CS Paper Radar

Spectral Features Dominate BCG Respiratory-Event Detection: A Large-Scale Patient-Independent Comparison of Feature Groups in Sleep Apnea Patients

Israel Campero Jurado, Zoe Bousraou, Lara Benning, Sara Padilla Neira, Alexander Breuss, Robert Riener, Esther Irene Schwarz, Elisabeth Wilhelm

cs.LG ·submitted 2026-08-28 11:56 UTC · v2

Abstract

Unobtrusive ballistocardiographic (BCG) sensing is a promising modality for long-term sleep-apnea monitoring, yet it remains unclear which signal features are most discriminative for respiratory-event detection. We present a literature-guided, patient-independent comparison of ten BCG feature groups using a 512-sensor capacitive pressure mat recorded simultaneously with respiratory polygraphy in 155 patients (52 female, 103 male) undergoing in-hospital evaluation for obstructive sleep apnea. Features were extracted from six spatially distinct signal channels, yielding a 191-dimensional feature vector spanning general statistical, time-domain, frequency-domain, wavelet, frame-energy, and nonlinear complexity descriptors. Under strict leave-one-patient-out cross-validation for binary classification of respiratory-event windows versus event-free reference windows, Random Forest and Histogram Gradient Boosting achieved AUC-ROC of 0.967 and 0.969 and AUC-PR of 0.977 and 0.979, respectively. Feature-importance analysis revealed that frequency-domain features dominate discrimination: breathing-band power in the 0.1-0.4 Hz range accounted for 30.3% of total discriminative information across all spatial channels, and Fast Fourier Transform spectral-shape descriptors of the adaptively preprocessed channel contributed a further 15.1%. AUC and curve-length features provided the main complementary time-domain evidence (21.5%), whereas wavelet-derived and nonlinear features contributed smaller secondary effects (10.4% combined across 59 features). Frequency-domain and time-domain features together accounted for 67% of total discriminative information, demonstrating that a compact, interpretable subset of the full feature library achieves clinically relevant performance under patient-independent validation and providing an empirical basis for feature selection in future BCG systems.

Comment
36 pages, 7 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Sleep Sound Event Detection Powered by Learnable Multi-Resolution Adaptive Line Enhancer

cs.SD ·2026-10-11 ·Chanwoo Park, Chanwoo Kim
top venue similarity 0.64
Abstract · Accepted to Interspeech 2026 (Long paper track)

Sleep-disordered breathing, including snoring, hypopnea, and obstructive apnea, is the hallmark of obstructive sleep apnea, whose severity is quantified by the Apnea-Hypopnea Index (AHI). As conventional polysomnography is costly and clin- ically demanding, microphone-only detection has emerged as a noninvasive alternative for screening. We propose ALE- Confidence Fusion Sound Event Detection (ACF-SED), the first framework that directly injects the per-frame confidence map of an Adaptive Line Enhancer (ALE) into Transformer atten- tion biasing and feature modulation, rather than as mere pre- processing. A Multi-Resolution ALE Bank aggregates three parallel NLMS filters at distinct decorrelation delays, while a Confidence-Guided Cross-Path block couples event and noise streams via gated cross-attention. On the Audio-Polygraphy Dataset for Sleep Apnea Analysis, ACF-SED achieves state- of-the-art detection across Event-F1, Segment-F1, and PSDS, enabling end-to-end AHI estimation.

