TRIAGE: Risk-Controlled Pseudo-Label Admission for Annotation-Efficient Semi-Supervised Retinal OCT Classification

Md Ashraful Hossen Akash, Shyla Afroge, Abdullah Al Mamun, Md. Kishor Morol, Tze Hui Liew

cs.CV ·submitted 2026-08-14 14:06 UTC · v1
code/data

Abstract

The advanced retinal disease diagnosing imaging modality, optical coherence tomography (OCT), encounters a lack of automation because of the high expenses for annotations performed by specialists. The use of SSL solves the problem of insufficient annotations using unlabeled B-scans; however, most of the current techniques for generating pseudo-labels are based on prediction confidence without considering the asymmetry between different types of errors. This paper proposes TRIAGE, a risk-controlled semi-supervised framework for OCT scans classification, which uses the concept of a patient-level conformal risk controller with an asymmetric cost matrix. TRIAGE unites three crucial modules: a hierarchical classifier that is capable of working with partially abnormal supervision of the disease subtypes, a patient-grouped conformal risk controller with primal-dual coverage control, and a context-aware Transformer teacher for cross-slice verification. On the dataset from Noor Eye Hospital (16,822 B-scans, 161 patients, and 554 volumes) with a test set of unseen patients, TRIAGE demonstrates 89.66% scan-level accuracy, 0.8805 macro-F1, 0.9641 macro-AUC, and an 8.34% under-grading rate when using only 20% of the labeled data. With only 5% of the labeled data, TRIAGE keeps 76.88% accuracy and a 0.1656 under-grading rate. Compared with the other six state-of-the-art semi-supervised methods, TRIAGE significantly outperforms them with ablation study demonstrating the contribution of each module in the overall framework performance (by 42.7% in terms of under-grading rate comparing to fixed threshold methods). TRIAGE demonstrates 98.00% accuracy for 3-class classification with 1% labeled data and 95.94% accuracy for 8-class classification with 10% labeled data on the OCT-C8 dataset.

Comment
38 pages, 12 figures, 13 tables. Code available at https://github.com/mdahakash/TRIAGE/

Closest papers

Nearest neighbours by meaning across the whole index.

Domain-Specific Self-Supervised Representation Learning for Retinal Fundus Classification

cs.CV cs.LG ·2026-08-27 ·Bekzat Nurlanbekova, Fung Fung Ting
similarity 0.66
Abstract

Annotated medical images remain scarce and costly to obtain, which motivates self-supervised learning (SSL). We present a controlled empirical study of two SSL frameworks, SimSiam and SimCLR, for retinal fundus classification, asking whether retina-specific augmentations (Graham's local-mean subtraction and CLAHE) improve representations beyond standard augmentation and grayscale conversion. ResNet-18 backbones are pretrained on 48K unlabeled fundus images and evaluated by linear probing and fine-tuning on EDID (multi-disease) and RetinaMNIST (DR grading). On EDID, grayscale conversion accounts for most of SimSiam's linear-probe gain, and Graham or CLAHE add little on top of it. After fine-tuning, SimSiam with Graham+Gray exceeds an ImageNet-supervised baseline on RetinaMNIST (+3.0 accuracy points) but only matches it on EDID. Retina-specific augmentation therefore helps inconsistently and should be validated per SSL method and task.

0.14

Beyond Accuracy: Benchmarking Uncertainty Quantification in Retinal Disease Screening

eess.IV ·2026-11-17 ·Mahvash Jebeli, Mohammad Eslami, Nazlee Zebardast, Lucia Sobrin, Tobias Elze
benchmarkdataset similarity 0.64
Abstract

Reliable uncertainty quantification (UQ) is essential for evaluating retinal AI systems beyond classification accuracy, yet it remains unclear whether existing UQ strategies generalize across diseases, model architectures, and reliability criteria. We introduce a large-scale, multi-disease benchmark comprising over $242,000$ fundus photographs from $32$ datasets covering diabetic retinopathy, age-related macular degeneration, and glaucoma. We evaluate six representative UQ strategies across three Vision Transformer configurations, assessing discrimination, probabilistic calibration, selective prediction, and conformal prediction-set coverage. Our findings reveal no universally superior model or UQ strategy: methods that improve reliability in one disease or architecture may underperform in another, while improvements in discrimination, calibration, and selective prediction do not necessarily align. Notably, computationally intensive methods do not consistently outperform simple confidence scores, and domain-specific foundation models and calibration-oriented loss functions do not guarantee greater reliability. In contrast, conformal prediction provides a complementary framework for achieving near-nominal marginal prediction-set coverage across diverse settings, subject to its statistical assumptions. These findings challenge universal UQ recommendations and highlight the need for disease-specific, model-specific, and multidimensional reliability evaluation before clinical deployment. We release standardized dataset splits, trained checkpoints, evaluation code, and an interactive research demonstration to support reproducible benchmarking.

