CS Paper Radar

Synthesizing Post-Acetazolamide Cerebral Blood Flow Maps from Baseline MRI in Moyamoya Using 3D Generative AI

Julia Huang, Camila Gonzalez, Rydham Goyal, Aja Zou, Sasha Alexander, Michael Moseley, Moss Y. Zhao, Gary K. Steinberg

eess.IV cs.AIcs.CV ·submitted 2026-08-14 08:14 UTC · v1
top venue

Abstract

For patients with Moyamoya disease, impaired cerebrovascular reserve (CVR) is an important hemodynamic criterion for recommending extracranial-to-intracranial bypass surgery. Standard CVR assessment in this cohort uses paired arterial spin labeling (ASL) perfusion MRI acquired before and after acetazolamide (ACZ). When ACZ is contraindicated or avoided, the post-ACZ cerebral blood flow (CBF) map needed for hemodynamic assessment is unavailable. We propose CAE3D, a deterministic 3D conditional autoencoder that synthesizes post-ACZ CBF maps directly from pre-ACZ ASL input. We evaluated CAE3D against ten comparators, including deterministic and diffusion-style 3D baselines, a 2D contextual baseline, and frozen-encoder foundation-model adapters. CAE3D achieved the lowest held-out MAE (0.066), with SSIM 0.80 and PSNR 24.0 dB, and near-zero full-brain mean bias. Its MAE advantage was statistically significant over seven of eight trained-from-scratch baselines, excluding the 2D CAE_2D comparator; its SSIM and PSNR advantages were significant over all eight. Regional delta-CBF predictions compressed the dynamic range in high-response territories. These results establish the retrospective feasibility of post-ACZ CBF synthesis in patients who completed the standard two-scan protocol. Extension to ACZ-contraindicated patients, who were not represented in this cohort, requires external and prospective validation.

Comment
25 pages. Accepted at Machine Learning for Healthcare (MLHC 2026). To appear in Proceedings of Machine Learning Research (PMLR), volume 340

Closest papers

Nearest neighbours by meaning across the whole index.

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.64
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.14

DuoPIC: Uncertainty-Aware Voxel-Level Digital Twins of Cerebral Perfusion with Transport PDEs in Acute Stroke

cs.CV ·2026-10-20 ·Anh Duong Tran, Quang-Anh N. D., Toan Sy Pham, Trang H. Hoang, Minh N. Do +2 more
code/data similarity 0.63
Abstract

Digital twins of cerebral perfusion relate tracer dynamics to cerebral blood flow (CBF), blood volume (CBV) and mean transit time (MTT), but must be data-driven, physically consistent and uncertainty-aware. We introduce DuoPIC, a digital twin that needs no reference maps, in which a Windkessel flow model drives a tracer transport partial differential equation (PDE). A population-level neural closure divides each region into fast and slow pathways with tracer mass and MTT conserved by construction, and a tempered posterior quantifies the uncertainty of every estimate. Its voxel maps set the state of the art for lesion detection on ISLES'17 MR (AUC 0.745) and ISLES'24 CT (0.743). On held-out patients, the neural PDE reduced the compartment's reconstruction error by 19% and lifted 95% MTT interval coverage from 88% to 94%. Code: https://github.com/detinatran/duopic

0.36

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

eess.IV cs.CV ·2026-10-23 ·Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian +10 more
similarity 0.62
Abstract · 36 pages, 7 main figures, 2 supplementary figures. Under review at Medical Image Analysis

4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

0.21

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
similarity 0.62
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

0.18

Mr3D-VL: A generalist vision language foundation model for Multiparametric 3D Magnetic Resonance Imaging

cs.CV cs.AI ·2026-08-13 ·Zhi Qiao, Xintong Wu, Yichu He, Feng Shi
similarity 0.62
Abstract

Multi-parametric magnetic resonance imaging (mpMRI) is a cornerstone for brain tumor diagnosis and treatment, yet current AI models face critical limitations: their lack of natural language interaction and interpretability impedes spatial information integration and cross-modal reasoning required clinically. Key challenges arise from significant physical meaning differences across modalities, spatial misalignment due to scan intervals, and the need for complex multi-feature interpretation in tasks like glioma grading. While visual-language models (VLMs) show promise in cross-modal understanding, existing methods focus mainly on 2D image modeling, neglecting direct perception of 3D volumetric space. Although 3D VLMs have been proposed for report generation and feature alignment in 3D CT imaging, mpMRI applications demand collaborative inference across multiple imaging modalities-a requirement unmet by current solutions. To address this, we introduce Mr3D-VL, a dedicated visual-language foundation model for multi-parametric 3D MRI. With 4 billion parameters, it employs an unsupervised pre-trained shared 3D encoder and 4D rotational positional embedding for dual modality-spatial integration. Its cross-modal projection layer uses a multi-resolution feature implantation strategy to enhance feature perception across resolutions. Experimental results show significant improvements over existing 4B/7B/30B domain-specific and general-purpose models in text generation tasks, achieving a BERTScore of 0.856 for report generation, with question-answering accuracy at 0.713 and multiple-choice accuracy at 0.912.