0.35

Apnea Burden-Guided Framework: Enhancing Out-of-Distribution Generalization in PPG-Based Sleep Apnea Characterization

eess.SP ·2026-08-12 ·Mantas Rinkevičius, Oskar Pfeffer, Amal Alissa, Nando Hegemann, Vaidotas Marozas
published similarity 0.63
Abstract · 16 pages, 13 figures, 4 tables, 53 references. Submitted to the IEEE Access journal

Sleep apnea is a common sleep-related breathing disorder associated with substantial cardiovascular and metabolic risk. Although overnight polysomnography remains the reference standard for diagnosis, its complexity and cost limit its suitability for long-term preventive monitoring at home. In wearable systems, arterial blood oxygen saturation (SpO2) is commonly used as the main predictor, whereas additional morphological features of the photoplethysmographic (PPG) pulse wave are usually underexplored. This study proposes a novel apnea burden prediction-based framework for sleep apnea severity assessment and investigates the influence of PPG features on model performance and out-of-distribution (OOD) generalization. The proposed framework first predicts apnea burden as a continuous measure, which is subsequently converted into the clinically relevant apnea-hypopnea index for subject-level classification into four severity groups in both in-distribution (ID) and OOD data. Three artificial neural network architectures were evaluated, and the performance metrics were averaged over five independent runs with different fixed random seeds. During OOD testing, the combination of PPG features and SpO2 led to increases of approximately 15.72% in macro-sensitivity, 9.22% in macro-accuracy, 16.01% in macro-F1-score, 11.08% in Cohen's kappa, and 13.22% in Matthews correlation coefficient, compared with using SpO2 alone. The low-complexity convolutional-recurrent models achieved the highest overall performance. The results indicated that the proposed apnea burden-guided framework, combined with PPG features and SpO2, improves sleep apnea characterization while showing encouraging OOD performance on an independent external dataset. Moreover, simpler hybrid architectures demonstrated strong potential for robust home-based preventive monitoring.

0.28

Learning transferable human physiology from two million hours of sleep with SleepFM-2

cs.AI ·2026-09-06 ·Rahul Thapa, Christopher Sun, William Theodor Lehn-Schioler, Sophia Claire Kivelson, Umaer Hanif +12 more
similarity 0.62
Abstract

Sleep provides a nightly window into health by capturing coordinated activity across the brain, heart, muscles and respiratory system. We introduce SleepFM-2, a sleep foundation model developed and evaluated on 282,511 polysomnography recordings from 26 cohorts, including 235,865 used for pretraining. These data span more than two million hours of multimodal physiology. Compared with SleepFM, SleepFM-2 improves disease prediction and sleep scoring, supports arousal, limb movement and respiratory event detection, and transfers to wearable sensing and subjective sleep phenotypes. A model combining its PSG representation with age, sex and BMI met a prespecified discrimination and significance criterion for 188 subsequently recorded EHR phenotypes in two held-out cohorts, including one health system unseen during pretraining. SleepFM-2 also outperformed a 480-feature baseline derived from the same recordings. Its disease scores revealed a reproducible principal component associated with reduced sigma-band spatial coupling and increased hypnodensity entropy. The frozen encoder performed within the observed range of expert scorers for sleep events and transferred to wakeful EEG, headband and in-ear EEG, wrist PPG and wrist accelerometry. It improved sleep staging across six accelerometry cohorts and achieved disease-prediction performance in UK Biobank similar to models pretrained directly on accelerometry. Finally, SleepFM-2 captured aspects of subjective sleep not recovered by conventional PSG summaries, particularly reports of the recorded night. These results show that multimodal sleep physiology can provide a transferable representation of human health across diseases, clinical tasks, sensors and subjective experience.

0.08

SemPSG: A Semantic Channel-Aware Foundation Model for Polysomnography Analysis

cs.LG ·2026-09-29 ·Junyu Chen, Chenxi Liu, Shiqin Tang, Hao Miao, Wanyun Ling +3 more
similarity 0.62
Abstract

