HierarchiRetina: A Diabetic Retinopathy Screening and Grading Cascade with Heterogeneous Mixture-of-Experts Lesion Segmentation

Md Asif Uddin, Niloy Farhan, Rafeed Rahman, Md. Golam Rabiul Alam

cs.CV ·submitted 2026-10-13 08:19 UTC · v1
code/datahot direction

Abstract

Clinical screening for diabetic retinopathy proceeds in stages, yet most automated systems grade fundus images with a single black-box network. Three gaps remain: (i) lesions differ widely in size and contrast, but segmenters typically apply the same blocks to all; (ii) ungradable images are usually excluded or treated as an extra class, and lesion-aware graders seldom test whether lesions drive the grade; (iii) staged systems often report each stage only on the images reaching it, leaving propagated errors unmeasured. HierarchiRetina, a screening, segmentation and grading cascade with inspectable stage outputs, addresses each gap. First, HSMoE-AUNet is a U-Net whose skip, bottleneck and decoder blocks are sparse mixtures of heterogeneous experts, with lesion-matched types, counts and losses; SwinHRUNetPP, a dual-encoder vessel segmenter, uses a field-of-view-restricted loss. Second, LG-DRG separates gradability from ordinal severity and lets lesion masks query the image through gated cross-attention. Third, an end-to-end evaluation counts screening misses as errors and traces each error to its stage. Pooled Dice ranged from 0.184 (microaneurysms) to 0.579 (exudates); vessel Dice was 0.731. On 58,689 held-out images from six datasets, end-to-end quadratic weighted kappa was 0.804, with referral sensitivity 0.832 at specificity 0.947, and the screening gate caused 66% of errors. In ablations, the grade ignored the masks, even with the cross-attention gate started open. On all 4,105 official DDR test images, six-class accuracy was 85.6%, above the best published six-class result we found (83.8%). Staged screening systems should be evaluated end-to-end, with stage attribution and mask ablation, before clinical deployment.

Comment
8 pages, 8 figures, 8 tables. Submitted to the IEEE Journal of Biomedical and Health Informatics. Code, trained weights and per-image predictions: https://github.com/asifuddin01/HierarchiRetina

Closest papers

Nearest neighbours by meaning across the whole index.

Lesion-Aware Explainable AI for Diabetic Retinopathy Grading from Fundus Images

cs.CV cs.AI ·2026-11-14 ·Truong Thinh Nguyen, Hai Phong Nguyen, Truong Thanh Hung Nguyen, Giang Son Tran, Hung Cao
similarity 0.70
Abstract · 12 pages, 6 figures, 9 tables. Truong Thinh Nguyen and Hai Phong Nguyen contributed equally. Corresponding author: Truong Thinh Nguyen

Post-hoc explanations of deep-learning models for diabetic retinopathy (DR) grading are difficult to trust because different attribution methods highlight different retinal regions for the same image, and a visually plausible heatmap does not show that the highlighted pixels drive the prediction. We propose the Consensus-Calibrated Explanation Map (CCEM), which fuses Grad-CAM++, Ada-SISE, and SmoothGrad Integrated Gradients (SG-IG) using image-specific weights derived from annotation-free reliability cues: deletion sensitivity, inter-method agreement, compactness, retinal containment, and peak structure. CCEM explains a frozen ordinal grader, an EfficientNet-B7 with CBAM and a scalar regression head, pre-trained on EyePACS 2015 in Stage 1 and fine-tuned on APTOS 2019 in Stage 2 with quadratic weighted kappa (QWK)-optimized thresholds; it reaches a QWK of 0.920 on the hidden Kaggle test set and 0.559 on the external MAPLES-DR cohort. Explanations are evaluated on MAPLES-DR, 198 MESSIDOR images with expert pixel-level lesion annotations that are never used for training, threshold fitting, or fusion. On the 193 images with annotated lesions, CCEM obtains the highest Soft Pointing Game score (69.61%; 95% CI 63.7-75.3), defined as the ratio of the strongest lesion-supported saliency to the global map maximum rather than a lesion detection rate, together with the lowest deletion AUC (0.570) and the best deletion-insertion balance (0.115); each gain is significant against the strongest single explainer on paired tests. Annotation-free, per-image reliability weighting therefore turns three disagreeing explainers into one map whose peak evidence is more lesion-supported and more faithful to the model than that of any single explainer.

