CS Paper Radar

Apnea Burden-Guided Framework: Enhancing Out-of-Distribution Generalization in PPG-Based Sleep Apnea Characterization

Mantas Rinkevičius, Oskar Pfeffer, Amal Alissa, Nando Hegemann, Vaidotas Marozas

eess.SP ·submitted 2026-08-12 16:27 UTC · v1
published

Abstract

Sleep apnea is a common sleep-related breathing disorder associated with substantial cardiovascular and metabolic risk. Although overnight polysomnography remains the reference standard for diagnosis, its complexity and cost limit its suitability for long-term preventive monitoring at home. In wearable systems, arterial blood oxygen saturation (SpO2) is commonly used as the main predictor, whereas additional morphological features of the photoplethysmographic (PPG) pulse wave are usually underexplored. This study proposes a novel apnea burden prediction-based framework for sleep apnea severity assessment and investigates the influence of PPG features on model performance and out-of-distribution (OOD) generalization. The proposed framework first predicts apnea burden as a continuous measure, which is subsequently converted into the clinically relevant apnea-hypopnea index for subject-level classification into four severity groups in both in-distribution (ID) and OOD data. Three artificial neural network architectures were evaluated, and the performance metrics were averaged over five independent runs with different fixed random seeds. During OOD testing, the combination of PPG features and SpO2 led to increases of approximately 15.72% in macro-sensitivity, 9.22% in macro-accuracy, 16.01% in macro-F1-score, 11.08% in Cohen's kappa, and 13.22% in Matthews correlation coefficient, compared with using SpO2 alone. The low-complexity convolutional-recurrent models achieved the highest overall performance. The results indicated that the proposed apnea burden-guided framework, combined with PPG features and SpO2, improves sleep apnea characterization while showing encouraging OOD performance on an independent external dataset. Moreover, simpler hybrid architectures demonstrated strong potential for robust home-based preventive monitoring.

Comment
16 pages, 13 figures, 4 tables, 53 references. Submitted to the IEEE Access journal

Closest papers

Nearest neighbours by meaning across the whole index.

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.68
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

From real to synthetic: PSG-GAN learns sleep apnea signal dynamics for AI training

cs.AI cs.LGphysics.med-ph ·2026-11-18 ·Riku Huttunen, Samu Kainulainen, Matias Rusanen, Sami Myllymaa, Juha Töyräs +2 more
code/data similarity 0.63
Abstract · 23 pages, 9 figures

Synthetic polysomnography (PSG) data has great potential in healthcare applications, for example in substituting real data that is sensitive and challenging to collect. Previous research on synthetic PSG data has been largely focused on short segments of individual signals, overlooking the inter-signal dynamics related to sleep disorders. In this study, we developed a generative adversarial network (PSG-GAN) for co-synthesizing longer segments of multiple PSG signals with diverse and complex characteristics typical of obstructive sleep apnea (OSA). The synthetic signals appeared realistic, and the electroencephalography and electrooculography band powers were similarly distributed across sleep stages. Moreover, the PSG-GAN learned to mirror signal interactions such as changes in photoplethysmography-based heart rate during and after breathing obstructions. An automatic scoring model trained solely with automatically scored synthetic signals reached good performance on sleep staging (\k{appa}=0.71 and 0.63) and respiratory event segmentation (\k{appa}=0.57 and 0.60), on two test sets consisting of healthy volunteers and OSA patients, respectively. This demonstrates the potential of synthetic data in supporting algorithm development for sleep diagnostics. The source code is available at https://github.com/rikuhuttunen/psg-gan.

0.45

Spectral Features Dominate BCG Respiratory-Event Detection: A Large-Scale Patient-Independent Comparison of Feature Groups in Sleep Apnea Patients

cs.LG ·2026-08-28 ·Israel Campero Jurado, Zoe Bousraou, Lara Benning, Sara Padilla Neira, Alexander Breuss +3 more
similarity 0.63
Abstract · 36 pages, 7 figures