0.06

Certify, Report, or Refuse: Harm-Constrained Conformal Prediction for Clinical Actions

cs.LG cs.AI ·2026-11-09 ·Zhiyuan Li, Lequan Yu
similarity 0.63
Abstract · Findings of the 6th Machine Learning for Health Symposium (ML4H 2026)

Routing a melanoma case to routine follow-up is a serious action error that diagnostic coverage alone does not rule out. We present Harm-Constrained Risk-Optimal Conformal Prediction (HC-ROCP), a training-free framework that uses frozen classifier probabilities and adds a harm penalty when choosing prediction sets and actions. We test the resulting policies on disjoint calibration splits with multiplicity adjustment. HC-ROCP certifies supported claims, reports descriptive fallback policies, and refuses unsupported subgroup claims. We evaluate these outputs retrospectively on COVID-19 radiographs, ISIC 2019 dermoscopy, and EyePACS-to-APTOS retinopathy transfer. Across ten calibration seeds, HC-ROCP reduces COVID-19 severe-action errors from the exact risk-optimal baseline's 4.68\% to 0.54\%. At a 5\% budget, global claims are certified for COVID-19 and ISIC, but the rare squamous-cell-carcinoma claim is refused. At 1\%, all settings receive descriptive reports. For each budget, we also report the minimum severe-case count needed to pass the global harm gate with zero errors, providing a starting point for further data collection.

0.15

Region-aware error triage for medical image segmentation with groupwise conformal risk control

cs.CV ·2026-11-06 ·Nishi Kanta Paul, Md Shihabul Islam Shovo, Hoileong Lee
similarity 0.62
Abstract · 22 pages, 7 figures, 12 tables. Submitted to Biomedical Signal Processing and Control (BSPC)

Segmentation masks are increasingly reviewed rather than redrawn, which requires knowing where a mask is likely wrong. Learned error maps rank pixels by risk, but the number of pixels to warn is chosen ad hoc, and calibrating one warning threshold over all error pixels may leave errors far from the predicted contour under-flagged. We propose RACE-Triage, a post-hoc error triage framework that leaves the segmentation mask unchanged. A risk network is trained on out-of-fold predictions from backbone-independent inputs. The predicted contour partitions each image into a boundary band and a non-boundary region, and conformal risk control is applied separately in each region to bound the expected fraction of missed errors among cases with errors there. On ISIC 2018 dermoscopy and BUSI breast ultrasound (where patient identifiers are unavailable, so independence across images is assumed), pooled control met its overall target but missed on average 31.8% and 36.4% of non-boundary errors. Regional control reduced these fractions to 19.3% and 20.9% and raised the recall of size-filtered false-negative components from 0.722 to 0.818 and from 0.611 to 0.763. The mean warned area grew by 1.6 and 4.9 percentage points, and its 95th percentile reached 23.5% and 38.5%. The effect held across three seeds and a second backbone, and area-matched heuristics did not reproduce it. On the external PH$^2$ set, frozen thresholds exceeded both targets, whereas recalibration with 100 local images brought the mean over repeated splits below them. Regional calibration improves non-boundary error coverage at a measured increase in warned area.

0.30

Adaptive Conformal Redistribution for Inter-class Transitional Uncertainty in Medical Image Classification

cs.CV cs.AIcs.LGstat.CO+1 ·2026-09-10 ·Saibal Ghosh, Samarup Bhattacharya, Sanjoy Kumar Saha, Umapada Pal, Tapabrata Chakraborti
benchmarkcode/data similarity 0.62
Abstract

Medical image classification is frequently complicated by transitional categories whose feature distributions overlap those of adjacent classes, producing ambiguous decision boundaries. Conformal prediction returns uncertainty-aware prediction sets, but these are not directly actionable in clinical screening, where a single decision is required. This work proposes adaptive conformal redistribution (AdaConRed), a label-free post-conformal decision rule that converts ambiguous prediction sets into refined class assignments. A five-stage pipeline is developed. Vision-language generative augmentation addresses minority-class scarcity; a frozen DermFoundation encoder provides embeddings; a lightweight multi-layer perceptron performs classification; an entropy-modulated, margin-aware nonconformity score constructs adaptive prediction sets; samples predicted as transitional with multi-label sets are reassigned to the most probable alternative class within the set, using only model outputs at inference. Evaluation uses the OSCC oral lesion and ISIC skin lesion benchmarks at a miscoverage level of 0.2. On the 3-class OSCC benchmark, overall accuracy improves from 73.54% to 77.38%, with oral cancer accuracy rising from 64.29% to 82.14% and benign accuracy from 56.57% to 70.20%. Reassignment of transitional samples reduces OPMD accuracy from 84.78% to 80.16%, consistent with the asymmetric cost of missed malignancy. On ISIC, overall accuracy improves from 85.83% to 87.19%, melanoma accuracy rising from 66.04% to 68.34%. AdaConRed outperforms LAC, APS and RAPS under an identical backbone and redistribution rule. Conformal prediction can be extended beyond uncertainty quantification toward actionable decision support where transitional disease categories are present, with gains concentrated in the clinically critical malignant categories. Code repository: https://github.com/saibal436ghosh/AdaConRed.

