CS Paper Radar

Optic Disc Segmentation in Fundus Images: From Classical Image Processing and Deformable Models to Modern AI

Buket D. Barkana

eess.IV cs.CV ·submitted 2026-08-18 22:39 UTC · v1

Abstract

Accurate localization and segmentation of the optic disc (OD) are important for retinal image analysis and glaucoma assessment, yet remain challenging due to variations in illumination, pathology, vascular interference, and poorly defined boundaries. This structured methodological review examines the evolution of OD segmentation from classical image-processing and deformable models to contemporary artificial intelligence (AI)-based approaches. A structured literature search and study-selection process was used to identify representative studies spanning major methodological developments. The review first summarizes commonly used fundus-image datasets, then organizes classical methods by principal mechanisms, including intensity and thresholding, histogram and entropy analysis, morphology, geometric and Hough-transform methods, filtering and feature operators, texture- and region-based approaches, and active-contour and level-set models. This paper pays particular attention to the assumptions, strengths, limitations, and complementary roles of these methods in OD localization and boundary delineation. Representative AI approaches are subsequently examined to illustrate the transition from handcrafted features and explicitly defined priors to learned representations, Transformer-based segmentation, boundary- and shape-aware learning, promptable segmentation, and retinal foundation models. Across these methodological generations, several core segmentation principles persist, including region-of-interest localization, multiscale representation, geometric and anatomical constraints, and boundary regularization, although their implementation has shifted from predefined operators to learned modules, losses, prompts, and pretrained representations. The review further identifies boundary ambiguity, anatomical variability, domain shift, and cross-dataset generalization as continuing challenges.

Closest papers

Nearest neighbours by meaning across the whole index.

Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa

cs.CV cs.AI ·2026-09-22 ·Charis Y. N. Chiang, Tarela Sarimiye, Adeyinka Ashaye, Martin Buist, Michael A. Hauser +2 more
similarity 0.68
Abstract · 31 pages, 2 Tables, 5 Figures, 1 Supplementary Material

Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83$\pm$0.03 (Volk) and 0.87$\pm$0.04 (Canon); Classification model: AUCs of 0.85$\pm$0.01 (Volk) and 0.93$\pm$0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.

0.32

Interpretable Fundus Image Classification via Ring-Based Retinal Vasculature Features

cs.CV stat.ML ·2026-08-25 ·Xiaoyan Li, Shixin Xu, Arvind Gupta, Huaxiong Huang
similarity 0.67
Abstract

Retinal fundus photography is widely used for screening and monitoring ocular diseases, but many modern classification pipelines rely on deep latent representations and provide limited interpretability. This study develops an interpretable fundus image classification framework based on a ring-structured representation of the retinal vasculature centered on the optic disc. The method quantifies vessel geometry, color appearance, oxygenation-related vascular appearance, and vessel--background entropy within concentric retinal regions. These physiologically motivated descriptors are derived from vessel masks, image intensities, and optical-density measurements and aggregated across rings to capture spatial variation in vascular properties. Using only quantitative vascular descriptors, the proposed method achieved strong classification performance across three public fundus datasets. On HRF, it achieved 91.1\% accuracy using automatically generated vessel masks, matching RETFound, a vision transformer pretrained on large-scale retinal fundus image data, under the same evaluation setting. Additional analyses suggest that pretrained image models are sensitive to acquisition-related spatial cues, including fundus scale and retinal position within the field of view, as well as broader non-vessel image characteristics. This framework may support interpretable disease classification, quantitative retinal phenotyping, and retinal biomarker discovery without requiring large task-specific training datasets.

