CS Paper Radar

RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM

Jaafar M. Al-Ghabban, Mohammad Reza Mohammadi

cs.CV cs.LG ·submitted 2026-11-09 05:23 UTC · v1

Abstract

Retinal disease monitoring with optical coherence tomography angiography (OCTA) relies on segmentation of vessels and the foveal avascular zone (FAZ). Promptable models such as SEEM (Segment Everything Everywhere All at Once) allow click-based refinement, but without adaptation SEEM segments thin vessels poorly and needs many clicks. Fully fine-tuning its 342 million parameters on a few hundred images is costly and risks overfitting, and parameter-efficient methods such as low-rank adaptation (LoRA) usually adapt only the encoder. Yet SEEM reads every candidate mask from one feature map at quarter resolution, too coarse for vessels one to three pixels wide. This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution. Each candidate accesses them through its own vector and a zero-initialised projection, so the model starts exactly as SEEM. The encoder branch, a standard rank-1 LoRA, supplies the information needed to tell arteries from veins. RBA adds 0.47 million trainable parameters. Under simulated error-driven clicks, with the ground truth used only to place them, RBA outperforms LoRA, Conv-LoRA andAdaptFormer on OCTA-500 3mmlarge vessels. Averaged over three seeds, it reaches an intersection over union (IoU) of 85.16% and a Dice score of 91.93%, 2.90 and 1.72 percentage points above Conv-LoRA. On the 6 mm subset, one run gives margins of 4.35 and 2.76 points. The gain extends to arteries, veins and ROSE-O but not to the FAZ. In SEEM, adaptation capacity pays more at the mask read-out than in the encoder.

Closest papers

Nearest neighbours by meaning across the whole index.

An Ultra-Widefield Swept-Source OCTA Dataset and a Polar-Gated Mamba Network for Retinal Vessel Segmentation

cs.CV ·2026-09-11 ·Yang Liu, Yibing Shen, Keming Zhao, Cenk Jiang, Zhenghang Qian +10 more
code/data similarity 0.69
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics. Under review

Ultra-widefield (UWF) swept-source optical coherence tomography angiography (SS-OCTA) enables large-area retinal vascular imaging, yet vessel segmentation at this scale lacks dedicated public benchmarks and comprehensive evaluation for quantitative vascular analysis. We introduce WOIVES, to our knowledge the first publicly available UWF SS-OCTA vessel-segmentation dataset, comprising 206 eyes from 152 participants with a 24x20mm^2 field of view. WOIVES spans emmetropia to high myopia and provides soft probability vessel annotations. We further propose PG-Mamba, a visual state space model that enhances conventional directional scans with two complementary polar-coordinate scan orders. An auxiliary Dynamic FOV Gating module performs spatial modulation at the bottleneck. PG-Mamba outperformed seven competitive approaches on broad segmentation metrics under cross-validation. It achieved the lowest median absolute errors for vessel density, fractal dimension, and vessel length density. WOIVES is publicly available on Zenodo (DOI: 10.5281/zenodo.21904672), and the PG-Mamba code is available at https://github.com/syb1234567/PG-Mamba.

0.36

CGDD-Net: Context-Guided Dynamic Detail Modeling for Retinal Vessel Segmentation

cs.CV ·2026-10-04 ·Xincheng Li, Xiaoqi Sheng, Xinyu Zhang
code/data similarity 0.66
Abstract

Accurate retinal vessel segmentation requires features that capture vascular geometry while preserving information for fine-scale reconstruction. We propose CGDD-Net, a context-guided dynamic detail modeling network that connects adaptive feature extraction to a shared decoder pathway. Context-Guided Scale-Adaptive Deformable Encoding (CSDE) combines fixed-grid convolution with deformable local attention to capture vascular patterns at multiple spatial extents. Spatially Adaptive Multi-Kernel Gating (SAMG) selects receptive-field responses at each location. Dynamic Cross-Scale Detail Fusion (DCDF) aligns the gated intermediate features and compresses them into an eight-channel representation, which is reused at three decoder resolutions together with selected encoder skips. This design consolidates intermediate information before decoding instead of transferring each middle-stage feature through a separate direct skip. On DRIVE, CHASE\_DB1, STARE, and HRF, CGDD-Net achieves AUC values of 0.9824, 0.9938, 0.9895, and 0.9874, with F1 scores of 0.8323, 0.8102, 0.8510, and 0.8157, respectively. The complete model contains 1.96 million trainable parameters. In cumulative ablations, the full model improves F1 over the internal baseline by 2.48, 0.61, and 3.49 percentage points on DRIVE, CHASE\_DB1, and STARE. Twelve directed cross-dataset experiments further characterize transfer without target-domain adaptation. The results support shared intermediate detail delivery as an effective, parameter-compact architecture for retinal vessel segmentation. Code is available at \url{https://github.com/lixincheng-xcl/CGDD-Net}.

