CS Paper Radar

TernScope: Model-Hardware Co-Design for Efficient Ternary Endoscopic Segmentation

Zhuoyu Wu, Wenhui Ou, Qiawei Zheng, Xuhong Qiu, Wenqi Fang, Raphaël C. -W. Phan

eess.IV cs.ARcs.CV ·submitted 2026-10-21 11:56 UTC · v1
code/data

Abstract

Edge medical segmentation must reconcile small model size, high accuracy, and fast inference. TernScope addresses this tradeoff through model--hardware co-design, learning a compact segmentation network whose low-bit operators also simplify hardware execution. Split-channel large-kernel blocks preserve spatial context with limited computation, while branch fusion removes redundant inference paths. Ternary Progressive Quantization-aware Training (TPQ) then adapts the fused network from deep to shallow layers, through the decoder, and finally to the input and prediction layers. All 25 convolutions use ternary weights and 8-bit activations, enabling packed storage and multiplier-free computation. The resulting model uses 0.2483 M parameters and 0.0949 GMACs while retaining competitive segmentation accuracy on in-domain and external datasets. Under the same 45 nm technology, TernScope reduces compute-array area by 88.46% compared with the original Gemmini, a systolic-array accelerator with 8-bit $\times$ 8-bit multipliers. These results demonstrate a path from accurate lightweight medical segmentation to compact low-bit hardware.

Comment
5 pages, 4 figures, 3 tables. Code and experimental results: https://github.com/ReaganWu/TernScope

Closest papers

Nearest neighbours by meaning across the whole index.

NucShare: Lightweight Nuclei Instance Segmentation with Foundation-Model Accuracy

cs.CV ·2026-09-28 ·Wenyan Li, Xiangyang Jia, Wenlong Zhong, Xu Chen
code/data similarity 0.68
Abstract · 5 pages, 3 figures, 4 tables. Submitted to IEEE International Symposium on Biomedical Imaging (ISBI 2027)

Nuclei instance segmentation is fundamental to quantitative pathology. Yet high-accuracy methods mostly build on large vision transformers (ViTs) or heavy convolutional backbones, whose parameter count and compute cost hinder deployment in clinical and edge settings. We present NucShare, a lightweight model whose shared decoder handles nuclear pixel segmentation, horizontal-vertical distance, and classification through learnable transposed convolutions for upsampling and three lightweight heads, using 37% of independent decoders' parameters with no loss in accuracy. Output-level distillation then transfers knowledge from NucShare-T (UNI2-h) to NucShare-S (ConvNeXt V2-Tiny), reducing 690.5M parameters to 34.7M. On PanNuke they reach mPQ 0.524 and 0.519, above the prior best CFR-SAM-H at 0.511, and NucShare-S surpasses HoVer-Net and Mask R-CNN by 5.6 and 15.0 points; on zero-shot MoNuSeg it attains bPQ 0.668 against CFR-SAM-H's 0.662. Code: https://github.com/L-iMeng-L/Newidea

0.33

LightMIS: Ultra-Lightweight Medical Image Segmentation Without a Stage-Wise Decoder

cs.CV ·2026-09-23 ·Andrei Arhire, Mihaela-Elena Breabăn, Radu Timofte
code/data similarity 0.67
Abstract

We present LightMIS, a scalable family of ultra-lightweight convolutional networks for 2D binary medical image segmentation without a learned stage-wise decoder. LightMIS aligns the outputs of a five-level encoder to a common resolution using Scale-Aligned Projection blocks, aggregates them once, and refines the fused representation with an Adaptive Fusion Cascade. The cascade combines Adaptive Kernel Fusion with the proposed Progressive Receptive Fusion module, which uses temporary channel expansion, complementary depthwise receptive fields, and progressive cross-branch information transfer. We evaluate LightMIS-T, LightMIS-S, and LightMIS using five-fold cross-validation under a common nnU-Net v2.3.1 protocol on DRIVE, Kvasir-SEG, DSB18, BUSI, ISIC-2017, and ISIC-2018. Full LightMIS contains 0.131 M parameters and requires 0.575 GFLOPs for a $3\times256\times256$ input, achieving modality-macro Dice and IoU scores of 86.71% and 78.99%, respectively. Mobile U-ViT obtains 86.75% Dice and 79.07% IoU, so the observed differences are 0.04 and 0.08 percentage points. Relative to Mobile U-ViT, nnWNet, and nnU-Net, LightMIS reduces parameter count by 90.58$-$99.61% and GFLOPs by 82.54$-$96.14%. On an Arm Mali-G52 MC2 GPU, all LightMIS variants achieve full GPU delegation, with median delegated latency ranging from 53.31 ms for LightMIS-T to 138.31 ms for LightMIS. These results demonstrate a favorable accuracy-complexity trade-off and on-device execution feasibility for the evaluated tasks. The code is publicly available at https://github.com/AndreiiArhire/LightMIS.

