Validation of Smartphone-Based Photogrammetric 3D Body Scanning for Automated Anthropometric Measurements Compared with a Commercial Depth-Sensor-Based Body Scanner

Ruting Cheng, Boyuan Feng, Chuhui Qiu, Joaquin A. Calderon, Qing Pan, Yufan Liu, James K. Hahn

cs.CV ·submitted 2026-08-13 05:00 UTC · v1
published

Abstract

3D body scanning has become an important tool in healthcare applications because of its rapid and non-invasive nature. While smartphone-based photogrammetric reconstruction provide a low-cost and accessible alternative to commercial 3D body scanners, their performance for whole-body scanning remains insufficiently validated. Thus, we designed this study to comprehensively validate the photogrammetric 3D scanning application by evaluating automatically extracted whole-body measurements and longitudinal body-shape monitoring. We evaluated a representative application, PolyCam, against the commercial depth-sensor-based Fit3D ProScanner using 144 pregnant participants scanned longitudinally throughout pregnancy. We designed an automatic circumference extraction pipeline to get measurements at four anatomical landmarks from paired 3D scans. A linear mixed-effects model was used to evaluate scanner effects and longitudinal body-shape changes. Measurement consistency was assessed using repeated PolyCam scans and tape measurements on a rigid mannequin. PolyCam demonstrated strong agreement with Fit3D, with average biases below 16 mm, intraclass correlation coefficients above 0.8, and Pearson correlation coefficients above 0.9 across all landmarks. Both systems captured comparable longitudinal body-shape changes. Mannequin experiments showed mean biases below 3.5 mm and no significant differences from tape measurements. These findings support smartphone photogrammetry as a potential accessible alternative to commercial body scanners and applicable for longitudinal 3D body-shape assessment.

Comment
16 pages, 5 figures, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

InfantNet: A Large Scale Dataset for Infant Body Pose and Shape Estimation

cs.CV ·2026-10-29 ·Zhipeng Hui, Jiahao Wang, Xun Dong, Guofeng Zhang, Xingrui Wang +11 more
benchmark similarity 0.61
Abstract

Infant pose and shape estimation is essential for applications in childcare, developmental monitoring, and medical diagnosis. However, existing methods and datasets are largely designed for adults, and direct transfer to infants fails due to substantial differences in body proportions, articulation limits, and frequent self-occlusion. To address this gap, we introduce InfantNet, the largest real-image infant dataset to date, comprising 108,902 RGB images of infants aged 6-18 months. Each image is annotated with 2D keypoints, and a curated subset of 11,642 images additionally includes 3D pose and shape annotations with full SMIL parameters, verified through multi-view rendering and reprojection-error filtering. We use an iterative annotation pipeline to ensure high fidelity across both 2D and 3D labels. InfantNet establishes a large-scale, comprehensive benchmark for infant 2D keypoint detection and 3D pose-and-shape recovery. Baseline experiments demonstrate that state-of-the-art adult pose estimators do not generalize well to infants, whereas fine-tuning on InfantNet yields a consistent improvement. The gains are even more pronounced for 3D pose and shape estimation, where SMIL-based estimation demonstrates robust performance with accuracy comparable to results reported for SMPL-based models. By releasing the InfantNet dataset and benchmark, we provide a vital resource for advancing infant pose analysis and related healthcare applications.

0.33

Cross-Device Transfer of a Hospital-Trained Fetal Head Circumference Model to a Low-Cost Handheld Ultrasound Probe

eess.IV ·2026-10-28 ·Patrick Gao, Lara Hart, Ken Sullivan
benchmark similarity 0.61
Abstract · 24 pages, 5 figures, 4 tables

Automated fetal head circumference (HC) measurement reaches near-expert accuracy on the HC18 benchmark, but published models are trained and evaluated on hospital-grade equipment. We quantify what happens when such a model is carried to a low-cost handheld probe. A lightweight segmentation network (CSM, 0.13M parameters) was trained on HC18 across five independent runs and applied without modification to images from a $1,350 handheld probe (SonoQue C3), acquired at the same visit as the reference hospital scan in 18 patients. In-domain accuracy was 2.34 +/- 0.43 mm; on handheld images the same model gave 16.12 mm against the hospital record, a 6.9-fold degradation. Input preprocessing, a choice rarely reported, accounted for about a third of that gap: direct resizing gave 49.45 mm against 16.12 mm for an aspect-preserving pipeline. A leave-one-out data-efficiency curve showed that fine-tuning on two images significantly worsened accuracy, and that from four images upward error fell by 0.75 mm per doubling of the local dataset (p = 0.0045), although no training-set size up to 27 images significantly improved on the unmodified model. Much of the residual gap belongs to the reference rather than the model: scored against a manual tracing of the same image the model was already within 10.48 mm, and its disagreement with sonographer calipers on the same frame was a near-constant offset, negative in 10 of 10 cases. A single calibration constant estimated leave-one-out reduced that disagreement from 8.12 mm to 3.49 mm, reaching the intraobserver reproducibility reported for experienced sonographers, but did not improve agreement with the hospital record. Cross-device evaluations should therefore report the input preprocessing used and characterise the precision of their reference standard.