0.18

Evidence-Guided Selection of Retinal Vessel Segmentation Pipelines: A Cross-Dataset Benchmark of Performance, Structure, Failure Modes, and Reproducibility

cs.CV ·2026-10-22 ·Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo +2 more
benchmark similarity 0.65
Abstract

Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structural fidelity, cross-dataset robustness, and application-specific error costs. We evaluated five executable binary vessel-segmentation pipelines (FSG-Net, SA-UNetv2, DCP-1024, GAVE, and FR-UNet) on 244 images from six public datasets using pixel-level agreement, cross-dataset stability, thin-vessel retention, structural metrics, error composition, and available computational evidence. Results were aggregated with equal weighting across datasets. No pipeline was optimal in every setting. FSG-Net achieved the highest equal-dataset mean Macro-F1 (0.77), IoU (0.63), clDice (0.83), and Skeleton F1 (0.78), whereas SA-UNetv2 achieved the highest mean sensitivity (0.85) and Thin-Vessel Sensitivity (0.63). Differences across datasets were often larger than those among the leading pipelines, and errors shared by all five methods were concentrated near annotated vessel boundaries and faint peripheral vessels. In an ancillary analysis on 45 HRF images, segmentation masks were converted into 11 ring-wise vascular features for leave-one-out classification. Controlled perturbations showed that local mask errors can be amplified in downstream features, while targeted stabilization reduced sensitivity for five features. The results support task-conditioned, benchmark-relative pipeline selection rather than a single universal ranking and highlight the need to validate the selected pipeline on the intended target domain.

0.09

A Stage-Wise Explainable Pipeline for Arteriolar-to-Venular Ratio Estimation and Retinopathy Screening

cs.CV cs.AI ·2026-11-10 ·Sharan Sharmeela Karuppannan, Yoga Sri Varshan, Subin Sahayam, Umarani Jayaraman
published similarity 0.65
Abstract · Accepted for presentation at the 23rd IEEE India Council International Conference (INDICON 2026)

The arteriolar-to-venular diameter ratio (AVR) is a clinically motivated marker of retinal vascular health. We present a five-stage pipeline for AVR estimation and exploratory retinopathy screening from fundus images, with inspectable intermediate outputs at each stage. The pipeline combines vessel and artery-vein masks, optic-disc localization, vessel-calibre estimation using a minimal-chord boundary walk, and AVR computation from dominant arterial and venular branches. An explicit threshold-based rule produces the screening decision, enabling errors to be traced to individual processing stages. On an exploratory cohort of 30 HRF images, we report 96.7% accuracy, an F1-score of 0.968 and ROC-AUC of 0.978. Ablation studies and an exploratory comparison with VascX examine the effects of vessel pairing, calibre measurement and aggregation. Interpretation is limited by the small cohort, proxy disease labels and absence of independent reference calibre measurements. The pipeline provides a transparent framework for investigating retinal vascular biomarkers, with further validation needed on larger, clinically graded cohorts.

0.32

Interpretable Fundus Image Classification via Ring-Based Retinal Vasculature Features

cs.CV stat.ML ·2026-08-25 ·Xiaoyan Li, Shixin Xu, Arvind Gupta, Huaxiong Huang
similarity 0.64
Abstract

Retinal fundus photography is widely used for screening and monitoring ocular diseases, but many modern classification pipelines rely on deep latent representations and provide limited interpretability. This study develops an interpretable fundus image classification framework based on a ring-structured representation of the retinal vasculature centered on the optic disc. The method quantifies vessel geometry, color appearance, oxygenation-related vascular appearance, and vessel--background entropy within concentric retinal regions. These physiologically motivated descriptors are derived from vessel masks, image intensities, and optical-density measurements and aggregated across rings to capture spatial variation in vascular properties. Using only quantitative vascular descriptors, the proposed method achieved strong classification performance across three public fundus datasets. On HRF, it achieved 91.1\% accuracy using automatically generated vessel masks, matching RETFound, a vision transformer pretrained on large-scale retinal fundus image data, under the same evaluation setting. Additional analyses suggest that pretrained image models are sensitive to acquisition-related spatial cues, including fundus scale and retinal position within the field of view, as well as broader non-vessel image characteristics. This framework may support interpretable disease classification, quantitative retinal phenotyping, and retinal biomarker discovery without requiring large task-specific training datasets.