0.44

Bayesian-Optimized Superpixel-GrabCut for Traceable Optic Disc Segmentation

cs.CV eess.IV ·2026-08-29 ·Shraddha Changune, Vivek Noel Soren, Gautam Das, Tapan Kumar Gandhi
published similarity 0.65
Abstract · Accepted at 15th International Conference on Image Processing Theory, Tools and Applications 2026

Optic disc (OD) segmentation is essential for diagnosing ophthalmic pathologies from retinal fundus images. However, prevailing deep learning approaches operate as opaque black boxes, lacking the inference-stage mathematical traceability--a critical requirement for algorithmic auditing and failure analysis in clinical workflows. This paper presents a fully algorithmically traceable and trainable segmentation pipeline that jointly combines superpixel decomposition, hybrid brightness-proximity superpixel scoring, morphological regularization, iterative GrabCut refinement, and elliptical shape fitting. The hyperparameter optimization is formulated as an objective function and solved via Bayesian optimization to eliminate manual parameter tuning. A quantitative evaluation on the Drishti-GS dataset demonstrates that our method achieves a Dice coefficient of 0.9536, matching state-of-the-art performance. By maintaining explicit mathematical transparency across all processing stages, our framework offers a deterministic, traceable alternative to black-box architectures for medical review and debugging.

0.23

Where to Predict in Retinal OCT? Anatomy-Guided Target Selection for I-JEPA

cs.CV ·2026-11-12 ·Yunchu Feng, Wai Tak Lau, Kaveri A. Thakoor
published similarity 0.62
Abstract · 18 pages. Accepted as a poster at the GenAI for Health Workshop at NeurIPS 2026 (non-archival)

Self-supervised learning aims to learn meaningful representations from unlabeled data, potentially allowing models to capture subtle anatomical variations across patients and reduce the amount of labeled data needed. Image-based Joint-Embedding Predictive Architecture (I-JEPA) learns by predicting target-region representations from visible context rather than reconstructing pixels. However, its uniform target placement does not account for the anatomical structure of retinal OCT, where retinal tissue occupies only part of each B-scan. We investigate anatomy-guided target selection using image intensity and predicted retinal segmentation while retaining the I-JEPA architecture and latent prediction objective. We compare anatomy-guided rectangular targets, anatomy-shaped targets and coverage-constrained placement with uniform masking, and evaluate the learned representations using linear probing for glaucoma classification on FairVision. We found that rectangular targets guided by image intensity achieved the highest linear-probe AUC in our comparisons. We show that anatomically meaningful target selection is promising for retinal OCT representation learning, while greater anatomical specificity did not consistently improve performance.

0.35

OptiModNet: A UNet-Transformer Hybrid with Grouped-Query and Channel Attention for Optic Disc and Cup Segmentation

cs.CV cs.AI ·2026-08-19 ·Soumili Ghosh, Debapriya Roy, Aryan Das, Bikash Santra
code/data similarity 0.60
Abstract

Precise segmentation of the optic disc and cup is critical for the early detection and diagnosis of glaucoma. However, achieving consistently high performance across datasets while maintaining low computational requirements remains a significant challenge. In glaucoma detection, low-computation methods are crucial for enabling rapid, large-scale screening and facilitating deployment in resource-limited clinical environments. While deep learning models such as UNets, Vision Transformers (ViTs), and Diffusion models have demonstrated strong segmentation performance but these methods often come with substantial computational overhead. UNets are efficient at capturing local features but are limited in modeling global contextual information. Conversely, ViTs excel at long-range dependency modeling but are computationally intensive. Hybrid architectures, such as UNetR, which combine transformer-based encoders with UNet-style decoders, have shown improved performance but while incurring additional complexity. Considering these, in this work, we propose OptiModNet, a light weight novel hybrid architecture tailored for optic disc and cup segmentation. The model integrates diverse attention mechanisms at multiple stages of the network to enhance both local and global feature representation. We include an Aggregated Pyramid Loss that supervises predictions at multiple decoder depths, to promote better gradient flow and structural consistency. We evaluate OptiModNet on the REFUGE2 dataset for both optic disc and cup segmentation tasks. Our method achieves state-of-the-art performance, exceeding existing approaches by over 2.5\%, while maintaining high efficiency with only 3.73 GFLOPs and 1.93M parameters. The code is available at https://github.com/SG1947/OptiModNet.

