Adaptive Post-Processing Drives Instance-Level Detection in Stroke Lesion Segmentation

Qinghui Liu, Jon André Ottesen, Atle Bjørnerud, Kyrre Eeg Emblem

cs.CV cs.AI ·submitted 2026-08-17 10:30 UTC · v1
published

Abstract

Instance-level lesion detection has been an increasingly larger focal point in medical image segmentation besides the more standard voxel-level overlap. Still, most pipelines are trained and post-processed for voxel overlap alone. In particular, the mismatch is most pronounced for small lesions, where a near-miss prediction---substantial overlap that falls just short of the instance-matching threshold---scores the same as a complete miss. In our ISLES'26 submission, we found that closing this gap mattered far more in post-processing than in architecture design. Our Volume-Conditioned Adaptive Post-Processing (VCAP) scheme adjusts component-size thresholds to each case's predicted lesion burden, improving Lesion-F1 by 0.032 (unbiased cross-fold estimate)---approximately 6 times larger than any architectural change we tested. A resolution-aware attention architecture (Viola2Plus), designed for small-lesion segmentation, shows why the distinction matters: it left small-lesion Dice unchanged but raised small-lesion detection rate by 3.7\%, a real effect voxel-overlap metrics alone would have missed. Under 5-fold cross-validation on the 1,453-case training set, our post-processed two-architecture ensemble achieves Dice 0.651 and Lesion-F1 0.614, versus 0.644 and 0.573 for the unprocessed single-model baseline.

Comment
8 papges, 4 figs, 2 tables, MICCAI ISLES'26

Closest papers

Nearest neighbours by meaning across the whole index.

Native-Space 3D CarveMix for Multi-Site T1w Stroke Segmentation

eess.IV cs.CV ·2026-08-24 ·Dexter Wen Jie Teo, Kumaradevan Punithakumar
published similarity 0.67
Abstract · Accepted at the SWITCH+ Workshop (ISLES 2026 Challenge), MICCAI 2026. Springer LNCS

Segmenting ischemic stroke lesions on T1-weighted (T1w) MRI acquired across different scanners and protocols without intensity standardization is difficult because lesions are subtle and share intensity characteristics with cerebrospinal fluid. Standard deep learning architectures trained across multiple centers plateau around Dice 0.66, with acute lesions ($\le 7$ days post-stroke) performing substantially worse due to severe sample scarcity. We combine a MedNeXt-L ($k=5$) backbone with on-the-fly 3D CarveMix augmentation that pastes real lesion patches into healthy brain regions during training. By generating synthetic lesion placements dynamically within each fold with subject-level split isolation, the model sees more diverse lesion patterns without requiring pre-generated copies on disk. We evaluate on 1,453 native T1w scans from 55 clinical centers in the ISLES 2026 challenge. Our method achieves a mean 5-fold cross-validation Dice of 0.648 at 500 epochs, a +0.018 improvement over the MedNeXt-L backbone at a matched training budget (0.630)

0.31

BiCC: Bidirectional Connected-Component Loss for Instance-Aware Segmentation

cs.CV ·2026-09-24 ·Luc Bouteille, Frederic Jonske, Jens Kleesiek, Alexander Jaus
code/data similarity 0.66
Abstract · 2 figures, 3 tables. Code: https://github.com/TIO-IKIM/BiCC-Loss

Common segmentation losses aggregate errors voxel-wise, so lesions influence the objective in proportion to their volume, giving small but clinically critical lesions disproportionately little weight. Instance-aware losses aim to address this mismatch by assigning each lesion its own term. However, blob loss and CC-DiceCE derive their regions solely from annotations, so false-positive components receive no instance-level term. This matters in computer-assisted review, where each false-positive component may require separate inspection, making precision and false-positive burden important alongside recall. We introduce the bidirectional connected-component loss (BiCC), which pairs annotation- and prediction-derived partitions to score predicted components on their own scale. By deriving instances from the predictions, this branch directly penalizes false-positive components regardless of their size. The balance parameter $α$ allows control over the lesion-wise precision-recall trade-off. Across five datasets with five-fold cross-validation using nnU-Net, BiCC outperforms CC-DiceCE in lesion-wise F1 on four datasets and blob loss on all five. It significantly improves over DiceCE on three datasets and matches it on two; CC-DiceCE instead loses up to 0.363 precision by favoring recall. Code is available at https://github.com/TIO-IKIM/BiCC-Loss.

