CS Paper Radar

SADL: A Size-Adaptive Decision Layer for Chronic Stroke Lesion Segmentation in ISLES 2026

Marek Wodzinski, Gniewosz Drwiega, Wojciech Szymanski

cs.CV ·submitted 2026-10-09 11:28 UTC · v1

Abstract

Chronic ischemic stroke lesions are difficult to segment on T1-weighted MRI. Their appearance overlaps with healthy tissue, and their volumes span four orders of magnitude, so voxel-level and lesion level metrics often disagree. We build an eleven-member nnU-Net ensemble that covers five design axes: a baseline dice + top-K loss, heavy augmentation, per-lesion volume loss re-weighting, stochastic weight averaging, and a sampling-and-architecture block that pairs cohort-balanced sampling with a residual-encoder backbone. Weighted soft-map fusion of the members feeds a tuned decision layer, SADL, that estimates lesion volume, applies an adaptive per-lesion-size threshold, prunes components by voxel count and peak probability, and adds a never-empty rescue. All fusion weights and per-bucket parameters are fitted on out-of-fold (OOF) predictions, so tuning never touches the held-out test set. On a site-disjoint 91-case holdout, SADL reaches Dice 0.7322, lesion-F1 0.7461 and PR-AUC 0.8430 when scored online with the challenge's released evaluation code. A paired non-parametric bootstrap against a reference single ensemble member confirms the lesion-F1 gain at p=0.024, and the gain is largest in the small-lesion regime, where the rescue step recovers cases that a fixed threshold would silently discard.

Comment
ISLES 2026 Challenge Contribution

Closest papers

Nearest neighbours by meaning across the whole index.

Native-Space 3D CarveMix for Multi-Site T1w Stroke Segmentation

eess.IV cs.CV ·2026-08-24 ·Dexter Wen Jie Teo, Kumaradevan Punithakumar
published similarity 0.69
Abstract · Accepted at the SWITCH+ Workshop (ISLES 2026 Challenge), MICCAI 2026. Springer LNCS

Segmenting ischemic stroke lesions on T1-weighted (T1w) MRI acquired across different scanners and protocols without intensity standardization is difficult because lesions are subtle and share intensity characteristics with cerebrospinal fluid. Standard deep learning architectures trained across multiple centers plateau around Dice 0.66, with acute lesions ($\le 7$ days post-stroke) performing substantially worse due to severe sample scarcity. We combine a MedNeXt-L ($k=5$) backbone with on-the-fly 3D CarveMix augmentation that pastes real lesion patches into healthy brain regions during training. By generating synthetic lesion placements dynamically within each fold with subject-level split isolation, the model sees more diverse lesion patterns without requiring pre-generated copies on disk. We evaluate on 1,453 native T1w scans from 55 clinical centers in the ISLES 2026 challenge. Our method achieves a mean 5-fold cross-validation Dice of 0.648 at 500 epochs, a +0.018 improvement over the MedNeXt-L backbone at a matched training budget (0.630)

0.31

Interpretable Multimodal MRI-Clinical Fusion for Functional Outcome Prediction After Acute Ischemic Stroke

cs.LG cs.AIcs.CVeess.IV ·2026-11-05 ·Sina Raeisadigh, Henning Müller, Abderrahmane Hedjoudje
similarity 0.67
Abstract · 5 pages, 2 figures, 1 table

This study evaluates the added prognostic value of day-1 multimodal MRI for predicting three-month functional outcome after acute ischemic stroke (AIS). Sixty-six AIS patients with ADC, DWI, FLAIR, and clinical data were analyzed. Three-dimensional pretrained ResNet embeddings were extracted from each MRI modality, reduced using fold-isolated principal component analysis, and combined with structured clinical variables and ADC-derived lesion biomarkers. Linear support vector machines were evaluated using eight-fold stratified group cross-validation across MRI modality combinations. Clinical-only modeling achieved strong performance (AUC = $0.899 \pm 0.151$), while MRI-only models showed limited discrimination (AUC $\approx$ $0.67$-$0.73$). Among multimodal configurations, FLAIR-clinical fusion achieved the highest mean cross-validated performance (AUC = $0.948 \pm 0.061$), followed by ADC-clinical fusion (AUC = $0.941 \pm 0.094$). Full ADC-DWI-FLAIR fusion did not consistently outperform single-modality clinical fusion. Feature-importance analysis identified age, NIHSS subscores, ADC lesion burden, and learned FLAIR representations as key contributors, while qualitative FLAIR activation maps showed responses over lesion-like regions. These findings suggest that compact day-1 FLAIR and ADC representations provide complementary prognostic information beyond clinical variables and support interpretable, data-efficient outcome prediction in AIS.

