CS Paper Radar

TMAL: Topology-preserving Multi-offset Affinity Learning for Curvilinear Structure Segmentation

Suho Han, Soungsill Park, Kanghyun Ryu, Yoseob Han

cs.CV physics.med-ph ·submitted 2026-11-10 03:38 UTC · v1
code/datahot direction

Abstract

Curvilinear structures such as retinal vessels and surface cracks need both pixel-level accuracy and structural continuity. Pixel-wise supervision does not model the connections between pixels, and topology-based losses still produce ordinary masks. Connectivity-based methods predict these connections directly, but they use binary connectivity targets over a fixed local range. Such labels give the same value to thin segments and to thick regions, and they cannot describe connections at larger offsets. To address these limitations, we propose Topology-preserving Multi-offset Affinity Learning (TMAL). TMAL uses soft affinities that emphasize thin regions near the boundary, and it predicts directional affinities at several offsets to reach further. It then combines these affinities with weights that come from the decoder features, so local continuity and wider context are used together. An auxiliary segmentation branch adds region-level supervision and keeps the overlap accuracy high. On the retinal vessel dataset DRIVE and the crack inspection dataset DeepCrack, TMAL reaches the highest Dice, IoU, and clDice scores, and it greatly reduces the connected-component error $Δβ_0$. Code is available at https://github.com/suho-han/TMAL.

Comment
15 pages, 11 figures, submitted to WACV 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Topology-Aware Parameter-Efficient Adaptation for Cross-Dataset Retinal Vessel Segmentation

cs.CV ·2026-08-10 ·Yongsong Huang, Tomo Miyazaki, Kai Xu, Xiaofeng Liu, Yaohou Fan +1 more
similarity 0.65
Abstract · This manuscript is currently under peer review. Copyright may subsequently be transferred to the publisher, after which the availability of …

Retinal vessel segmentation in multi-domain deployment requires a source model to adapt to domains that differ in imaging conditions and annotation conventions. Conventional parameter-efficient fine-tuning reduces target-specific storage, but its highly restricted adaptation subspace can be insufficient for reconstructing thin, connected vascular structures. We therefore ask how target-specific capacity should be allocated so that topology-aware supervision remains effective under a strict per-domain parameter budget. Based on this principle, we propose TAPDecoderFT, a topology-responsive, role-structured adaptation framework. Specifically, TAPDecoderFT shares a fixed source parameter state across deployment domains, uses low-rank residuals for target-specific private/fusion feature mixing, and retains a trainable dense-reconstruction path comprising the decoder, output head, and refinement module. To promote structurally faithful predictions, the compact target state is jointly optimized with a region-overlap and topology-aware objective that encourages centerline continuity and thin-branch recovery. It improves both DSC and clDice over GenericLoRA-r4 and narrow TAP-r4 in all six directions and is comparable to full fine-tuning.

0.04

FPG-Seg: Annotation-free Retinal Vessel Topology Segmentation

cs.CV ·2026-10-15 ·James Willoughby, Irina Voiculescu
benchmark similarity 0.64
Abstract

State-of-the art approaches to retinal vessel segmentation typically require extensive annotations, a highly time-consuming process, reliant on clinical expertise. We present FPG-Seg, an annotation-free pipeline for retinal vessel segmentation combining classical vesselness filtering, Bayesian deep learning and topology-aware graph reconstruction to segment retinal vessel topology without manual labels. Tested across four widely used benchmark datasets for retinal vessel segmentation, FPG-Seg attains a clDice of $0.74{-}0.78$, representing $86{-}98\%$ of the performance of an equivalent fully-supervised baseline, despite using no manual annotations for training or hyperparameter tuning. As part of this work, we also provide, to our knowledge, the first performance benchmark of an annotation-free vessel segmentation method on FIVES.