0.32

SPARTA: A Sparse Ternary LLM Accelerator with Adaptive Attention and Unified Datapath for Long-Context Edge Inference

cs.AR cs.AI ·2026-10-26 ·Yanzhen Zhou, Zhengyu Han, Qunyou Liu, Zheyu Yan, Weihong Xu +1 more
top venue similarity 0.62
Abstract

LLMs on edge devices are constrained by limited memory and bandwidth. Although 1.58-bit ternary weights greatly reduce model storage, long-context inference is increasingly bottlenecked by KV-cache traffic and attention. Existing accelerators also use separate datapaths for ternary linear layers and attention, incurring hardware and execution overhead. We present SPARTA, a sparse ternary LLM accelerator for efficient long-context edge inference. SPARTA integrates: (1) a phase-aware sparse dataflow exploiting heterogeneous sparsity across compute-bound prefill and memory-bound decode; (2) a unified compute fabric mapping ternary SpMM/SpMV and bit-serial attention onto shared processing elements to exploit zero-weight and zero-bit sparsity; and (3) an adaptive two-stage attention engine combining page-level Top-k selection to reduce K-cache accesses with token-level Top-p pruning to reduce V-cache traffic. SPARTA reduces KV traffic by 4.1-4.8x over full attention and 1.3-1.5x over a state-of-the-art sparse-attention scheme, with task-dependent quality loss. Compared with NVIDIA Jetson AGX Orin, SPARTA achieves 3.9x higher generation throughput and 8.3x higher end-to-end energy efficiency on average; versus AMD Ryzen 7 9700X, the gains are 5.0x and 81.7x. It also delivers 1.6-12.0x higher throughput, 2.0-4.2x higher energy efficiency, and 1.3-51.4x higher area efficiency than FIGLUT, TeLLMe, and MCBP.

0.45

NanoNet: Ultra-Lightweight Network for MRI Brain Tumor Classification toward Edge AI

cs.CV ·2026-11-08 ·Tran Nguyen-Le, Huu-Thuan Huynh, Minh-Triet Tran, Trung-Nghia Le
benchmark similarity 0.62
Abstract

Automated brain tumor classification from magnetic resonance imaging (MRI) can support accessible medical image analysis, but conventional deep learning models often exceed the resource budgets of highly constrained edge-AI platforms. We present NanoNet, an ultra-lightweight convolutional neural network designed for resourceconstrained MRI classification and motivated by future edge-AI applications. Inspired by MobileNetV2, NanoNet substantially reduces network depth, channel capacity, expansion ratios, and final feature dimensionality, resulting in only five inverted residual blocks and 8,132 parameters. We further investigate dependency-aware structured pruning, knowledge distillation, and INT8 quantization-aware training for additional compression. Experiments on the BRISC 2025 benchmark show that NanoNet achieves 92.80% accuracy and 92.97% macro F1 with 8,132 parameters and 10.498 MFLOPs. Across three compression seeds, it exceeds the mean accuracy of 70%-pruned MobileNetV2 by 5.20 percentage points while using 60.2% fewer parameters and 9.8% less computation. Converted INT8 NanoNet achieves 89.70% accuracy and 90.22% macro F1 across three QAT seeds. Earlier TensorFlow Lite measurements indicate 27.7 KB of baseline model storage, motivating future edge-AI deployment.

