CS Paper Radar

Beyond Local Power: Functional Connectivity Analysis for Subject-Independent Learning Style Recognition

Wiga Maulana Baihaqi, Indriana Hidayah, Sri Kusrohmaniah, Noor Akhmad Setiawan

cs.LG q-bio.NCeess.SP ·submitted 2026-08-12 12:35 UTC · v1
published

Abstract

Identifying individual learning styles optimizes pedagogical efficacy. While traditional questionnaires are structured, behavioral tracking methods require prolonged interaction log accumulation. To overcome these temporal constraints, this paper proposes an objective Electroencephalography (EEG) approach evaluating Phase Locking Value (PLV) connectivity against localized features across the Active-Reflective (AR) and Verbal-Visual (VV) Felder-Silverman dimensions. EEG signals were recorded from 28 participants during Raven's Advanced Progressive Matrices tasks. Support Vector Machine classification used Leave-One-Subject-Out Cross-Validation (LOSO-CV) alongside a 70:30 intra-subject split. The VV dimension achieved 70.00% subject-level accuracy driven by distinct fronto-occipital polarization. Conversely, the AR dimension yielded lower cross-subject generalizability (55.56%) due to overlapping executive networks and a "Systematic Neural Inversion" phenomenon, where stable individual connectivity signatures operated diametrically opposed to global boundaries (up to 20-0 voting margins). Ultimately, these outcomes demonstrate that rigid "one-size-fits-all" classifiers are bounded by biological diversity, emphasizing the need for future adaptive feature transformation techniques to bridge the cross-subject generalization gap.

Comment
7 pages, 5 figures. Accepted for publication at 4th IEEE International Conference on Artificial Intelligence and Mechatronics Systems 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Decoding Imagined Speech: A Strictly Subject-Independent Approach Using EEG

cs.AI ·2026-09-24 ·Frederik Møllskov Trier, Xiaopeng Mao, Sadasivan Puthusserypady
similarity 0.64
Abstract

Imagined speech decoding from electroencephalography (EEG) has gained increasing attention as a potential communication pathway for individuals with severe motor impairments, yet reported performance often relies on evaluation protocols that do not clearly reflect cross-subject generalization. This study presents a transparent baseline investigation of a multi-class imagined speech EEG dataset under a strictly subject-independent evaluation framework. Two preprocessing and feature extraction pipelines were compared: a time-domain statistical feature approach and a frequency-domain spectral bandpower approach, evaluated using subject-wise cross-validation and trial-level majority voting with a random forest classifier. The spectral pipeline achieved a significantly higher mean trial-wise accuracy than the statistical pipeline (49.03 $\pm$ 4.18% vs. 37.97 $\pm$ 3.79%) for coarse-level classification across subjects. Forward feature selection further indicated that a limited subset of frequency bands captured most of the discriminative information. Overall, this work provides a strong basis for future brain-computer interface studies targeting improved cross-subject generalization in EEG-based imagined speech decoding.

0.23

Motor Imagery Classification Using Hybrid Cross-Subject Class Mixup and Selective Attention

cs.LG ·2026-11-16 ·Jiwon Kim, Chae-Won Lee, Jong-Seok Lee
similarity 0.64
Abstract

Motor imagery (MI) enables a brain-computer interface (BCI) to decode movement intentions without overt movement. Hybrid electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) classification combines complementary signals, but inter-subject variability and the design of information exchange between modalities affect generalization to new subjects. We propose a framework that combines Cross-Subject Class Mixup (CSCM) with Selective Attention. CSCM aims to construct new training data to make the model robust against inter-subject variability. It independently selects EEG and fNIRS donor trials from other training subjects within the anchor class and mixes each modality while preserving the original label. Selective Attention provides an effective way to simultaneously model the temporal signal characteristics and fuse the two modalities. It retains causal temporal self-attention for EEG and uses a classification token (CLS) to integrate both modalities, without fNIRS attention updates or direct cross-modal temporal-token attention. Leave-one-subject-out (LOSO) evaluation across 28 subjects on a public EEG-fNIRS dataset yields a mean balanced accuracy (BA) of 76.85% and a macro-averaged F1 score (Macro-F1) of 76.58%. The proposed model achieves the highest mean performance among five reimplemented baselines. We also examine the contributions of CSCM and Selective Attention through modality-specific mixing and donor-policy comparisons, temporal-policy comparisons, interventions on direct cross-modal paths, and component ablations.

