CS Paper Radar

LightMIS: Ultra-Lightweight Medical Image Segmentation Without a Stage-Wise Decoder

Andrei Arhire, Mihaela-Elena Breabăn, Radu Timofte

cs.CV ·submitted 2026-09-23 16:05 UTC · v2
code/data

Abstract

We present LightMIS, a scalable family of ultra-lightweight convolutional networks for 2D binary medical image segmentation without a learned stage-wise decoder. LightMIS aligns the outputs of a five-level encoder to a common resolution using Scale-Aligned Projection blocks, aggregates them once, and refines the fused representation with an Adaptive Fusion Cascade. The cascade combines Adaptive Kernel Fusion with the proposed Progressive Receptive Fusion module, which uses temporary channel expansion, complementary depthwise receptive fields, and progressive cross-branch information transfer. We evaluate LightMIS-T, LightMIS-S, and LightMIS using five-fold cross-validation under a common nnU-Net v2.3.1 protocol on DRIVE, Kvasir-SEG, DSB18, BUSI, ISIC-2017, and ISIC-2018. Full LightMIS contains 0.131 M parameters and requires 0.575 GFLOPs for a $3\times256\times256$ input, achieving modality-macro Dice and IoU scores of 86.71% and 78.99%, respectively. Mobile U-ViT obtains 86.75% Dice and 79.07% IoU, so the observed differences are 0.04 and 0.08 percentage points. Relative to Mobile U-ViT, nnWNet, and nnU-Net, LightMIS reduces parameter count by 90.58$-$99.61% and GFLOPs by 82.54$-$96.14%. On an Arm Mali-G52 MC2 GPU, all LightMIS variants achieve full GPU delegation, with median delegated latency ranging from 53.31 ms for LightMIS-T to 138.31 ms for LightMIS. These results demonstrate a favorable accuracy-complexity trade-off and on-device execution feasibility for the evaluated tasks. The code is publicly available at https://github.com/AndreiiArhire/LightMIS.

Closest papers

Nearest neighbours by meaning across the whole index.

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.68
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.13

CGDD-Net: Context-Guided Dynamic Detail Modeling for Retinal Vessel Segmentation

cs.CV ·2026-10-04 ·Xincheng Li, Xiaoqi Sheng, Xinyu Zhang
code/data similarity 0.68
Abstract

Accurate retinal vessel segmentation requires features that capture vascular geometry while preserving information for fine-scale reconstruction. We propose CGDD-Net, a context-guided dynamic detail modeling network that connects adaptive feature extraction to a shared decoder pathway. Context-Guided Scale-Adaptive Deformable Encoding (CSDE) combines fixed-grid convolution with deformable local attention to capture vascular patterns at multiple spatial extents. Spatially Adaptive Multi-Kernel Gating (SAMG) selects receptive-field responses at each location. Dynamic Cross-Scale Detail Fusion (DCDF) aligns the gated intermediate features and compresses them into an eight-channel representation, which is reused at three decoder resolutions together with selected encoder skips. This design consolidates intermediate information before decoding instead of transferring each middle-stage feature through a separate direct skip. On DRIVE, CHASE\_DB1, STARE, and HRF, CGDD-Net achieves AUC values of 0.9824, 0.9938, 0.9895, and 0.9874, with F1 scores of 0.8323, 0.8102, 0.8510, and 0.8157, respectively. The complete model contains 1.96 million trainable parameters. In cumulative ablations, the full model improves F1 over the internal baseline by 2.48, 0.61, and 3.49 percentage points on DRIVE, CHASE\_DB1, and STARE. Twelve directed cross-dataset experiments further characterize transfer without target-domain adaptation. The results support shared intermediate detail delivery as an effective, parameter-compact architecture for retinal vessel segmentation. Code is available at \url{https://github.com/lixincheng-xcl/CGDD-Net}.

