CS Paper Radar

A Stage-Wise Explainable Pipeline for Arteriolar-to-Venular Ratio Estimation and Retinopathy Screening

Sharan Sharmeela Karuppannan, Yoga Sri Varshan, Subin Sahayam, Umarani Jayaraman

cs.CV cs.AI ·submitted 2026-11-10 12:51 UTC · v1
published

Abstract

The arteriolar-to-venular diameter ratio (AVR) is a clinically motivated marker of retinal vascular health. We present a five-stage pipeline for AVR estimation and exploratory retinopathy screening from fundus images, with inspectable intermediate outputs at each stage. The pipeline combines vessel and artery-vein masks, optic-disc localization, vessel-calibre estimation using a minimal-chord boundary walk, and AVR computation from dominant arterial and venular branches. An explicit threshold-based rule produces the screening decision, enabling errors to be traced to individual processing stages. On an exploratory cohort of 30 HRF images, we report 96.7% accuracy, an F1-score of 0.968 and ROC-AUC of 0.978. Ablation studies and an exploratory comparison with VascX examine the effects of vessel pairing, calibre measurement and aggregation. Interpretation is limited by the small cohort, proxy disease labels and absence of independent reference calibre measurements. The pipeline provides a transparent framework for investigating retinal vascular biomarkers, with further validation needed on larger, clinically graded cohorts.

Comment
Accepted for presentation at the 23rd IEEE India Council International Conference (INDICON 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Interpretable Fundus Image Classification via Ring-Based Retinal Vasculature Features

cs.CV stat.ML ·2026-08-25 ·Xiaoyan Li, Shixin Xu, Arvind Gupta, Huaxiong Huang
similarity 0.69
Abstract

Retinal fundus photography is widely used for screening and monitoring ocular diseases, but many modern classification pipelines rely on deep latent representations and provide limited interpretability. This study develops an interpretable fundus image classification framework based on a ring-structured representation of the retinal vasculature centered on the optic disc. The method quantifies vessel geometry, color appearance, oxygenation-related vascular appearance, and vessel--background entropy within concentric retinal regions. These physiologically motivated descriptors are derived from vessel masks, image intensities, and optical-density measurements and aggregated across rings to capture spatial variation in vascular properties. Using only quantitative vascular descriptors, the proposed method achieved strong classification performance across three public fundus datasets. On HRF, it achieved 91.1\% accuracy using automatically generated vessel masks, matching RETFound, a vision transformer pretrained on large-scale retinal fundus image data, under the same evaluation setting. Additional analyses suggest that pretrained image models are sensitive to acquisition-related spatial cues, including fundus scale and retinal position within the field of view, as well as broader non-vessel image characteristics. This framework may support interpretable disease classification, quantitative retinal phenotyping, and retinal biomarker discovery without requiring large task-specific training datasets.

0.44

Evidence-Guided Selection of Retinal Vessel Segmentation Pipelines: A Cross-Dataset Benchmark of Performance, Structure, Failure Modes, and Reproducibility

cs.CV ·2026-10-22 ·Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo +2 more
benchmark similarity 0.66
Abstract

Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structural fidelity, cross-dataset robustness, and application-specific error costs. We evaluated five executable binary vessel-segmentation pipelines (FSG-Net, SA-UNetv2, DCP-1024, GAVE, and FR-UNet) on 244 images from six public datasets using pixel-level agreement, cross-dataset stability, thin-vessel retention, structural metrics, error composition, and available computational evidence. Results were aggregated with equal weighting across datasets. No pipeline was optimal in every setting. FSG-Net achieved the highest equal-dataset mean Macro-F1 (0.77), IoU (0.63), clDice (0.83), and Skeleton F1 (0.78), whereas SA-UNetv2 achieved the highest mean sensitivity (0.85) and Thin-Vessel Sensitivity (0.63). Differences across datasets were often larger than those among the leading pipelines, and errors shared by all five methods were concentrated near annotated vessel boundaries and faint peripheral vessels. In an ancillary analysis on 45 HRF images, segmentation masks were converted into 11 ring-wise vascular features for leave-one-out classification. Controlled perturbations showed that local mask errors can be amplified in downstream features, while targeted stabilization reduced sensitivity for five features. The results support task-conditioned, benchmark-relative pipeline selection rather than a single universal ranking and highlight the need to validate the selected pipeline on the intended target domain.