0.21

Impact of Patient Orientation in Single- and Multi-View Camera Environments for AI-based Rehabilitation Monitoring

cs.CV ·2026-09-28 ·Miriama Jánošová, Andreas Lang, Petra Budikova, Jan Sedmidubsky
dataset similarity 0.60
Abstract

Automated quality assessment of rehabilitation exercises relies heavily on accurate human pose estimation from video data. Although numerous RGB-based pose estimation methods have been proposed, the impact of camera placement on detecting clinically relevant movement errors remains insufficiently explored. To address this gap, we introduce REHAB26-ViewAngles, a dataset comprising correct and incorrect rehabilitation exercise executions captured from a wide range of camera angles. Furthermore, we propose a novel separability metric to quantify an algorithm's ability to distinguish between valid and faulty exercise repetitions. Using these tools, we analyze how various RGB-based pose-estimation strategies are suitable for exercise quality assessment under varying camera placements. In particular, we analyze single-camera 2D and 3D pose estimation and four multi-camera strategies: a combination of two orthogonal 2D views, 3D triangulation, weighted 3D fusion, and an AI-based pose-estimation transformer model specifically trained from two synchronized cameras. Our findings reveal that an optimally placed 2D camera can improve the separability by 16.9% over the commonly used 0° frontal view and frequently outperforms single-camera 3D estimation, while combining two views can further improve accuracy by up to 13.1%. These results offer practical guidance for deploying rehabilitation monitoring in both home and clinical settings.

0.09

MedBOE: Optimization-Based Estimation of Complete Patient Body Models from Whole-Body Medical Imaging

cs.CV ·2026-10-20 ·Hoijoon Jung, Yuhao Wei, Mingxiao Tu, Younhyun Jung, Michael Fulham +1 more
similarity 0.59
Abstract · Hoijoon Jung and Yuhao Wei contributed equally to this work

True whole-body medical imaging captures a patient from head to toe and provides comprehensive anatomical and/or functional information. This coverage enables reconstruction of the external body surface, yielding patient body models. However, scanner geometry (e.g., bore diameter), patient characteristics, and positioning can leave body regions missing (e.g., lateral arms/torso, hands, forearms, elbows), producing incomplete patient body models. Such incompleteness limits downstream medical analyses, including derivation of body-habitus metrics (BHMs), such as body volume and surface area, for injected radiotracer activity regimens, cardiometabolic risk assessment, and computational anatomical modeling for medical imaging simulation and radiation dosimetry. We present the Medical Body model Optimization-based Estimator (MedBOE), an automated, training-free framework for estimating complete patient body models from whole-body images with missing body regions. Our innovation is to leverage the Skinned Multi-Person Linear (SMPL) template, a parametric body mesh representing a broad range of body shapes and poses, in medical imaging. MedBOE aligns the SMPL template to the incomplete patient body models via attribute-guided optimization and estimates missing body regions through geometrically and volumetrically constrained deformation. We evaluated MedBOE using two public datasets: AutoPET (91 whole-body PET-CT images) and Human Implicit Tissues (HIT; 40 whole-body segmentations from MRI images). MedBOE achieved the best overall volumetric and geometric performance among evaluated methods. BHMs derived from MedBOE were within 2% error, suggesting low percentage errors for downstream analyses. MedBOE offers an automated, training-free method for estimating complete patient body models from whole-body images with missing body regions.

0.23

Prosthesis-Aware 3D Human Pose Estimation: A Dataset and Benchmark for RSP Users

cs.CV ·2026-09-16 ·Yilin Wen, Kechuan Dong, Fumiya Suginaka, Ken Endo, Yusuke Sugano
top venuebenchmarkdatasetcode/data similarity 0.58
Abstract · ECCV 2026. Project page: https://ut-vision.github.io/RSP3D/

Recovering 3D human body motion from video is important for applications such as rehabilitation assessment and sports performance evaluation. For prosthesis users, this requires capturing both natural body joints and the geometry of the prosthetic device, a challenge that existing methods are not designed to address. Model-based estimators rely on body models trained on non-amputee individuals and cannot represent prosthesis geometry, while model-free methods lack body kinematic priors and are unreliable under occlusion. This challenge is particularly prominent for users of running-specific prostheses (RSPs), where the RSP has a complex curved geometry and moves dynamically during exercise. To fill this gap, we collect RSP3D, the first 3D dataset of RSP users, covering essential daily-life and exercise actions from participants with varied amputation conditions, using a multi-camera marker-based motion capture setup. We formally define the task of prosthesis-aware 3D pose estimation, evaluate representative methods in a zero-shot setting, and confirm their individual limitations. We further propose a hybrid baseline combining model-based body joint estimation with model-free RSP shape recovery, establishing a starting point for future research.

