CS Paper Radar

CGDD-Net: Context-Guided Dynamic Detail Modeling for Retinal Vessel Segmentation

Xincheng Li, Xiaoqi Sheng, Xinyu Zhang

cs.CV ·submitted 2026-10-04 09:22 UTC · v1
code/data

Abstract

Accurate retinal vessel segmentation requires features that capture vascular geometry while preserving information for fine-scale reconstruction. We propose CGDD-Net, a context-guided dynamic detail modeling network that connects adaptive feature extraction to a shared decoder pathway. Context-Guided Scale-Adaptive Deformable Encoding (CSDE) combines fixed-grid convolution with deformable local attention to capture vascular patterns at multiple spatial extents. Spatially Adaptive Multi-Kernel Gating (SAMG) selects receptive-field responses at each location. Dynamic Cross-Scale Detail Fusion (DCDF) aligns the gated intermediate features and compresses them into an eight-channel representation, which is reused at three decoder resolutions together with selected encoder skips. This design consolidates intermediate information before decoding instead of transferring each middle-stage feature through a separate direct skip. On DRIVE, CHASE\_DB1, STARE, and HRF, CGDD-Net achieves AUC values of 0.9824, 0.9938, 0.9895, and 0.9874, with F1 scores of 0.8323, 0.8102, 0.8510, and 0.8157, respectively. The complete model contains 1.96 million trainable parameters. In cumulative ablations, the full model improves F1 over the internal baseline by 2.48, 0.61, and 3.49 percentage points on DRIVE, CHASE\_DB1, and STARE. Twelve directed cross-dataset experiments further characterize transfer without target-domain adaptation. The results support shared intermediate detail delivery as an effective, parameter-compact architecture for retinal vessel segmentation. Code is available at \url{https://github.com/lixincheng-xcl/CGDD-Net}.

Closest papers

Nearest neighbours by meaning across the whole index.

U-PEN Mamba: Progressive Expansion with Selective State-Space Modeling for Efficient Retinal Vessel Segmentation

cs.CV ·2026-09-21 ·Abel A. Reyes-Angulo, Sidike Paheding, Vijayan K. Asari, Mohammad Alam, Jeevan Devagiri
publishedcode/data similarity 0.77
Abstract

Accurate retinal vessel segmentation is important for computer-aided ophthalmic analysis, yet thin vessels, low contrast, and severe foreground-background imbalance remain challenging for encoder-decoder networks. This paper presents U-PEN Mamba, a U-shaped retinal vessel segmentation architecture that couples progressive nonlinear feature expansion with selective state-space modeling. The proposed network enriches local vessel responses with progressive expansion, models long-range spatial dependencies through a Mamba Global Context (MGC) block with linear sequence complexity, and uses attention-based decoder fusion to recover fine vascular boundaries. We evaluate U-PEN Mamba on CHASE DB1 and DRIVE using a consistent patch-based preprocessing pipeline and compare it with convolutional, attention-based, transformer-based, and Mamba-based segmentation baselines. U-PEN Mamba obtains the best mean intersection over union among the compared methods, achieving 0.8394 on CHASE DB1 and 0.8221 on DRIVE, with Dice scores of 0.8187 and 0.8078, respectively, using 21.6M trainable parameters. Ablation studies show that the MGC block contributes the largest gain over the U-Net baseline, while projection dimension and state size provide practical accuracy-efficiency control. These results indicate that selective state-space modeling is a promising global-context mechanism for parameter-efficient retinal vessel segmentation. Code is available at: https://github.com/areyesan/UPEN_Mamba.

0.45

Topology-Aware Parameter-Efficient Adaptation for Cross-Dataset Retinal Vessel Segmentation

cs.CV ·2026-08-10 ·Yongsong Huang, Tomo Miyazaki, Kai Xu, Xiaofeng Liu, Yaohou Fan +1 more
similarity 0.71
Abstract · This manuscript is currently under peer review. Copyright may subsequently be transferred to the publisher, after which the availability of …

Retinal vessel segmentation in multi-domain deployment requires a source model to adapt to domains that differ in imaging conditions and annotation conventions. Conventional parameter-efficient fine-tuning reduces target-specific storage, but its highly restricted adaptation subspace can be insufficient for reconstructing thin, connected vascular structures. We therefore ask how target-specific capacity should be allocated so that topology-aware supervision remains effective under a strict per-domain parameter budget. Based on this principle, we propose TAPDecoderFT, a topology-responsive, role-structured adaptation framework. Specifically, TAPDecoderFT shares a fixed source parameter state across deployment domains, uses low-rank residuals for target-specific private/fusion feature mixing, and retains a trainable dense-reconstruction path comprising the decoder, output head, and refinement module. To promote structurally faithful predictions, the compact target state is jointly optimized with a region-overlap and topology-aware objective that encourages centerline continuity and thin-branch recovery. It improves both DSC and clDice over GenericLoRA-r4 and narrow TAP-r4 in all six directions and is comparable to full fine-tuning.