Unobtrusive ballistocardiographic (BCG) sensing is a promising modality for long-term sleep-apnea monitoring, yet it remains unclear which signal features are most discriminative for respiratory-event detection. We present a literature-guided, patient-independent comparison of ten BCG feature groups using a 512-sensor capacitive pressure mat recorded simultaneously with respiratory polygraphy in 155 patients (52 female, 103 male) undergoing in-hospital evaluation for obstructive sleep apnea. Features were extracted from six spatially distinct signal channels, yielding a 191-dimensional feature vector spanning general statistical, time-domain, frequency-domain, wavelet, frame-energy, and nonlinear complexity descriptors. Under strict leave-one-patient-out cross-validation for binary classification of respiratory-event windows versus event-free reference windows, Random Forest and Histogram Gradient Boosting achieved AUC-ROC of 0.967 and 0.969 and AUC-PR of 0.977 and 0.979, respectively. Feature-importance analysis revealed that frequency-domain features dominate discrimination: breathing-band power in the 0.1-0.4 Hz range accounted for 30.3% of total discriminative information across all spatial channels, and Fast Fourier Transform spectral-shape descriptors of the adaptively preprocessed channel contributed a further 15.1%. AUC and curve-length features provided the main complementary time-domain evidence (21.5%), whereas wavelet-derived and nonlinear features contributed smaller secondary effects (10.4% combined across 59 features). Frequency-domain and time-domain features together accounted for 67% of total discriminative information, demonstrating that a compact, interpretable subset of the full feature library achieves clinically relevant performance under patient-independent validation and providing an empirical basis for feature selection in future BCG systems.

0.26

Learning transferable human physiology from two million hours of sleep with SleepFM-2

cs.AI ·2026-09-06 ·Rahul Thapa, Christopher Sun, William Theodor Lehn-Schioler, Sophia Claire Kivelson, Umaer Hanif +12 more
similarity 0.62
Abstract

Sleep provides a nightly window into health by capturing coordinated activity across the brain, heart, muscles and respiratory system. We introduce SleepFM-2, a sleep foundation model developed and evaluated on 282,511 polysomnography recordings from 26 cohorts, including 235,865 used for pretraining. These data span more than two million hours of multimodal physiology. Compared with SleepFM, SleepFM-2 improves disease prediction and sleep scoring, supports arousal, limb movement and respiratory event detection, and transfers to wearable sensing and subjective sleep phenotypes. A model combining its PSG representation with age, sex and BMI met a prespecified discrimination and significance criterion for 188 subsequently recorded EHR phenotypes in two held-out cohorts, including one health system unseen during pretraining. SleepFM-2 also outperformed a 480-feature baseline derived from the same recordings. Its disease scores revealed a reproducible principal component associated with reduced sigma-band spatial coupling and increased hypnodensity entropy. The frozen encoder performed within the observed range of expert scorers for sleep events and transferred to wakeful EEG, headband and in-ear EEG, wrist PPG and wrist accelerometry. It improved sleep staging across six accelerometry cohorts and achieved disease-prediction performance in UK Biobank similar to models pretrained directly on accelerometry. Finally, SleepFM-2 captured aspects of subjective sleep not recovered by conventional PSG summaries, particularly reports of the recorded night. These results show that multimodal sleep physiology can provide a transferable representation of human health across diseases, clinical tasks, sensors and subjective experience.

0.08

Towards Explainable Sleep Stage Classification using Single-Channel Electroencephalogram

cs.AI eess.SP ·2026-11-13 ·Gurinder Kaur Sandhu, Jude Koenig, Ankita Shukla, Shruti Kshirsagar
benchmark similarity 0.62
Abstract · 8 pages, 4 figures. Accepted at AgIA4BioHealth Workshop, IEEE BIBM 2026, Dallas, Texas, December 1-4, 2026

Automated sleep staging has achieved strong bench- mark accuracy; however, clinical adoption remains limited due to a lack of interpretability. In this work, we fill the research gap by extending the SleepXAI sleep staging framework to systematically compare five different XAI methods. Further, attribution fidelity is evaluated using Spearman rank correlation with AASM-defined EEG frequency bands, serving as clinically grounded reference signals. In this paper, we focus on single- channel Electroencephalogram (EEG), which is more amenable to practical clinical deployment compared to full polysomnography setups. Experiments are conducted on the Sleep-EDF benchmark dataset and the DREAMT dataset. In DREAMT, we stratified subjects based on OSA into four Apnea-Hypopnea Index (AHI) severity groups. We observed that the SleepXAI model achieves strong classification performance on both datasets. Among the evaluated methods, Integrated Gradients (IG) consistently achieves the highest mean attribution fidelity across all five sleep stages on Sleep-EDF and across all AHI groups on DREAMT, outperforming all other evaluated methods under the Spearman rank correlation metric. These findings highlight the importance of attribution method selection as a key factor for ensuring reliable and clinically interpretable automated sleep staging systems.

