CS Paper Radar

MICRO: A Surgery-Phase Retinal Image Rigid Registration Benchmark and One-Step Frequency-Structure Similarity Registration Learning

Mingdao Gong, Yan Hu, Mingzhen Yuan, Jialu Zhang, Junming Feng, Yiming Jiang, Jing Ma, Jinghua Liu, Huazhu Fu, Hai Lu, Xiaoqing Zhang, Jiang Liu

cs.CV ·submitted 2026-11-09 12:45 UTC · v1
benchmarkdatasetposition

Abstract

Precise multimodal retinal image rigid registration (MRIRG) is essential for aligning cross-modal vessel structures, offering critical guidance for ophthalmic surgery. Despite its significance, the advancement of MRIRG is hindered by the lack of publicly available multimodal retinal image rigid registration datasets spanning various ophthalmic surgery phases (e.g., preoperative, intraoperative, and postoperative). To address this issue, we introduce the MICRO dataset, a large-scale MRIRG benchmark, comprising 1,365 cross-modal retinal image pairs with standardized annotations across all ophthalmic surgery phases. Moreover, existing deep registration methods achieve competitive MRIRG results via a two-step segmentation-then-detection framework, but segmentation quality heavily constrains their performance. We argue that this dependency stems from an implicit need for keypoint topology constraints, which have not been exploited for MRIRG through a one-step registration framework. Inspired by the above analysis, we propose a novel One-step Frequency-Structure Similarity Registration (OFS2Reg) learning framework for MRIRG that leverages the potential of cross-modal vessel structure similarities to construct keypoint topology constraints under a shared detection network. To be specific, OFS2Reg applies a well-designed frequency-guided structure preservation descriptor to construct coarse keypoint topology constraints in descriptors by highlighting significant vessel structures. Additionally, we develop a new cross-modal vessel structure similarity learning method that refines cross-modal keypoint topology constraints to precisely align pixel-level cross-modal vessel structures by leveraging cross-modal vessel structure similarity priors.

Closest papers

Nearest neighbours by meaning across the whole index.

Modality-Invariant Coarse-to-Fine Retinal Image Registration

eess.IV cs.CV ·2026-08-14 ·Bo Wen, Nehal Nailesh Mehta, Melanie Tran, Dirk-Uwe Bartsch, William Freeman +1 more
published similarity 0.78
Abstract · This paper is a submission to IEEE Transactions on Image Processing (TIP-40498-2026)

Retinal image registration is essential for ophthalmic diagnosis, longitudinal disease monitoring, and multimodal retinal image analysis. Existing retinal registration methods are typically modality-dependent: they are designed or optimized either for a single imaging modality in mono-modal registration or for a fixed pair of modalities in cross-modal registration. This limits their flexibility and applicability in practical scenarios involving diverse retinal imaging modalities and different combinations of them. In this work, we propose a generalizable two-stage, modality-invariant framework for retinal image registration. First, we introduce a sparse feature-matching model driven by a universal retinal vessel segmentation to achieve robust coarse global alignment across modalities. Second, we develop a modality-invariant optical flow estimation network, termed MI-RAFT, to refine the alignment through dense local registration. Extensive experiments demonstrate that the proposed method can handle diverse combinations of commonly used retinal imaging modalities, exhibiting strong modality invariance while outperforming state-of-the-art modality-dependent registration methods.

0.17

Really Need Recursion? Revisiting One-pass Registration with Multi-level Multi-space Contextual Guidance

eess.IV cs.AI ·2026-10-15 ·Yue Lin, Shenghai Wu, Mingyuan Meng
top venue similarity 0.68
Abstract · Accepted at MICCAI 2026

Deformable image registration is a fundamental challenge in medical image analysis. Recent deep learning-based methods typically adopt either one-pass architectures that complete registration in a single network iteration, or recursive architectures that refine registration through multiple passes. While recursive methods often improve accuracy, they incur substantial computational overhead and slower inference speed. In this paper, we challenge the necessity of recursion for high-performance deformable registration and propose M2CG, a one-pass registration network with Multi-level Multi-space Contextual Guidance. It performs multi-step progressive pyramid registration within a single iteration, guided at each step by contextual cues from three levels (previous, current, and subsequent steps) and four spaces (image space, image feature space, segmentation space, and segmentation feature space). Our M2CG supports both unsupervised (without any labels) and semi-supervised (with segmentation labels for partial training data) registration, and has achieved state-of-the-art performance across two well-benchmarked inter-/intra-patient medical registration tasks with eight public datasets. Our findings suggest that the current reliance on recursion may stem from the absence of sufficient contextual cues that comprehensively characterize the remaining distance to the target alignment.

