CS Paper Radar

Automated 2D and 3D Segmentation of AMD and DME Lesions in OCT

Lucia Sundberg, Zhihao Zhao, M. Ali Nasseri

cs.CV ·submitted 2026-08-27 13:13 UTC · v1

Abstract

Age-related macular degeneration (AMD) and diabetic macular edema (DME) are leading causes of vision loss, and optical coherence tomography (OCT) is the standard modality for detecting and monitoring the subtle lesions that drive treatment decisions. Most deep-learning segmentation work for OCT is validated only in-domain, leaving generalization to clinical data collected under different acquisition protocols largely untested. This work develops and systematically ablates four lesion-segmentation pipelines -- 2D and 3D variants for AMD and DME -- reaching Dice scores of 0.76 to 0.82 with strong volumetric and surface calibration (r vol, r surf greater than or equal to 0.97 across all four pipelines) on an in-domain validation set. The ablation process establishes a full-volume, calibration-aware adoption standard that catches mechanisms an ordinary slice-level evaluation would keep, and identifies ensemble composition as the most consistent driver of improvement. To test generalization, the models are evaluated on OLIVES, an external clinical cohort with no lesion-level ground truth, using a proxy-metric framework built around biomarker AUROC, central subfield thickness (CST) correlation, and longitudinal concordance. Predictions track clinical biomarkers outside the training distribution, though less strongly than in-domain -- evidence for, not validation of, automated lesion-burden tracking as a clinical tool.

Closest papers

Nearest neighbours by meaning across the whole index.

Comparative Evaluation of Deep Learning Models for Geographic Atrophy Segmentation in En Face OCT Images

cs.CV ·2026-11-09 ·Utkarsh Doshi, Adarsh Gadari, Sharat Chandra Vupparaboina, Joseph DeCicco, Giulia Gregori +7 more
similarity 0.71
Abstract · 30 pages, 11 figures

Background: Geographic atrophy (GA) is an advanced form of age-related macular degeneration (AMD). It causes irreversible vision loss due to progressive degeneration of the retinal pigment epithelium (RPE) and photoreceptors. Accurate segmentation of GA in en-face image is crucial for early diagnosis, monitoring disease progression, and developing personalized treatment strategies. However, existing deep learning approaches are typically evaluated using single architectures and single-device datasets, limiting insight into relative performance and cross-device robustness. Methods: We trained and systematically compared five deep learning architectures for GA segmentation: Nested U-Net, ResU-Net, nnUnet, Swin-Unet and MedSegDiff model, together with a thresholding based classical baseline. The models were trained on a dataset of en-face OCT images derived from 269 OCT volumes from two different devices, following a three-step preprocessing technique involving normalization and inpainting to enhance the quality of the en-face images. Results: On the fixed held-out validation set comprising OCT scans from both Cirrus (R) (Carl Zeiss Meditec, Inc., USA) and Spectralis (R) (Heidelberg Engineering, Germany) devices, nnUnet achieved the highest mean Dice similarity coefficient (DSC) of 0.8882 +/- 0.0033. The other models yielded the following Dice scores: Nested U-Net (0.7932 +/- 0.0423), ResU-Net (0.8453 +/- 0.0074), Swin-Unet (0.6886 +/- 0.0294), and Diffusion model (0.7959 +/- 0.0242). Conclusions: nnUnet framework, demonstrated most reliable performance for GA segmentation in en-face OCT under limited data conditions. It offers the best balance of accuracy, stability, and efficiency for GA quantification.

