CS Paper Radar

Sleep Sound Event Detection Powered by Learnable Multi-Resolution Adaptive Line Enhancer

Chanwoo Park, Chanwoo Kim

cs.SD ·submitted 2026-10-11 11:10 UTC · v1
top venue

Abstract

Sleep-disordered breathing, including snoring, hypopnea, and obstructive apnea, is the hallmark of obstructive sleep apnea, whose severity is quantified by the Apnea-Hypopnea Index (AHI). As conventional polysomnography is costly and clin- ically demanding, microphone-only detection has emerged as a noninvasive alternative for screening. We propose ALE- Confidence Fusion Sound Event Detection (ACF-SED), the first framework that directly injects the per-frame confidence map of an Adaptive Line Enhancer (ALE) into Transformer atten- tion biasing and feature modulation, rather than as mere pre- processing. A Multi-Resolution ALE Bank aggregates three parallel NLMS filters at distinct decorrelation delays, while a Confidence-Guided Cross-Path block couples event and noise streams via gated cross-attention. On the Audio-Polygraphy Dataset for Sleep Apnea Analysis, ACF-SED achieves state- of-the-art detection across Event-F1, Segment-F1, and PSDS, enabling end-to-end AHI estimation.

Comment
Accepted to Interspeech 2026 (Long paper track)

Closest papers

Nearest neighbours by meaning across the whole index.

Spectral Features Dominate BCG Respiratory-Event Detection: A Large-Scale Patient-Independent Comparison of Feature Groups in Sleep Apnea Patients

cs.LG ·2026-08-28 ·Israel Campero Jurado, Zoe Bousraou, Lara Benning, Sara Padilla Neira, Alexander Breuss +3 more
similarity 0.64
Abstract · 36 pages, 7 figures

Unobtrusive ballistocardiographic (BCG) sensing is a promising modality for long-term sleep-apnea monitoring, yet it remains unclear which signal features are most discriminative for respiratory-event detection. We present a literature-guided, patient-independent comparison of ten BCG feature groups using a 512-sensor capacitive pressure mat recorded simultaneously with respiratory polygraphy in 155 patients (52 female, 103 male) undergoing in-hospital evaluation for obstructive sleep apnea. Features were extracted from six spatially distinct signal channels, yielding a 191-dimensional feature vector spanning general statistical, time-domain, frequency-domain, wavelet, frame-energy, and nonlinear complexity descriptors. Under strict leave-one-patient-out cross-validation for binary classification of respiratory-event windows versus event-free reference windows, Random Forest and Histogram Gradient Boosting achieved AUC-ROC of 0.967 and 0.969 and AUC-PR of 0.977 and 0.979, respectively. Feature-importance analysis revealed that frequency-domain features dominate discrimination: breathing-band power in the 0.1-0.4 Hz range accounted for 30.3% of total discriminative information across all spatial channels, and Fast Fourier Transform spectral-shape descriptors of the adaptively preprocessed channel contributed a further 15.1%. AUC and curve-length features provided the main complementary time-domain evidence (21.5%), whereas wavelet-derived and nonlinear features contributed smaller secondary effects (10.4% combined across 59 features). Frequency-domain and time-domain features together accounted for 67% of total discriminative information, demonstrating that a compact, interpretable subset of the full feature library achieves clinically relevant performance under patient-independent validation and providing an empirical basis for feature selection in future BCG systems.

0.26

Metadata-Conditioned Audio Transformers for Adaptive Respiratory Sound Classification

cs.SD cs.AIeess.AS ·2026-11-02 ·George Kontogiannis, Pantelis Tzamalis, Sotiris Nikoletseas
publishedbenchmark similarity 0.63
Abstract

Respiratory sound classification from auscultation recordings is confounded by heterogeneous acquisition conditions, including recording device, auscultation site, and patient characteristics, that introduce systematic variability unrelated to the underlying pathology. Although such metadata is often available, existing approaches either ignore it or rely on naïve fusion strategies that do not model how distinct metadata sources influence different components of the acoustic representation. We propose a family of metadata-conditioning mechanisms for the Audio Spectrogram Transformer (AST), progressing from gated residual fusion to Feature-wise Linear Modulation (FiLM) adapted to the Transformer architecture. We further introduce two novel variants: Token-Aware FiLM (TAFiLM), which applies distinct modulation to classification and patch tokens, and Soft-Factorized FiLM (SoftFiLM), which learns soft masks to align metadata factors with disentangled feature subspaces. Experiments on the ICBHI benchmark demonstrate consistent gains across all conditioning strategies. SoftFiLM achieves 64.11% on the official 4-class task (+3.94% over the baseline) and 72.40% on the 2-class task, establishing a new state-of-the-art on the 2-class task and competitive performance on the 4-class benchmark.