0.16

Deep Learning Segmentation of Diffusion-Weighted MRI Acute Ischaemic Stroke: A Pragmatic Evaluation Across Three Datasets

cs.CV ·2026-08-26 ·Atle Bjørnerud, Till Schellhorn, Thor H. Skattør, Terje Nome, Jon André Ottesen +2 more
similarity 0.67
Abstract · 19 pages, 8 figure and 4 tables

Objective: Diffusion-weighted MRI (DWI-MRI) is the gold standard for visualizing and quantifying acute ischaemic stroke (AIS). Although deep learning methods can accurately segment AIS lesions, the optimal image inputs and model architecture remain uncertain. We evaluated whether accurate AIS lesion segmentation can be achieved using a pragmatic deep learning approach with minimal preprocessing and clinically feasible inference times. Materials and Methods: Self-configured nnU-Net models were trained on 1,744 DWI cases from local, national, and open-access datasets and tested on 436 cases. Four experimental conditions were evaluated using five-fold cross-validation: with or without brain extraction and using either DWI alone or DWI plus apparent diffusion coefficient (ADC) images as inputs. Two architectures were compared: the baseline nnU-Net (base) and a residual encoder nnU-Net (ResEnc). Performance was benchmarked against the DeepISLES ensemble model from the 2022 ISLES challenge. Results: In the test set (n=436), the base model achieved a median (IQR) Dice similarity coefficient (DSC) of 0.84 (0.19). For the base model, only two of six pairwise comparisons between input configurations showed significant differences. ResEnc produced small but significant improvements in DSC compared with the base model for DWI, DWI+brain extraction, and DWI+ADC inputs (all p<0.02), but not for DWI+ADC+brain extraction (p>0.50). The base model significantly outperformed DeepISLES, particularly in patients with smaller infarct volumes (signed-rank test, p<0.01). Conclusions: A baseline nnU-Net trained on DWI alone, without preprocessing, enabled fast and accurate AIS lesion segmentation. This streamlined approach may facilitate clinical research and support acute stroke imaging workflows

0.22

Pre- and Post-Treatment Brain Metastases Segmentation Using nnU-Net with Post-Processing for BraTS 2026

cs.CV ·2026-09-10 ·Haobin Liu, Xin Wang
publishedbenchmarkcode/data similarity 0.65
Abstract · Accepted to MICCAI 2026 Challenge BraTS-METS

Brain metastases exhibit high inter-lesion variability in size, enhancement pattern, and post-treatment appearance, making volumetric segmentation of both pre- and post-treatment cases the central challenge of the BraTS 2026 Task 1 (Brain Metastases). We build a pragmatic pipeline on a 5-fold nnU-Net ResEnc-L ensemble, in which each fold is trained independently for 1,000 epochs with the standard Dice + cross-entropy loss on 1,296 four-modality training cases. This ensemble is followed by a rule-based post-processing cascade tuned for the lesion-wise Dice similarity coefficient (LW-DSC), a detection-oriented metric that behaves very differently from the traditional global Dice. The final pipeline reaches an LW-DSC of 0.733 / 0.751 / 0.713 / 0.549 on the enhancing tumour (ET), tumour core (TC), whole tumour (WT), and resection cavity (RC) sub-regions on the official validation leaderboard. Rather than trusting these leaderboard gains, we audit every post-processing stage with a five-fold out-of-fold (OOF) analysis with no model-training leakage over all 1,296 training cases, scored with the official BraTS evaluation code (BraTS_evaluation): it confirms two stages as robust, per-fold-consistent improvements while the third improves only the leaderboard and does not reproduce out-of-fold. We further provide a mechanistic analysis of the LW-DSC metric that explains why recall-recovering post-processing carries low risk whereas component deletion does not, and we report thirteen negative results spanning loss engineering, alternative backbones, and inference-time settings, several of which run counter to widely held intuitions. Source code is released under Apache-2.0 at https://github.com/hornbeamliu/brats2026-met.

0.48

LightMedSeg-ISLES: Stroke Lesion Segmentation with 81x Fewer Parameters than nnU-Net

cs.CV cs.LG ·2026-09-09 ·Giorgi Nikvashvili, Hanxue Gu, Jie Bao, Kang Wang, Yang Yang
similarity 0.65
Abstract · 8 pages, 3 figures. Submitted to ISLES 2026 challenge. To be published in Springer Lecture Notes in Computer Science (LNCS) as part of the S…

Large networks and ensembles often lead medical image segmentation challenges, but their storage and inference demands complicate deployment. We present LightMedSeg-ISLES, a 1.26-million-parameter pipeline for T1-weighted stroke lesion segmentation in ISLES'26. On a 146-case held-out cohort, flip test-time augmentation produces 0.618 mean Dice and 0.599 lesion-wise F1. A 102.35-million-parameter nnU-Net ResEnc-L produces 0.634 Dice and 0.544 lesion-wise F1 after size filtering. LightMedSeg therefore retains 97.5\% of nnU-Net's Dice with 81.4$\times$ fewer parameters while improving lesion-wise F1 by 0.055. Its four-pass TTA operating point requires 4.7$\times$ fewer FLOPs per standardized patch than nnU-Net. It also slightly exceeds filtered UNETR++ and nnFormer. Longer training and stronger augmentation add 0.0358 Dice without increasing capacity, establishing a strong single-checkpoint alternative to much larger models.