0.04

MOSAIC-Flow: Orthogonal-Axis and Status-Conditioned Fusion for Missing-Sequence Completion in Brain Tumor MRI

cs.CV ·2026-10-29 ·Pengli Zhu, Zhihao Peng, Yixuan Yuan
code/data similarity 0.62
Abstract · 5 pages, 4 figures

Missing-sequence completion is important for comprehensive brain tumor characterization, but cross-modal fusion can obscure sequence-specific contrast and lose fine-grained three-dimensional tumor detail. To address this challenge, we introduce Modality-aware Orthogonal-axis Status-conditioned Attentive Integration for Completion (MOSAIC-Flow), a unified framework for missing-sequence completion that learns a target-conditioned velocity field while keeping the seven acquired volumes fixed throughout the transport. Specifically, modality-aware stems independently encode each sequence, and orthogonal-axis refinement captures axial, coronal, and sagittal dependencies while retaining the three-dimensional representation. Status-conditioned prototype fusion uses compact modality and availability tokens to route and modulate pooled queries from the fused visual representation, enabling target-adaptive conditioning without dense voxel-to-voxel attention. A conditional flow matching objective transports target-channel noise toward the single missing sequence, while four Heun trajectories are averaged to produce the completion. Evaluation across structural, diffusion, and contrast-enhanced MRI in UCSF-PDGM demonstrates consistent whole-brain and tumor-region fidelity across all eight single-target completion tasks, with the strongest performance on structural sequences. Code is available at https://github.com/CUHK-AIM-Group/MOSAIC-FLOW.

0.21

AsymFeX: A Symmetry-Driven Framework for Ischemic Stroke Segmentation Across Imaging Modalities and Stroke Stages

eess.IV cs.CV ·2026-08-20 ·Maunil Shah, Vaanathi Sundaresan
code/data similarity 0.61
Abstract

Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning. Non-contrast CT (NCCT), the first-line imaging modality for diagnosing ischemic infarcts, exhibits subtle infarct contrast, making manual delineation slow and labor-intensive. Motivated by this, and by the clinical practice of comparing brain hemispheres to localize infarcts, we propose a two-stage, nnU-Net-compatible 3D segmentation method. The first stage corrects head tilt to align each scan to its true anatomical mid-sagittal plane; the second applies a novel Asymmetric Feature Extraction (AsymFeX) module, comparing each voxel to its true contralateral counterpart within a local 3 x 3 x 3 neighborhood via cross-hemispheric attention, feature disparity estimation, and dual-scale gating to capture both large and small infarcts. On AISD, our method achieves 0.6796 Dice, 23.53 mm HD95, and 7.69 mL AVD, significantly outperforming existing state-of-the-art methods, with clinically relevant volumetric analysis at the 70 mL thrombolysis-eligibility threshold. Proof-of-concept evaluation on ATLAS v2.1 and ISLES'24 demonstrates that the same symmetry-driven design generalizes across imaging modalities and stroke time points without architectural changes, further supported by an uncertainty analysis assessing reliability under clinical deployment. Code is publicly available at https://github.com/biomedia-lab/AIS-detection.

0.23

Zero-Shot Brain MRI Inpainting with 2.5D Unconditional Flow Priors

cs.CV ·2026-10-06 ·Arnela Hadzic, Franz Thaler, Simon Johannes Joham, Martin Urschler
code/data similarity 0.61
Abstract

Generative inpainting of brain MRI volumes is essential for synthesizing healthy tissue in pathological regions, improving the accuracy and reliability of automated downstream brain analysis applications such as image registration, brain extraction, and segmentation. However, standard 3D approaches are computationally prohibitive, while efficient 2D slice-wise methods suffer from severe inter-slice discontinuities. Furthermore, traditional models rely on conditional training, requiring task-specific learning of masked inputs. We propose a zero-shot brain MRI inpainting framework utilizing 2.5D unconditional flow priors to capture spatial context along the superior-inferior axis without the overhead of full 3D convolutions. During training, our flow matching model learns the joint distribution of adjacent axial slice triplets, modeling the manifold of healthy brain anatomy while explicitly excluding pathological regions from the loss function. At inference, the model processes the input triplets autoregressively along the depth axis. We employ the Restora-Flow solver to constrain the unconditional prior using the input mask, achieving accurate zero-shot inpainting. Evaluations show our 2.5D strategy resolves the structural discontinuities of 2D baselines, synthesizing plausible healthy tissue while maintaining volumetric consistency across the axial, sagittal, and coronal planes. As a final step, we generate and average an ensemble of multiple stochastic reconstructions to form the final prediction. Quantitative results benchmarked on the official BraTS 2026 Inpainting Challenge validation set demonstrate the effectiveness of our proposed approach, yielding an SSIM of 0.816 $\pm$ 0.112, MSE of 0.007 $\pm$ 0.005, and PSNR of 22.923 $\pm$ 4.343. Code is available at https://github.com/imigraz/brats2026-inpainting.

0.16