0.18

CiUNet: A Hybrid Swin-CNN UNet for Medical Image Segmentation

eess.IV cs.CV ·2026-08-23 ·Bin Dong, Jinghong Chen
code/data similarity 0.68
Abstract · 14 pages, 3 figures. The demo predictor and trained weights are available at:https://github.com/ciphoBD/CiUNet

Medical image segmentation requires high accuracy and robustness, yet practical commercial deployment also demands privacy preservation and computational efficiency. In this context, the U-Net architecture, which can be inherently decoupled into independent encoder and decoder components, serves as a natural commercial choice. However, pure Transformer-based variants like Swin-UNet often suffer from insufficient local detail capture and limited interpretability. In this paper, we propose a lightweight hybrid architecture built upon the Swin-UNet framework. Our model integrates a parallel CNN encoder to complement the shallow layer reasoning of Swin Transformers with local texture features. To bridge the semantic gap and enhance fine-grained spatial detail recovery, we design an asymmetric feature fusion strategy and introduce cross-layer skip (XSkip) connections that explicitly propagate shallow CNN features into the decoder. We further incorporate novel loss functions and an auxiliary supervision head (Aux-Head) to strengthen training stability, boundary delineation, and intermediate feature interpretability. Extensive experiments on the Synapse multi-organ segmentation dataset demonstrate that our approach achieves state-of-the-art competitive Dice scores and Hausdorff distances, offering an accurate, efficient, and interpretable solution for clinical deployment.

0.32

NucShare: Lightweight Nuclei Instance Segmentation with Foundation-Model Accuracy

cs.CV ·2026-09-28 ·Wenyan Li, Xiangyang Jia, Wenlong Zhong, Xu Chen
code/data similarity 0.68
Abstract · 5 pages, 3 figures, 4 tables. Submitted to IEEE International Symposium on Biomedical Imaging (ISBI 2027)

Nuclei instance segmentation is fundamental to quantitative pathology. Yet high-accuracy methods mostly build on large vision transformers (ViTs) or heavy convolutional backbones, whose parameter count and compute cost hinder deployment in clinical and edge settings. We present NucShare, a lightweight model whose shared decoder handles nuclear pixel segmentation, horizontal-vertical distance, and classification through learnable transposed convolutions for upsampling and three lightweight heads, using 37% of independent decoders' parameters with no loss in accuracy. Output-level distillation then transfers knowledge from NucShare-T (UNI2-h) to NucShare-S (ConvNeXt V2-Tiny), reducing 690.5M parameters to 34.7M. On PanNuke they reach mPQ 0.524 and 0.519, above the prior best CFR-SAM-H at 0.511, and NucShare-S surpasses HoVer-Net and Mask R-CNN by 5.6 and 15.0 points; on zero-shot MoNuSeg it attains bPQ 0.668 against CFR-SAM-H's 0.662. Code: https://github.com/L-iMeng-L/Newidea

0.33

TernScope: Model-Hardware Co-Design for Efficient Ternary Endoscopic Segmentation

eess.IV cs.ARcs.CV ·2026-10-21 ·Zhuoyu Wu, Wenhui Ou, Qiawei Zheng, Xuhong Qiu, Wenqi Fang +1 more
code/data similarity 0.67
Abstract · 5 pages, 4 figures, 3 tables. Code and experimental results: https://github.com/ReaganWu/TernScope

Edge medical segmentation must reconcile small model size, high accuracy, and fast inference. TernScope addresses this tradeoff through model--hardware co-design, learning a compact segmentation network whose low-bit operators also simplify hardware execution. Split-channel large-kernel blocks preserve spatial context with limited computation, while branch fusion removes redundant inference paths. Ternary Progressive Quantization-aware Training (TPQ) then adapts the fused network from deep to shallow layers, through the decoder, and finally to the input and prediction layers. All 25 convolutions use ternary weights and 8-bit activations, enabling packed storage and multiplier-free computation. The resulting model uses 0.2483 M parameters and 0.0949 GMACs while retaining competitive segmentation accuracy on in-domain and external datasets. Under the same 45 nm technology, TernScope reduces compute-array area by 88.46% compared with the original Gemmini, a systolic-array accelerator with 8-bit $\times$ 8-bit multipliers. These results demonstrate a path from accurate lightweight medical segmentation to compact low-bit hardware.

0.39

When Fusion Fails: Corruption-Aware Rebalanced Fusion for Multi-Modal Medical Image Segmentation

cs.CV ·2026-09-09 ·Yuchen Pei, Xiaoyu Hu, Yixiong Zou, Dingwen Hu, Hui Chu +3 more
top venuecode/data similarity 0.66
Abstract · Accepted by ACM Multimedia (ACM MM 2026)