0.11

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.63
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

Best Practices in EEG Analysis: Preprocessing, Modeling, and Machine Learning

eess.SP cs.LG ·2026-09-29 ·Parsa Razmara, Woojae Jeong, Aditya Kommineni, Raymundo Cassani, Richard Leahy +1 more
published similarity 0.62
Abstract · 38 pages, 5 figures. Chapter 16 of the 2026 monograph "Electroencephalogram Signals and Cognition," edited by Hema A. Murthy, Shrikanth Nara…

Electroencephalography (EEG) analysis requires careful choices in preprocessing, statistical modeling, and machine learning because EEG signals are highly susceptible to artifacts, volume conduction, low signal-to-noise ratio, and substantial inter-subject variability. This chapter provides a practical and methodological guide to modern EEG analysis, spanning EEG preprocessing, artifact removal, filtering, bad-channel detection and interpolation, re-referencing, independent component analysis (ICA), and preprocessing of simultaneous EEG-fMRI recordings. We review major approaches for computational EEG analysis, including event-related potentials (ERPs), time-frequency analysis, functional and effective connectivity, source localization, multivariate decoding, permutation testing, and multiple-comparison correction. We then examine machine-learning methods for EEG, from feature-based classifiers to deep learning and emerging EEG foundation models, with emphasis on cross-subject generalization, limited-data regimes, data leakage, evaluation metrics, and fair benchmarking. Reproducibility is treated as a core requirement throughout, including transparent preprocessing, BIDS-EEG data organization, standardized derivatives, preservation of raw data, and FAIR data practices. The chapter is intended as a practical reference for researchers developing reliable, interpretable, and reproducible EEG analysis and machine-learning pipelines.

0.47

Representational and Functional Robustness to Electrode Montages in EEG Foundation Models

cs.LG ·2026-09-28 ·Jakob Steglich, Justus Meyer zu Bexten, Shakiba Moradi, Laure Ciernik, Simon M. Hofmann +1 more
similarity 0.62
Abstract · 17 pages, 9 figures

EEG foundation models (EEG-FMs) are intended to generalize across different datasets by learning representations that, ideally, are invariant to dataset-specific EEG configurations such as electrode montages. However, EEG-FMs that accept different montages as input do not guarantee that representations and predictions remain stable across different electrode configurations, especially outside the training setting. In this work, we investigate the effects of different electrode montages through a joint functional and representational analysis of four EEG foundation models selected to span distinct montage-handling designs. We evaluate embeddings on cross-subject resting-state eyes-open/closed and within-subject motor-imagery classification under spatially informed channel reduction. Functional robustness is tested through the generalizability of linear probes across channel counts, while representational robustness is assessed through within-subject similarity and preservation of between-subject geometry. The four models show distinct robustness profiles, and the two axes dissociate: large changes in embedding similarity need not come with comparable probe degradation, and stable embeddings can still lose downstream performance. Comparing two readouts of the same encoder further shows that aggregation, not the encoder alone, determines functional robustness: pooling into anatomically aligned regions degrades less than a learned global readout, despite being montage-invariant by construction. Montage robustness is therefore a joint property of the encoder and its aggregation, and characterizing it requires both a representational and a functional axis. Input compatibility alone is evidence for neither.

