CS Paper Radar

Skeleton-Guided Progressive Test-Time Adaptation for Thin Curvilinear Structures

Boa Jang, JunGyu Lee, Gwanho Lee, Jinwook Choi, Young-Gon Kim

cs.CV eess.IV ·submitted 2026-10-08 02:19 UTC · v1
code/data

Abstract

Accurate segmentation of thin curvilinear structures is vital for various real-world applications, from vessel analysis to road extraction. Yet their intricate geometry makes even minor pixel-wise errors enough to break the global topology, and this structural fragility turns severe domain shifts into catastrophic failures. The difficulty is most acute under cross-modality gaps, where the imaging process itself differs fundamentally between source and target. While test-time adaptation (TTA) offers a practical source-free remedy, existing methods adapt feature statistics and confidence, neither of which constrains connectivity, and thus degrade under such extreme gaps. To address this, we propose Skeleton-Guided Progressive Test-Time Adaptation (SGP-TTA). Progressive Batch Normalization (ProgBN) shifts normalization from frozen source statistics toward current target estimates under a sample-count schedule, so that the source-target balance follows the stage of adaptation rather than a fixed coefficient. Consensus Skeleton Recall (CSR) then derives a structural target from geometrically aligned multi-view predictions and updates only the BN affine parameters to preserve connected structures. Extensive experiments show that SGP-TTA consistently outperforms existing TTA methods in topological connectivity, with the largest margins under cross-modality shift. The project page is available at https://boa-jang.github.io/SGP-TTA.

Comment
9 pages, 6 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Topology-Aware Parameter-Efficient Adaptation for Cross-Dataset Retinal Vessel Segmentation

cs.CV ·2026-08-10 ·Yongsong Huang, Tomo Miyazaki, Kai Xu, Xiaofeng Liu, Yaohou Fan +1 more
similarity 0.65
Abstract · This manuscript is currently under peer review. Copyright may subsequently be transferred to the publisher, after which the availability of …

Retinal vessel segmentation in multi-domain deployment requires a source model to adapt to domains that differ in imaging conditions and annotation conventions. Conventional parameter-efficient fine-tuning reduces target-specific storage, but its highly restricted adaptation subspace can be insufficient for reconstructing thin, connected vascular structures. We therefore ask how target-specific capacity should be allocated so that topology-aware supervision remains effective under a strict per-domain parameter budget. Based on this principle, we propose TAPDecoderFT, a topology-responsive, role-structured adaptation framework. Specifically, TAPDecoderFT shares a fixed source parameter state across deployment domains, uses low-rank residuals for target-specific private/fusion feature mixing, and retains a trainable dense-reconstruction path comprising the decoder, output head, and refinement module. To promote structurally faithful predictions, the compact target state is jointly optimized with a region-overlap and topology-aware objective that encourages centerline continuity and thin-branch recovery. It improves both DSC and clDice over GenericLoRA-r4 and narrow TAP-r4 in all six directions and is comparable to full fine-tuning.

0.04

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.62
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23

Branch-Centric Tokenization and Test-Time Augmentation for Skeleton Generation

cs.CV ·2026-09-05 ·Zhengyuan Li, Chuanyu Pan, Yuanming Hu, Raymond A. Yeh
similarity 0.62
Abstract

Automatic skeleton generation involves predicting both joint positions and skeletal connectivity. However, existing approaches struggle to encode branch structures into token sequences and do not use test-time computation effectively. We study these choices within a unified autoregressive framework. First, we introduce branch-centric tokenization, a branch-aware representation that places structurally related elements next to each other and encodes connectivity directly in the sequence. Compared with standard BFS-style serialization, this representation yields more compact sequences. Second, we introduce view-augmented generation, a test-time augmentation procedure that applies axis-aligned rotations to the input mesh, maps all predictions back to a common frame, and selects the final skeleton based on mesh coverage and consistency among predictions from different views. Experiments show that our method achieves better skeleton prediction accuracy than state-of-the-art methods. In particular, our method reduces the CD-J2B error by 16.9% on the Articulation-XL2.0 dataset compared to the strongest directly comparable baseline, Auto-Connect. Qualitative results on in-the-wild meshes further demonstrate generalization across diverse inputs.

0.29

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.61
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

TMAL: Topology-preserving Multi-offset Affinity Learning for Curvilinear Structure Segmentation

cs.CV physics.med-ph ·2026-11-10 ·Suho Han, Soungsill Park, Kanghyun Ryu, Yoseob Han
code/datahot direction similarity 0.61
Abstract · 15 pages, 11 figures, submitted to WACV 2027

Curvilinear structures such as retinal vessels and surface cracks need both pixel-level accuracy and structural continuity. Pixel-wise supervision does not model the connections between pixels, and topology-based losses still produce ordinary masks. Connectivity-based methods predict these connections directly, but they use binary connectivity targets over a fixed local range. Such labels give the same value to thin segments and to thick regions, and they cannot describe connections at larger offsets. To address these limitations, we propose Topology-preserving Multi-offset Affinity Learning (TMAL). TMAL uses soft affinities that emphasize thin regions near the boundary, and it predicts directional affinities at several offsets to reach further. It then combines these affinities with weights that come from the decoder features, so local continuity and wider context are used together. An auxiliary segmentation branch adds region-level supervision and keeps the overlap accuracy high. On the retinal vessel dataset DRIVE and the crack inspection dataset DeepCrack, TMAL reaches the highest Dice, IoU, and clDice scores, and it greatly reduces the connected-component error $Δβ_0$. Code is available at https://github.com/suho-han/TMAL.