0.12

Ultra-Lightweight 3D Medical Image Segmentation via Knowledge Distillation in Label-Scarce Domains

cs.CV cs.AIcs.LG ·2026-11-05 ·Rahim Ullah, Hasan Abbas, Syed Waqar Nabi
code/data similarity 0.61
Abstract · This is a four pages paper having 3 figures and is submitted to ISBI2027

Mamba is a neural network architecture that reduces computational complexity, and has been shown to be effective for 3D medical image segmentation. However, existing models still remain computationally expensive. We propose compressing Mamba by distillation while achieving competitive performance. Specifically, we demonstrate compression of a 139M-parameter SegMamba-V2 teacher into a lightweight TinyUNet3D student with about 0.96M parameters, achieving about 145$\times$ compression with a performance drop of just over one Dice point. We further investigate the utility of knowledge distillation in a range of data-labeling scenarios under identical experimental settings, and show that its advantage is most prominent when labeled data is scarce. To demonstrate the generalizability of our approach, experiments are conducted on three datasets: BraTS 2023, MSD Spleen and MSD Hippocampus. The code for TinyUNet3D is publicly available at: https://github.com/2802990u/tinyunet3d-dist-kd.

0.34

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.60
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.13

CiUNet: A Hybrid Swin-CNN UNet for Medical Image Segmentation

eess.IV cs.CV ·2026-08-23 ·Bin Dong, Jinghong Chen
code/data similarity 0.60
Abstract · 14 pages, 3 figures. The demo predictor and trained weights are available at:https://github.com/ciphoBD/CiUNet

Medical image segmentation requires high accuracy and robustness, yet practical commercial deployment also demands privacy preservation and computational efficiency. In this context, the U-Net architecture, which can be inherently decoupled into independent encoder and decoder components, serves as a natural commercial choice. However, pure Transformer-based variants like Swin-UNet often suffer from insufficient local detail capture and limited interpretability. In this paper, we propose a lightweight hybrid architecture built upon the Swin-UNet framework. Our model integrates a parallel CNN encoder to complement the shallow layer reasoning of Swin Transformers with local texture features. To bridge the semantic gap and enhance fine-grained spatial detail recovery, we design an asymmetric feature fusion strategy and introduce cross-layer skip (XSkip) connections that explicitly propagate shallow CNN features into the decoder. We further incorporate novel loss functions and an auxiliary supervision head (Aux-Head) to strengthen training stability, boundary delineation, and intermediate feature interpretability. Extensive experiments on the Synapse multi-organ segmentation dataset demonstrate that our approach achieves state-of-the-art competitive Dice scores and Hausdorff distances, offering an accurate, efficient, and interpretable solution for clinical deployment.

0.32

VLCQ: Post-training quantization for deep neural networks using variable length coding

cs.CV cs.AIcs.PF ·2026-10-10 ·Reem Abdel-Salam, Ahmed H. Abdel-Gawad, Amr G. Wassal
publishedhighly cited similarity 0.60
Abstract · Published in Future Generation Computer Systems, Volume 166 (2025), Article 107654

Quantization plays a crucial role in efficiently deploying deep learning models on resource-constrained devices. Post-training quantization does not require access to the original dataset or retraining the full model. Current methods that achieve high performance close to baseline results typically require INT8 fixed-point integers. However, achieving higher model compression with lower bit-widths often leads to significant performance degradation. In this paper, we propose VLCQ, a post-training quantization method that relaxes the fixed-point encoding constraint, enabling more flexible exploration of quantization techniques through variable-length encoding. This approach achieves competitive or improved performance while reducing bit-widths, without requiring access to training data or model fine-tuning. Extensive experiments on image classification, segmentation, and object detection demonstrate that VLCQ improves model compression and accuracy compared with state-of-the-art post-training quantization approaches. For per-channel quantization, VLCQ surpasses FP32 accuracy and Piece-Wise Linear Quantization (PWLQ) on most evaluated models, achieving up to 6x compression compared with FP32 and up to 1.7x compared with PWLQ. When prioritizing compression with limited accuracy loss, VLCQ achieves up to 12.25x compression compared with FP32 with less than 4% performance degradation. For per-tensor quantization, VLCQ is competitive with Data-Free Quantization (DFQ), while providing greater flexibility to achieve lower bit rates across different tasks and models.

0.57