CS Paper Radar

LightMedSeg-ISLES: Stroke Lesion Segmentation with 81x Fewer Parameters than nnU-Net

Giorgi Nikvashvili, Hanxue Gu, Jie Bao, Kang Wang, Yang Yang

cs.CV cs.LG ·submitted 2026-09-09 02:49 UTC · v2

Abstract

Large networks and ensembles often lead medical image segmentation challenges, but their storage and inference demands complicate deployment. We present LightMedSeg-ISLES, a 1.26-million-parameter pipeline for T1-weighted stroke lesion segmentation in ISLES'26. On a 146-case held-out cohort, flip test-time augmentation produces 0.618 mean Dice and 0.599 lesion-wise F1. A 102.35-million-parameter nnU-Net ResEnc-L produces 0.634 Dice and 0.544 lesion-wise F1 after size filtering. LightMedSeg therefore retains 97.5\% of nnU-Net's Dice with 81.4$\times$ fewer parameters while improving lesion-wise F1 by 0.055. Its four-pass TTA operating point requires 4.7$\times$ fewer FLOPs per standardized patch than nnU-Net. It also slightly exceeds filtered UNETR++ and nnFormer. Longer training and stronger augmentation add 0.0358 Dice without increasing capacity, establishing a strong single-checkpoint alternative to much larger models.

Comment
8 pages, 3 figures. Submitted to ISLES 2026 challenge. To be published in Springer Lecture Notes in Computer Science (LNCS) as part of the SWITCH+ 2026 workshop proceedings

Closest papers

Nearest neighbours by meaning across the whole index.

SADL: A Size-Adaptive Decision Layer for Chronic Stroke Lesion Segmentation in ISLES 2026

cs.CV ·2026-10-09 ·Marek Wodzinski, Gniewosz Drwiega, Wojciech Szymanski
similarity 0.65
Abstract · ISLES 2026 Challenge Contribution

Chronic ischemic stroke lesions are difficult to segment on T1-weighted MRI. Their appearance overlaps with healthy tissue, and their volumes span four orders of magnitude, so voxel-level and lesion level metrics often disagree. We build an eleven-member nnU-Net ensemble that covers five design axes: a baseline dice + top-K loss, heavy augmentation, per-lesion volume loss re-weighting, stochastic weight averaging, and a sampling-and-architecture block that pairs cohort-balanced sampling with a residual-encoder backbone. Weighted soft-map fusion of the members feeds a tuned decision layer, SADL, that estimates lesion volume, applies an adaptive per-lesion-size threshold, prunes components by voxel count and peak probability, and adds a never-empty rescue. All fusion weights and per-bucket parameters are fitted on out-of-fold (OOF) predictions, so tuning never touches the held-out test set. On a site-disjoint 91-case holdout, SADL reaches Dice 0.7322, lesion-F1 0.7461 and PR-AUC 0.8430 when scored online with the challenge's released evaluation code. A paired non-parametric bootstrap against a reference single ensemble member confirms the lesion-F1 gain at p=0.024, and the gain is largest in the small-lesion regime, where the rescue step recovers cases that a fixed threshold would silently discard.

0.13

Native-Space 3D CarveMix for Multi-Site T1w Stroke Segmentation

eess.IV cs.CV ·2026-08-24 ·Dexter Wen Jie Teo, Kumaradevan Punithakumar
published similarity 0.63
Abstract · Accepted at the SWITCH+ Workshop (ISLES 2026 Challenge), MICCAI 2026. Springer LNCS

Segmenting ischemic stroke lesions on T1-weighted (T1w) MRI acquired across different scanners and protocols without intensity standardization is difficult because lesions are subtle and share intensity characteristics with cerebrospinal fluid. Standard deep learning architectures trained across multiple centers plateau around Dice 0.66, with acute lesions ($\le 7$ days post-stroke) performing substantially worse due to severe sample scarcity. We combine a MedNeXt-L ($k=5$) backbone with on-the-fly 3D CarveMix augmentation that pastes real lesion patches into healthy brain regions during training. By generating synthetic lesion placements dynamically within each fold with subject-level split isolation, the model sees more diverse lesion patterns without requiring pre-generated copies on disk. We evaluate on 1,453 native T1w scans from 55 clinical centers in the ISLES 2026 challenge. Our method achieves a mean 5-fold cross-validation Dice of 0.648 at 500 epochs, a +0.018 improvement over the MedNeXt-L backbone at a matched training budget (0.630)

0.31

LightMIS: Ultra-Lightweight Medical Image Segmentation Without a Stage-Wise Decoder

cs.CV ·2026-09-23 ·Andrei Arhire, Mihaela-Elena Breabăn, Radu Timofte
code/data similarity 0.63
Abstract