0.09

RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM

cs.CV cs.LG ·2026-11-09 ·Jaafar M. Al-Ghabban, Mohammad Reza Mohammadi
similarity 0.65
Abstract

Retinal disease monitoring with optical coherence tomography angiography (OCTA) relies on segmentation of vessels and the foveal avascular zone (FAZ). Promptable models such as SEEM (Segment Everything Everywhere All at Once) allow click-based refinement, but without adaptation SEEM segments thin vessels poorly and needs many clicks. Fully fine-tuning its 342 million parameters on a few hundred images is costly and risks overfitting, and parameter-efficient methods such as low-rank adaptation (LoRA) usually adapt only the encoder. Yet SEEM reads every candidate mask from one feature map at quarter resolution, too coarse for vessels one to three pixels wide. This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution. Each candidate accesses them through its own vector and a zero-initialised projection, so the model starts exactly as SEEM. The encoder branch, a standard rank-1 LoRA, supplies the information needed to tell arteries from veins. RBA adds 0.47 million trainable parameters. Under simulated error-driven clicks, with the ground truth used only to place them, RBA outperforms LoRA, Conv-LoRA andAdaptFormer on OCTA-500 3mmlarge vessels. Averaged over three seeds, it reaches an intersection over union (IoU) of 85.16% and a Dice score of 91.93%, 2.90 and 1.72 percentage points above Conv-LoRA. On the 6 mm subset, one run gives margins of 4.35 and 2.76 points. The gain extends to arteries, veins and ROSE-O but not to the FAZ. In SEEM, adaptation capacity pays more at the mask read-out than in the encoder.

0.25

Beyond Accuracy: Benchmarking Uncertainty Quantification in Retinal Disease Screening

eess.IV ·2026-11-17 ·Mahvash Jebeli, Mohammad Eslami, Nazlee Zebardast, Lucia Sobrin, Tobias Elze
benchmarkdataset similarity 0.64
Abstract

Reliable uncertainty quantification (UQ) is essential for evaluating retinal AI systems beyond classification accuracy, yet it remains unclear whether existing UQ strategies generalize across diseases, model architectures, and reliability criteria. We introduce a large-scale, multi-disease benchmark comprising over $242,000$ fundus photographs from $32$ datasets covering diabetic retinopathy, age-related macular degeneration, and glaucoma. We evaluate six representative UQ strategies across three Vision Transformer configurations, assessing discrimination, probabilistic calibration, selective prediction, and conformal prediction-set coverage. Our findings reveal no universally superior model or UQ strategy: methods that improve reliability in one disease or architecture may underperform in another, while improvements in discrimination, calibration, and selective prediction do not necessarily align. Notably, computationally intensive methods do not consistently outperform simple confidence scores, and domain-specific foundation models and calibration-oriented loss functions do not guarantee greater reliability. In contrast, conformal prediction provides a complementary framework for achieving near-nominal marginal prediction-set coverage across diverse settings, subject to its statistical assumptions. These findings challenge universal UQ recommendations and highlight the need for disease-specific, model-specific, and multidimensional reliability evaluation before clinical deployment. We release standardized dataset splits, trained checkpoints, evaluation code, and an interactive research demonstration to support reproducible benchmarking.

0.06

HierarchiRetina: A Diabetic Retinopathy Screening and Grading Cascade with Heterogeneous Mixture-of-Experts Lesion Segmentation

cs.CV ·2026-10-13 ·Md Asif Uddin, Niloy Farhan, Rafeed Rahman, Md. Golam Rabiul Alam
code/datahot direction similarity 0.64
Abstract · 8 pages, 8 figures, 8 tables. Submitted to the IEEE Journal of Biomedical and Health Informatics. Code, trained weights and per-image predic…

Clinical screening for diabetic retinopathy proceeds in stages, yet most automated systems grade fundus images with a single black-box network. Three gaps remain: (i) lesions differ widely in size and contrast, but segmenters typically apply the same blocks to all; (ii) ungradable images are usually excluded or treated as an extra class, and lesion-aware graders seldom test whether lesions drive the grade; (iii) staged systems often report each stage only on the images reaching it, leaving propagated errors unmeasured. HierarchiRetina, a screening, segmentation and grading cascade with inspectable stage outputs, addresses each gap. First, HSMoE-AUNet is a U-Net whose skip, bottleneck and decoder blocks are sparse mixtures of heterogeneous experts, with lesion-matched types, counts and losses; SwinHRUNetPP, a dual-encoder vessel segmenter, uses a field-of-view-restricted loss. Second, LG-DRG separates gradability from ordinal severity and lets lesion masks query the image through gated cross-attention. Third, an end-to-end evaluation counts screening misses as errors and traces each error to its stage. Pooled Dice ranged from 0.184 (microaneurysms) to 0.579 (exudates); vessel Dice was 0.731. On 58,689 held-out images from six datasets, end-to-end quadratic weighted kappa was 0.804, with referral sensitivity 0.832 at specificity 0.947, and the screening gate caused 66% of errors. In ablations, the grade ignored the masks, even with the cross-attention gate started open. On all 4,105 official DDR test images, six-class accuracy was 85.6%, above the best published six-class result we found (83.8%). Staged screening systems should be evaluated end-to-end, with stage attribution and mask ablation, before clinical deployment.