0.38

Ischemic Stroke Segmentation and Net Water Uptake Quantification on Multicenter Non-Contrast CT Using Supervised Target-Domain Adaptation

cs.CV ·2026-09-17 ·Linus Britt, Maximilian Nielsen, Susan Klapproth, Andre Kemmling, Michael H. Lev +3 more
similarity 0.65
Abstract

Objectives: Quantitative assessment of infarct hypodensity on non-contrast computed tomography (NCCT), including net water uptake (NWU), requires manual or semi-manual lesion delineation, often guided by CT perfusion or diffusion-weighted MRI, limiting clinical applicability. Automated segmentation on NCCT could enable efficient biomarker extraction such as NWU but remains challenging across heterogeneous multicenter data. This study aimed to develop and externally test a domain-aware deep learning framework for ischemic stroke segmentation on NCCT and assess its suitability for NWU quantification. Materials & Methods: In this retrospective multicenter study of 801 patients from four datasets, an nnU-Net-based model was trained on NCCT scans from the University Medical Center Hamburg-Eppendorf and the Acute Ischemic Stroke Dataset. To adapt to new domains, the model was fine-tuned on target-domain subsets from Boston (n=11) and ISLES (n=75), with evaluation on held-out cases not used for fine-tuning. Automated segmentations and NWU values were compared with expert references. Results: For lesions $\geq$ 30 mL, median Dice was 0.68 (Boston) and 0.56 (ISLES). Including smaller lesions, which predominated in ISLES, median Dice was 0.54 (interquartile range [IQR] 0.30-0.70) for acute lesion segmentation (Boston dataset) and 0.20 (IQR 0.03-0.41) for NCCT lesion segmentations when compared to post-treatment infarct (primary target of the ISLES challenge). Automated NWU mean absolute error was 1.37 percentage points (SD 1.61, Boston). Conclusion: Target-domain adaptation supported NCCT-only infarct segmentation across heterogeneous external cohorts, although performance varied across domains. The approach enabled low-error NWU quantification from baseline NCCT without advanced imaging, supporting further prospective clinical evaluation.

0.04

Sharpening the Ensemble: An SSIM-Aligned Residual Refiner for Brain-MRI Inpainting Post-Processing

cs.CV cs.LG ·2026-09-03 ·Kubilay Kağan Kömürcü, İlkay Öksüz
publishedbenchmarkhot direction similarity 0.65
Abstract · Accepted at the MICCAI BraTS Local Synthesis of Brain Tissue Inpainting Challenge (Task 4), MICCAI 2026. 12 pages, 2 figures

Brain-MRI inpainting replaces a masked region of a scan with synthesized, anatomically plausible healthy tissue, so that analysis tools built for healthy brains can be applied to images they would otherwise reject. On the BraTS local-synthesis benchmark, which ranks submissions on the structural similarity index (SSIM), the peak signal-to-noise ratio, and the mean squared error (MSE) jointly, the strongest recent models are accurate, but several report blurry synthesized regions and attribute this to the mean-seeking behavior of the $\ell_1$ and MSE terms in their training losses. We address this in post-processing, forming a deep ensemble of the two co-first-place 2025 models and training a lightweight residual refiner on the ensemble's own outputs under an $\ell_1$ loss augmented with a structural-similarity term whose weight $λ$ we vary. At a moderate $λ$ the refiner improves SSIM over the ensemble, from $0.8767$ to $0.8780$ on a held-out reproduction of the official scorer and from $0.8555$ to $0.8572$ on the official validation leaderboard, with essentially no change in MSE. The gain is small but consistent, improving $62.6\%$ of the held-out cases with a signed-rank $p=2.2\times10^{-7}$, whereas over-weighting the structural term reverses it. Two ablations bound the effect. Adding any third model to the two-model ensemble degrades it, and classical unsharp masking fails to improve SSIM at any strength (best $0.8765$ against $0.8767$), so the gain reflects learned rather than indiscriminate sharpening. The result is a cheap, reproducible post-processing stage that improves an already strong ensemble without any large-scale retraining.

0.53

Assessing nnU-Net Generalization across Brain Tumor Populations in BraTS-GoAT 2026

cs.CV eess.IV ·2026-09-14 ·Tristan Kirscher, Vivian Metzger, Philippe Meyer, Xavier Coubez
published similarity 0.64
Abstract

BraTS-GoAT evaluates tumor segmentation across heterogeneous populations. We trained a conventional 3D nnU-Net on 1,351 labeled cases using five-fold cross-validation and 1,000 epochs per fold. The final predictor averaged all folds and applied test-time mirroring. On pooled official validation, global DSC values were 0.7805, 0.8288, and 0.8854 for enhancing tumor (ET), tumor core (TC), and whole tumor (WT). Under matched fold-0 inference, mean regional Dice decreased from 0.9058 on source out-of-fold (OOF) cases to 0.8310 on pooled validation (difference--0.0747). Mirroring gave small single-fold gains but no clear ensemble benefit; a residual-encoder alternative reached 0.8282 mean Dice. In labeled OOF predictions, failure cases had substantially smaller reference ET volumes; after adjustment for ET and WT volume, lower Dice remained associated with more disconnected ET components and a smaller fraction of ET contained in the largest component.

0.19