0.04

LightMIS: Ultra-Lightweight Medical Image Segmentation Without a Stage-Wise Decoder

cs.CV ·2026-09-23 ·Andrei Arhire, Mihaela-Elena Breabăn, Radu Timofte
code/data similarity 0.68
Abstract

We present LightMIS, a scalable family of ultra-lightweight convolutional networks for 2D binary medical image segmentation without a learned stage-wise decoder. LightMIS aligns the outputs of a five-level encoder to a common resolution using Scale-Aligned Projection blocks, aggregates them once, and refines the fused representation with an Adaptive Fusion Cascade. The cascade combines Adaptive Kernel Fusion with the proposed Progressive Receptive Fusion module, which uses temporary channel expansion, complementary depthwise receptive fields, and progressive cross-branch information transfer. We evaluate LightMIS-T, LightMIS-S, and LightMIS using five-fold cross-validation under a common nnU-Net v2.3.1 protocol on DRIVE, Kvasir-SEG, DSB18, BUSI, ISIC-2017, and ISIC-2018. Full LightMIS contains 0.131 M parameters and requires 0.575 GFLOPs for a $3\times256\times256$ input, achieving modality-macro Dice and IoU scores of 86.71% and 78.99%, respectively. Mobile U-ViT obtains 86.75% Dice and 79.07% IoU, so the observed differences are 0.04 and 0.08 percentage points. Relative to Mobile U-ViT, nnWNet, and nnU-Net, LightMIS reduces parameter count by 90.58$-$99.61% and GFLOPs by 82.54$-$96.14%. On an Arm Mali-G52 MC2 GPU, all LightMIS variants achieve full GPU delegation, with median delegated latency ranging from 53.31 ms for LightMIS-T to 138.31 ms for LightMIS. These results demonstrate a favorable accuracy-complexity trade-off and on-device execution feasibility for the evaluated tasks. The code is publicly available at https://github.com/AndreiiArhire/LightMIS.

0.32

Steer the Sampling, Not the Kernel Grid: Geometry-Guided Sampling Operator for Volumetric Segmentation

cs.CV ·2026-08-26 ·Sizhe Wang, Himashi Peiris, Zhaolin Chen
top venue similarity 0.67
Abstract · Accepted at MICCAI 2026

Accurate 3D segmentation is central to quantitative lesion assessment and anatomy mapping for clinical planning and follow-up. Thin, elongated, and fine anatomical/pathological structures (e.g., vessels) are a particularly challenging case: a one-voxel boundary error can disconnect a branch and change clinically relevant topology. In encoder-decoder networks (e.g., U-Net), repeated downsampling and fixed-grid convolution blur or alias fine structures and weaken orientation cues, so early mistakes propagate across scales. We propose a geometry-guided local operator that steers where features are sampled, rather than deforming convolutional kernels, under a single formulation for both feature refinement (stride 1) and resolution reduction (stride > 1). At each voxel, it predicts a local orientation and bounded step sizes, samples symmetrically along these directions, and transforms paired samples into compact geometric and boundary cues with lightweight mixing; a cross-scale consensus aligns encoder and decoder features at skip connections to reduce geometric mismatch. Replacing all stride 1 and stride 2 operators in a 3D U-Net yields consistent improvements on BraTS, MSD Hepatic Vessel, and TDSC-ABUS, with notably better boundary metrics (e.g., BraTS Dice 86.1 to 88.9, HD95 7.1 to 6.2; TDSC-ABUS HD95 39.1 to 27.8) while reducing parameters from 2.3M to 0.8M. We further demonstrate that the operator can be integrated into other backbones (e.g., nnU-Net, Swin-UNETR, and MedNeXt) without changing their macro-architectures while providing consistent performance gains.

0.24

OptiModNet: A UNet-Transformer Hybrid with Grouped-Query and Channel Attention for Optic Disc and Cup Segmentation

cs.CV cs.AI ·2026-08-19 ·Soumili Ghosh, Debapriya Roy, Aryan Das, Bikash Santra
code/data similarity 0.67
Abstract

Precise segmentation of the optic disc and cup is critical for the early detection and diagnosis of glaucoma. However, achieving consistently high performance across datasets while maintaining low computational requirements remains a significant challenge. In glaucoma detection, low-computation methods are crucial for enabling rapid, large-scale screening and facilitating deployment in resource-limited clinical environments. While deep learning models such as UNets, Vision Transformers (ViTs), and Diffusion models have demonstrated strong segmentation performance but these methods often come with substantial computational overhead. UNets are efficient at capturing local features but are limited in modeling global contextual information. Conversely, ViTs excel at long-range dependency modeling but are computationally intensive. Hybrid architectures, such as UNetR, which combine transformer-based encoders with UNet-style decoders, have shown improved performance but while incurring additional complexity. Considering these, in this work, we propose OptiModNet, a light weight novel hybrid architecture tailored for optic disc and cup segmentation. The model integrates diverse attention mechanisms at multiple stages of the network to enhance both local and global feature representation. We include an Aggregated Pyramid Loss that supervises predictions at multiple decoder depths, to promote better gradient flow and structural consistency. We evaluate OptiModNet on the REFUGE2 dataset for both optic disc and cup segmentation tasks. Our method achieves state-of-the-art performance, exceeding existing approaches by over 2.5\%, while maintaining high efficiency with only 3.73 GFLOPs and 1.93M parameters. The code is available at https://github.com/SG1947/OptiModNet.

