CS Paper Radar

Topology-Aware Parameter-Efficient Adaptation for Cross-Dataset Retinal Vessel Segmentation

Yongsong Huang, Tomo Miyazaki, Kai Xu, Xiaofeng Liu, Yaohou Fan, Shinichiro Omachi

cs.CV ·submitted 2026-08-10 06:04 UTC · v1

Abstract

Retinal vessel segmentation in multi-domain deployment requires a source model to adapt to domains that differ in imaging conditions and annotation conventions. Conventional parameter-efficient fine-tuning reduces target-specific storage, but its highly restricted adaptation subspace can be insufficient for reconstructing thin, connected vascular structures. We therefore ask how target-specific capacity should be allocated so that topology-aware supervision remains effective under a strict per-domain parameter budget. Based on this principle, we propose TAPDecoderFT, a topology-responsive, role-structured adaptation framework. Specifically, TAPDecoderFT shares a fixed source parameter state across deployment domains, uses low-rank residuals for target-specific private/fusion feature mixing, and retains a trainable dense-reconstruction path comprising the decoder, output head, and refinement module. To promote structurally faithful predictions, the compact target state is jointly optimized with a region-overlap and topology-aware objective that encourages centerline continuity and thin-branch recovery. It improves both DSC and clDice over GenericLoRA-r4 and narrow TAP-r4 in all six directions and is comparable to full fine-tuning.

Comment
This manuscript is currently under peer review. Copyright may subsequently be transferred to the publisher, after which the availability of this version may be subject to the publisher's policy

Closest papers

Nearest neighbours by meaning across the whole index.

CGDD-Net: Context-Guided Dynamic Detail Modeling for Retinal Vessel Segmentation

cs.CV ·2026-10-04 ·Xincheng Li, Xiaoqi Sheng, Xinyu Zhang
code/data similarity 0.71
Abstract

Accurate retinal vessel segmentation requires features that capture vascular geometry while preserving information for fine-scale reconstruction. We propose CGDD-Net, a context-guided dynamic detail modeling network that connects adaptive feature extraction to a shared decoder pathway. Context-Guided Scale-Adaptive Deformable Encoding (CSDE) combines fixed-grid convolution with deformable local attention to capture vascular patterns at multiple spatial extents. Spatially Adaptive Multi-Kernel Gating (SAMG) selects receptive-field responses at each location. Dynamic Cross-Scale Detail Fusion (DCDF) aligns the gated intermediate features and compresses them into an eight-channel representation, which is reused at three decoder resolutions together with selected encoder skips. This design consolidates intermediate information before decoding instead of transferring each middle-stage feature through a separate direct skip. On DRIVE, CHASE\_DB1, STARE, and HRF, CGDD-Net achieves AUC values of 0.9824, 0.9938, 0.9895, and 0.9874, with F1 scores of 0.8323, 0.8102, 0.8510, and 0.8157, respectively. The complete model contains 1.96 million trainable parameters. In cumulative ablations, the full model improves F1 over the internal baseline by 2.48, 0.61, and 3.49 percentage points on DRIVE, CHASE\_DB1, and STARE. Twelve directed cross-dataset experiments further characterize transfer without target-domain adaptation. The results support shared intermediate detail delivery as an effective, parameter-compact architecture for retinal vessel segmentation. Code is available at \url{https://github.com/lixincheng-xcl/CGDD-Net}.

0.18

U-PEN Mamba: Progressive Expansion with Selective State-Space Modeling for Efficient Retinal Vessel Segmentation

cs.CV ·2026-09-21 ·Abel A. Reyes-Angulo, Sidike Paheding, Vijayan K. Asari, Mohammad Alam, Jeevan Devagiri
publishedcode/data similarity 0.67
Abstract

Accurate retinal vessel segmentation is important for computer-aided ophthalmic analysis, yet thin vessels, low contrast, and severe foreground-background imbalance remain challenging for encoder-decoder networks. This paper presents U-PEN Mamba, a U-shaped retinal vessel segmentation architecture that couples progressive nonlinear feature expansion with selective state-space modeling. The proposed network enriches local vessel responses with progressive expansion, models long-range spatial dependencies through a Mamba Global Context (MGC) block with linear sequence complexity, and uses attention-based decoder fusion to recover fine vascular boundaries. We evaluate U-PEN Mamba on CHASE DB1 and DRIVE using a consistent patch-based preprocessing pipeline and compare it with convolutional, attention-based, transformer-based, and Mamba-based segmentation baselines. U-PEN Mamba obtains the best mean intersection over union among the compared methods, achieving 0.8394 on CHASE DB1 and 0.8221 on DRIVE, with Dice scores of 0.8187 and 0.8078, respectively, using 21.6M trainable parameters. Ablation studies show that the MGC block contributes the largest gain over the U-Net baseline, while projection dimension and state size provide practical accuracy-efficiency control. These results indicate that selective state-space modeling is a promising global-context mechanism for parameter-efficient retinal vessel segmentation. Code is available at: https://github.com/areyesan/UPEN_Mamba.

