Retinal fundus photography is widely used for screening and monitoring ocular diseases, but many modern classification pipelines rely on deep latent representations and provide limited interpretability. This study develops an interpretable fundus image classification framework based on a ring-structured representation of the retinal vasculature centered on the optic disc. The method quantifies vessel geometry, color appearance, oxygenation-related vascular appearance, and vessel--background entropy within concentric retinal regions. These physiologically motivated descriptors are derived from vessel masks, image intensities, and optical-density measurements and aggregated across rings to capture spatial variation in vascular properties. Using only quantitative vascular descriptors, the proposed method achieved strong classification performance across three public fundus datasets. On HRF, it achieved 91.1\% accuracy using automatically generated vessel masks, matching RETFound, a vision transformer pretrained on large-scale retinal fundus image data, under the same evaluation setting. Additional analyses suggest that pretrained image models are sensitive to acquisition-related spatial cues, including fundus scale and retinal position within the field of view, as well as broader non-vessel image characteristics. This framework may support interpretable disease classification, quantitative retinal phenotyping, and retinal biomarker discovery without requiring large task-specific training datasets.

Closest papers

Nearest neighbours by meaning across the whole index.

A Stage-Wise Explainable Pipeline for Arteriolar-to-Venular Ratio Estimation and Retinopathy Screening

cs.CV cs.AI ·2026-11-10 ·Sharan Sharmeela Karuppannan, Yoga Sri Varshan, Subin Sahayam, Umarani Jayaraman
published similarity 0.69
Abstract · Accepted for presentation at the 23rd IEEE India Council International Conference (INDICON 2026)

The arteriolar-to-venular diameter ratio (AVR) is a clinically motivated marker of retinal vascular health. We present a five-stage pipeline for AVR estimation and exploratory retinopathy screening from fundus images, with inspectable intermediate outputs at each stage. The pipeline combines vessel and artery-vein masks, optic-disc localization, vessel-calibre estimation using a minimal-chord boundary walk, and AVR computation from dominant arterial and venular branches. An explicit threshold-based rule produces the screening decision, enabling errors to be traced to individual processing stages. On an exploratory cohort of 30 HRF images, we report 96.7% accuracy, an F1-score of 0.968 and ROC-AUC of 0.978. Ablation studies and an exploratory comparison with VascX examine the effects of vessel pairing, calibre measurement and aggregation. Interpretation is limited by the small cohort, proxy disease labels and absence of independent reference calibre measurements. The pipeline provides a transparent framework for investigating retinal vascular biomarkers, with further validation needed on larger, clinically graded cohorts.

0.32

LightHybridNet: A Lightweight Hybrid Deep Learning Framework for Efficient Multi-Label Ophthalmic Disease Classification in Imbalanced Fundus Images

eess.IV ·2026-10-14 ·Hem Raj Dadral Najam Ul Hasan, Naveed Ejaz, Muhammad Aslam Jarwar
similarity 0.69
Abstract

Eye diseases are a major global cause of blindness and vision impairment, highlighting the need for accurate and early diagnosis to prevent further deterioration. Despite advances in medical imaging, classifying retinal diseases from fundus images remains challenging due to the complexity and subtlety of visual features. This study aims to develop and validate LightHybridNet, a novel lightweight hybrid deep learning framework, to improve the classification of eye diseases from fundus images. The model incorporates architectural features, such as depthwise separable convolutions and compound scaling mechanisms, to enhance diagnostic accuracy and robustness. To validate the model, the ODIR-5K dataset, comprising 8 disease categories, was used. To enhance image quality, pre-processing approaches were applied, including histogram equalisation, colour space conversion, and contrast adjustment, resulting in high-resolution images. Furthermore, image augmentation was employed to increase the dataset size, thereby improving the model's ability to generalise during training. The hybrid architecture helps the model concentrate on relevant image regions while capturing and integrating details at different scales, significantly improving classification performance. To evaluate its effectiveness, the model was compared with transfer-learning models. The results show that LightHybridNet outperforms the baselines, achieving a weighted F1-score of 91.51%, a macro AUC of 98.26%, and a Cohen's Kappa of 90.14% on the validation set. Furthermore, model interpretability was enhanced using explainable AI methods, including Grad-CAM, to identify and emphasise features influencing the decision-making process. LightHybridNet represents a promising advancement in automated ocular disease detection, offering improved diagnostic reliability for clinical use.