0.45

Lesion-Aware Explainable AI for Diabetic Retinopathy Grading from Fundus Images

cs.CV cs.AI ·2026-11-14 ·Truong Thinh Nguyen, Hai Phong Nguyen, Truong Thanh Hung Nguyen, Giang Son Tran, Hung Cao
similarity 0.63
Abstract · 12 pages, 6 figures, 9 tables. Truong Thinh Nguyen and Hai Phong Nguyen contributed equally. Corresponding author: Truong Thinh Nguyen

Post-hoc explanations of deep-learning models for diabetic retinopathy (DR) grading are difficult to trust because different attribution methods highlight different retinal regions for the same image, and a visually plausible heatmap does not show that the highlighted pixels drive the prediction. We propose the Consensus-Calibrated Explanation Map (CCEM), which fuses Grad-CAM++, Ada-SISE, and SmoothGrad Integrated Gradients (SG-IG) using image-specific weights derived from annotation-free reliability cues: deletion sensitivity, inter-method agreement, compactness, retinal containment, and peak structure. CCEM explains a frozen ordinal grader, an EfficientNet-B7 with CBAM and a scalar regression head, pre-trained on EyePACS 2015 in Stage 1 and fine-tuned on APTOS 2019 in Stage 2 with quadratic weighted kappa (QWK)-optimized thresholds; it reaches a QWK of 0.920 on the hidden Kaggle test set and 0.559 on the external MAPLES-DR cohort. Explanations are evaluated on MAPLES-DR, 198 MESSIDOR images with expert pixel-level lesion annotations that are never used for training, threshold fitting, or fusion. On the 193 images with annotated lesions, CCEM obtains the highest Soft Pointing Game score (69.61%; 95% CI 63.7-75.3), defined as the ratio of the strongest lesion-supported saliency to the global map maximum rather than a lesion detection rate, together with the lowest deletion AUC (0.570) and the best deletion-insertion balance (0.115); each gain is significant against the strongest single explainer on paired tests. Annotation-free, per-image reliability weighting therefore turns three disagreeing explainers into one map whose peak evidence is more lesion-supported and more faithful to the model than that of any single explainer.

0.13

Retinal OCTA Phenotyping with LLM Reporting for Alzheimer's Disease

cs.CV cs.CL ·2026-09-04 ·Progga Paromita Dutta, Jeba Maliha, Md Rafiul Kabir
similarity 0.63
Abstract · 4th IEE International Conference on Artificial Intelligence, Blockchain, and Internet of Things, (AIBThings)

Early identification of Alzheimer's disease (AD) remains challenging because established assessment methods can be costly, resource-intensive, or unsuitable for population-scale screening. Optical coherence tomography angiography (OCTA) provides non-invasive visualization of retinal microvasculature, but existing approaches often require diagnostic labels and provide limited measurement-level interpretation. We present an explainable OCTA pipeline that integrates annotation-aware vessel segmentation, layer-specific vascular biomarker extraction, label-free phenotyping, and measurement-grounded LLM reporting. Using 117 ROSE-1 images from 39 subjects, we apply annotation-matched segmentation models to superficial vascular complex (SVC), deep vascular complex (DVC), and combined SVC+DVC representations. The models achieve ROC-AUC values of 0.916-0.970 and Dice scores of 0.695-0.781. Six density and fractal-dimension biomarkers form subject-level profiles for exploratory clustering. Analysis of nine held-out subjects identifies an internally consistent lower-density, lower-fractal-dimension phenotype, although the absence of diagnostic labels prevents clinical interpretation. Reports generated using GPT, Gemini, and Llama are evaluated for measurement grounding, citation faithfulness, and diagnostic caution. Overall, the framework provides a transparent, non-diagnostic connection between retinal vascular measurements, exploratory phenotyping, and evidence-linked interpretation for Alzheimer's research.

0.12

From Canon to Nikon: Camera Domain Shift and Potential Equity Implications in Retinal AI

cs.CV cs.CY ·2026-10-21 ·Lisa Y. W. Tang
similarity 0.63
Abstract

Diabetic retinopathy is a leading cause of preventable blindness, yet access to regular screening remains limited worldwide. AI offers a scalable approach, but its performance can be sensitive to image quality and acquisition conditions. In a Brazilian cohort of 8,524 patients, retinal images acquired with the Nikon NF5050 were more than twice as likely to have inadequate image quality compared with those acquired with the Canon CR-2, despite refurbished Canon systems costing more than twice as much as Nikon systems. This potential cost-quality trade-off highlights an important consideration for the reliability of AI systems deployed across heterogeneous imaging systems. Using a frozen pretrained retinal foundation model, we systematically evaluate whether camera-associated performance differences persist across 12 retinal disease classification tasks, four input resolutions, and five downstream classifiers. We find that camera-associated performance differences vary substantially across tasks, and that neither higher input resolution nor classifier choice consistently mitigates cross-camera variation. These findings identify camera platform as a potentially overlooked source of performance variability, with implications for the safety and reliability of retinal AI when deployed across heterogeneous imaging systems. We release all source code, evaluation scripts, and per-task results on GitHub to support reproducible benchmarking.

0.24