0.24

RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM

cs.CV cs.LG ·2026-11-09 ·Jaafar M. Al-Ghabban, Mohammad Reza Mohammadi
similarity 0.66
Abstract

Retinal disease monitoring with optical coherence tomography angiography (OCTA) relies on segmentation of vessels and the foveal avascular zone (FAZ). Promptable models such as SEEM (Segment Everything Everywhere All at Once) allow click-based refinement, but without adaptation SEEM segments thin vessels poorly and needs many clicks. Fully fine-tuning its 342 million parameters on a few hundred images is costly and risks overfitting, and parameter-efficient methods such as low-rank adaptation (LoRA) usually adapt only the encoder. Yet SEEM reads every candidate mask from one feature map at quarter resolution, too coarse for vessels one to three pixels wide. This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution. Each candidate accesses them through its own vector and a zero-initialised projection, so the model starts exactly as SEEM. The encoder branch, a standard rank-1 LoRA, supplies the information needed to tell arteries from veins. RBA adds 0.47 million trainable parameters. Under simulated error-driven clicks, with the ground truth used only to place them, RBA outperforms LoRA, Conv-LoRA andAdaptFormer on OCTA-500 3mmlarge vessels. Averaged over three seeds, it reaches an intersection over union (IoU) of 85.16% and a Dice score of 91.93%, 2.90 and 1.72 percentage points above Conv-LoRA. On the 6 mm subset, one run gives margins of 4.35 and 2.76 points. The gain extends to arteries, veins and ROSE-O but not to the FAZ. In SEEM, adaptation capacity pays more at the mask read-out than in the encoder.

0.25

Feature Reconfiguration With Visual Prior for Medical Lesion Segmentation

cs.AI eess.IV ·2026-09-03 ·Yinan Liu, Jiankang Hong, Zhen Gao, Ye Luo
similarity 0.66
Abstract · 9 pages 10figures

Lesion segmentation in medical images plays a critical role in clinical diagnosis and treatment planning. Despite significant advances, lesion segmentation remains challenging due to two major factors: (1) complex background interference; (2) diverse lesion morphology. Existing encoder-decoder based methods mainly focus on enhancing feature extraction or redesigning decoding strategies. However, they lack early prior guidance and feature reconfiguration during the encoding stage, limiting their effectiveness in handling these challenges. To address these limitations, we propose FreNet, a feature reconfiguration framework with visual priors, which performs pixel-level reconfiguration before encoding and feature-level reconfiguration during encoding for precise medical lesion segmentation. To suppress background responses, we propose an Implicit Prior Neural Network (IPNN), which models a continuous spatial field and leverages visual prior from SAM to reconfigure input image before encoding stage. To better handle diverse lesion morphology, we design a Dual-domain Feature Reconfiguration (DFR) module to progressively reconfigure backbone features during encoding stage. Within DFR, the Frequency Decoupling Module (FDM) decouples backbone features in frequency domain to enhance foreground-background discriminability, while the Spatial Localization Module (SLM) spatially relocates and improving spatial stability after frequency decoupling. Extensive experiments on 9 medical image segmentation benchmarks across three imaging modalities demonstrate that FreNet significantly outperforms state-of-the-art (SOTA) methods. On the challenging ETIS dataset, our method achieves Dice improvements of 5.0% over SOTA method and 7.2% over SAM.

0.24

Disentangling Co-Occurring Retinal Pathologies with Saliency-Guided Sparse Expert Routing

cs.CV cs.LGeess.IVeess.SP ·2026-08-10 ·Nagur Shareef Shaik, Jeongwoo Park, Yeong-Jin Kim, Jaeuk Jung, Hyunjung Oh +1 more
publishedbenchmark similarity 0.66
Abstract · Accepted at 2026 IEEE International Workshop on Machine Learning for Signal Processing

Retinal fundus images frequently exhibit multiple co-occurring pathologies, yet standard deep learning classifiers apply static, identical computation to every image regardless of the underlying disease distribution. We propose a novel architecture that resolves this via sparse conditional computation, pairing a Guided Context Gating (GCG) spatial attention front-end with a sparsely-routed Mixture-of-Experts (MoE) block operating over feature tokens. Crucially, this routing yields an interpretable, data-driven decomposition. Expert allocation is significantly disease-dependent (p < 0.001), with the healthy Normal state and morphologically distinct pathologies (e.g., ERM, AMD) isolating to dedicated experts. On a five-class, patient-disjoint 5-fold cross-validation benchmark, our model achieves 0.912 +/- 0.008 macro AUC and 0.653 +/- 0.014 macro F1. Furthermore, Grad-CAM++ and post-MoE t-SNE visualizations confirm that expert routing aligns with localized lesions and geometrically maps co-occurring cases between their constituent clusters, positioning sparse MoE as an interpretable approach to multi-disease retinal screening.

0.20