0.43

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation

cs.CV ·2026-10-01 ·Samuel Hart, Ahmad Yahya, Ahmed Karam Eldaly
theory similarity 0.60
Abstract · 12 pages

While state-of-the-art automated models for medical image segmentation achieve high mean performance, they frequently suffer from localized, catastrophic failures that preclude safe clinical deployment, particularly in neuro-oncology. Interactive segmentation frameworks mitigate this by incorporating human oversight, but traditionally impose prohibitive cognitive and temporal workloads by requiring clinicians to manually search for errors. In this project, we present an efficient, Hybrid Structural-Aleatoric Human-in-the-Loop framework for glioma segmentation that bridges the gap between automated baseline performance and surgical-grade precision, achieving sub-2.0 mm HD95 on curated benchmarks while providing safety-net routing for structural failures across real-world clinical data. By extracting voxel-wise Test-Time Augmentation (TTA) uncertainty and applying hierarchical topological filtering, our method proactively isolates high-risk structural anomalies. We comprehensively evaluated our approach on a challenging out-of-distribution clinical stress-test cohort (N = 362). Operating under a simulated Human Oracle, the framework improved the Whole Tumor (WT) Dice score from 0.891 to 0.914 and reduced the 95th percentile Hausdorff Distance (HD95) from 5.82 mm to 4.76 mm. Critically for surgical safety, the system rescued severe boundary failures in the Tumor Core, reducing mean HD95 from 17.96 mm to 14.83 mm (improving absolute TC Dice to 0.356). These spatial rescues were achieved while demanding a median interactive workload of just 11.3% of the target volume. Acknowledging this as a simulated upper bound lacking real-world cognitive friction, the framework nevertheless demonstrates a highly Pareto-efficient pathway for safely deploying clinical AI.

0.15

Tail Cues, Principal Corrections: Plug-and-Play Rectification for Open-Set Test-Time Adaptation

cs.LG cs.CV ·2026-10-27 ·Yingkai Yang, Chaoqi Chen, Hui Huang
top venuebenchmark similarity 0.60
Abstract · Accepted at NeurIPS 2026

Open-Set Test-Time Adaptation (OSTTA) operates on non-stationary target streams where covariate and semantic shifts coexist. Existing TTA methods often obtain adaptation signals by updating model parameters or maintaining mutable memories, which can be costly and vulnerable to unknown samples. We present TALOR, a lightweight, backward-free rectification module that uses the source linear head as a geometric anchor. The head-induced basis decomposes each normalized feature into high-gain principal coordinates and low-gain tail coordinates. TALOR estimates a soft-routed affine correction in the principal subspace, combining a regime-level principal bias with a tail-conditioned slope that captures sample-level tail-to-principal coupling. Using weighted ridge regression, it subtracts this drift estimate from the principal coordinates, reconstructs the feature and feeds it into the source head. On the ImageNet-C benchmark with six csOOD datasets, TALOR outperforms the next-best UniEnt by 2.2% H-score while running 2.5x faster and using only 12% of its GPU memory; as a post-correction plug-in, it further boosts COME to 68.4% H-score with only 2% additional memory overhead.

0.27

CAST: Calibrating Correspondences for Training-Free Biomedical In-Context Segmentation

cs.CV ·2026-11-17 ·Mingze Jiang, Jiashu Han, Haonan Chen, Zhiyi Li, Yilun Du +1 more
similarity 0.60
Abstract · 10 pages, 6 figures

Biomedical image segmentation must keep up with new anatomical structures, subjects, imaging modalities, and acquisition protocols, yet dense expert annotations are scarce and models trained on one cohort often struggle to transfer. In-context segmentation (ICS) offers a way out: a new structure is specified by a few annotated exemplars at inference time. However, reliable correspondence remains challenging in biomedical images, where adjacent structures often share similar appearances, and variations across subjects and imaging conditions further obscure their distinctions. We introduce CAST, a training-free framework built on a frozen DINOv3 backbone to calibrate fine-grained correspondences. Its stability test improves feature reliability at both global and patch-specific levels, while its coherence test assesses whether candidate correspondences are supported by consistent local structural context. Together, these tests enable more reliable correspondence across diverse anatomical structures and imaging conditions. Across eight biomedical benchmarks spanning 2D and 3D segmentation, cross-subject, and cross-modality transfer, CAST outperforms the strongest overall baseline by 12.34 percentage points in Dice and ranks first across all six volumetric settings. The versatility of CAST further opens up opportunities for challenging biomedical applications, including 2D-to-3D segmentation and atlas label transfer.

0.25