0.20

A Novel Conditional Adversarial Diffusion Model for High-Fidelity OCT-to-OCT Image Translation and Precise Anti-VEGF Therapy Response Prediction in Diabetic Macular Edema

eess.IV cs.CV ·2026-11-02 ·Reza Rasti, Armin Biglari, Sobhan Mohammadi Hafshejani, Alireza Dehghani, Michael J. Allingham +1 more
code/data similarity 0.70
Abstract · 18 pages, 8 figures, 6 tables, Submitted to IEEE Journal of Biomedical and Health Informatics

Diabetic macular edema (DME) is a leading cause of severe vision loss among working-age adults. Although intravitreal anti-vascular endothelial growth factor (anti-VEGF) injections currently serve as the first-line therapy for DME, a notable subset of patients fails to respond despite the substantial cost and clinical burden, suggesting they may benefit more from alternative interventions. Automated, noninvasive pre-treatment response assessment could therefore spare non-responders from the current trial-and-error treatment paradigm. In this study, we propose a novel conditional adversarial diffusion framework that synthesizes post-treatment optical coherence tomography (OCT) images from baseline scans, enabling the derivation of each patient's initial response to anti-VEGF therapy. The model was developed with subject-level 5-fold cross-validation on a US cohort (n = 127) and externally validated on an independent Iranian cohort (n = 44). Benchmarked against fourteen baseline and state-of-the-art translation models, the proposed model achieved the best treatment-response prediction performance among the methods evaluated for that task on both cohorts, with balanced accuracies of 85.7% and 93.0% on the US cohort and 85.2% and 95.3% on the external Iranian cohort at the 10% and 20% central subfield thickness reduction thresholds, respectively. Ultimately, this framework offers a decision-support tool to help ophthalmologists anticipate initial anti-VEGF outcomes in DME prior to treatment initiation, toward personalized therapy selection. The source code will be made publicly available upon acceptance.

0.40

Retinal OCTA Phenotyping with LLM Reporting for Alzheimer's Disease

cs.CV cs.CL ·2026-09-04 ·Progga Paromita Dutta, Jeba Maliha, Md Rafiul Kabir
similarity 0.68
Abstract · 4th IEE International Conference on Artificial Intelligence, Blockchain, and Internet of Things, (AIBThings)

Early identification of Alzheimer's disease (AD) remains challenging because established assessment methods can be costly, resource-intensive, or unsuitable for population-scale screening. Optical coherence tomography angiography (OCTA) provides non-invasive visualization of retinal microvasculature, but existing approaches often require diagnostic labels and provide limited measurement-level interpretation. We present an explainable OCTA pipeline that integrates annotation-aware vessel segmentation, layer-specific vascular biomarker extraction, label-free phenotyping, and measurement-grounded LLM reporting. Using 117 ROSE-1 images from 39 subjects, we apply annotation-matched segmentation models to superficial vascular complex (SVC), deep vascular complex (DVC), and combined SVC+DVC representations. The models achieve ROC-AUC values of 0.916-0.970 and Dice scores of 0.695-0.781. Six density and fractal-dimension biomarkers form subject-level profiles for exploratory clustering. Analysis of nine held-out subjects identifies an internally consistent lower-density, lower-fractal-dimension phenotype, although the absence of diagnostic labels prevents clinical interpretation. Reports generated using GPT, Gemini, and Llama are evaluated for measurement grounding, citation faithfulness, and diagnostic caution. Overall, the framework provides a transparent, non-diagnostic connection between retinal vascular measurements, exploratory phenotyping, and evidence-linked interpretation for Alzheimer's research.

0.12

Bayesian-Optimized Superpixel-GrabCut for Traceable Optic Disc Segmentation

cs.CV eess.IV ·2026-08-29 ·Shraddha Changune, Vivek Noel Soren, Gautam Das, Tapan Kumar Gandhi
published similarity 0.67
Abstract · Accepted at 15th International Conference on Image Processing Theory, Tools and Applications 2026