We present LightMIS, a scalable family of ultra-lightweight convolutional networks for 2D binary medical image segmentation without a learned stage-wise decoder. LightMIS aligns the outputs of a five-level encoder to a common resolution using Scale-Aligned Projection blocks, aggregates them once, and refines the fused representation with an Adaptive Fusion Cascade. The cascade combines Adaptive Kernel Fusion with the proposed Progressive Receptive Fusion module, which uses temporary channel expansion, complementary depthwise receptive fields, and progressive cross-branch information transfer. We evaluate LightMIS-T, LightMIS-S, and LightMIS using five-fold cross-validation under a common nnU-Net v2.3.1 protocol on DRIVE, Kvasir-SEG, DSB18, BUSI, ISIC-2017, and ISIC-2018. Full LightMIS contains 0.131 M parameters and requires 0.575 GFLOPs for a $3\times256\times256$ input, achieving modality-macro Dice and IoU scores of 86.71% and 78.99%, respectively. Mobile U-ViT obtains 86.75% Dice and 79.07% IoU, so the observed differences are 0.04 and 0.08 percentage points. Relative to Mobile U-ViT, nnWNet, and nnU-Net, LightMIS reduces parameter count by 90.58$-$99.61% and GFLOPs by 82.54$-$96.14%. On an Arm Mali-G52 MC2 GPU, all LightMIS variants achieve full GPU delegation, with median delegated latency ranging from 53.31 ms for LightMIS-T to 138.31 ms for LightMIS. These results demonstrate a favorable accuracy-complexity trade-off and on-device execution feasibility for the evaluated tasks. The code is publicly available at https://github.com/AndreiiArhire/LightMIS.

0.32

NucShare: Lightweight Nuclei Instance Segmentation with Foundation-Model Accuracy

cs.CV ·2026-09-28 ·Wenyan Li, Xiangyang Jia, Wenlong Zhong, Xu Chen
code/data similarity 0.60
Abstract · 5 pages, 3 figures, 4 tables. Submitted to IEEE International Symposium on Biomedical Imaging (ISBI 2027)

Nuclei instance segmentation is fundamental to quantitative pathology. Yet high-accuracy methods mostly build on large vision transformers (ViTs) or heavy convolutional backbones, whose parameter count and compute cost hinder deployment in clinical and edge settings. We present NucShare, a lightweight model whose shared decoder handles nuclear pixel segmentation, horizontal-vertical distance, and classification through learnable transposed convolutions for upsampling and three lightweight heads, using 37% of independent decoders' parameters with no loss in accuracy. Output-level distillation then transfers knowledge from NucShare-T (UNI2-h) to NucShare-S (ConvNeXt V2-Tiny), reducing 690.5M parameters to 34.7M. On PanNuke they reach mPQ 0.524 and 0.519, above the prior best CFR-SAM-H at 0.511, and NucShare-S surpasses HoVer-Net and Mask R-CNN by 5.6 and 15.0 points; on zero-shot MoNuSeg it attains bPQ 0.668 against CFR-SAM-H's 0.662. Code: https://github.com/L-iMeng-L/Newidea

0.33

Pre- and Post-Treatment Brain Metastases Segmentation Using nnU-Net with Post-Processing for BraTS 2026

cs.CV ·2026-09-10 ·Haobin Liu, Xin Wang
publishedbenchmarkcode/data similarity 0.59
Abstract · Accepted to MICCAI 2026 Challenge BraTS-METS

Brain metastases exhibit high inter-lesion variability in size, enhancement pattern, and post-treatment appearance, making volumetric segmentation of both pre- and post-treatment cases the central challenge of the BraTS 2026 Task 1 (Brain Metastases). We build a pragmatic pipeline on a 5-fold nnU-Net ResEnc-L ensemble, in which each fold is trained independently for 1,000 epochs with the standard Dice + cross-entropy loss on 1,296 four-modality training cases. This ensemble is followed by a rule-based post-processing cascade tuned for the lesion-wise Dice similarity coefficient (LW-DSC), a detection-oriented metric that behaves very differently from the traditional global Dice. The final pipeline reaches an LW-DSC of 0.733 / 0.751 / 0.713 / 0.549 on the enhancing tumour (ET), tumour core (TC), whole tumour (WT), and resection cavity (RC) sub-regions on the official validation leaderboard. Rather than trusting these leaderboard gains, we audit every post-processing stage with a five-fold out-of-fold (OOF) analysis with no model-training leakage over all 1,296 training cases, scored with the official BraTS evaluation code (BraTS_evaluation): it confirms two stages as robust, per-fold-consistent improvements while the third improves only the leaderboard and does not reproduce out-of-fold. We further provide a mechanistic analysis of the LW-DSC metric that explains why recall-recovering post-processing carries low risk whereas component deletion does not, and we report thirteen negative results spanning loss engineering, alternative backbones, and inference-time settings, several of which run counter to widely held intuitions. Source code is released under Apache-2.0 at https://github.com/hornbeamliu/brats2026-met.