Multi-modal medical image segmentation leverages complementary diagnostic information, yet fusion can underperform single-modality baselines when spatially aligned inputs differ in quality. Here, "corruption" primarily denotes resolution-induced degradation rather than misalignment or complete modality absence, while synthetic noise is evaluated only as an auxiliary setting. We identify a critical optimization-inference inconsistency: degraded modalities can receive weak training updates yet substantially affect predictions, indicating active interference with fusion. We attribute this failure to resampling-induced feature corruption and optimization bias, where noisy features propagate through skip connections and encourage unreliable modality selection. We therefore propose CoReFuse-Med, a Corruption-aware Rebalanced Fusion framework that suppresses corruption during feature transmission and rebalances modality contributions during high-level fusion. Experiments on EPVS, BraTS, and WMH, including multiple Z-axis slice-retention ratios and an auxiliary noise test, demonstrate improved accuracy and robustness under modality-quality discrepancies. Our code is available at https://github.com/lrever/CoReFuse.

0.53

VGG16-MCA UNet: Whole-Tumor Segmentation in 2D FLAIR MRI with Decoder-Side Channel Attention

eess.IV cs.CV ·2026-09-20 ·Shubham Gajjar, Deep Joshi, Avi Poptani, Vishal Barot
benchmarktheorycode/data similarity 0.66
Abstract · 22 pages, 7 figures, 4 tables. Code and data splits: https://github.com/ShubhamGajjar/vgg16-mca-unet

Automated brain tumor segmentation supports diagnosis, treatment planning, and monitoring of disease progression, but building models that generalize across heterogeneous tumors and limited annotated data remains difficult. We present VGG16-MCA UNet, a hybrid architecture pairing an ImageNet-pretrained VGG16 encoder with a decoder in which a Multi-Channel Attention (MCA) module recalibrates features after each skip-connection fusion, trained with the Focal Tversky loss to counter severe foreground-background imbalance. We evaluate the model as a 2D, FLAIR-only, whole-tumor segmenter on tumor-positive slices from two public datasets: the BraTS 2020 benchmark and the LGG MRI Segmentation dataset. Using 5-fold cross-validation and a single network formed by averaging the weights of the five fold models, the method attains an aggregate pixel-level Dice (F1) of 95.10% on our held-out BraTS 2020 split and 88.32% on LGG. These scores are computed over all test pixels pooled into a single confusion matrix rather than averaged per case, and are therefore not directly comparable to the per-case mean Dice used in the BraTS challenge protocol. All partitions were drawn over individual slices rather than over patients, so every patient contributes slices to both training and test; the figures above therefore measure interpolation within known patients and should be read as an upper bound rather than as generalization to new ones. The model segments a 256x256 slice in 66.32 ms on a single 6 GB NVIDIA RTX 2060, approximately 8 ms more than an equivalent VGG16-UNet without MCA. We release the split records and report the protocol in full, with the aim of providing a precisely specified and reproducible 2D FLAIR baseline.

0.23

CoMLP: Cooperatively-Gated MLPs for Fine-Grained Cross-Modal Information Fusion in Medical Image Segmentation

cs.CV ·2026-09-04 ·Mingyuan Meng, Shuchang Ye, Mingjian Li, Zhenyu Zhao, Jinman Kim +1 more
similarity 0.66
Abstract

Multi-modal medical images and clinical reports provide complementary anatomical, functional, and semantic information for medical image segmentation. Effectively exploiting these heterogeneous sources requires fine-grained cross-modal information fusion that preserves subtle spatial details while capturing semantic dependencies across modalities. Existing fusion approaches frequently rely on cross-attention, whose computational burden increases rapidly with spatial resolution, making dense cross-modal interaction difficult on high-resolution feature maps, particularly for volumetric medical images. In this work, we propose CoMLP, a cooperatively-gated MLP module for fine-grained cross-modal information fusion in medical image segmentation. CoMLP models cross-modal dependencies through cooperative cross-gating, built upon complementary regional and dilated MLP interactions, to capture local and global cross-modal dependencies. We further develop a multi-source fusion architecture in which CoMLP performs both inter-image fusion across imaging modalities and vision-language fusion between visual features and textual reports, enabling heterogeneous information to be integrated without relying on dense cross-attention. Extensive experiments on five medical segmentation benchmarks, covering 2D/3D images, clinical reports, multiple imaging modalities, and diverse anatomical regions, demonstrate consistent improvements over state-of-the-art multi-modal and language-guided segmentation methods. Ablation studies further show that fine-grained interaction at high spatial resolutions and complementary local-global fusion are critical to the performance gains. These results demonstrate the potential of MLP-based interaction as an effective alternative for fine-grained cross-modal information fusion in medical image segmentation.

0.28