0.24

Listening for Airway Stenosis: A Foundation Model-Based Method for Rapid and Accessible Detection

cs.SD ·2026-09-14 ·Jean Groeninger, Zihao Zhao, Juliana de Castilhos, Sven Nebelung, Daniel Truhn
code/data similarity 0.62
Abstract · Jean Groeninger and Zihao Zhao contributed equally. Code is available at https://github.com/JeanGrng/listening-for-airway-stenosis

Airway stenosis can cause severe respiratory complications, yet its detection often relies on specialized examinations and medical imaging. This study explores the potential of acoustic AI for rapid and accessible airway stenosis detection using readily acquired patient voice recordings. We systematically investigate whether acoustic foundation models (AFMs) can extract acoustic representations associated with airway stenosis-related speech patterns. Experiments are conducted on a cohort of 748 participants from the Bridge2AI-Voice dataset, 134 with airway stenosis and 614 without. The best-performing model achieves an AUROC of 0.952 and an accuracy of 0.924 (means over five-fold cross-validation), highlighting the potential of AFMs to transfer beyond general-purpose speech applications to clinical diagnostic tasks. Further analysis reveals that the model primarily relies on connected-speech recordings rather than isolated acoustic tasks, such as sustained phonation and breathing. Overall, these results suggest that voice-based acoustic AI could complement existing diagnostic workflows by enabling rapid, low-burden, and widely accessible screening for airway stenosis.

0.43

Towards Explainable Sleep Stage Classification using Single-Channel Electroencephalogram

cs.AI eess.SP ·2026-11-13 ·Gurinder Kaur Sandhu, Jude Koenig, Ankita Shukla, Shruti Kshirsagar
benchmark similarity 0.61
Abstract · 8 pages, 4 figures. Accepted at AgIA4BioHealth Workshop, IEEE BIBM 2026, Dallas, Texas, December 1-4, 2026

Automated sleep staging has achieved strong bench- mark accuracy; however, clinical adoption remains limited due to a lack of interpretability. In this work, we fill the research gap by extending the SleepXAI sleep staging framework to systematically compare five different XAI methods. Further, attribution fidelity is evaluated using Spearman rank correlation with AASM-defined EEG frequency bands, serving as clinically grounded reference signals. In this paper, we focus on single- channel Electroencephalogram (EEG), which is more amenable to practical clinical deployment compared to full polysomnography setups. Experiments are conducted on the Sleep-EDF benchmark dataset and the DREAMT dataset. In DREAMT, we stratified subjects based on OSA into four Apnea-Hypopnea Index (AHI) severity groups. We observed that the SleepXAI model achieves strong classification performance on both datasets. Among the evaluated methods, Integrated Gradients (IG) consistently achieves the highest mean attribution fidelity across all five sleep stages on Sleep-EDF and across all AHI groups on DREAMT, outperforming all other evaluated methods under the Spearman rank correlation metric. These findings highlight the importance of attribution method selection as a key factor for ensuring reliable and clinically interpretable automated sleep staging systems.

0.22

SemPSG: A Semantic Channel-Aware Foundation Model for Polysomnography Analysis

cs.LG ·2026-09-29 ·Junyu Chen, Chenxi Liu, Shiqin Tang, Hao Miao, Wanyun Ling +3 more
similarity 0.61
Abstract

Polysomnography (PSG) integrates multiple physiological signals to provide a comprehensive characterization of human sleep, yet its heterogeneous channel configurations across centers pose substantial challenges for transferable representation learning. Existing foundation models mainly focus on physiological modeling or temporal learning, while channel identity is often treated as a fixed structural index, overlooking the physiological semantics encoded by signal modality and reference configuration. To this end, we propose SemPSG, a Semantic channel-aware foundation model for heterogeneous PSG analysis. SemPSG explicitly represents the physiological semantics of channel identity and incorporates them into both signal representation learning and channel aggregation, enabling flexible modeling across diverse data configurations. Specifically, a semantic-conditioned time-series encoder captures signal-specific temporal dynamics and cross-signal interactions, while a multi-view image encoder extracts complementary time-frequency and morphological patterns from the same physiological recordings. We evaluate SemPSG on sleep and health-related tasks, including sleep staging, sleep-disorder breathing analysis, disease prediction, cognition and emotion recognition, and demographic estimation. Extensive experiments demonstrate consistent improvements over both general-purpose time series foundation models and PSG-specific foundation models, together with generalization across heterogeneous datasets across diverse channel configurations.