0.48

OpenMidnight: Closing the Performance Gap Between Open and Proprietary Pathology Foundation Models

cs.CV ·2026-10-13 ·Ratna Sagari Grandhi, Anis Chihoub, Ryan Kim, Daniel Z. Kaplan, Chao Feng +13 more
code/data similarity 0.59
Abstract

Pathology foundation models offer transferable representations for a range of downstream tasks in computational pathology, but reliance on proprietary data, substantial compute requirements, and limited availability of training code and preprocessing pipelines hinder independent validation and further methodological development. We present OpenMidnight 1.1, an open-source replication and refinement of Midnight trained on approximately 12,000 publicly available whole-slide images from The Cancer Genome Atlas. Using an encoder initialized with pretrained DINOv2 weights, OpenMidnight 1.1 uses approximately 320 H100 GPU-hours for pathology pretraining, a 34-fold reduction relative to the compute reported for Midnight. Across 16 classification and four segmentation datasets in THUNDER, OpenMidnight 1.1 achieves the highest mean segmentation Dice (69.7) and ranks fourth among 14 models, ahead of Midnight, with performance that matches or exceeds models trained on substantially larger datasets in several tasks. Our ablation studies additionally examine how initialization, data volume, model size, and tissue composition affect downstream performance, providing empirical evidence to inform the development of future training recipes. Our release of the training code, preprocessing pipeline, and model weights lowers barriers to reproducible research and further development of competitive pathology foundation models.

0.50

Assessing nnU-Net Generalization across Brain Tumor Populations in BraTS-GoAT 2026

cs.CV eess.IV ·2026-09-14 ·Tristan Kirscher, Vivian Metzger, Philippe Meyer, Xavier Coubez
published similarity 0.59
Abstract

BraTS-GoAT evaluates tumor segmentation across heterogeneous populations. We trained a conventional 3D nnU-Net on 1,351 labeled cases using five-fold cross-validation and 1,000 epochs per fold. The final predictor averaged all folds and applied test-time mirroring. On pooled official validation, global DSC values were 0.7805, 0.8288, and 0.8854 for enhancing tumor (ET), tumor core (TC), and whole tumor (WT). Under matched fold-0 inference, mean regional Dice decreased from 0.9058 on source out-of-fold (OOF) cases to 0.8310 on pooled validation (difference--0.0747). Mirroring gave small single-fold gains but no clear ensemble benefit; a residual-encoder alternative reached 0.8282 mean Dice. In labeled OOF predictions, failure cases had substantially smaller reference ET volumes; after adjustment for ET and WT volume, lower Dice remained associated with more disconnected ET components and a smaller fraction of ET contained in the largest component.

0.19

TernScope: Model-Hardware Co-Design for Efficient Ternary Endoscopic Segmentation

eess.IV cs.ARcs.CV ·2026-10-21 ·Zhuoyu Wu, Wenhui Ou, Qiawei Zheng, Xuhong Qiu, Wenqi Fang +1 more
code/data similarity 0.59
Abstract · 5 pages, 4 figures, 3 tables. Code and experimental results: https://github.com/ReaganWu/TernScope

Edge medical segmentation must reconcile small model size, high accuracy, and fast inference. TernScope addresses this tradeoff through model--hardware co-design, learning a compact segmentation network whose low-bit operators also simplify hardware execution. Split-channel large-kernel blocks preserve spatial context with limited computation, while branch fusion removes redundant inference paths. Ternary Progressive Quantization-aware Training (TPQ) then adapts the fused network from deep to shallow layers, through the decoder, and finally to the input and prediction layers. All 25 convolutions use ternary weights and 8-bit activations, enabling packed storage and multiplier-free computation. The resulting model uses 0.2483 M parameters and 0.0949 GMACs while retaining competitive segmentation accuracy on in-domain and external datasets. Under the same 45 nm technology, TernScope reduces compute-array area by 88.46% compared with the original Gemmini, a systolic-array accelerator with 8-bit $\times$ 8-bit multipliers. These results demonstrate a path from accurate lightweight medical segmentation to compact low-bit hardware.

0.39