0.45

FPG-Seg: Annotation-free Retinal Vessel Topology Segmentation

cs.CV ·2026-10-15 ·James Willoughby, Irina Voiculescu
benchmark similarity 0.67
Abstract

State-of-the art approaches to retinal vessel segmentation typically require extensive annotations, a highly time-consuming process, reliant on clinical expertise. We present FPG-Seg, an annotation-free pipeline for retinal vessel segmentation combining classical vesselness filtering, Bayesian deep learning and topology-aware graph reconstruction to segment retinal vessel topology without manual labels. Tested across four widely used benchmark datasets for retinal vessel segmentation, FPG-Seg attains a clDice of $0.74{-}0.78$, representing $86{-}98\%$ of the performance of an equivalent fully-supervised baseline, despite using no manual annotations for training or hyperparameter tuning. As part of this work, we also provide, to our knowledge, the first performance benchmark of an annotation-free vessel segmentation method on FIVES.

0.18

Evidence-Guided Selection of Retinal Vessel Segmentation Pipelines: A Cross-Dataset Benchmark of Performance, Structure, Failure Modes, and Reproducibility

cs.CV ·2026-10-22 ·Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo +2 more
benchmark similarity 0.65
Abstract

Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structural fidelity, cross-dataset robustness, and application-specific error costs. We evaluated five executable binary vessel-segmentation pipelines (FSG-Net, SA-UNetv2, DCP-1024, GAVE, and FR-UNet) on 244 images from six public datasets using pixel-level agreement, cross-dataset stability, thin-vessel retention, structural metrics, error composition, and available computational evidence. Results were aggregated with equal weighting across datasets. No pipeline was optimal in every setting. FSG-Net achieved the highest equal-dataset mean Macro-F1 (0.77), IoU (0.63), clDice (0.83), and Skeleton F1 (0.78), whereas SA-UNetv2 achieved the highest mean sensitivity (0.85) and Thin-Vessel Sensitivity (0.63). Differences across datasets were often larger than those among the leading pipelines, and errors shared by all five methods were concentrated near annotated vessel boundaries and faint peripheral vessels. In an ancillary analysis on 45 HRF images, segmentation masks were converted into 11 ring-wise vascular features for leave-one-out classification. Controlled perturbations showed that local mask errors can be amplified in downstream features, while targeted stabilization reduced sensitivity for five features. The results support task-conditioned, benchmark-relative pipeline selection rather than a single universal ranking and highlight the need to validate the selected pipeline on the intended target domain.

0.09

Skeleton-Guided Progressive Test-Time Adaptation for Thin Curvilinear Structures

cs.CV eess.IV ·2026-10-08 ·Boa Jang, JunGyu Lee, Gwanho Lee, Jinwook Choi, Young-Gon Kim
code/data similarity 0.65
Abstract · 9 pages, 6 figures

Accurate segmentation of thin curvilinear structures is vital for various real-world applications, from vessel analysis to road extraction. Yet their intricate geometry makes even minor pixel-wise errors enough to break the global topology, and this structural fragility turns severe domain shifts into catastrophic failures. The difficulty is most acute under cross-modality gaps, where the imaging process itself differs fundamentally between source and target. While test-time adaptation (TTA) offers a practical source-free remedy, existing methods adapt feature statistics and confidence, neither of which constrains connectivity, and thus degrade under such extreme gaps. To address this, we propose Skeleton-Guided Progressive Test-Time Adaptation (SGP-TTA). Progressive Batch Normalization (ProgBN) shifts normalization from frozen source statistics toward current target estimates under a sample-count schedule, so that the source-target balance follows the stage of adaptation rather than a fixed coefficient. Consensus Skeleton Recall (CSR) then derives a structural target from geometrically aligned multi-view predictions and updates only the BN affine parameters to preserve connected structures. Extensive experiments show that SGP-TTA consistently outperforms existing TTA methods in topological connectivity, with the largest margins under cross-modality shift. The project page is available at https://boa-jang.github.io/SGP-TTA.