0.07

MM-Net: A Multimodal Multi-Task Network for Sleep Staging and Sleep Apnea Assessment After Ischemic Stroke

cs.LG cs.AIeess.SP ·2026-10-27 ·Md Wahiduzzaman Suva, Esm E Moula Chowdhury Abha, Md Imtiaj Alam Sajin, Md Iftekharul Mobin, Jia Uddin
similarity 0.58
Abstract

Automated polysomnography after ischemic stroke is challenging because of altered sleep-related neural activity and concurrent respiratory disturbances. Existing stroke-specific approaches mainly address sleep-stage classification, leaving joint analysis of sleep architecture and respiratory events underexplored. Moreover, adapting pretrained EEG encoders introduces a representation inconsistency when downstream models are trained on embeddings from previously seen patients but evaluated on unseen individuals. We propose MM-Net, a multimodal multi-task framework that resolves this inconsistency through cross-fitting and ridge-based embedding alignment. Sleep-adapted EEG-EOG representations and engineered neural descriptors are fused with learned cardiorespiratory features through cross-attention and shared temporal modeling for simultaneous sleep staging and respiratory-event detection. On iSLEEPS (99 patients with subacute ischemic stroke), ten-fold patient-independent evaluation achieved 76.3% staging accuracy (Cohen's $κ$ = 0.656) and 0.825 respiratory-event AUC, outperforming the evaluated baselines under matched protocols. The sleep-adapted encoder improved the downstream model when its embeddings were aligned, raising staging accuracy by 1.4 percentage points over the frozen encoder ($p$ = 0.020) versus 0.2 points without alignment. MM-Net also achieved 86.4% staging accuracy on Sleep-EDF, above every single-EEG architecture reimplemented on the same recordings, and 80.3% staging accuracy with 0.889 respiratory AUC on ISRUC-I, exceeding its retrained staging baselines. Without retraining, the iSLEEPS-trained model retained respiratory AUCs of 0.833 on ISRUC-I and 0.841 on UCD. These findings support representation-consistent neural adaptation and joint physiological modeling across stroke, healthy-sleep, and sleep-disorder cohorts.

0.25

Design and Architecture of Airmod: An Active Noise Cancellation and Deep Learning System for Real-Time Respiratory Rate Estimation from Tracheal Sounds

cs.SD ·2026-10-27 ·Shang-Ran Huang, Fu-Shun Hsu, Ji-Chang Huang, Chuan Chen, Shou-Zen Fan +3 more
similarity 0.57
Abstract

Tracheal auscultation is recommended by clinical practice guidelines, and required by some U.S. state regulations, for monitoring ventilation during procedural sedation and monitored anesthesia care. However, continuous auscultation with a conventional stethoscope is impractical, susceptible to ambient noise, and difficult to interpret. We developed the Artificial Intelligence Respiratory MOnitoring Device (Airmod), an FDA-cleared software as a medical device (510(k) K242798) that continuously monitors tracheal sounds and estimates breath-to-breath respiratory rate in real time. In this paper, we describe its software architecture and key processing modules. Ambient noise is suppressed by active noise control, using a normalized least-mean-square adaptive filter with a dual-microphone electronic stethoscope. A multiclass convolutional bidirectional gated recurrent unit (CNN-BiGRU) model detects inhalations and exhalations in 15-s inference windows. It was trained on HF_Tracheal_V2, a new database of 373 continuous tracheal sound recordings (8,521 min; 107,644 labeled inhalations) from 369 subjects under sedation. To handle continuous acoustic streaming, Airmod runs inference on overlapping 15-s windows. It refines the detected inhalations by removing incomplete events, low-energy false positives, and double counts, concatenates them into a history list, and estimates respiratory rate from the mean period of the last three breaths. On the test set, at the default 2-s prediction interval with refinement enabled, inhalation detection achieved a sensitivity of 0.828, a positive predictive value of 0.832, and an F1-score of 0.830. Airmod also broadcasts the noise-cancelled tracheal sound and displays a real-time spectrogram to help clinicians recognize respiratory abnormalities.

0.21

Acoustic Respiratory Phase Detection on Mobile Devices

cs.AI cs.LG ·2026-11-12 ·Julian Szymanski, Tomasz Sankowski, Piotr Sulewski, Iwo Czartowski, Javier Medina Quero
similarity 0.57
Abstract

Breathing monitoring is important for well-being, stress regulation, and guided breathing exercises, yet existing approaches often rely on contact-based sensors or controlled environments. This paper presents a non-invasive framework for respiratory phase detection using acoustic signals recorded on commodity smartphones. The proposed hybrid CNN-Transformer architecture combines local spectral feature extraction with long-range temporal modeling to capture the cyclic structure of breathing. The model is evaluated using a Leave-One-Subject-Out (LOSO) protocol on the Foundation Dataset and on an independent unseen test set comprising over 1300 breathing cycles and 2 hours of continuous recordings. The proposed 3-class formulation achieves 72.85% frame-level accuracy and 96.6% cycle-level exhalation detection efficiency in the LOSO evaluation, while achieving 76.94% frame-level accuracy, a Cohen's Kappa score of 0.65, and 99.2% cycle-level exhalation detection efficiency on the unseen test set. Results suggest that accurate respiratory monitoring may be achievable under data-constrained conditions, indicating that appropriate temporal modeling can learn transferable respiratory representations and generalize to previously unseen participants. An end-to-end ONNX deployment pipeline enables privacy-preserving on-device inference with latency below 20 ms, supporting real-time monitoring on mobile and wearable devices.

0.14