0.38

RetinaGuard: Risk-Controlled Agentic Triage for Multi-Disease Retinal Screening

cs.AI ·2026-11-07 ·Sohaib Sulman, Muhammad Atif Saeed, Akhtar Jamil, Alaa Ali Hameed, Roland Aydin
similarity 0.61
Abstract

Retinal screening programmes need to know which automated decisions can be accepted without review. This paper presents RetinaGuard, an agentic triage framework in which quality, diagnostic, uncertainty, verification and explanation agents gather evidence for each fundus photograph, a learned failure predictor estimates the probability that the decision is unsafe, auxiliary tools are invoked only when their expected value of information exceeds their cost, and the acceptance threshold is certified by conformal risk control. On the RFMiD test split, RetinaGuard was compared with confidence and calibrated-uncertainty referral at matched referral budgets and equal certified safety, using two RETFound primary models of different strength. With the weaker model (macro-AUROC 0.896), verifier disagreement added significant information, RetinaGuard captured 119 of 280 unsafe decisions at a 20% budget against 88 for lowest-confidence referral, and at a nominal 5% unsafe level it accepted 37.0% of cases against 10.3%. With the stronger model (0.925) the verifier added nothing beyond uncertainty and the advantage shrank to a few percentage points. In both settings its coverage at the nominal 5% level stayed near 37.7%, gating cut computation by about 30%, and a quality agent reduced unsafe acceptances under most image corruptions. The benefit of agentic evidence gathering thus depends on how much the primary model's own uncertainty already reveals about its errors.

0.25

OCT-FedSIR: Toward Trustworthy Federated Ophthalmic Learning under Annotation Noise

cs.LG cs.AIcs.DC ·2026-09-13 ·Sina Gholami, Abdulmoneam Ali, Tania Haghighi, Rashadul H. Badhon, Behafarin Emam +6 more
similarity 0.61
Abstract · 38 pages, 7 figures, 4 tables, 6 tables in supplementary material

Federated learning enables collaborative model development without centralizing patient data, but annotation reliability at participating institutions cannot always be assumed. In ophthalmic imaging, differences in disease prevalence and class composition can resemble changes caused by corrupted supervision. We introduce OCT-FedSIR, a reliability-aware spectral framework for federated OCT classification under client-dependent annotation noise and heterogeneous data distributions. OCT-FedSIR combines class-balanced spectral estimation, Stage-I logit adjustment, complementary spectral descriptors, selective spectral relabeling, and noise-aware federated optimization. We evaluated the framework on the Kermany, University of Illinois Chicago, and Wake Forest datasets under symmetric and structured asymmetric noise and three levels of non-IID heterogeneity. Across 117 experimental conditions, OCT-FedSIR achieved a mean accuracy of 86.73%, compared with 79.94% for RoFL and 78.75% for FedCorr. It correctly separated clients with original and corrupted annotations across all evaluated conditions, while the original FedSIR identification procedure was less robust, particularly under asymmetric noise. Spectral relabeling recovered 77.2% of corrupted annotations with 91.3% correction precision and a 3.5% false-correction rate. Retaining corrected clients outperformed spectral pruning by 9.30 percentage points on average. These findings show that annotation noise can often be identified and corrected without discarding informative client data.

0.16

RadFusion: Towards Threshold-Controllable Radiology Report Generation

cs.AI cs.CLcs.CV ·2026-08-11 ·Ying Jin, Noel C. F. Codella, John Corring, Mu Wei, Dinei Florencio +1 more
similarity 0.60
Abstract

Automated radiology report generation is advancing rapidly in response to the shortage of radiologists, yet unlike a perception model, existing generation models offer no control over the sensitivity-specificity trade-off of their diagnostic content. Such control is essential because clinical scenarios diverge: emergency triage prioritizes sensitivity to reduce missed findings, whereas confirmatory interpretation emphasizes specificity to limit unnecessary interventions. A single fixed report can neither adapt to these scenarios nor support the ROC-based validation widely expected for regulatory clearance. We introduce RadFusion, a framework that equips report generation with threshold controllability. Our method fuses a multi-label classifier, which provides per-disease confidence scores, with a VQA-based report generator, which describes medical findings in detail; an LLM then rewrites the report so that its stated diagnoses follow the classifier's decisions at the selected threshold while staying grounded in the generator's descriptions. On MIMIC-CXR, the performance of RadFusion conforms to the classifier's ROC curve: sweeping the threshold and mapping the reports back to class labels reproduces the classifier's validated ROC performance. This conformance makes generated reports quantitatively evaluable through ROC analysis, strengthening the case for regulatory clearance, and enables operating-point selection that matches report behavior to clinical context. Moreover, combining the two model types improves diagnostic accuracy over uncontrolled generation: sensitivity increases by 6.9% at matched specificity, and specificity by 20.7% at matched sensitivity. These results show that RadFusion makes report generation clinically adaptable, quantitatively verifiable, and diagnostically more reliable.

0.04