0.48

Synthetic training for long-tail haemorrhagic lesion segmentation in data-scarce settings

cs.CV ·2026-10-01 ·Yuan Cao, Sumeet Dash, Antonia Zachariadis, Stefanie Schreiber, Katja Neumann +1 more
published similarity 0.65
Abstract · Accepted: MICCAI 2026 SASHIMI workshop

Cerebral microbleeds (CMBs) and cortical superficial siderosis (cSS) are imaging markers of cerebral small vessel disease, but their automated segmentation is limited by the scarcity of positive cases and voxel-level annotations. We propose a synthetic training framework for long-tail haemorrhagic lesion segmentation that requires no real lesion annotations for training and leverages radiological description of the lesions. Starting from anatomical brain parcellations, the framework applies spatial augmentation and voxel resampling, procedurally inserts cSS and CMB labels using clinical priors on lesion location and morphology, and synthesises images through randomised intensity assignment, blurring, and Rician noise simulation. Models were trained on dynamically generated image-label pairs and evaluated against manual delineations in 10 cSS cases and 13 CMB cases. The proposed configurations outperformed classical filter baselines. For cSS, the hypointensity constrained model achieved higher AUPRC and AUROC than the Frangi filter (AUPRC: 0.284 vs 0.083; AUROC: 0.907 vs 0.731). For CMBs, explicit synthesis of blood vessels as lesion mimics improved performance over the classical baseline (AUPRC: 0.538 vs 0.004; AUROC: 0.999 vs 0.968). These results support our proposal as a feasible strategy for data-scarce haemorrhagic lesion segmentation.

0.39

SADL: A Size-Adaptive Decision Layer for Chronic Stroke Lesion Segmentation in ISLES 2026

cs.CV ·2026-10-09 ·Marek Wodzinski, Gniewosz Drwiega, Wojciech Szymanski
similarity 0.63
Abstract · ISLES 2026 Challenge Contribution

Chronic ischemic stroke lesions are difficult to segment on T1-weighted MRI. Their appearance overlaps with healthy tissue, and their volumes span four orders of magnitude, so voxel-level and lesion level metrics often disagree. We build an eleven-member nnU-Net ensemble that covers five design axes: a baseline dice + top-K loss, heavy augmentation, per-lesion volume loss re-weighting, stochastic weight averaging, and a sampling-and-architecture block that pairs cohort-balanced sampling with a residual-encoder backbone. Weighted soft-map fusion of the members feeds a tuned decision layer, SADL, that estimates lesion volume, applies an adaptive per-lesion-size threshold, prunes components by voxel count and peak probability, and adds a never-empty rescue. All fusion weights and per-bucket parameters are fitted on out-of-fold (OOF) predictions, so tuning never touches the held-out test set. On a site-disjoint 91-case holdout, SADL reaches Dice 0.7322, lesion-F1 0.7461 and PR-AUC 0.8430 when scored online with the challenge's released evaluation code. A paired non-parametric bootstrap against a reference single ensemble member confirms the lesion-F1 gain at p=0.024, and the gain is largest in the small-lesion regime, where the rescue step recovers cases that a fixed threshold would silently discard.

0.13

MicroBT: Centroid-Guided Synergistic Learning for Multi-Modal Micro Brain Tumor Segmentation and Counting

cs.CV cs.AI ·2026-11-10 ·Zhenye Lou, Qing Xu, Stefanie Thust, Dorothee P. Auer, Zhen Chen +1 more
publishedcode/data similarity 0.63
Abstract · Accepted at the 37th British Machine Vision Conference (BMVC), 2026

Multi-modal brain tumor segmentation is essential for clinical diagnosis, radiotherapy planning, and longitudinal monitoring. While recent studies have achieved remarkable overall segmentation performance, they rely on overlap-based objectives that inherently favor large regions, causing sub-3 mm micro-lesions to be systematically suppressed during training. Moreover, existing pixel-level segmentation frameworks lack explicit instance-level modeling, leading to unreliable lesion counting that directly impacts clinical staging and therapeutic decisions. To address these challenges, we propose MicroBT, a unified multi-modal framework for micro brain tumor segmentation and counting. Our core insight is that a fundamental geometric property is inherently scale-invariant: regardless of size, each lesion possesses a well-defined centroid. Leveraging this, we first devise a centroid-anchored synergistic paradigm that utilizes predicted centroids as shared anchors to simultaneously condition dense segmentation and instance-level localization. To counteract the tumor size imbalance, we further devise a Volume-Calibrated Loss (VC-Loss) that adaptively amplifies the gradient contribution of micro-lesions, alongside a Size-Aware Curriculum Optimization (SACO) that stabilizes multi-task training by establishing global representations before progressively unlocking fine-grained localization. Extensive experiments demonstrate that MicroBT outperforms state-of-the-art methods, particularly on metastases, where micro-lesion ($\leq 3$ mm) localization precision improves by approximately 7% and counting estimation errors decrease by approximately 26%. The code is available at https://github.com/leonlou921/MicroBT.