0.24

A Stage-Wise Explainable Pipeline for Arteriolar-to-Venular Ratio Estimation and Retinopathy Screening

cs.CV cs.AI ·2026-11-10 ·Sharan Sharmeela Karuppannan, Yoga Sri Varshan, Subin Sahayam, Umarani Jayaraman
published similarity 0.60
Abstract · Accepted for presentation at the 23rd IEEE India Council International Conference (INDICON 2026)

The arteriolar-to-venular diameter ratio (AVR) is a clinically motivated marker of retinal vascular health. We present a five-stage pipeline for AVR estimation and exploratory retinopathy screening from fundus images, with inspectable intermediate outputs at each stage. The pipeline combines vessel and artery-vein masks, optic-disc localization, vessel-calibre estimation using a minimal-chord boundary walk, and AVR computation from dominant arterial and venular branches. An explicit threshold-based rule produces the screening decision, enabling errors to be traced to individual processing stages. On an exploratory cohort of 30 HRF images, we report 96.7% accuracy, an F1-score of 0.968 and ROC-AUC of 0.978. Ablation studies and an exploratory comparison with VascX examine the effects of vessel pairing, calibre measurement and aggregation. Interpretation is limited by the small cohort, proxy disease labels and absence of independent reference calibre measurements. The pipeline provides a transparent framework for investigating retinal vascular biomarkers, with further validation needed on larger, clinically graded cohorts.

0.32

Automated 2D and 3D Segmentation of AMD and DME Lesions in OCT

cs.CV ·2026-08-27 ·Lucia Sundberg, Zhihao Zhao, M. Ali Nasseri
similarity 0.60
Abstract

Age-related macular degeneration (AMD) and diabetic macular edema (DME) are leading causes of vision loss, and optical coherence tomography (OCT) is the standard modality for detecting and monitoring the subtle lesions that drive treatment decisions. Most deep-learning segmentation work for OCT is validated only in-domain, leaving generalization to clinical data collected under different acquisition protocols largely untested. This work develops and systematically ablates four lesion-segmentation pipelines -- 2D and 3D variants for AMD and DME -- reaching Dice scores of 0.76 to 0.82 with strong volumetric and surface calibration (r vol, r surf greater than or equal to 0.97 across all four pipelines) on an in-domain validation set. The ablation process establishes a full-volume, calibration-aware adoption standard that catches mechanisms an ordinary slice-level evaluation would keep, and identifies ensemble composition as the most consistent driver of improvement. To test generalization, the models are evaluated on OLIVES, an external clinical cohort with no lesion-level ground truth, using a proxy-metric framework built around biomarker AUROC, central subfield thickness (CST) correlation, and longitudinal concordance. Predictions track clinical biomarkers outside the training distribution, though less strongly than in-domain -- evidence for, not validation of, automated lesion-burden tracking as a clinical tool.

0.25

Modelling Geographic Atrophy Progression using Implicit Neural Representations

cs.CV cs.AI ·2026-08-11 ·Simone Sarrocco, Paul Friedrich, Florentin Bieder, Christina Bornberg, Philippe Valmaggia +2 more
publishedcode/data similarity 0.60
Abstract · Accepted at MICCAI 2026 Off-Grid Workshop

Age-related Macular Degeneration (AMD) is the major cause of blindness in the Western world. Its late dry phase is characterised by irreversible atrophic areas, namely Geographic Atrophy (GA). Longitudinal Fundus Autofluorescence (FAF) image acquisitions are currently the main tool for assessing lesion growth over time at the image level. However, due to its highly individualised progression, the evolution of late AMD remains poorly understood. In this work, we propose using Implicit Neural Representations (INRs) to model GA progression at the individual level in a low-data setting. Our approach generates both FAF and GA segmentation at both past and future time points. Among the comparison models, our method achieves competitive segmentation quality across different scenarios, yielding the lowest Mean Absolute Error (MAE) for the GA lesion area and the highest DICE score, without sacrificing FAF image quality. The code is available at https://github.com/SimoneSarrocco/ga-progression-with-inrs.

0.38