0.44

O2D-MedNet: An Optimization-Aware Dual-Domain Framework for Robust Medical Image Segmentation

cs.CV ·2026-10-26 ·Shipeng Hu, Miaohui Wang, Jing Qin, Sukun Tian, Yuchun Sun
similarity 0.65
Abstract · 16 pages, 12 figures

Medical image segmentation (MIS) remains challenging due to composite degradations and multi-scale geometric variations, which jointly impair lesion-background separability, structural consistency, and optimization stability. Existing single-stream frameworks entangle heterogeneous cues within a single representation pathway, while hybrid-stream approaches often rely on generic or static fusion, limiting effective coordination across domains and failing to explicitly address optimization instability. To overcome these limitations, we propose a new optimization-aware dual-domain framework for MIS (O2D-MedNet). First, a degradation-aware dualdomain interaction (DDI) module integrates Fourier - and Wavelet-domain features to suppress degradation-sensitive responses while preserving structural and fine-detail information. Second, a cross-backbone contour-guided fusion (CGF) module enables selective interaction between CNN-based local detail modeling and visual state-space-based global structure modeling, improving boundary accuracy and representation consistency. Third, a gradient-context optimization (GCO) strategy stabilizes training by adaptively adjusting learning dynamics based on loss trends and gradient statistics, mitigating instability caused by class imbalance and heterogeneous sample difficulty. Extensive experiments on six benchmarks demonstrate consistent improvements over state-of-the-art MIS methods across multiple imaging modalities. Further analyses confirm enhanced sensitivity, structural consistency, and optimization stability, validating the effectiveness of the proposed O2D-MedNet for robust MIS under heterogeneous conditions.

0.20

Benchmarking Self-Supervised 3D Medical Vision Foundation Models and Transferability Estimation

cs.CV cs.AI ·2026-10-13 ·Jiaqi Tang, Yu Wang, Yang Liu, Jing Tao, Fandong Zhang +5 more
benchmark similarity 0.65
Abstract

Self-supervised pretraining has expanded the pool of 3D medical foundation models, but published evaluations use different datasets, endpoints and fine-tuning protocols. Models also differ in architecture, pretraining objective and data, while downstream targets range from voxel-level masks to patient-level diagnoses and outcomes. As a result, published findings provide little directly comparable evidence for choosing a model for a new task. Direct comparison of adaptation performance requires fine-tuning candidates on labelled target data, at substantial computational cost. We benchmark 23 candidates across the same 14 segmentation, classification and regression tasks spanning multiple anatomies and modalities. No candidate ranked among the top three across all segmentation tasks or across all classification and regression tasks; a convolutional encoder could outperform a transformer trained with the same objective on one task but underperform it on another. We benchmark transferability estimators against the fine-tuned rankings and find that their agreement varies across dense segmentation, classification and regression. InsightRank uses task-appropriate frozen-feature statistics and architecture-aware pairwise comparisons to rank candidates before fine-tuning. Across the 23-model pool, mean Kendall tau-b was 0.431 for segmentation and 0.352 for classification and regression. The segmentation Top 3 contained a task winner on four of nine tasks; the image-level Top 3 contained none on the five tasks, despite better full-ranking agreement than the matched conventional estimators. A three-model shortlist reduced recorded extraction-plus-training job time by 85.8% across seven segmentation tasks. Together, the benchmark provides a common reference for model selection and InsightRank offers a lower-cost way to prioritize fine-tuning, with shortlist performance that differs by target type.

0.20

Where to Predict in Retinal OCT? Anatomy-Guided Target Selection for I-JEPA

cs.CV ·2026-11-12 ·Yunchu Feng, Wai Tak Lau, Kaveri A. Thakoor
published similarity 0.65
Abstract · 18 pages. Accepted as a poster at the GenAI for Health Workshop at NeurIPS 2026 (non-archival)

Self-supervised learning aims to learn meaningful representations from unlabeled data, potentially allowing models to capture subtle anatomical variations across patients and reduce the amount of labeled data needed. Image-based Joint-Embedding Predictive Architecture (I-JEPA) learns by predicting target-region representations from visible context rather than reconstructing pixels. However, its uniform target placement does not account for the anatomical structure of retinal OCT, where retinal tissue occupies only part of each B-scan. We investigate anatomy-guided target selection using image intensity and predicted retinal segmentation while retaining the I-JEPA architecture and latent prediction objective. We compare anatomy-guided rectangular targets, anatomy-shaped targets and coverage-constrained placement with uniform masking, and evaluate the learned representations using linear probing for glaucoma classification on FairVision. We found that rectangular targets guided by image intensity achieved the highest linear-probe AUC in our comparisons. We show that anatomically meaningful target selection is promising for retinal OCT representation learning, while greater anatomical specificity did not consistently improve performance.

0.35