Richard L. Weinberg +1 more
similarity 0.61
Abstract · 11 pages, 6 figures, 3 tables. Submitted to IEEE Transactions on Radiation and Plasma Medical Sciences

Positron emission tomography (PET) provides quantitative information on myocardial perfusion. In dynamic PET, tracer kinetics are tracked through a series of reconstructed time frames. Reliable attenuation correction is essential for accurate measurements. Clinical attenuation maps ($μ$-maps) are typically derived from computed tomography (CT), which adds radiation exposure and may introduce PET-CT misregistration due to respiratory and cardiac motion. Moreover, supervised CT-free methods rely on paired non-attenuation-corrected (NAC) PET and CT data, which are scarce, whereas large-scale unpaired CT data are more readily available. To address these challenges, we propose Large-scale Unpaired CT-Informed Diffusion (LUCID), a framework that transfers anatomical priors learned from 10,000 chest CT volumes in the public CT-RATE dataset to $μ$-map synthesis for dynamic cardiac $^{82}$Rb PET. First, a convolutional neural network (CNN) predicts an initial $μ$-map from each NAC PET frame. Second, the CT-pretrained diffusion backbone refines a low-noise perturbation of the CNN prediction through a single denoising step, conditioned on the corresponding NAC PET frame via ControlNet. Finally, frame-wise predictions are averaged voxel-wise to obtain the final $μ$-map. We further introduce the voxel-wise temporal standard deviation (TSD) to quantify inter-frame variability without requiring a reference $μ$-map. We evaluated LUCID on an in-house dataset of 102 patients and found that it achieved the best quantitative accuracy while maintaining competitive inter-frame consistency. Ablation studies showed that refinement with a diffusion backbone pretrained on in-house CT data from the training patients was less accurate than the CNN prediction alone, highlighting the importance of large-scale CT pretraining.

0.22

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.61
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Physics Informed Neural Network model for the dynamical study of Abdominal Aortic Aneurysm

cs.AI physics.flu-dyn ·2026-09-14 ·Adrián Robles Arques, Martín Ruiz Fernandez, Javier Sanchis, Miguel A. Teruel, Juan Trujillo
similarity 0.60
Abstract · 38 pages, 9 figures and 2 tables

We present the development and application of a three-dimensional Physics-Informed Neural Network (PINN) framework for the investigation of haemodynamic behaviour in the human aorta. The model incorporates a time-resolved simulation of pulsatile blood flow over a two-minute interval, enabling the extraction of pressure and velocity fields with high temporal fidelity. The mechanical stress exerted on the aortic wall was quantified through Laplace's law, with temporal averaging applied to derive representative stress distributions. This approach circumvents the computational overhead associated with conventional computational fluid dynamics (CFD) methods by eliminating mesh generation and exploiting the automatic differentiation capabilities inherent to neural networks. The proposed methodology demonstrates that PINNs can serve as an efficient and accurate alternative for modelling complex vascular flow phenomena, offering significant advantages in scalability and computational cost reduction while maintaining physical consistency.

0.20

PI-NOMT: Physics-Informed Neural Optimal Mass Transport for Brain Fluid Dynamics

cs.LG cs.AI ·2026-09-27 ·Mehmet Emin Acar, Vahit Bugra Yesilkaynak, Helene Benveniste, Gozde Unal
benchmark similarity 0.60
Abstract

Recovering hidden transport mechanisms from sparse spatiotemporal observations is a fundamental inverse problem in scientific machine learning. In brain tracer imaging, dynamic contrast-enhanced MRI (DCE-MRI) provides time-resolved measurements of tracer concentration, while the underlying velocity and source mechanisms governing tracer propagation remain unobserved. We formulate this problem as physics-informed latent-state inference, in which the transport field itself is the primary object of inference rather than an auxiliary variable used only to reconstruct observed densities. We propose Physics-Informed Neural Optimal Mass Transport (PI-NOMT), a framework that represents density, velocity, and source as continuous neural fields and combines a continuous neural density teacher, recursive differentiable advection--diffusion--source rollout, unbalanced optimal-transport regularization, and governing-equation supervision. Physical laws act as structural priors that constrain the space of admissible transport mechanisms, while observed tracer dynamics provide evidence for estimating the latent transport state. We evaluate PI-NOMT on a synthetic benchmark with known ground-truth transport and on DCE-MRI sequences from nine control rats. On the synthetic benchmark, PI-NOMT accurately recovers the prescribed velocity field, including its magnitude, direction, and integrated trajectories, rather than merely reconstructing endpoint densities. Across the nine rat datasets, the framework yields sub-percent local endpoint error, consistent physical speed scales, and low post-training PDE and incompressibility residuals. These results support physics-informed latent-state inference as a general framework for recovering hidden transport mechanisms from observed dynamic scalar fields.

0.28