0.13

Explainable Diabetic Retinopathy Classification Using Vision Foundation Models

cs.CV cs.LG ·2026-08-28 ·Abhishek Verma, Anila Krishna, Abhishek Gajanan Bankar, Juan Miguel Lopez Alcaraz
code/data similarity 0.68
Abstract · 17 pages, 4 figures, source code under https://github.com/UOLMDA26/retinopathy_vision_foundational

Diabetic retinopathy (DR) is a leading cause of preventable blindness, and automated screening must be both accurate and trustworthy. We study an explainable DR classification framework built on vision foundation models and three transfer learning strategies. Three backbones, DINOv2, CLIP, and Vision Transformer (ViT), were adapted by full fine-tuning, linear probing, and Low-Rank Adaptation (LoRA). Models were trained and internally evaluated on the ODIR dataset and externally evaluated on APTOS to assess generalization. DINOv2-LoRA achieved the highest internal AUROC (0.758), whereas DINOv2 and ViT full fine-tuning achieved the highest external AUROC (0.920). Probability calibration was assessed with reliability analysis after isotonic regression. For explainability, Grad-CAM and HiResCAM maps were compared with expert-annotated lesion masks from the IDRiD dataset using Dice, Intersection over Union (IoU), and Pointing Game metrics. The results show that foundation models, particularly DINOv2, provide strong predictive performance, and that LoRA is a parameter-efficient alternative to full fine-tuning. Spatial overlap between explanation maps and annotated lesions was limited (mean Dice of about 0.13 for the combined lesion mask), which highlights the value of quantitatively testing whether model attention corresponds to clinically relevant retinal lesions.

0.23

Evidence-Guided Selection of Retinal Vessel Segmentation Pipelines: A Cross-Dataset Benchmark of Performance, Structure, Failure Modes, and Reproducibility

cs.CV ·2026-10-22 ·Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo +2 more
benchmark similarity 0.66
Abstract

Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structural fidelity, cross-dataset robustness, and application-specific error costs. We evaluated five executable binary vessel-segmentation pipelines (FSG-Net, SA-UNetv2, DCP-1024, GAVE, and FR-UNet) on 244 images from six public datasets using pixel-level agreement, cross-dataset stability, thin-vessel retention, structural metrics, error composition, and available computational evidence. Results were aggregated with equal weighting across datasets. No pipeline was optimal in every setting. FSG-Net achieved the highest equal-dataset mean Macro-F1 (0.77), IoU (0.63), clDice (0.83), and Skeleton F1 (0.78), whereas SA-UNetv2 achieved the highest mean sensitivity (0.85) and Thin-Vessel Sensitivity (0.63). Differences across datasets were often larger than those among the leading pipelines, and errors shared by all five methods were concentrated near annotated vessel boundaries and faint peripheral vessels. In an ancillary analysis on 45 HRF images, segmentation masks were converted into 11 ring-wise vascular features for leave-one-out classification. Controlled perturbations showed that local mask errors can be amplified in downstream features, while targeted stabilization reduced sensitivity for five features. The results support task-conditioned, benchmark-relative pipeline selection rather than a single universal ranking and highlight the need to validate the selected pipeline on the intended target domain.