0.20

Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa

cs.CV cs.AI ·2026-09-22 ·Charis Y. N. Chiang, Tarela Sarimiye, Adeyinka Ashaye, Martin Buist, Michael A. Hauser +2 more
similarity 0.67
Abstract · 31 pages, 2 Tables, 5 Figures, 1 Supplementary Material

Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83$\pm$0.03 (Volk) and 0.87$\pm$0.04 (Canon); Classification model: AUCs of 0.85$\pm$0.01 (Volk) and 0.93$\pm$0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.

0.32

Optic Disc Segmentation in Fundus Images: From Classical Image Processing and Deformable Models to Modern AI

eess.IV cs.CV ·2026-08-18 ·Buket D. Barkana
similarity 0.67
Abstract

Accurate localization and segmentation of the optic disc (OD) are important for retinal image analysis and glaucoma assessment, yet remain challenging due to variations in illumination, pathology, vascular interference, and poorly defined boundaries. This structured methodological review examines the evolution of OD segmentation from classical image-processing and deformable models to contemporary artificial intelligence (AI)-based approaches. A structured literature search and study-selection process was used to identify representative studies spanning major methodological developments. The review first summarizes commonly used fundus-image datasets, then organizes classical methods by principal mechanisms, including intensity and thresholding, histogram and entropy analysis, morphology, geometric and Hough-transform methods, filtering and feature operators, texture- and region-based approaches, and active-contour and level-set models. This paper pays particular attention to the assumptions, strengths, limitations, and complementary roles of these methods in OD localization and boundary delineation. Representative AI approaches are subsequently examined to illustrate the transition from handcrafted features and explicitly defined priors to learned representations, Transformer-based segmentation, boundary- and shape-aware learning, promptable segmentation, and retinal foundation models. Across these methodological generations, several core segmentation principles persist, including region-of-interest localization, multiscale representation, geometric and anatomical constraints, and boundary regularization, although their implementation has shifted from predefined operators to learned modules, losses, prompts, and pretrained representations. The review further identifies boundary ambiguity, anatomical variability, domain shift, and cross-dataset generalization as continuing challenges.

0.27

Domain-Specific Self-Supervised Representation Learning for Retinal Fundus Classification

cs.CV cs.LG ·2026-08-27 ·Bekzat Nurlanbekova, Fung Fung Ting
similarity 0.67
Abstract

Annotated medical images remain scarce and costly to obtain, which motivates self-supervised learning (SSL). We present a controlled empirical study of two SSL frameworks, SimSiam and SimCLR, for retinal fundus classification, asking whether retina-specific augmentations (Graham's local-mean subtraction and CLAHE) improve representations beyond standard augmentation and grayscale conversion. ResNet-18 backbones are pretrained on 48K unlabeled fundus images and evaluated by linear probing and fine-tuning on EDID (multi-disease) and RetinaMNIST (DR grading). On EDID, grayscale conversion accounts for most of SimSiam's linear-probe gain, and Graham or CLAHE add little on top of it. After fine-tuning, SimSiam with Graham+Gray exceeds an ImageNet-supervised baseline on RetinaMNIST (+3.0 accuracy points) but only matches it on EDID. Retina-specific augmentation therefore helps inconsistently and should be validated per SSL method and task.