Optic disc (OD) segmentation is essential for diagnosing ophthalmic pathologies from retinal fundus images. However, prevailing deep learning approaches operate as opaque black boxes, lacking the inference-stage mathematical traceability--a critical requirement for algorithmic auditing and failure analysis in clinical workflows. This paper presents a fully algorithmically traceable and trainable segmentation pipeline that jointly combines superpixel decomposition, hybrid brightness-proximity superpixel scoring, morphological regularization, iterative GrabCut refinement, and elliptical shape fitting. The hyperparameter optimization is formulated as an objective function and solved via Bayesian optimization to eliminate manual parameter tuning. A quantitative evaluation on the Drishti-GS dataset demonstrates that our method achieves a Dice coefficient of 0.9536, matching state-of-the-art performance. By maintaining explicit mathematical transparency across all processing stages, our framework offers a deterministic, traceable alternative to black-box architectures for medical review and debugging.

0.23

Seeing the Small: Deformable Duality Mamba for Retinal Lesion Segmentation

cs.CV cs.LG ·2026-11-10 ·Chang Yu, Siqing Li, Yuanchen Liu, Zhenyu Bu, Luming Yang +1 more
code/data similarity 0.66
Abstract · 5 pages, 4 figures, 1 table

Diabetic retinopathy (DR) lesions vary widely in shape, and microaneurysms (MAs) span only a few pixels. We hypothesize that modeling the spatial organization of lesion regions, with global context and shape-adaptive scanning, improves the segmentation of such small and irregular lesions. To test this, we propose D$^2$Mamba, which couples non-causal state space duality with deformable Mamba scanning. We evaluate it with five-fold cross-validation on the DDR dataset, comparing against representative segmentation baselines under an identical training protocol, and conduct ablations on each component. D$^2$Mamba achieved the best overall performance, with 33.87% mIoU, 2.99 percentage points above the strongest baseline. The largest gain appeared on MAs, the smallest and most easily missed lesions, where Dice improved by 10.06 percentage points. These results confirm our hypothesis that spatially adaptive state space modeling benefits tiny-lesion segmentation. Code and pretrained weights are available at https://github.com/PUREPANEL1/D2Mamba.

0.47

Exploring the Latent Structure of AMD Severity Using Retinal Foundation Models

eess.IV cs.CV ·2026-10-09 ·Niccolò Fineschi, Jovana Panic, Atsushi Watanabe, Hideaki Hayashi, Kazuya Nishimura +5 more
published similarity 0.65
Abstract · 7 pages, 5 figures. Accepted for publication at IEEE EMBS BHI 2026

Retinal foundation models have demonstrated strong performance across a wide range of ophthalmic tasks, yet relatively little is known about how disease-related information is represented within their learned embeddings and whether this distribution influences downstream prediction performance. In this work, we use Age-related Macular Degeneration (AMD) as a case study to investigate how disease severity is represented within the embedding space of RET-CLIP, a retinal vision-language foundation model, using bilateral fundus images from the AREDS dataset, benchmarked against non-retinal encoders. We first characterize the distribution of AMD severity within the learned representation space and then evaluate how this structure influences classification performance across three clinically relevant task formulations of increasing granularity. Finally, we analyze the most influential latent dimensions combining feature attribution, statistical phenotype association, and qualitative image analyses. Our results show that RET-CLIP represents AMD severity as a continuous spectrum rather than a set of discrete categories, with healthy and advanced disease stages exhibiting clearer separation than intermediate ones. This organization was reflected in downstream performance, which decreased from a balanced accuracy of 0.844 and 0.814 for binary AMD and Late-AMD detection respectively to 0.446 for six-class grading. Furthermore, the most influential latent dimensions were statistically associated to distinct retinal phenotypes, including drusen accumulation, pigmentary alterations, and advanced retinal lesions. These findings suggest that the structure of retinal foundation-model representations influences the difficulty of clinically relevant prediction tasks and demonstrate the potential of representation-level analysis for understanding disease organization and improving interpretability.