0.09

Automated 2D and 3D Segmentation of AMD and DME Lesions in OCT

cs.CV ·2026-08-27 ·Lucia Sundberg, Zhihao Zhao, M. Ali Nasseri
similarity 0.65
Abstract

Age-related macular degeneration (AMD) and diabetic macular edema (DME) are leading causes of vision loss, and optical coherence tomography (OCT) is the standard modality for detecting and monitoring the subtle lesions that drive treatment decisions. Most deep-learning segmentation work for OCT is validated only in-domain, leaving generalization to clinical data collected under different acquisition protocols largely untested. This work develops and systematically ablates four lesion-segmentation pipelines -- 2D and 3D variants for AMD and DME -- reaching Dice scores of 0.76 to 0.82 with strong volumetric and surface calibration (r vol, r surf greater than or equal to 0.97 across all four pipelines) on an in-domain validation set. The ablation process establishes a full-volume, calibration-aware adoption standard that catches mechanisms an ordinary slice-level evaluation would keep, and identifies ensemble composition as the most consistent driver of improvement. To test generalization, the models are evaluated on OLIVES, an external clinical cohort with no lesion-level ground truth, using a proxy-metric framework built around biomarker AUROC, central subfield thickness (CST) correlation, and longitudinal concordance. Predictions track clinical biomarkers outside the training distribution, though less strongly than in-domain -- evidence for, not validation of, automated lesion-burden tracking as a clinical tool.

0.25

DR-LiteNet: A Lightweight Explainable Hybrid CNN Framework for Imbalanced Diabetic Retinopathy Grading via Adaptive SMOTE Fusion

cs.CV ·2026-11-03 ·Nishi Kanta Paul, Md Shihabul Islam Shovo, Audrija Chowdhury, Israt Jahan Esha
publishedcode/data similarity 0.64
Abstract · 6 pages, 3 figures, 2 tables. Accepted at the 1st International Conference on Next-Generation Electrical & Electronics, Computer Systems, an…

Automated diabetic retinopathy (DR) grading from colour fundus photographs is held back by two compounding challenges: severe class imbalance across five severity grades and the heavy computational cost of large scale architectures in resource constrained clinical settings. We introduce DR-LiteNet, a dual branch hybrid convolutional neural network that tackles both problems at once. The CNN branch extracts 1,280 dimensional deep features through EfficientNetB0, while the handcrafted (HC) branch produces a compact 51 dimensional lesion descriptor capturing vessel density, exudate intensity, texture entropy, and HSV colour histograms. Concatenating both branches yields a 1,331-d hybrid embedding, on which Adaptive SMOTE (ADASYN) is applied during training to synthesise minority class feature vectors, correcting distributional skew without touching the image space. A two phase training protocol first warms up the classification head on balanced features, then fine tunes the full network end to end. Grad CAM saliency maps deliver post-hoc clinical explainability. Tested on APTOS 2019 under five fold stratified cross validation, DR-LiteNet reaches 88.77% +/- 0.61 accuracy, a quadratic weighted kappa (QWK) of 0.884 +/- 0.010, and a macro F1 of 0.792 +/- 0.008 with only 4.69 M parameters beating ResNet50 (23.5 M) by DeltaQWK = 0.022 while staying practical on a single Google Colab T4 GPU. The source code of this project is available at: https://github.com/Nishi-Kanta-Paul/DR-LiteNet.

0.40

A Stage-Wise Explainable Pipeline for Arteriolar-to-Venular Ratio Estimation and Retinopathy Screening

cs.CV cs.AI ·2026-11-10 ·Sharan Sharmeela Karuppannan, Yoga Sri Varshan, Subin Sahayam, Umarani Jayaraman
published similarity 0.64
Abstract · Accepted for presentation at the 23rd IEEE India Council International Conference (INDICON 2026)

The arteriolar-to-venular diameter ratio (AVR) is a clinically motivated marker of retinal vascular health. We present a five-stage pipeline for AVR estimation and exploratory retinopathy screening from fundus images, with inspectable intermediate outputs at each stage. The pipeline combines vessel and artery-vein masks, optic-disc localization, vessel-calibre estimation using a minimal-chord boundary walk, and AVR computation from dominant arterial and venular branches. An explicit threshold-based rule produces the screening decision, enabling errors to be traced to individual processing stages. On an exploratory cohort of 30 HRF images, we report 96.7% accuracy, an F1-score of 0.968 and ROC-AUC of 0.978. Ablation studies and an exploratory comparison with VascX examine the effects of vessel pairing, calibre measurement and aggregation. Interpretation is limited by the small cohort, proxy disease labels and absence of independent reference calibre measurements. The pipeline provides a transparent framework for investigating retinal vascular biomarkers, with further validation needed on larger, clinically graded cohorts.