0.18

MICRO: A Surgery-Phase Retinal Image Rigid Registration Benchmark and One-Step Frequency-Structure Similarity Registration Learning

cs.CV ·2026-11-09 ·Mingdao Gong, Yan Hu, Mingzhen Yuan, Jialu Zhang, Junming Feng +7 more
benchmarkdatasetposition similarity 0.64
Abstract

Precise multimodal retinal image rigid registration (MRIRG) is essential for aligning cross-modal vessel structures, offering critical guidance for ophthalmic surgery. Despite its significance, the advancement of MRIRG is hindered by the lack of publicly available multimodal retinal image rigid registration datasets spanning various ophthalmic surgery phases (e.g., preoperative, intraoperative, and postoperative). To address this issue, we introduce the MICRO dataset, a large-scale MRIRG benchmark, comprising 1,365 cross-modal retinal image pairs with standardized annotations across all ophthalmic surgery phases. Moreover, existing deep registration methods achieve competitive MRIRG results via a two-step segmentation-then-detection framework, but segmentation quality heavily constrains their performance. We argue that this dependency stems from an implicit need for keypoint topology constraints, which have not been exploited for MRIRG through a one-step registration framework. Inspired by the above analysis, we propose a novel One-step Frequency-Structure Similarity Registration (OFS2Reg) learning framework for MRIRG that leverages the potential of cross-modal vessel structure similarities to construct keypoint topology constraints under a shared detection network. To be specific, OFS2Reg applies a well-designed frequency-guided structure preservation descriptor to construct coarse keypoint topology constraints in descriptors by highlighting significant vessel structures. Additionally, we develop a new cross-modal vessel structure similarity learning method that refines cross-modal keypoint topology constraints to precisely align pixel-level cross-modal vessel structures by leveraging cross-modal vessel structure similarity priors.

0.17

Anchored Slice Propagation with Boundary Transport for 3D CT Segmentation from Three Orthogonal Annotated Slices

cs.CV ·2026-11-03 ·Tushar Kataria, Md Rakibul Haque, Shireen Y. Elhabian
similarity 0.63
Abstract

Sli2Vol propagates a binary mask through affinities between adjacent slices, but an error can persist because each prediction becomes the input to the next step. Three orthogonal annotations reduce dependence on any one chain, yet they offer more than three starting masks: where a chain crosses another annotated plane, the correct label is already known. Those labels could correct drift during propagation and indicate how much to trust each chain at fusion. Between annotated planes, the information carried by the chain may matter as well. A binary mask records foreground membership but discards distance to the boundary, a cue that could help follow gradual shape changes between slices.We address these two sources of error with a fixed pretrained affinity backbone. We anchor each chain by correcting its prediction where it crosses another annotated plane, then use its agreement with those labels to weight fusion. We compare this anchored mask with two ways of transporting boundary geometry: a truncated signed-distance field (SDF) propagated by dense affinity averaging, and a contour whose vertices follow motion cues from the same affinity. The contour tracker starts from a hand-crafted rule and learns a motion correction from supervoxel pseudo-objects in 506 CT volumes, without manual organ labels. On 2,091 held-out structure instances from approximately 403 CT scans spanning 17 abdominal structures, anchoring raises mean Dice from 0.737 with orthogonal mask propagation to 0.769 and improves every structure. Beyond the anchored mask, learned contour tracking improves Dice by 5.7\% for the esophagus and 5.9\% for the postcava, while SDF transport improves right-adrenal Dice by 2.8\%. The anchored methods have similar mean Dice (0.769--0.772); contour tracking performs worse on the kidneys, stomach, and hepatic vessel tree.

0.20

VTRL-Med: Progressive Visual Refinement with Topology-Guided Regularization for Medical Image Clustering

cs.CV ·2026-10-23 ·Guangyu Meng, Pengfei Gu, Peixian Liang, John P. Lalor, Erin Wolf Chambers +1 more
similarity 0.63
Abstract