Polysomnography (PSG) integrates multiple physiological signals to provide a comprehensive characterization of human sleep, yet its heterogeneous channel configurations across centers pose substantial challenges for transferable representation learning. Existing foundation models mainly focus on physiological modeling or temporal learning, while channel identity is often treated as a fixed structural index, overlooking the physiological semantics encoded by signal modality and reference configuration. To this end, we propose SemPSG, a Semantic channel-aware foundation model for heterogeneous PSG analysis. SemPSG explicitly represents the physiological semantics of channel identity and incorporates them into both signal representation learning and channel aggregation, enabling flexible modeling across diverse data configurations. Specifically, a semantic-conditioned time-series encoder captures signal-specific temporal dynamics and cross-signal interactions, while a multi-view image encoder extracts complementary time-frequency and morphological patterns from the same physiological recordings. We evaluate SemPSG on sleep and health-related tasks, including sleep staging, sleep-disorder breathing analysis, disease prediction, cognition and emotion recognition, and demographic estimation. Extensive experiments demonstrate consistent improvements over both general-purpose time series foundation models and PSG-specific foundation models, together with generalization across heterogeneous datasets across diverse channel configurations.

0.07

Towards Explainable Sleep Stage Classification using Single-Channel Electroencephalogram

cs.AI eess.SP ·2026-11-13 ·Gurinder Kaur Sandhu, Jude Koenig, Ankita Shukla, Shruti Kshirsagar
benchmark similarity 0.62
Abstract · 8 pages, 4 figures. Accepted at AgIA4BioHealth Workshop, IEEE BIBM 2026, Dallas, Texas, December 1-4, 2026

Automated sleep staging has achieved strong bench- mark accuracy; however, clinical adoption remains limited due to a lack of interpretability. In this work, we fill the research gap by extending the SleepXAI sleep staging framework to systematically compare five different XAI methods. Further, attribution fidelity is evaluated using Spearman rank correlation with AASM-defined EEG frequency bands, serving as clinically grounded reference signals. In this paper, we focus on single- channel Electroencephalogram (EEG), which is more amenable to practical clinical deployment compared to full polysomnography setups. Experiments are conducted on the Sleep-EDF benchmark dataset and the DREAMT dataset. In DREAMT, we stratified subjects based on OSA into four Apnea-Hypopnea Index (AHI) severity groups. We observed that the SleepXAI model achieves strong classification performance on both datasets. Among the evaluated methods, Integrated Gradients (IG) consistently achieves the highest mean attribution fidelity across all five sleep stages on Sleep-EDF and across all AHI groups on DREAMT, outperforming all other evaluated methods under the Spearman rank correlation metric. These findings highlight the importance of attribution method selection as a key factor for ensuring reliable and clinically interpretable automated sleep staging systems.

0.22

Acoustic Respiratory Phase Detection on Mobile Devices

cs.AI cs.LG ·2026-11-12 ·Julian Szymanski, Tomasz Sankowski, Piotr Sulewski, Iwo Czartowski, Javier Medina Quero
similarity 0.60
Abstract

Breathing monitoring is important for well-being, stress regulation, and guided breathing exercises, yet existing approaches often rely on contact-based sensors or controlled environments. This paper presents a non-invasive framework for respiratory phase detection using acoustic signals recorded on commodity smartphones. The proposed hybrid CNN-Transformer architecture combines local spectral feature extraction with long-range temporal modeling to capture the cyclic structure of breathing. The model is evaluated using a Leave-One-Subject-Out (LOSO) protocol on the Foundation Dataset and on an independent unseen test set comprising over 1300 breathing cycles and 2 hours of continuous recordings. The proposed 3-class formulation achieves 72.85% frame-level accuracy and 96.6% cycle-level exhalation detection efficiency in the LOSO evaluation, while achieving 76.94% frame-level accuracy, a Cohen's Kappa score of 0.65, and 99.2% cycle-level exhalation detection efficiency on the unseen test set. Results suggest that accurate respiratory monitoring may be achievable under data-constrained conditions, indicating that appropriate temporal modeling can learn transferable respiratory representations and generalize to previously unseen participants. An end-to-end ONNX deployment pipeline enables privacy-preserving on-device inference with latency below 20 ms, supporting real-time monitoring on mobile and wearable devices.