0.32

CalibCause: A Quality-Gated, Interpretable and Calibrated Deep Learning Framework for Diabetic Retinopathy Grading

eess.IV cs.LG ·2026-10-28 ·Sohaib Sulman, Muhammad Atif Saeed, Akhtar Jamil, Alaa Ali Hameed, Roland Aydin
similarity 0.63
Abstract · 15 pages, 8 figures, 6 tables

Most deep learning systems for diabetic retinopathy (DR) grading are evaluated on a single data source, with limited evidence of cross-site generalisation, uncertainty calibration, and interpretability. We propose CalibCause, a quality-gated mixture-of-experts framework that combines per-expert visual explanations, label-free image-quality conditioning, knowledge distillation, and calibrated confidence with deferral. We evaluated the framework using 51,310 fundus images from EyePACS, DDR, and APTOS 2019, with IDRiD and DeepDRiD for external testing. Evaluation included pooled testing, leave-one-environment-out experiments, paired bootstrap confidence intervals, and local grade-threshold adaptation. On the pooled test split, the label-free distilled student achieved quadratic weighted kappa (QWK) of 0.863 and accuracy of 0.865 with 27.8 million parameters, 52% fewer than its teacher. Across held-out environments, the label-free model achieved mean QWK of 0.741 compared with 0.743 for a plain ConvNeXt-Tiny baseline, while adversarial invariance did not improve cross-site grading accuracy. Refitting grade thresholds using 200 labelled images increased held-out EyePACS QWK from 0.533 to 0.621 for the label-free model. After vector scaling, expected calibration error ranged from 0.025 to 0.036 across CalibCause variants, and deferring the least confident 20% of images increased student accuracy from 0.865 to 0.923 on the remaining images. These findings demonstrate that quality-aware grading, interpretable expert routing, model compression, and calibrated deferral can be integrated without sacrificing cross-site performance relative to a plain baseline, although reliable deployment still requires local validation and adaptation.

0.22

RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM

cs.CV cs.LG ·2026-11-09 ·Jaafar M. Al-Ghabban, Mohammad Reza Mohammadi
similarity 0.63
Abstract

Retinal disease monitoring with optical coherence tomography angiography (OCTA) relies on segmentation of vessels and the foveal avascular zone (FAZ). Promptable models such as SEEM (Segment Everything Everywhere All at Once) allow click-based refinement, but without adaptation SEEM segments thin vessels poorly and needs many clicks. Fully fine-tuning its 342 million parameters on a few hundred images is costly and risks overfitting, and parameter-efficient methods such as low-rank adaptation (LoRA) usually adapt only the encoder. Yet SEEM reads every candidate mask from one feature map at quarter resolution, too coarse for vessels one to three pixels wide. This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution. Each candidate accesses them through its own vector and a zero-initialised projection, so the model starts exactly as SEEM. The encoder branch, a standard rank-1 LoRA, supplies the information needed to tell arteries from veins. RBA adds 0.47 million trainable parameters. Under simulated error-driven clicks, with the ground truth used only to place them, RBA outperforms LoRA, Conv-LoRA andAdaptFormer on OCTA-500 3mmlarge vessels. Averaged over three seeds, it reaches an intersection over union (IoU) of 85.16% and a Dice score of 91.93%, 2.90 and 1.72 percentage points above Conv-LoRA. On the 6 mm subset, one run gives margins of 4.35 and 2.76 points. The gain extends to arteries, veins and ROSE-O but not to the FAZ. In SEEM, adaptation capacity pays more at the mask read-out than in the encoder.

0.25