0.14

Braided Vision Transformer for Stroke Detection in Multi-view Retinal Fundus Imaging

cs.CV ·2026-08-12 ·Aysen Degerli, Mika Hilvo
similarity 0.66
Abstract

Stroke remains a leading cause of mortality and morbidity worldwide, emphasizing the importance of its accurate and immediate assessment. Retinal fundus imaging has emerged as a promising modality for stroke assessment, as the retina reflects cerebrovascular and neurological risk factors. Contrary to conventional neuroimaging techniques, retinal fundus imaging offers a non-invasive, cost-effective, and portable alternative for rapid screening. This paper explores the feasibility of retinal fundus imaging for stroke and transient ischemic attack (TIA) detection using macula-centric and optic nerve head-centric views captured from both eyes. Our study introduces, to the best of our knowledge, the first vision transformer model for retinal fundus imaging in stroke assessment, offering a novel approach for capturing retinal patterns. Thereby, we propose the Braided Vision Transformer (BViT) model, which extracts representative features from the given multi-view images while simultaneously capturing inter-view relationships across both eyes, enabling a more informative understanding of retinal biomarkers associated with cerebrovascular events. Experiments conducted on our collected Stroke-Data dataset demonstrate that BViT achieves an AUC score of 0.75 for stroke detection, outperforming regular vision transformers.

0.04

Explainable Diabetic Retinopathy Classification Using Vision Foundation Models

cs.CV cs.LG ·2026-08-28 ·Abhishek Verma, Anila Krishna, Abhishek Gajanan Bankar, Juan Miguel Lopez Alcaraz
code/data similarity 0.66
Abstract · 17 pages, 4 figures, source code under https://github.com/UOLMDA26/retinopathy_vision_foundational

Diabetic retinopathy (DR) is a leading cause of preventable blindness, and automated screening must be both accurate and trustworthy. We study an explainable DR classification framework built on vision foundation models and three transfer learning strategies. Three backbones, DINOv2, CLIP, and Vision Transformer (ViT), were adapted by full fine-tuning, linear probing, and Low-Rank Adaptation (LoRA). Models were trained and internally evaluated on the ODIR dataset and externally evaluated on APTOS to assess generalization. DINOv2-LoRA achieved the highest internal AUROC (0.758), whereas DINOv2 and ViT full fine-tuning achieved the highest external AUROC (0.920). Probability calibration was assessed with reliability analysis after isotonic regression. For explainability, Grad-CAM and HiResCAM maps were compared with expert-annotated lesion masks from the IDRiD dataset using Dice, Intersection over Union (IoU), and Pointing Game metrics. The results show that foundation models, particularly DINOv2, provide strong predictive performance, and that LoRA is a parameter-efficient alternative to full fine-tuning. Spatial overlap between explanation maps and annotated lesions was limited (mean Dice of about 0.13 for the combined lesion mask), which highlights the value of quantitatively testing whether model attention corresponds to clinically relevant retinal lesions.

0.23

From Canon to Nikon: Camera Domain Shift and Potential Equity Implications in Retinal AI

cs.CV cs.CY ·2026-10-21 ·Lisa Y. W. Tang
similarity 0.65
Abstract

Diabetic retinopathy is a leading cause of preventable blindness, yet access to regular screening remains limited worldwide. AI offers a scalable approach, but its performance can be sensitive to image quality and acquisition conditions. In a Brazilian cohort of 8,524 patients, retinal images acquired with the Nikon NF5050 were more than twice as likely to have inadequate image quality compared with those acquired with the Canon CR-2, despite refurbished Canon systems costing more than twice as much as Nikon systems. This potential cost-quality trade-off highlights an important consideration for the reliability of AI systems deployed across heterogeneous imaging systems. Using a frozen pretrained retinal foundation model, we systematically evaluate whether camera-associated performance differences persist across 12 retinal disease classification tasks, four input resolutions, and five downstream classifiers. We find that camera-associated performance differences vary substantially across tasks, and that neither higher input resolution nor classifier choice consistently mitigates cross-camera variation. These findings identify camera platform as a potentially overlooked source of performance variability, with implications for the safety and reliability of retinal AI when deployed across heterogeneous imaging systems. We release all source code, evaluation scripts, and per-task results on GitHub to support reproducible benchmarking.

0.24