0.14

MM-Net: A Multimodal Multi-Task Network for Sleep Staging and Sleep Apnea Assessment After Ischemic Stroke

cs.LG cs.AIeess.SP ·2026-10-27 ·Md Wahiduzzaman Suva, Esm E Moula Chowdhury Abha, Md Imtiaj Alam Sajin, Md Iftekharul Mobin, Jia Uddin
similarity 0.60
Abstract

Automated polysomnography after ischemic stroke is challenging because of altered sleep-related neural activity and concurrent respiratory disturbances. Existing stroke-specific approaches mainly address sleep-stage classification, leaving joint analysis of sleep architecture and respiratory events underexplored. Moreover, adapting pretrained EEG encoders introduces a representation inconsistency when downstream models are trained on embeddings from previously seen patients but evaluated on unseen individuals. We propose MM-Net, a multimodal multi-task framework that resolves this inconsistency through cross-fitting and ridge-based embedding alignment. Sleep-adapted EEG-EOG representations and engineered neural descriptors are fused with learned cardiorespiratory features through cross-attention and shared temporal modeling for simultaneous sleep staging and respiratory-event detection. On iSLEEPS (99 patients with subacute ischemic stroke), ten-fold patient-independent evaluation achieved 76.3% staging accuracy (Cohen's $κ$ = 0.656) and 0.825 respiratory-event AUC, outperforming the evaluated baselines under matched protocols. The sleep-adapted encoder improved the downstream model when its embeddings were aligned, raising staging accuracy by 1.4 percentage points over the frozen encoder ($p$ = 0.020) versus 0.2 points without alignment. MM-Net also achieved 86.4% staging accuracy on Sleep-EDF, above every single-EEG architecture reimplemented on the same recordings, and 80.3% staging accuracy with 0.889 respiratory AUC on ISRUC-I, exceeding its retrained staging baselines. Without retraining, the iSLEEPS-trained model retained respiratory AUCs of 0.833 on ISRUC-I and 0.841 on UCD. These findings support representation-consistent neural adaptation and joint physiological modeling across stroke, healthy-sleep, and sleep-disorder cohorts.

0.25

ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health

eess.SP cs.LG ·2026-10-16 ·Donglin Xie, Qingshuo Zhao, Songchi Zhou, Haoyu Wang, Jingyu Wang +3 more
similarity 0.60
Abstract

Conventional sleep staging provides a coarse-grained representation that obscures within-stage depth variation. We developed ECG-SDI, a single-lead electrocardiography (ECG) framework for continuous sleep-depth profiling and digital biomarker extraction. Using 12,392 overnight polysomnographic recordings, we trained and validated a two-stage deep learning model supervised by conventional sleep-stage labels. Correlations with ordered stages excluding rapid eye movement (REM) sleep were 0.828 in the pooled internal test set and 0.848 in the external Cleveland Family Study; corresponding REM classification AUROCs were 0.954 and 0.977. Overnight trajectories captured within-stage variation. Biomarker-based phenotyping identified a disturbed subtype associated with poorer subjective sleep quality and higher all-cause mortality in the Sleep Heart Health Study (adjusted hazard ratio, 1.20; 95% CI, 1.05-1.38). Among 507 participants with paired recordings before and after continuous positive airway pressure (CPAP), normalized sleep-depth area increased by 6.1% and shallow-sleep burden below 0.3 decreased by 16.0%. Exploratory analyses linked reductions in approximate entropy and depth variability to reduced oxygen desaturation and increased sleep efficiency, respectively (Spearman rho = 0.24 and 0.12); both associations remained positive after covariate adjustment. Mean ECG-SDI within N2 increased by 0.017 (95% CI, 0.004-0.030). A wearable proof-of-concept illustrated the acquisition-to-report workflow. These findings support ECG-based sleep phenotyping and further evaluation of CPAP response monitoring at home.

0.13