0.44

Evaluating SAM-based and Convolutional Architectures in Thin Retinal Vessel Segmentation: Model Capacity, Computational Cost and Foundation Pre-training

cs.CV ·2026-10-30 ·Carlos Eduardo Fontaneli, Cesar Henrique Comin
similarity 0.63
Abstract

In retinal vessel segmentation, plain Vision Transformers (ViTs) are commonly expected to perform worse than convolutional neural networks (CNNs) on thin vessels, for reasons such as their coarse patch tokenization, their weak locality bias and their need for large training sets. Although this expectation is widely shared in the literature, how plain ViTs actually compare with CNNs on thin vessels has not been systematically quantified. We address this question by comparing a model with a plain ViT encoder (MedSAM), a hybrid Transformer (LiteMedSAM) and three CNNs of different sizes on three retinal datasets (DRIVE, HRF, FIVES) and, as a second-domain check, a microscopy dataset (VessMap). We measured the centerline recall and precision of thin vessels and compared the models while also considering their computational cost and how many epochs they needed to train. We found that the pre-trained MedSAM had a centerline recall of thin vessels that was not significantly different from that of the best CNN on all four datasets (-0.6 to +2.5 percentage points). A compact plain ViT obtained through architecture search but trained from scratch did not retain this performance. For pre-trained plain ViTs, our results do not support the expectation that they miss thin vessels, although similar thin-vessel performance can be obtained with much smaller models.

0.23

HierarchiRetina: A Diabetic Retinopathy Screening and Grading Cascade with Heterogeneous Mixture-of-Experts Lesion Segmentation

cs.CV ·2026-10-13 ·Md Asif Uddin, Niloy Farhan, Rafeed Rahman, Md. Golam Rabiul Alam
code/datahot direction similarity 0.63
Abstract · 8 pages, 8 figures, 8 tables. Submitted to the IEEE Journal of Biomedical and Health Informatics. Code, trained weights and per-image predic…

Clinical screening for diabetic retinopathy proceeds in stages, yet most automated systems grade fundus images with a single black-box network. Three gaps remain: (i) lesions differ widely in size and contrast, but segmenters typically apply the same blocks to all; (ii) ungradable images are usually excluded or treated as an extra class, and lesion-aware graders seldom test whether lesions drive the grade; (iii) staged systems often report each stage only on the images reaching it, leaving propagated errors unmeasured. HierarchiRetina, a screening, segmentation and grading cascade with inspectable stage outputs, addresses each gap. First, HSMoE-AUNet is a U-Net whose skip, bottleneck and decoder blocks are sparse mixtures of heterogeneous experts, with lesion-matched types, counts and losses; SwinHRUNetPP, a dual-encoder vessel segmenter, uses a field-of-view-restricted loss. Second, LG-DRG separates gradability from ordinal severity and lets lesion masks query the image through gated cross-attention. Third, an end-to-end evaluation counts screening misses as errors and traces each error to its stage. Pooled Dice ranged from 0.184 (microaneurysms) to 0.579 (exudates); vessel Dice was 0.731. On 58,689 held-out images from six datasets, end-to-end quadratic weighted kappa was 0.804, with referral sensitivity 0.832 at specificity 0.947, and the screening gate caused 66% of errors. In ablations, the grade ignored the masks, even with the cross-attention gate started open. On all 4,105 official DDR test images, six-class accuracy was 85.6%, above the best published six-class result we found (83.8%). Staged screening systems should be evaluated end-to-end, with stage attribution and mask ablation, before clinical deployment.

0.45

U-PEN Mamba: Progressive Expansion with Selective State-Space Modeling for Efficient Retinal Vessel Segmentation

cs.CV ·2026-09-21 ·Abel A. Reyes-Angulo, Sidike Paheding, Vijayan K. Asari, Mohammad Alam, Jeevan Devagiri
publishedcode/data similarity 0.62
Abstract

Accurate retinal vessel segmentation is important for computer-aided ophthalmic analysis, yet thin vessels, low contrast, and severe foreground-background imbalance remain challenging for encoder-decoder networks. This paper presents U-PEN Mamba, a U-shaped retinal vessel segmentation architecture that couples progressive nonlinear feature expansion with selective state-space modeling. The proposed network enriches local vessel responses with progressive expansion, models long-range spatial dependencies through a Mamba Global Context (MGC) block with linear sequence complexity, and uses attention-based decoder fusion to recover fine vascular boundaries. We evaluate U-PEN Mamba on CHASE DB1 and DRIVE using a consistent patch-based preprocessing pipeline and compare it with convolutional, attention-based, transformer-based, and Mamba-based segmentation baselines. U-PEN Mamba obtains the best mean intersection over union among the compared methods, achieving 0.8394 on CHASE DB1 and 0.8221 on DRIVE, with Dice scores of 0.8187 and 0.8078, respectively, using 21.6M trainable parameters. Ablation studies show that the MGC block contributes the largest gain over the U-Net baseline, while projection dimension and state size provide practical accuracy-efficiency control. These results indicate that selective state-space modeling is a promising global-context mechanism for parameter-efficient retinal vessel segmentation. Code is available at: https://github.com/areyesan/UPEN_Mamba.

0.45