0.44

Automating Learner Assessment: Benchmarking Machine Learning and Deep Learning Models for EEG-Based Familiarity Prediction

eess.SP cs.HCcs.LG ·2026-08-17 ·Isuru Nanayakkara, Thilina Halloluwa
benchmark similarity 0.61
Abstract

Objective assessment of learning remains a fundamental challenge in education. Electroencephalography (EEG) provides a direct, non-invasive window into the neural correlates of knowledge acquisition, including cognitive familiarity. This study benchmarks fifteen machine learning (ML) and deep learning (DL) models for EEG-based familiarity prediction across two cognitive domains: faces (factual knowledge) and mathematical equations (conceptual knowledge). Using continuous EEG data from 23 participants, we extract spectral features (Power Spectral Density) across six frequency bands. We show that while standard stratified cross-validation yields artificially high classification performance (up to 0.9853 F1-score using CNN) due to temporal leakage across neighboring epochs, a rigorous trial-independent validation (Group K-Fold) drops the peak performance to 0.6038 F1-score (using CNN), which is still statistically significant above the 25% chance level. This highlights the critical necessity of trial-independent evaluation to avoid overestimating model generalizability. Furthermore, feature importance and SHAP analysis reveal that temporal and frontal Gamma and Beta oscillations are the most critical biomarkers for familiarity. This work establishes a realistic benchmark for EEG-based cognitive monitoring in educational technologies.

0.11

EEGBind: Detecting Source-Level Interictal Epileptiform Discharges via EEG-Centric Multimodal Binding

cs.LG cs.MMq-bio.NC ·2026-09-09 ·Muchen Li, Anglin Liu, Xuetian Gao, Ruijian Xu, Jintai Chen
top venuebenchmarkcode/data similarity 0.61
Abstract · 7 pages, 5 figures. Accepted to the 34th ACM International Conference on Multimedia (MM '26)

Source-level analysis of interictal epileptiform discharges (IEDs) is relevant to presurgical evaluation and treatment planning because it helps characterize where epileptiform activity is likely to arise. Beyond detecting whether an IED is present, this setting requires assigning IED-positive activity to clinically meaningful brain-region categories. This setting is challenging because source-region evidence in short electroencephalography (EEG) windows can be subtle, partial, and affected by subject variability, class imbalance, and imperfect multimodal context. We present EEGBind, an EEG-centric multimodal binding framework for five-class source-level IED classification. EEGBind treats EEG as the primary modality and binds synchronized video-context features around an EEG-centric representation. Instead of relying on early or overly strong multimodal fusion, which may perturb the source-sensitive EEG representation, EEGBind uses video context as auxiliary evidence for robust classification. A view-consistent repair stage is further used to improve hidden-set robustness while preserving the learned source-class boundary. On the NeuroMM 2026 Grand Challenge Track 3 NMM-Source-IED benchmark, EEGBind achieves 0.8395 on weighted-F1 and outperforms strong competitors. These results support EEG-centric multimodal binding as a practical strategy for source-level IED classification. The open-source code is available at https://github.com/HKUSTGZ-ML4Health-Lab/NeuroMM2026_IED_Detection.

0.55

A Proof-of-Concept Study of Weakly Supervised Labeling of Fine-Grained EEG Components for Artifact Attenuation

cs.LG eess.SP ·2026-10-07 ·Lu Wang-Nöth, Hai Huang, Philipp Heiler, Shuqiong Wu, Liyun Zhang +1 more
similarity 0.61
Abstract

Electroencephalography (EEG) is highly susceptible to electromyographic (EMG) artifacts, whose temporal heterogeneity and spatial-spectral overlap with neural activity can leave mixed sources after blind source separation. Existing artifact-removal methods are further limited by scarce reliable component-level ground truth: expert annotations are costly and subjective, while no established method provides realistic simulation-based ground truth for EMG contamination in multichannel scalp EEG. To address these limitations, we propose a framework combining a frequency-aware high-dimensional representation with Multi-Instance Learning. The representation unfolds separated components into frequency-resolved intra-components, creating a space in which mixed neural and muscular activity becomes more separable, while the weakly supervised learning formulation enables artifact-likelihood scores for individual intra-components to be learned from epoch-level labels without finer-grained ground truth. The resulting intra-component classifier supports fine-grained EMG artifact detection and score-guided attenuation. Experiments on held-out subjects show that the framework learns informative intra-component scores and reduces artifact-related spectral deviations most clearly for jaw tension, with moderate effects for raising eyebrows and limited effects for frowning.

0.12