0.31

FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

cs.CV physics.med-ph ·2026-10-25 ·Mojtaba Safari, Mingzhe Hu, Shansong Wang, Suyang Xi, Joshua Lorenz +4 more
code/data similarity 0.67
Abstract

Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Independent Neighborhood Descriptor with Self-Similarity Context (MIND-SSC) and features from pretrained vision encoders provide distinct representations for correspondence estimation, but how they should be combined remains unclear. We investigate whether tighter integration improves registration over a sequential, scale-separated design. Approach. We introduce FlexiMIND, a training-free and label-free two-stage framework in which frozen FlexiCT-2D encoder features establish contextual correspondence and MIND-SSC refines the deformation within ConvexAdam. Five alternative feature-coupling strategies were evaluated under a protocol across CT-CT (DIR-Lab 4DCT 4DCT, 10 cases), MR-MR (ACDC, 50 patients), and MR-CT (Learn2Reg Abdomen MR-CT, 8 pairs) registration. Performance was assessed using target registration error (TRE), Dice similarity coefficient (Dice), SDlogJ, and local folding. Main results. FlexiMIND achieved a TRE of 1.27 mm on DIR-Lab 4DCT, a DSC of 0.807 on ACDC, and an organ-averaged DSC of 0.825 on Abdomen MR-CT. Across 15 coupling-strategy dataset comparisons, only four outperformed the reference method, with a maximum absolute improvement of 0.0043 in Dice, whereas degradation reached 20.6 % in TRE and 37.9 % in Dice. Changes in registration accuracy were closely associated with changes in deformation-field regularity, and strategies that better preserved regularity generally remained closest to the reference performance. Landmark-level analysis showed that the pretrained encoder stage primarily reduced large correspondence errors rather than uniformly improving local precision. Code is available upon acceptance at https://github.com/mosaf/FlexiMIND.

0.24

LUMINR: Intensity-conditioned Meta-learned INRs for Accelerated Medical Image Registration

eess.IV cs.CV ·2026-10-16 ·Damian Rynczak, Marek Wodzinski
hot direction similarity 0.66
Abstract · 13 pages, 7 figures, 3 tables

Implicit neural representations (INRs) have been applied to deformable image registration, where a lightweight network maps a spatial coordinate to a deformation vector. Because an INR encodes one specific signal in its parameters, a fresh network must be optimized for every image pair at test time, which is slow. Existing methods reduce this cost by meta-learning an initialization across a population of image pairs, and condition the weights of the INR globally, so the same conditioning applies at every coordinate while the deformation field it initializes varies across the domain. We propose LUMINR, a meta-learning framework that accelerates this per-pair fitting and in which the conditioning is local instead. LUMINR uses an INR that maps a coordinate, together with local intensity and gradient features, to a deformation vector, so the conditioning varies over the domain at the resolution of the field being modelled. Its objective is to find an initialization of the INR parameters from which the network can be fine-tuned to register any unseen pair in only a few optimization iterations. We evaluate LUMINR on 3D deformable registration of brain MRI from the OASIS dataset, where local conditioning and the meta-learned initialization prove complementary: early in fitting they reach a markedly higher accuracy than either does alone. Fine-tuned from that initialization, LUMINR matches the accuracy of the same conditioned INR fit from scratch in roughly a tenth of the gradient steps and a tenth of the wall-clock time, while the deformation fields stay smooth with negligible folding.

0.50

Benchmarking Intra-Patient 3D Deformable Multimodal Image Registration

cs.CV cs.AI ·2026-09-14 ·Matteo Barbieri, Giammarco La Barbera, Juan Pablo De La Plata, Sabine Sarnacki, Isabelle Bloch +1 more
benchmark similarity 0.65
Abstract · Preprint Under Review

Multimodal image registration is a key component of many clinical workflows, yet it remains challenging because corresponding anatomical structures often exhibit substantially different image intensities across modalities. In this work, we present a comprehensive benchmark of intra-patient 3D multimodal deformable registration methods across three datasets covering different anatomical regions and difficulty levels, including both synthetic deformation recovery and real clinical scenarios. We evaluate classical optimization-based approaches and modern learning-based methods, including recent deep learning and foundation models, using complementary metrics: Average Dice similarity coefficient (DSC), average 95th-percentile Hausdorff distance (HD95), and a modality-independent structural similarity measure based on the MIND self-similarity context (MIND-SSC). Results show high variability across datasets, with learning-based methods demonstrating superior performance on large synthetic benchmarks, while only limited improvements are observed in real pelvic registration. A key finding of this study is the consistent disagreement between geometric metrics (DSC, HD95) and image-based similarity metrics (MIND-SSC), highlighting that improved overlap does not necessarily imply better global multimodal correspondence. Furthermore, anatomy-guided approaches achieve the highest overlap scores but exhibit degraded performance outside of segmented regions, revealing a trade-off between label-driven alignment and global structural coherence. Overall, our results indicate that no current method achieves robust performance across anatomies and modalities. We demonstrate that intra-patient 3D multimodal registration requires multi-criteria evaluation, including deformation-based metrics, and remains an open problem.