Deep clustering offers a promising approach for analyzing large unlabeled medical image datasets, yet prevailing methods still face two limitations: they may neglect class-agnostic structural priors that capture object boundaries and regions, and they do not explicitly encode topological patterns (e.g., connectivity and holes). These sources of information play distinct and complementary roles: visual-structural features provide the primary discriminative representation for clustering, while topological features provide additional global geometric cues for residual visual ambiguities. We introduce VTRL-Med, a progressive visual-structural learning framework with topology-guided regularization for medical image clustering. VTRL-Med first adapts the Segment Anything Model (SAM) to extract image features that retain structural cues inherited from mask-supervised pretraining. It then generates reliable pseudo-labels through a two-step filtering process that combines prototype-based selection with k-nearest neighbor consistency validation. Finally, it progressively refines the visual branch while an auxiliary topology branch, constructed from persistent homology (PH) descriptors, provides additional geometric regularization during training. Across 13 medical image benchmarks, VTRL-Med achieves state-of-the-art clustering performance, improving average accuracy by 4.48% over existing methods. On three representative datasets, topology-guided regularization further improves accuracy by 1.3--4.3% over visual refinement alone.

0.43

A Real-World CAD Segmentation Benchmark: Comparing Rule-Based and Learning-Based Approaches through Hole Detection

cs.CV ·2026-10-09 ·Kai Schütte, Edgar Heinert, Matthias Rottmann
benchmark similarity 0.63
Abstract

CAD segmentation datasets are predominantly synthetic or automatically labelled, leaving it unclear how well existing methods transfer to real-world engineering tasks. Fastener-relevant hole detection represents one such task, requiring human annotation and exhibiting greater geometric complexity than commonly used benchmarks. We address this gap through three main contributions. First, we develop two task-specific rule-based methods, one graph-wire-search and one multi-view based, and complement them with a human-annotated benchmark dataset derived from engineering CAD data that also enables training of UV-Net and AAGNet, representative learning-based approaches for B-Rep segmentation. Second, we conduct an extensive experimental study including parameter optimisation, evaluation on our benchmark dataset, cross-domain generalisation on a synthetic dataset, and an assessment of the feasibility of the approaches at varying dataset sizes and IoU thresholds. Third, we provide evidence-based insights into the strengths and limitations of different approaches: rule-based methods generalise well without training data, with the graph-wire-search method favouring recall and the multi-view method favouring precision, whereas learning-based methods achieve strong performance with sufficient annotations but exhibit reduced robustness under domain shift. These findings highlight trade-offs between data requirements, and robustness, and provide guidance not only for hole detection, but more broadly for real-world CAD segmentation tasks.

0.14

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.62
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23

U-PEN Mamba: Progressive Expansion with Selective State-Space Modeling for Efficient Retinal Vessel Segmentation

cs.CV ·2026-09-21 ·Abel A. Reyes-Angulo, Sidike Paheding, Vijayan K. Asari, Mohammad Alam, Jeevan Devagiri
publishedcode/data similarity 0.62
Abstract

Accurate retinal vessel segmentation is important for computer-aided ophthalmic analysis, yet thin vessels, low contrast, and severe foreground-background imbalance remain challenging for encoder-decoder networks. This paper presents U-PEN Mamba, a U-shaped retinal vessel segmentation architecture that couples progressive nonlinear feature expansion with selective state-space modeling. The proposed network enriches local vessel responses with progressive expansion, models long-range spatial dependencies through a Mamba Global Context (MGC) block with linear sequence complexity, and uses attention-based decoder fusion to recover fine vascular boundaries. We evaluate U-PEN Mamba on CHASE DB1 and DRIVE using a consistent patch-based preprocessing pipeline and compare it with convolutional, attention-based, transformer-based, and Mamba-based segmentation baselines. U-PEN Mamba obtains the best mean intersection over union among the compared methods, achieving 0.8394 on CHASE DB1 and 0.8221 on DRIVE, with Dice scores of 0.8187 and 0.8078, respectively, using 21.6M trainable parameters. Ablation studies show that the MGC block contributes the largest gain over the U-Net baseline, while projection dimension and state size provide practical accuracy-efficiency control. These results indicate that selective state-space modeling is a promising global-context mechanism for parameter-efficient retinal vessel segmentation. Code is available at: https://github.com/areyesan/UPEN_Mamba.

0.45