0.18

FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs

cs.CV cs.AI ·2026-09-27 ·David Restrepo, Chenwei Wu, Luis Filipe Nakayama, Miguel L. Martins, Stergios Christodoulidis +2 more
top venuebenchmarkdatasetcode/data similarity 0.65
Abstract · Accepted at NeurIPS 2026, Evaluations & Datasets Track. Interactive benchmark dashboard: https://huggingface.co/spaces/dsrestrepo/FOCUS-Reti…

Progress in AI-based retinal image analysis has accelerated with the adoption of foundation models, yet evaluating their real-world reliability remains challenging. Performance reported on a single dataset does not capture how models behave under dataset shift, across clinical definitions, or for different patient subgroups. This limitation is particularly critical in medical imaging, where robustness, calibration, and fairness are essential for safe deployment. We introduce FOCUS (Foundation Ophthalmic Cross-Dataset Understanding under Shift), a cross-dataset benchmark evaluating retinal fundus models across vision-only encoder models (VM), vision-language dual-encoder models (VLM), and multimodal large language models (MLLM). FOCUS harmonizes binary diabetic retinopathy, referable diabetic retinopathy, and glaucomatous optic neuropathy tasks across ten public datasets spanning diverse geographies, acquisition conditions, and label protocols. The benchmark evaluates models through a unified analysis layer that measures ranking performance, calibration, subgroup disparities, and image-quality robustness. We present a large-scale evaluation covering 532 base configurations and 228 MLLM configurations adapted via LoRA fine-tuning. Results show no model family consistently dominates across tasks and datasets: general VM encoders achieve the strongest average ranking performance, medical MLLMs are competitive but variable, and dual-encoder VLMs benefit substantially from lightweight adaptation. Fine-tuning improves in-domain performance but exhibits heterogeneous transfer to external datasets, particularly in calibration. FOCUS provides a practical framework and public benchmark to assess generalization, reliability, and robustness beyond single-dataset leaderboards.

0.52

HierarchiRetina: A Diabetic Retinopathy Screening and Grading Cascade with Heterogeneous Mixture-of-Experts Lesion Segmentation

cs.CV ·2026-10-13 ·Md Asif Uddin, Niloy Farhan, Rafeed Rahman, Md. Golam Rabiul Alam
code/datahot direction similarity 0.65
Abstract · 8 pages, 8 figures, 8 tables. Submitted to the IEEE Journal of Biomedical and Health Informatics. Code, trained weights and per-image predic…

Clinical screening for diabetic retinopathy proceeds in stages, yet most automated systems grade fundus images with a single black-box network. Three gaps remain: (i) lesions differ widely in size and contrast, but segmenters typically apply the same blocks to all; (ii) ungradable images are usually excluded or treated as an extra class, and lesion-aware graders seldom test whether lesions drive the grade; (iii) staged systems often report each stage only on the images reaching it, leaving propagated errors unmeasured. HierarchiRetina, a screening, segmentation and grading cascade with inspectable stage outputs, addresses each gap. First, HSMoE-AUNet is a U-Net whose skip, bottleneck and decoder blocks are sparse mixtures of heterogeneous experts, with lesion-matched types, counts and losses; SwinHRUNetPP, a dual-encoder vessel segmenter, uses a field-of-view-restricted loss. Second, LG-DRG separates gradability from ordinal severity and lets lesion masks query the image through gated cross-attention. Third, an end-to-end evaluation counts screening misses as errors and traces each error to its stage. Pooled Dice ranged from 0.184 (microaneurysms) to 0.579 (exudates); vessel Dice was 0.731. On 58,689 held-out images from six datasets, end-to-end quadratic weighted kappa was 0.804, with referral sensitivity 0.832 at specificity 0.947, and the screening gate caused 66% of errors. In ablations, the grade ignored the masks, even with the cross-attention gate started open. On all 4,105 official DDR test images, six-class accuracy was 85.6%, above the best published six-class result we found (83.8%). Staged screening systems should be evaluated end-to-end, with stage attribution and mask ablation, before clinical deployment.

0.45