0.16

Unsupervised Multi-modal Medical Image Registration via Invertible Translation

cs.CV ·2026-11-17 ·Mengjie Guo, Jinming Duan
code/data similarity 0.65
Abstract

In medical imaging, the alignment of multi-modal images plays a critical role in providing comprehensive information for image-guided therapies. Despite its importance, multi-modal image registration poses significant challenges due to the complex and often unknown spatial relationships between different image modalities. To address this, we introduce a novel unsupervised translation-based multi-modal registration method, termed Invertible Neural Network-based Registration (INNReg). INNReg consists of an image-to-image translation network that converts multi-modal images into mono-modal counterparts and a registration network that uses the translated mono-modal images to align the multi-modal images. Specifically, to ensure the preservation of geometric consistency after image translation, we introduce an Invertible Neural Network (INN) that leverages a dynamic depthwise convolution-based local attention mechanism. Additionally, we design a novel barrier loss function based on Normalized Mutual Information to impose constraints on the registration network, which enhances the registration accuracy. The superior performance of INNReg is demonstrated through experiments on two public multi-modal medical image datasets, including MRI T1/T2 and MRI/CT pairs. The code is available at https://github.com/MeggieGuo/INNReg

0.42

TMAL: Topology-preserving Multi-offset Affinity Learning for Curvilinear Structure Segmentation

cs.CV physics.med-ph ·2026-11-10 ·Suho Han, Soungsill Park, Kanghyun Ryu, Yoseob Han
code/datahot direction similarity 0.64
Abstract · 15 pages, 11 figures, submitted to WACV 2027

Curvilinear structures such as retinal vessels and surface cracks need both pixel-level accuracy and structural continuity. Pixel-wise supervision does not model the connections between pixels, and topology-based losses still produce ordinary masks. Connectivity-based methods predict these connections directly, but they use binary connectivity targets over a fixed local range. Such labels give the same value to thin segments and to thick regions, and they cannot describe connections at larger offsets. To address these limitations, we propose Topology-preserving Multi-offset Affinity Learning (TMAL). TMAL uses soft affinities that emphasize thin regions near the boundary, and it predicts directional affinities at several offsets to reach further. It then combines these affinities with weights that come from the decoder features, so local continuity and wider context are used together. An auxiliary segmentation branch adds region-level supervision and keeps the overlap accuracy high. On the retinal vessel dataset DRIVE and the crack inspection dataset DeepCrack, TMAL reaches the highest Dice, IoU, and clDice scores, and it greatly reduces the connected-component error $Δβ_0$. Code is available at https://github.com/suho-han/TMAL.

0.43

Where to Predict in Retinal OCT? Anatomy-Guided Target Selection for I-JEPA

cs.CV ·2026-11-12 ·Yunchu Feng, Wai Tak Lau, Kaveri A. Thakoor
published similarity 0.64
Abstract · 18 pages. Accepted as a poster at the GenAI for Health Workshop at NeurIPS 2026 (non-archival)

Self-supervised learning aims to learn meaningful representations from unlabeled data, potentially allowing models to capture subtle anatomical variations across patients and reduce the amount of labeled data needed. Image-based Joint-Embedding Predictive Architecture (I-JEPA) learns by predicting target-region representations from visible context rather than reconstructing pixels. However, its uniform target placement does not account for the anatomical structure of retinal OCT, where retinal tissue occupies only part of each B-scan. We investigate anatomy-guided target selection using image intensity and predicted retinal segmentation while retaining the I-JEPA architecture and latent prediction objective. We compare anatomy-guided rectangular targets, anatomy-shaped targets and coverage-constrained placement with uniform masking, and evaluate the learned representations using linear probing for glaucoma classification on FairVision. We found that rectangular targets guided by image intensity achieved the highest linear-probe AUC in our comparisons. We show that anatomically meaningful target selection is promising for retinal OCT representation learning, while greater anatomical specificity did not consistently improve performance.

0.35