0.50

Cross-Model Distillation of a Human-Pose Foundation Model from Unannotated Infant Video for Markerless 3D Pose Estimation

cs.CV ·2026-09-01 ·R. James Cotton, Divya Joshi, Colleen Peyton
published similarity 0.58
Abstract · Accepted to the ECCV 2026 Workshop MoCha

Spontaneous movement is one of the earliest windows onto an infant's neuromotor health, and structured clinical instruments that score it are validated early predictors of cerebral-palsy risk. However, they require specially trained raters, are time-consuming, and carry inter-rater variability. This motivates automated, video-based markerless assessment, especially as marker-based motion capture is impractical in infants. Yet the foundation models that make markerless capture possible are trained almost entirely on adults: our recent multi-view infant study found that no single model is jointly best, with strong 2D keypoint accuracy and direct 3D body recovery split across different models. While that study identifies this trade-off, it does not resolve it. Here, we perform cross-model distillation from the Sapiens 2 pose model into the SAM 3D Body model, using unannotated infant video alone. A frozen teacher supplies dense pseudo-labels, and a differentiable renderer aligns the predicted mesh to them in the training loop. On eleven held-out infants (18 sessions, 173 recordings) under our prior study's multi-view protocol, fine-tuning improves same-view 2D keypoint agreement with the Sapiens reference (median body percentage of correct keypoints @ 10px 0.22 -> 0.42, face 0.22 -> 0.42) and Procrustes-aligned mean per joint 3D position error (25.5 -> 22.2 mm). This demonstrates how cross-model distillation improves SAM 3D Body model performance on infants.

0.38

MetricPose: Flexible 3D Human Pose Estimation with Depth and Geometric Cues

cs.CV ·2026-11-06 ·Shifan Zhu, Sabad Modi, Hang Yang, Arushi Agrawal, Steven Gao +3 more
published similarity 0.58
Abstract · 9 pages, 3 figures, ICRA submission

In this paper, we present a 3D human pose estimator that predicts metrically accurate human joint positions in the camera coordinate frame. This task requires recovering the configuration of the body joints, scale, and metric camera-local placement. In monocular images, body size and camera distance are coupled through perspective projection and therefore cannot be determined uniquely from image alone. This ambiguity can be reduced by combining three complementary sources of information: learned RGB priors, direct depth measurements, and geometric constraints (e.g., ground contact) from the environment. We extend a pretrained full-body estimator with optional metric depth and geometry-processing modules that improve camera-distance estimation and depth-guided body refinement while preserving RGB-only operation. The resulting unified model supports RGB, RGB-Ground, and RGB-D using shared learned parameters. Unlike pelvis-relative error, camera-local error also measures placement relative to the camera. Compared with the existing foundation model SAM 3D Body, our methods with RGB, RGB-Ground, and RGB-D modes reduce camera-local joint-position error by 12.16%, 31.00% and 54.61% respectively.

0.31

HandSplatter: Automated Digital Goniometry from Neural Rendering

cs.CV ·2026-08-10 ·Emmett Chen, Neal Chen, Xiang Li, Quanzheng Li, Siyeop Yoon
published similarity 0.58
Abstract · Accepted for publication in the Proceedings of the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Soci…

Hand and finger disorders are leading contributors to musculoskeletal disability, creating a clinical need for precise methods to quantify joint motion. Range of motion (ROM) serves as the metric for diagnosis, rehabilitation monitoring, and evaluating surgical outcomes. Currently, the goniometer is the standard tool for assessing finger flexion and extension. However, manual goniometry is labor-intensive and suffers from inconsistent inter-rater reliability due to variations in examiner technique. While digital alternatives exist, current software-based approaches often lack the necessary accuracy for clinical usage. To address these limitations, we present a novel pipeline for 3-D hand joint location and pose estimation using neural rendering. Unlike previous methods, our approach combines 2-D feature extraction with view synthesis to significantly improve accuracy and clinical viability. Furthermore, we introduce a discrete density hill climbing algorithm that facilitates the meaningful correction of projected landmarks in 3-D space. This system overcomes the inefficiencies of manual measurement and the inaccuracies of existing software, providing a robust tool for objective functional assessment.

0.19