0.49

Acute Stroke Classification Using Asymmetric Data Standardization and Orthogonal-Focal Loss Optimized CNN-ViT Cross-Attention Fusion: A Multicenter External Validation Study

eess.IV cs.AI ·2026-10-25 ·Tansel Uyar
code/data similarity 0.62
Abstract · All research data has been uploaded to Zenodo (DOI: 10.5281/zenodo.22132268). The data presented in this study are available on request from…

Background/Objectives: Rapid differentiation of ischemic and hemorrhagic stroke subtypes is vital for acute management. Although current deep learning models achieve high single-dataset accuracy, they suffer from "shortcut learning" and domain shift in external validation. This study proposes a hierarchical computer-aided diagnostic (CAD) system mimicking emergency triage. Methods: We introduce a 3-channel Radiology-Focused Preprocessing pipeline that feeds radiological Hounsfield Unit (HU) windows into Convolutional Neural Network (CNN) and Vision Transformer (ViT) backbones via asymmetric formats (.mat and .png). The architecture utilizes a novel joint cross-attention fusion network optimized by an Integrated Orthogonal-Focal Loss. Results: Our system achieved a 95.48% F1-score on the internal stroke dataset. However, multi-center external validation (AISD, BHSD, PhysioNet) using a Mask Anchor filter revealed a drop to the 58-62% range, exposing the "internal validation illusion" caused by hardware noise. Critically, models exhibited high precision (77%) but low sensitivity (57%) for ischemic stroke, proving prone to hemorrhage overdiagnosis. Multi-seed variance analysis demonstrated that the DenseNet201+ViT backbone yielded the lowest deviation (0.59) and highest stability, making it the most reliable architecture for real-world clinical integration. Conclusions: To overcome diagnostic challenges, future research must focus on multimodal architectures that combine 3D volumetric extraction with clinical data.

0.33

An Anatomy-Aware Staged Pipeline for Vessel-Specific Intracranial Aneurysm Segmentation in CT and MR Angiography

eess.IV cs.CV ·2026-10-15 ·Gniewosz Drwiega, Wojciech Szymanski, Marek Wodzinski
published similarity 0.62
Abstract · Submitted version (7 August 2026) of a paper accepted at SWITCH+ 2026, a MICCAI 2026 workshop (TopAneu 2026 challenge track). Table 1 entrie…

The TopAneu 2026 challenge requires intracranial aneurysms to be segmented at the voxel level and assigned to one of more than fifty vessel-specific classes, on CT and MR angiography alike. We address it with a six-stage anatomy-aware pipeline rather than a single segmentation network. A logistic-regression classifier routes each scan to a modality-specific branch; networks segment the vasculature, first as a binary mask and then over the full 36-class arterial taxonomy; a candidate localiser turns raw angiography and vessel priors into suspicious regions; a candidate-centred network segments the lesion in each crop; connected components become instances; and a per-instance classifier assigns each its anatomical location. Two principles organise the design. Whenever an upstream model output becomes a downstream training input it is generated out-of-fold, so no stage trains on unrealistically clean predictions of itself. And the anatomical decision is made once per lesion rather than once per voxel, which fits the data: of 406 connected aneurysm components in the full release, 405 carry exactly one location label. Task 1 is read off the Task 2 mask, making the two consistent by construction. We report stage-wise performance and a five-part ablation isolating what vessel priors and class-aware sampling contribute at each stage.

0.24

MedSegBenchmarker: A Raw-Count-First Framework for Controlled 2D Medical Image Segmentation Benchmarks

cs.CV cs.AI ·2026-08-30 ·Vanessa Borst, Lukas Horn, Daniel Grillmeyer, Thomas Prantl, Samuel Kounev
benchmark similarity 0.62
Abstract · 10 pages, 4 figures;

Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

0.46