0.22

Comparative Analysis of State-of-the-Art Foundation Models for Sleep Analysis Under Channel Reduction

eess.SP cs.LG ·2026-08-14 ·Hassan Mehdi, Riku Klen, Ayse Kosal Bulbul, Suzanne Timmons, Abdulhamit Subasi +3 more
similarity 0.59
Abstract

Automatic sleep staging from polysomnography (PSG) is a well-studied task, but PSG itself is expensive, clinic-based, and burdensome to manually score, which limits its use for long-term or at-home monitoring. Most existing sleep-staging foundation models are evaluated using the full PSG montage. We instead ask how much of that montage is actually necessary. We evaluate six sleep staging models on the Multi-Ethnic Study of Atherosclerosis (MESA) PSG dataset across three signal conditions: electroencephalography (EEG), electrocardiography (ECG), and their combination (EEG+ECG). This is motivated by edge-cloud deployment, where EEG requires a clinic-grade scalp electrode, whereas ECG is already captured by consumer wearables. We test state-of-the-art foundation models such as SleepFM with an encoder trained from scratch on MESA, alongside BIOT, MOMENT, LaBraM, a base-scale Vision Transformer (ViT-B) reimplementation of SensorLM trained from scratch, and YASA, spanning EEG-pretrained, general-time-series, from-scratch, and classical non-learned approaches. No model architecture is modified from its original form; SensorLM's encoder is reimplemented only in PyTorch. For EEG-only staging, BIOT achieves the best result with a macro~F1 of 0.7237, followed by LaBraM (0.6835) and SleepFM from scratch (0.6582). Across the five models capable of ECG-only staging, switching from EEG to ECG costs between 0.2798 (MOMENT) and 0.4151 (BIOT) macro~F1, averaging 0.3531, while cutting the raw channel data rate to a third. Adding ECG to EEG provides no gain for most models. These results show that EEG carries most of the sleep-staging signal, quantify the consistent accuracy cost of the wearable-compatible alternative, and demonstrate that sleep-relevant pretraining transfers well to MESA.

0.04

ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health

eess.SP cs.LG ·2026-10-16 ·Donglin Xie, Qingshuo Zhao, Songchi Zhou, Haoyu Wang, Jingyu Wang +3 more
similarity 0.58
Abstract

Conventional sleep staging provides a coarse-grained representation that obscures within-stage depth variation. We developed ECG-SDI, a single-lead electrocardiography (ECG) framework for continuous sleep-depth profiling and digital biomarker extraction. Using 12,392 overnight polysomnographic recordings, we trained and validated a two-stage deep learning model supervised by conventional sleep-stage labels. Correlations with ordered stages excluding rapid eye movement (REM) sleep were 0.828 in the pooled internal test set and 0.848 in the external Cleveland Family Study; corresponding REM classification AUROCs were 0.954 and 0.977. Overnight trajectories captured within-stage variation. Biomarker-based phenotyping identified a disturbed subtype associated with poorer subjective sleep quality and higher all-cause mortality in the Sleep Heart Health Study (adjusted hazard ratio, 1.20; 95% CI, 1.05-1.38). Among 507 participants with paired recordings before and after continuous positive airway pressure (CPAP), normalized sleep-depth area increased by 6.1% and shallow-sleep burden below 0.3 decreased by 16.0%. Exploratory analyses linked reductions in approximate entropy and depth variability to reduced oxygen desaturation and increased sleep efficiency, respectively (Spearman rho = 0.24 and 0.12); both associations remained positive after covariate adjustment. Mean ECG-SDI within N2 increased by 0.017 (95% CI, 0.004-0.030). A wearable proof-of-concept illustrated the acquisition-to-report workflow. These findings support ECG-based sleep phenotyping and further evaluation of CPAP response monitoring at home.

0.13

Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical Translation

cs.ET cs.LG ·2026-11-12 ·Karthika Shalini Potail, Harshitha Manjunatha, Hetvi Kotadia, Tooraj Nikoubin
surveybenchmark similarity 0.58
Abstract

Continuous blood pressure (BP) monitoring could improve hypertension management by capturing changes that intermittent cuff measurements miss. Photoplethysmography (PPG) is widely explored for cuffless BP estimation because optical sensors are inexpensive, wearable, and already present in many consumer and clinical devices. PPG, however, does not measure arterial pressure: BP is inferred from waveform characteristics or pulse timing, which also depend on vascular tone, arterial stiffness, sensor contact, motion, and individual physiology. This survey reviews PPG-based cuffless BP estimation along the full measurement chain, covering physiological mechanisms, waveform features, pulse arrival time (PAT), pulse transit time (PTT), machine-learning methods, datasets, calibration, validation, deployment, bias, and clinical translation. Studies are assessed by the strength of evidence they provide rather than by reported error alone, with particular attention to subject and temporal leakage, dataset imbalance, calibration dependence and drift, motion artifacts, and the gap between benchmark accuracy and reliable real-world measurement. The review finds that progress depends on more than better prediction algorithms. Future work should prioritize physiologically informed models, diverse longitudinal datasets, transparent reporting of calibration requirements and failure rates, stronger evaluation protocols, and studies that demonstrate practical value in clinical care.

0.10